CS Paper Radar

Daily listing

2026-10-22 · eess.IV

13 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 11

Vision Transformers for Estimating Irradiance Using Data Scarce Sky Images

eess.IV cs.AIcs.CVcs.LG ·2026-10-22 ·David Hamlyn, Sunny Chaudhary, Tasmiat Rahman
publishedhighly cited
Abstract

Accurate estimation of diffuse horizontal irradiance (DHI) is critical for optimising photovoltaic system performance and energy forecasting yet remains challenging in regions lacking comprehensive ground-based instrumentation. Recent advancements using Vision Transformers (ViTs) trained on extensive sky image datasets have shown promise in replacing costly irradiance measurement equipment, but the scarcity of long-term, high-quality sky imagery significantly restricts practical implementation. Addressing this critical gap, this study proposes a novel dual-framework approach designed for data-scarce scenarios. First, calculated atmospheric parameters, including extraterrestrial irradiance and cyclic time encodings, are integrated to represent sky conditions without utilising any instrumentation. Next, a sequential pipeline initially predicts synthetic global horizontal irradiance (GHI) and uses it as a feature, to refine DHI estimation. Finally, a dual-parallel architecture simultaneously processes raw and overlay-enhanced fisheye sky images. Overlays are generated through unsupervised, physics-informed cloud segmentation to highlight dynamic sky features. Empirical validation is performed using data from the Chilbolton Observatory, chosen for its temperate climate and frequent cloud variability. To simulate data-scarce conditions, models are trained on a single month (e.g., January) and evaluated across a temporally disjoint, full-year test set. Under this setup, the sequential and dual-parallel frameworks achieve RMSE values within 2-3 W/m^2 and 1-6 W/m^2, respectively, of a state-of-the-art ViT trained on the complete dataset. By combining physics-informed modelling with unsupervised segmentation, the proposed method provides a scalable and cost-effective solution for DHI estimation, advancing solar resource assessment in data-constrained environments.

0.56

Bound-Conditioned Latent Inference for Progressive Image Compression

eess.IV cs.CV ·2026-10-22 ·Jaeseok Jang, Seungmin Jeon, Kwang Pyo Choi, Chang-Su Kim
top venue
Abstract · Accepted to NeurIPS 2026

Progressive image compression reconstructs images from prefixes of a single bitstream and therefore involves sequential latent inference under partial observations. Existing trit-plane codecs mainly treat decoded trits as discrete symbols for probability prediction, without fully exploiting their role as interval constraints on the underlying continuous latents. We propose bound-conditioned latent inference (BLI), a framework that reformulates progressive trit-plane coding as sequential latent inference under shrinking interval constraints. At each coding step, the trits decoded so far define lower and upper bounds for each latent element. BLI uses the center and width of these bounds, together with hyperprior information shared by the encoder and decoder, to jointly refine the Gaussian parameters $(μ,σ)$ for entropy modeling and the latent estimate $\hat{y}$ for reconstruction. As additional trits are decoded, the feasible intervals shrink monotonically, yielding tighter constraints for the next inference step and enabling flexible in-plane refinement schedules. Experiments on Kodak, CLIC, and JPEG-AI show that BLI achieves state-of-the-art rate-distortion performance among progressive image codecs, reducing BD-rate by $17.78\%$ over DPICT and by $7.96\%$ over CTC on Kodak, while replacing CTC's plane-specific predictors with a shared model that uses about $5.3\times$ fewer parameters and achieves lower latency than CTC.

0.41

CVP-BAA: Efficiently Adapting Segment Anything Model for Medical Image Segmentation

eess.IV ·2026-10-22 ·Mei Wang, Minghui Li, Libin Lan
code/data
Abstract · Submitted to CVIU, 35 pages, 8 tables, 8 figures. Our code is available at \href{https://github.com/WangMei-wm/CVP-BAA}{here}

