CS Paper Radar

Daily listing

2026-10-27 · cs.ET

3 papers first submitted this day (UTC) in cs.ET — Emerging Technologies. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Systems & Networking 2

Self-Referenced Diagnosis of SPAD Dark-Count-Rate Switching for Quantum Communication Receivers

cs.ET ·2026-10-27 ·Yu Luo, Lina Pu, Yaroslav Koshka, Chun-Hung Liu, Junming Diao
unusual
Abstract · 13 pages, 12 figures

Single-photon avalanche diodes (SPADs) are essential components of quantum communication receivers. In practical systems, some SPADs exhibit intrinsic step-like changes in dark-count rate (DCR), commonly referred to as random telegraph signal (RTS) noise. Similar RTS-like variations, however, can also arise from stray light, temperature-dependent threshold crossings, cable disturbances, electrical interference, and other readout artifacts. Distinguishing intrinsic RTS from these artifacts is important because they originate from different mechanisms and require different corrective actions. We present a self-referenced diagnostic that primarily uses the low-to-high afterpulse-yield ratio R, together with complementary checks based on DCR-state reproducibility, cross-channel behavior, and event timing. Four commercial SPAD modules were monitored in darkness for more than 920 h. Three exhibited intrinsic DCR switching of 44.59%, 19.33%, and 2.77%, with corresponding R values of $0.9996\pm0.0027$, $1.0050\pm0.0023$, and $1.0027\pm0.0043$, all consistent with unity. Controlled experiments reproduced temperature-related threshold crossings, light leakage, cable-contact artifacts, and artificial electrical injection. These artifacts produced distinct correlation and timing signatures: temperature-related threshold crossings gave intermediate pair-survival responses, cable disturbances and electrical injection generated sub-dead-time events, while light leakage produced simultaneous cross-channel switching and nonreproducible DCR levels. Combining R with orthogonal timing and DCR-based checks provides a practical self-referenced diagnostic framework for distinguishing intrinsic RTS from non-intrinsic artifacts using primarily time-tagged dark-count data.

0.30

Online gas classification at the edge

cs.ET cs.LGstat.ML ·2026-10-27 ·Ton Juny Pina, Hugh Greatorex, Elisabetta Chicca
Abstract

Field applications in chemical sensing, from portable safety monitors to mobile robots, require models that are lightweight, fast to respond, and can be recalibrated from limited labelled data. Current gas classification pipelines assume controlled sampling cycles and offline feature extraction, and rely on computationally expensive models. With a few thousand neurons and sub-milliwatt power consumption, insects reliably classify odours in open environments. Inspired by the insect olfactory system, we present a neural network architecture that classifies raw sensor array readings using a sparse, high-dimensional binary representation. We evaluate it on random sequences of single gases and binary mixtures, introducing new samples dynamically and classifying gas identity from the transient sensor response. In this setting, the architecture out-performs a linear \gls{svm} on gas mixtures and matches an optimised non-linear \gls{svm}, while maintaining online class-level frequency estimates that distinguish familiar from novel stimuli. It relies exclusively on binary weights and Hebbian-based local learning, remaining computationally lightweight and well suited to ultra-low-power neuromorphic processors. We demonstrated the network on-chip with a hazardous gas detection experiment running on the mixed-signal neuromorphic chip TEXEL. The on-chip classifier yielded an accuracy of 74.6\% while running at 482 $\unit{\nano\joule}$ per inference and 27 \unit{\micro\watt} of static-power.

0.25