CS Paper Radar

Daily listing

2026-11-18 · cond-mat.mtrl-sci

2 papers first submitted this day (UTC) in cond-mat.mtrl-sci — cond-mat.mtrl-sci. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 2

Structured Extraction of Diffraction Data from Covalent Organic Frameworks

cs.CV cond-mat.mtrl-scics.AI ·2026-11-18 ·Shenghan Gao, Zhiling Zheng
code/data
Abstract · 66 pages: main text (19 pages, 7 figures, 3 tables) and Supporting Information (47 pages) in one file. Data and code: https://github.com/Aar…

Powder X-ray diffraction (PXRD) is the primary structural evidence for covalent organic frameworks (COFs) and many other materials. Yet decades of measured patterns exist only as images in published figures. Automatic recovery is difficult, because PXRD figures vary widely in format, from a single curve to crowded stacks with labels, insets, and neighboring plots that challenge traditional computer vision. This work presents a pipeline in which a vision large language model (LLM) interprets the layout of each figure, locating the diffraction plot and its curves and sketching a coarse trace of each, while classical computer vision (CV) refines every trace to pixel-level accuracy. Applied to 3,954 COF articles, the pipeline produces 11,445 calibrated diffraction curves, released in the open database COF-PEAK. Compared with a hand digitization of 60 panels, extracted peak positions differ by a median of only 0.07 degrees. Whereas papers usually report only a few peak angles, which limits further analysis, the digitized curves enable tracking how peak prominence, a possible marker of crystallinity, changes with synthesis conditions. Vision LLMs and classical CV can thus turn such figures into reusable experimental data.

0.42

4D-TEMPO: Differentiable 4D-STEM ptychography via fast Physics Optimizers

cs.CV physics.ins-detcond-mat.mtrl-scimath-ph+1 ·2026-11-18 ·Ramani Duraiswami, Yichao Zhang
Abstract · 34 pages: 8-page paper, references, and 23-page supplementary material; 10 figures, 10 tables

Electron ptychography recovers atomic structure from 4D-STEM data: diffraction patterns at multiple positions of a scanned probe. Current codes reconstruct an image and read atoms off it, or fit atoms under an $L_1$ loss; neither gives per-atom uncertainty. We propose 4D-TEMPO, a differentiable physical renderer that fits the atoms, the microscope, and the detector directly to the recorded electron counts under a Poisson likelihood. The output is a list of atoms, each a Gaussian primitive with a 3D position, a thermal width, and a model-conditional error bar from the Fisher information. The Fisher information also conditions the solver, gives the dose (electrons per Å$^2$) each parameter needs, and separates calibration from imaging. On a simulated WSe$_2$ bilayer, starting from the published reconstruction, fitted atoms cut in-plane error by a third (3.2 vs. 4.8 pm) and depth error by 40-61% against its 3D peaks. Depth comes from multiple scattering into the dark field, the faint counts outside the direct beam. The two layers, $10\times$ closer than the depth of field, separate; per-atom depth then follows the layer geometry. When the model is well specified, the bars are calibrated (69% of position coordinates within $1σ$). On experimental WSe$_2$, fitted atoms predict held-out patterns better than the three published codes we test. With free probe modes where atoms are incomplete, the same likelihood predicts best on all three held-out benchmarks, matches every WSe$_2$ baseline in 5 min against up to 20.5 h, and passes torchslice at its released setting 180$\times$ sooner on PrScO$_3$. Per-atom error bars, planned doses, and fast reconstruction point to low-dose, real-time 3D imaging of beam-sensitive and dynamic materials.

0.22