Various task-specific medical segmentation models have demonstrated strong performance, their heavy reliance on extensive annotations and highly specialized architectures limits their versatility, scalability, and clinical applicability. Recently, adapting vision foundation models, particularly the segment anything model (SAM), has emerged as a promising alternative. However, prevalent parameter-efficient fine-tuning (PEFT) strategies, such as prompt tuning and adapter tuning, often lack an explicit mechanism to embed local structural priors into the long-range dependency modeling of vision transformers (ViT), rendering them insufficiently sensitive to fine-grained details. To address these limitations, we introduce CVP-BAA, a novel hybrid PEFT method that improves SAM's sensitivity to domain-specific textures and local details, leading to superior boundary delineation. The proposed CVP-BAA adopts two key ideas. First, it introduces a convolutional visual prompting (CVP) strategy that leverages convolutional features as structural priors, prepending them to the key and value projections within the multi-head self-attention layers of strategically selected ViT blocks. Through a dedicated prompt generation-and-injection module, this mechanism effectively bridges local spatial details with global context semantics. Second, a boundary-aware adapter (BAA) is designed as a parallel branch to the feed-forward network within the same selected blocks. By explicitly computing and amplifying high-frequency components, the BAA enhances feature representations along tissue boundaries and fine-grained lesion structures. Extensive experiments on five benchmarks across three imaging modalities demonstrate that CVP-BAA achieves superior segmentation performance, surpassing existing task-specific models and PEFT-based SAM adaptations in both quantitative metrics and qualitative results.

0.38

Simulated transcranial ultrasound of human language cortex: verifying heard speech needs far less data and signal than decoding it

eess.IV q-bio.NC ·2026-10-22 ·Omer Shalev
code/dataunusual
Abstract · 4 pages + references, 3 figures. Code: https://github.com/deShal3v/verify-vs-decode-ultrasound

Functional ultrasound could image cortical blood volume through the temporal bone, but the skull leaves a weak signal, and task-evoked cortical imaging through the intact adult skull has not yet been shown. We built a voxel-specific Monte Carlo link-budget simulation of a probe on the left temple and used it to degrade public fMRI of three people who heard 15 hours of stories. On the same anatomical voxels we trained a published state-of-the-art fMRI language decoder (Tang et al., 2023) and two verifiers that only check a candidate text. In clean data the verifiers needed far less training (11 to 12 minutes against 3.2 to 6.6 hours), but all three learned at a similar rate. Noise changed this qualitatively: the verifiers kept gaining evidence while the decoder slowed and, under simulated transcranial physics, stalled, whereas the verifiers still reached their goal under a favorable simulated link budget. This asymmetry suggests that low-SNR modalities such as transcranial ultrasound may support verification well before decoding.

0.36

QICOM: Open-Source Software for Reproducible Image Quality Evaluation, Blinded Assessment, and Radiomic Comparison

eess.IV cs.AI ·2026-10-22 ·Fabio Mattiussi, Switinder Ghotra
code/data
Abstract

QICOM (Quality Image COMparator) is open-source software for quantitative image comparison, paired radiomics, and blinded assessment. It saves processing settings, image identities, measurements, and response mappings so a comparison can be reopened and recalculated. We evaluate reference agreement, responses to controlled perturbations, and recovery of saved analyses. Synthetic experiments cover 37 quantitative descriptors using independentnumerical references and separate upstream integration comparisons. The QICOM/MIRP backend meets the reference tolerances for all 482 numeric IBSI 1 digital-phantom entries and all 1,622 entries across configurations A-E of the public CT reference case; these comprise 1,804 feature/aggregation comparisons and 300 preprocessing diagnostics. Restricting masked SSIM and HFEN to complete kernel support removes the observed dependence on excluded pixels. In a synthetic filtering example, stronger smoothing increases SSIM while worsening MSE and HFEN relative to milder smoothing and changing GLCM contrast more strongly. Reopened radiomics projects reproduce all 43 feature pairs per comparison, and two blinded deliveries return four correctly mapped scripted responses. These experiments document the calculations and data transfers linking the three workflows.

