CS Paper Radar

Daily listing

2026-11-23 · stat.ME

11 papers first submitted this day (UTC) in stat.ME — stat.ME. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 2

LUCID: Statistically Grounded Self-Correction for LLM Reasoning Evaluation

cs.CL cs.LGstat.ME ·2026-11-23 ·Satiyabooshan Murugaboopathy, Adel Daoud, Connor T. Jerzak
published
Abstract · Findings of EACL 2027

Cheap language-model raters grade chain-of-thought reasoning at scale, yet systematic step-rating errors can skew reasoning audits and solution rankings. We introduce LUCID (Loop for Unbiased Calibration via Inference-time Diagnosis), which pairs prompt self-correction with Design-based Supervised Learning (DSL). Without retraining or weight access, LUCID calibrates binary step ratings by aligning predicted and expert soundness rates. From a small expert-labeled set, LUCID summarizes rater bias in plain text and prompts the rater to re-grade unseen steps. For example, on PRM800K, GPT-5-mini grades too strictly, under-rating computation, verification, and late-trace steps most acutely. In one pass, LUCID shrinks GPT-5-mini's calibration gap from 7.8 to 0.9 percentage points in absolute predicted-expert rate difference. LUCID also halves false alarms (sound steps rated unsound) and lifts error-detection F1 on unsound steps by 32%. LUCID retains these gains with 1,000 diagnostic steps or overall-gap feedback alone. The loop also transfers across models and domains: it applies GPT-5-mini's bias profile to lift GLM-5.2's PRM800K accuracy, and it narrows calibration gaps for overly strict but capable raters across math, science, web, and logic benchmarks. Because prompt feedback shifts thresholds without improving class-balanced sound/unsound discrimination, LUCID filters re-grading with pre-/post-checks that skip already calibrated raters and roll back ineffective passes. Finally, we reuse that expert set with raw corpus ratings in DSL for calibration and regression debiasing, and apply DSL to pair-labeled steps for sound-step transitions. DSL's out-of-fold soundness probabilities lift best-of-K selection to match expert labels, while its doubly-robust estimators beat expert-only regression fits at small budgets and cut sound-step transition error by nearly two-thirds.

0.38

Model-Assisted Probability of Detection Studies for Image-Based Human Inspection

eess.IV stat.APstat.ME ·2026-11-23 ·Qizheng Xia, William Q. Meeker, Joseph N. Gray, Qing Li
unusual
Abstract · 31 pages, 15 figures, 2 tables

Establishing a probability of detection (POD) curve is important for assessing the reliability of components in aging systems. Traditional POD studies rely on physical specimens containing representative flaws and human inspectors who record detection results, making such studies costly. This paper demonstrates how appropriately validated physics-based simulation can substantially reduce, and in suitable applications potentially replace, physical POD experiments. We use XRSIM, an X-ray radiographic simulator, to generate weld images containing cracks of varying size, morphology, and location. Flaw characteristics, locations, and the number of flaws per image were randomized, with images containing zero to three flaws. Each simulated flaw is treated as an observational unit contributing flaw-level hit-miss responses. To capture human inspection variability, the images were presented in random order to five inspectors, each of whom inspected the images twice. The resulting data were analyzed using a repeated-measures binary-regression model accounting for flaw-to-flaw, inspector-to-inspector, flaw/inspector-combination, and inspection-to-inspection variability. Bayesian inference was used to estimate the population-mean POD curve, inspector-specific POD curves, and associated statistical uncertainty. Results show that flaw-to-flaw variability dominates, with appreciable differences among inspectors. The study provides a framework for combining physics-based image simulation with controlled human inspection to estimate POD while reducing the experimental burden of physical specimen fabrication.

0.28