CS Paper Radar

Daily listing

2026-09-08 · cs.HC

28 papers first submitted this day (UTC) in cs.HC — Human-Computer Interaction. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Robotics, Control & Signals 2

Understanding emotional and behavioural responses through physiological signal analysis recorded during theatrical performance

eess.SP cs.HC ·2026-09-08 ·Aditi Site, Annariina Lohiranta, Tarmo Lipping
Abstract

Among various cultural interventions, theatre offers a powerful medium for emotional expression, reflection, and social connection. Live performances can positively influence mental well-being. Therefore, studying audience responses during theatrical performances can provide valuable insights into the relationship between theatre, emotional experiences, and well-being. Physiological responses have emerged as an important modality for identifying patterns associated with different emotional states. However, in naturalistic environments such as live performances, analysing these signals is challenging due to the absence of explicit labels. In this study, we focus on understanding emotional and behavioural responses using physiological data collected during a live theatrical performance. Data were recorded from participants using multiple sensing modalities. In addition, a comprehensive analytical framework was employed, which included demographic analysis, visual exploration of physiological signals, participant-level observations, scene-wise physiological analysis, and intensity-based analysis using z-score normalization to summarize the findings. The findings revealed that dramatic, surprising, and intense scenes produced the strongest activation, often with concurrent increases in HR and SCL, whereas empathy-driven scenes showed lower and more stable responses. Humorous scenes elicited moderate-to-high activation, particularly in the presence of sudden reactions or loud sounds. Analyses also identified shared physiological response patterns across participants, with activation concentrated around key emotional events. These results indicate that combined HR and SCL measures can effectively capture variations in audience engagement during live theatrical performances.

0.32

A Controlled Comparison of Manual and Teleoperated Intraocular Instrument Motion for an Input Device

cs.RO cs.HC ·2026-09-08 ·Korab Hoxha, Mirza Imamovic, Angelo Henriques, M. Ali Nasseri
Abstract · This work has been submitted to IEEE Access for possible publication

Input devices for robotic microsurgery are frequently described as preserving the surgeon's trained technique, but the claim is rarely measured. We compared manual and teleoperated intraocular instrument motion with the trocar constraint, the instrument, the eye model and the tracking source common to both conditions, so that the control interface was the only factor varied. Prior comparisons cannot hold the instrument fixed, because a robotic instrument is not the tool used manually. Sixteen participants performed a navigation task on a commercial ophthalmic simulator by hand and through a three-degree-of-freedom input device commanding a five-joint robot. Task outcome was equal but at ceiling: every participant acquired all five targets under both interfaces with no retinal or lens injury. Execution differed on every measure. Teleoperated trials took three times as long at a quarter of the median speed, covered less than half the angular working range, and were broken into 3.5 times as many separate movements. Completion time and movement fragmentation improved substantially across four trials of practice and had not plateaued; the measures set by the configured rate ceiling and joint limit changed the least. Finger activity doubled and pinch variability tripled, so reducing instrument degrees of freedom redistributed manual effort rather than reducing it. The interface preserves the outcome and reshapes the execution.

0.30