CS Paper Radar

Daily listing

2026-11-16 · cs.DC

12 papers first submitted this day (UTC) in cs.DC — Distributed, Parallel, and Cluster Computing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Systems & Networking 6

Top-Level Operational Equilibrium: When is the response of a distributed system predictable from its own telemetry?

cs.DC cs.PF ·2026-11-16 ·Víctor Casamayor Pujol, Nefeli-Marina Rouska, Boris Sedlak
theorycode/data
Abstract · 38 pages, 1 figure, 14 tables. Code and data: https://github.com/vikcas/TLOE-theoretical_analysis (doi:10.5281/zenodo.24200155)

Distributed systems deployed across the edge-cloud continuum are adapted continuously: scaled, re-routed, given more or less capacity. Each adaptation rests on an expectation of how the system will respond, yet operators cannot tell from the telemetry they already collect whether that response is predictable. We define top-level operational equilibrium (TLOE), a notion of equilibrium for a running system, stated relative to the controls its operator declares. TLOE has three conditions: stationarity with time-scale separation, sufficiency of a top-level aggregate for the controls, and time-reversibility of that aggregate. We prove that an aggregate satisfying the last two exists if and only if the minimal sufficient statistic of the controls is time-reversible, so the coarsest admissible aggregate is derived rather than chosen. Under the first two conditions, the response to a small control change follows from passive telemetry through the steady-state fluctuation-response identity, with a conjugate observable fixed by the type of control: the total work in progress for a change of load, the occupancy of a stage for a change of its capacity. For chains of exponential single-server stages with Poisson input, TLOE holds exactly for load control at every stable throughput, but never for a control on the capacity of the first or last stage. On reference models, a per-stage conjugate overestimates the early response about threefold, blocking between stages breaks both conditions weakly, and a hysteretic autoscaler leaves no admissible aggregate at any reaction time computed. We specify a test for each condition, show that a static sufficiency test with an estimated top-level conjugate has no power, and quantify on simulated telemetry the window lengths the prediction and the reversibility test need. The evidence is on reference models; real telemetry is left to future work.

0.43

The Bipartible Architecture Pattern: Transparently Directing HTTP Requests over InfiniBand

cs.DC ·2026-11-16 ·Richard Henwood, John Lockman, Luke Wilson
Abstract · Presented at 8th International Workshop on Containers and New Orchestration Paradigms for Isolated Environments in HPC

Large-scale compute (HPC) systems with coherent-memory workloads often deploy InfiniBand (IB) networks for high-bandwidth and low-latency inter-node and storage communication. A separate TCP network is typically used for control-plane and general-purpose communication. The last decade has seen the rise of cloud-native software patterns. These patterns are characterized by container-based software distribution and inter-node and storage communication over TCP/IP. In an unoptimized HPC environment, a cloud-native workload will typically use HTTP for some or all communication. This paper introduces the Bipartible architecture pattern to optimize cloud-native workload traffic in HPC environments. This paper focuses on optimizing HTTP storage service requests. These requests are transparently transformed onto IB traffic without modifying workload implementation or network configuration. This is achieved by 'cloning' a global HTTP service (BPService) onto the HPC cluster compute host(s) where the workload executes at scale. Provided the global persistent storage is on the IB network the HTTP service requests are returned to the workload via IB and not TCP/IP. The feasibility of this pattern is demonstrated by implementing a prototype BPService for S3 and a Hybrid-BPService (service metadata is accessed over TCP, bulk data over IB) for a software repository service. We offer this pattern in addition to many alternative approaches to address the performance challenges of executing workloads written to cloud-native design patterns in HPC environments. Finally, while the initial results are encuraging signficant validation of any service must be performed under both read and write scenarios before deployment into production is planned.

0.29

A Matter of Stages: Energy-Latency Trade-offs in Multimodal LLM Serving

cs.DC ·2026-11-16 ·Yifan Sun, Jiantong Jiang, Zhexiang Zhang, Xu Bai, Feng Liu +2 more
Abstract

Online serving of multimodal large language models requires deciding whether to separate visual encoding (E), prefill (P), and decode (D) across GPUs and how to configure their frequencies. EPD disaggregation enables independent stage control, but it also changes communication and queueing behavior. Lowering one stage's frequency can increase queueing and prolong execution across the EPD pipeline. Consequently, reducing power at one stage does not necessarily reduce total GPU energy per request. In this paper, we systematically characterize fused and EPD-disaggregated serving across four multimodal models under a fixed three-GPU budget, followed by single-stage and uniform downclocking experiments across 18 workload combinations. We find that disaggregation reduces GPU energy per successful request by 13.3-37.0% at nearly identical output-token throughput, but increases mean TTFT. Downclocking exhibits distinct stage sensitivities, and aggressive frequency reductions can offset power savings through queueing and longer execution. Across the evaluated workloads, uniform downclocking to 80% reduces GPU energy by 11.7-18.6% with modest mean-latency changes. Guided by these findings, we develop a budgeted frequency exploration strategy to select energy-efficient configurations under latency constraints. Evaluation shows that four probes can identify the lowest-energy feasible configuration among 25 measured candidates across all 288 evaluated positive-margin SLO scenarios. These results provide practical guidance for energy-efficient multimodal serving.

