CS Paper Radar

Daily listing

2026-08-16 · eess.IV

5 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 5

TractoGraphVLM: A Unified Vision-Language Framework for White Matter Tractography

eess.IV cs.CV ·2026-08-16 ·Gurucharan Marthi Krishna Kumar, Janine Dale Mendola, Amir Shmuel
publishedcode/data
Abstract · Accepted as a Spotlight at the ECCV 2026 Workshop on Artificial Intelligence for Medical 3D Vision (AI4M3D). Our codebase, including all tra…

Vision language models have transformed 2D medical imaging, yet extending them to 3D white matter tractography remains challenging due to the complex topology of fiber bundles. We introduce TractoGraphVLM, a unified framework for four tasks, bundle classification, text-to-tract retrieval, anatomical captioning, and visual question answering, built on a shared GPS architecture, training procedure, and read-out design. Fiber bundles are represented as streamline graphs whose nodes encode 3D position and tangent orientation. A General, Powerful, Scalable (GPS) graph transformer produces bundle embeddings aligned with a frozen BiomedBERT text encoder via contrastive learning, while a BioGPT decoder with visual prefix tokens generates captions and answers. A single shared encoder and decoder is trained jointly across all four tasks and evaluated from one checkpoint. Trained on HCP Young Adult subjects, TractoGraphVLM achieves 91.8% bundle classification accuracy, 84.7% retrieval R@1, BLEU-4=20.1, ROUGE-L=66.8, and 66.4% VQA accuracy on a held-out test set. The same checkpoints transfer zero-shot to HCP Aging subjects, with a modest drop on discriminative tasks and a larger drop on generative tasks, showing robustness to age and acquisition shift. Language supervision yields richer representations than label-only training, recovering structure like hemisphere and fiber family, carried by captions but never given as a label. Swapping only the visual encoder, graphs preserving fiber orientation outperform volumetric baselines, with GPS giving the best balance. Generative metrics measure consistency with a structured knowledge base rather than independent clinical text; even so, TractoGraphVLM shows that classifying, retrieving, describing, and answering questions about a white matter bundle can be served by one jointly trained model that learns transferable neuroanatomy from language alone.

0.40

MagViT: Interpretable Multi-Magnification Transformers with Patient-Level Model Selection for Breast Histopathology

eess.IV cs.CVcs.LG ·2026-08-16 ·Nabil Ashab, Soumit Kumar Kundu, Saif Mahmud Parvez, Shahadat Hossain Sohag, Bidhan Biswas +1 more
published
Abstract · 13 pages, 5 figures, Accepted for publication in the International Conference on Electrical, Computer and Communication Technologies (ECCT 2…

Breast cancer is one of the most common types of cancer among women around the world. Rapid detection and early treatment can hinder its progress to more complex stages and can impede its spread to other parts of the body. Histopathological image classification is the most common task in cancer detection due to its robustness in analyzing cellular data. Breast histopathology classification requires handling both multi-scale tissue morphology and clinically relevant generalization beyond the source domain. This paper presents MagViT, an interpretable multi-magnification transformer framework with scale-gated fusion and patient-level model selection. The model uses four BreakHis magnifications (40X, 100X, 200X, 400X) and extracts per-scale representations with a ViT backbone, and combines them via a learnable gate that masks missing scales. Patient-level five-fold cross-validation with a fixed seed has been run and compared with three architectural branches. The most accurate branch is then selected as the final model due to the strongest patient-level accuracy while retaining the simplest fusion pathway. On BreakHis, our architecture achieves a mean image accuracy of 0.9191, a mean patient accuracy of 0.9643, and a mean macro-F1 of 0.9042. External transfer experiments provide preliminary evidence of cross-dataset generalization under controlled adaptation settings on BUSI (image accuracy 0.8306, macro-F1 0.7480, patient accuracy 0.8291) and IDC (image accuracy 0.8577, macro-F1 0.8191, patient accuracy 0.8372). Grad-CAM visualization indicates that the model focuses on diagnostically significant and meaningful regions across magnifications. Relative to prior ViT-centered BreakHis work, this study emphasizes patient-level selection and cross-dataset robustness under a reproducible protocol.

0.25

ORViT-DR: Ordinally-Robust Hybrid ViT for Low-Resolution Diabetic Retinopathy Grading

eess.IV cs.CV ·2026-08-16 ·Soumit Kumar Kundu, Nabil Ashab, Bidhan Biswas, Shahadat Hossain Sohag, Saif Mahmud Parvez +2 more
published
Abstract · Accepted at ECCT 2026

Diabetic retinopathy (DR) is one of the main causes of impaired vision. A good and reliable automated grading system can make the screening process safer and more accurate. Because DR stages progress gradually, the task of grading disease severity naturally follows an ordinal structure in which neighboring classes share similar visual characteristics. In this study, ORViT-DR, a hybrid deep learning framework, is designed to improve DR grading from low-resolution retinal images. The proposed approach combines convolutional feature extraction with transformer-based global context modeling through a pre-trained ViT-Hybrid backbone, which integrates BiT-ResNetv2 with a Vision Transformer architecture. The approach is tested on the RetinaMNIST subset of the MedMNISTv2 dataset, which contains 28x28 retinal fundus images annotated with five levels of disease severity. To promote stable training and better feature learning, the training strategy applies progressive layer unfreezing, layer-wise learning rate decay, exponential moving average (EMA) parameter updates, and ensemble-based prediction during inference. Experimental results on the official RetinaMNIST test set show that the proposed method achieves 57.00% classification accuracy, along with a quadratic weighted kappa score of 0.5963 and a macro-F1 score of 0.4293. These results suggest that hybrid CNN-Transformer architectures can provide effective representations for ordinal retinal image analysis.

0.19

Deep learning-based computed tomography (CT) derived body composition classifier for colorectal cancer patients

eess.IV cs.LG ·2026-08-16 ·Eve Harling, Chattarin Pumtako, Bernd Porr, Donald C McMillan, Ross D Dolan
Abstract · 27 pages, 4 figures

Background: Accurate body composition analysis using Computed Tomography (CT) scans is essential for assessing skeletal muscle area (SMA) and skeletal muscle density (SMD), key markers of nutritional status in cancer patients. Conventional manual methods are labour-intensive and require specialist expertise, limiting their routine clinical use. Therefore, this study serves as a feasibility and pilot investigation to explore the potential of deep learning-based automated regression for body composition analysis within a clinical workflow. Methods: Four deep learning architectures (AlexNet, UNet, GoogLeNet, and ResNet34) were trained to predict SMA, SMD, subcutaneous fat area (SFA), and visceral fat area (VFA) from CT scans of colorectal cancer patients. Systematic hyperparameter optimization identified the most accurate models, which were subsequently implemented in a web application for clinical use. Results: GoogLeNet achieved the best performance, with a mean percentage error (PE) of 4.96% for SMA prediction, while AlexNet reached 8.12% for SMD. Independent testing demonstrated robust accuracy, correctly classifying body composition metrics in 80% of cases. The web application delivered rapid and consistent outputs, supporting integration into clinical workflows. Conclusion: Optimized deep learning models, particularly GoogLeNet and AlexNet, can automate CT-derived body composition analysis with a Mean Percentage Error (PE) of 4.96% for SMA and 8.12% for SMD. These tools have the potential to streamline clinical practice by reducing the time and expertise required for manual segmentation. Further validation in larger, more diverse datasets is warranted.

0.10

Underwater Color Restoration with Vanishing Uncertainty

eess.IV cs.CV ·2026-08-16 ·Grigory Solomatov, Derya Akkaynak
Abstract

Underwater color restoration promises to unlock color as a reliable signal for aquatic sciences, but achieving this with scientific confidence remains out of reach. Current methods are validated almost exclusively on an empirical basis, which provides confidence only to the extent that the vast diversity of possible visibility conditions is covered with end-to-end testing using a known ground truth. This is exacerbated by color restoration being a fatally ill-posed problem when considered in full mathematical generality, requiring additional constraints to narrow the solution to a finite uncertainty interval. The gap between which constraints suffice in theory and which constraints are satisfied by real-world data is poorly understood, making it unclear whether existing methods are solving a problem that is actually solvable. In this article, we investigate the theoretical side of this gap, identifying idealized conditions which guarantee bounded uncertainty that converges to zero as the spatial resolution of the camera increases.

0.04