0.23

GNoF: A Low-SM-Overhead GPU-Native NVMe-over-Fabrics Completion Path for Data-Intensive GPU Workloads

cs.DC cs.AR ·2026-11-16 ·Lei Tian, Wenhao Gu
Abstract · 9 pages, 5 figures, 4 tables

GPUs are the main compute engine for data-intensive workloads whose datasets exceed device memory and reside on remote flash. The conventional host CPU orchestrates every NVMe-over-Fabrics (NVMe-oF) transaction and stages data through host memory, costing high CPU usage, repeated CPU-GPU synchronization, and redundant data movement. GPU-initiated storage removes the CPU from the I/O path, but existing designs leave two problems: synchronous lock-step completion pins streaming multiprocessors (SMs) in spin-polling, wasteful over a 10-100 microsecond RDMA round trip, and current GPU-native remote systems focus on target-side firmware while using per-command doorbells and periodic CQ polling. We present GNoF, a GPU-native NVMe-oF/RDMA data path where GPU threads build command capsules, post send work-queue elements, ring doorbells, and reap completions entirely on the device; the CPU only handles one-time connection setup, the admin queue, and a keep-alive thread. Three mechanisms target long fabric round trips: a doorbell mover that coalesces a burst's doorbells into one MMIO ring; a batched CQ poller with a lock-free fast peek and monotonic completion counters that cannot lose a wakeup; and a set-associative, reference-pinned GPU page cache with split fetch/wait pipelining and orphan-fill takeover. GNoF needs no target or firmware change and runs against an unmodified SPDK target. On a 200 Gb/s InfiniBand fabric, GNoF reaches 1.77 million 4 KB IOPS per client at 0.37% host CPU and about 1% SM occupancy, versus 40% CPU for kernel nvme-rdma and about 100% SM occupancy for lock-step polling. Against three existing baselines (kernel nvme-rdma, BaM over a BlueField-3 DPU, and BaM on a local SSD) under identical workloads, we show 10-22x gains on selective column I/O, CPU-burn immunity, and the regime where bulk staging is faster.

0.20

Investigating the Impact of CI-Source Sensitivity in Carbon-Aware Resource Management Systems

cs.DC ·2026-11-16 ·Gonçalo Ferreira, Jaime Iglesias Blanco, María Castrillo, Álvaro López García, Li Wu +1 more
Abstract · 9 pages, 6 figures, 6 tables

The sustainable growth of data centres increasingly depends on Resource-Management Systems (RMSs) that aim to reduce carbon emissions of computing workloads without degrading performance. This need is intensified by the rise of Artificial Intelligence (AI) workloads, which demand exponentially growing amounts of compute and energy across geographically distributed infrastructure. Recent carbon-aware RMSs exploit temporal and spatial variation in grid Carbon Intensity (CI) to shift workloads towards lower-carbon periods or locations. In practice, CI estimates and forecasts can be inaccurate and uncertain, and CI providers' methods differ substantially. Such discrepancies may have a significant impact on RMS placement decision-making, raising concerns about the fragility of existing solutions. Thus, in this work, we ask how discrepancies between plausible CI estimates propagate into resource-management decisions and operational outcomes. To answer this question, we harmonise and characterise CI traces from Wattnet and ElectricityMaps across five Central European zones. We then propose our evaluation framework: External CI Signal Characterisation And Perturbation Evaluation (ESCAPE), which assesses provider switching and controlled CI perturbations in a reproduced placement setting. We implement our framework using CarbonEdge as a use case, and measure changes in placement decisions and operational outcomes, such as carbon proxy, energy use, and latency. Our results show that switching CI-source changes the dominant placement site in 43.50% cases, and alters reported operational outcomes. These changes occur despite high rank correlation and structured disagreement between CI-sources. This observed sensitivity to CI-source choice motivates robustness-aware carbon-aware placement, in which CI uncertainty should be explicitly accounted for in resource-allocation decisions.

0.14

Lower Bounds for the Distributed Computation of Degeneracy and k-Core

cs.DC ·2026-11-16 ·Lélia Blin, Yan S. Couto, Cristina G. Fernandes, Pierre Fraigniaud, Marcos Kiwi +2 more
theory
Abstract

The degeneracy of a graph $G$ is the maximum integer $k$ such that $G$ has a non-empty $k$-core, where the $k$-core is the largest induced subgraph with minimum degree $k$. Computing the $k$-core of a graph $G$ is P-complete. In the decentralized setting, the sequential peeling algorithm can be distributed so that the core value of every node, i.e., the largest integer $k$ for which the node belongs to the $k$-core, is computed in $O(n)$ rounds in $n$-node networks, where adjacent nodes exchange only $O(\log n)$ bits at each round, i.e., in the standard CONGEST model. However, while $Ω(D)$ rounds is a trivial lower bound for these problems in networks of diameter $D$, this does not rule out the existence of an algorithm running in $O(D)+o(n)$ rounds in CONGEST, as it is the case for many very important graph problems, including MST. We show that it is unlikely that such an algorithm exists, or, if it does exist, then it requires $\tildeΩ(\sqrt{n})$ rounds. Specifically, our first main result states that, for any $ε>0$, approximating the degeneracy up to a multiplicative factor $2-ε$ requires $\tildeΩ(\sqrt{n})$ rounds in CONGEST even in networks of diameter $O(\log n)$, and still $\tildeΩ(n^{1/3})$ rounds in networks of constant diameter. We also show that improving this lower bound seems challenging, as we demonstrate that the newer frameworks cannot be used as black boxes to obtain a better lower bound for degeneracy. Our second main result provides a better bound, albeit conditional. It states that, unless the well-known circuit value problem (CVP) admits a parallel polynomial speedup -- an outcome considered unlikely -- it holds that, for every $ε>δ>0$, deciding whether a graph is 2-degenerate cannot be solved in $O(D+ n^{1-ε})$ rounds with $O(n^δ)$-time parallel local computation per round at each node.

0.12