0.30

GWDM: A Guided Wavelet Diffusion Model for Realistic Histopathology Image Generation

eess.IV ·2026-10-22 ·Abdullah, Tao Huang, Ickjai Lee, Lei Bi, Euijoon Ahn
benchmark
Abstract · 14 pages, 5 Figures, 5 Tables

Histopathology images are recognized as a reliable and comprehensive modality for Deep Learning (DL) based diagnosis. However, effectiveness is constrained by limited large-scale annotated datasets, as collecting expert-labeled medical data is costly and time-intensive. Recent advances in generative models, particularly diffusion models, demonstrate strong capabilities in synthesizing medically relevant content for dataset augmentation. Existing generative frameworks treat histopathology patches as generic natural images, failing to enforce biological constraints such as histomorphological structures and heterogeneous staining patterns essential for valid synthesis. We propose a guided wavelet diffusion model (GWDM) framework that captures image details at multiple scales using wavelets and leverages controllable conditioning based on domain-specific histopathological features (e.g., tissue patterns and color variations). We further formulate a histomorphological guidance loss applied to real and generated patches. A loss ramping strategy gradually introduces these constraints during training, ensuring stable optimization and robust modeling of tissue architecture. GWDM was evaluated on three benchmark datasets (BCSS, MoNuSeg, and PAIP2019), consistently outperforming state-of-the-art generative methods. Ablation studies confirmed that domain-guided conditioning, perceptual loss, and structural similarity loss each contribute meaningfully to synthesis quality. Downstream nuclei and tissue segmentation experiments further validated the clinical utility of GWDM-generated images, demonstrating consistent performance improvements when synthetic data augments real training sets. This work shows that domain-specific conditioning and dual-loss optimization generate realistic histopathology patches, reducing data scarcity and improving clinical downstream segmentation performance.

0.27

GateFormer: Forecast-Space Decomposition for Intra-Hour Solar Irradiance Prediction from Sky Images

eess.IV cs.AIcs.CVcs.LG ·2026-10-22 ·David Hamlyn, Sunny Chaudhary, Jonathon Hare, Tasmiat Rahman
publishedbenchmark
Abstract

Sub-hourly dispatch, balancing, and storage control increasingly depend on forecasts that anticipate rapid variability in solar generation. Accurate sky-image-based irradiance forecasting requires a combination of visual cloud dynamics with recent irradiance state while adapting to different short-term irradiance-change regimes. To address this, we introduce GateFormer, a GHI-conditioned dual-decoder ViT for intra-hour global horizontal irradiance (GHI) forecasting through forecast-space decomposition. GateFormer embeds observed GHI into the visual token stream, allowing interaction with sky-image patch features through self-attention. From this shared representation, a Trajectory Head predicts future GHI sequence, while a Delta Head predicts final-horizon change from the latest observed GHI. The two final-horizon forecasts are adaptively weighted in prediction space, with magnitude- and direction-supervision targeting the remaining error. On the NREL-TSI benchmark, GateFormer attains 125.01 W/m^2 RMSE at +30 min, improving over a state-of-the-art transformer baseline by 9.6% under paired-timestamp evaluation. Across NREL-TSI, Chilbolton, and SIRTA, GateFormer achieves the lowest final-horizon RMSE among the evaluated baselines, with forecast skill of 22.97-28.86% relative to smart persistence. Component ablations show adaptive weighting outperforms both individual decoders and fixed averaging, distinguishing GateFormer from conventional forecast combination, while the supervised correction further reduces RMSE by 1.68 W/m^2 and MAE by 4.86 W/m^2. Ramp-regime diagnostics show larger gains during operationally important positive ramps, reducing RMSE by 26.27 W/m^2. These results identify forecast-space decomposition as an alternative forecasting formulation, with potential relevance to other multimodal short-horizon forecasting tasks and deployment using only sky images and measured GHI.

0.26

Self-Supervised Multibeam Sonar Restoration via Coherent Forward Modeling

eess.IV cs.CVeess.SP ·2026-10-22 ·Zixin Wang, James Hopgood, Mike Davies
Abstract · 16 pages, 8 figures, includes supplementary material

Multibeam imaging sonar produces intensity images degraded by coherent speckle and system-induced blur, while clean reflectivity targets are rarely available. Existing despeckling methods often rely on simplified intensity-domain noise models, synthetic clean targets, or blind-spot self-supervision, and typically do not jointly model deblurring and speckle suppression. We propose a physics-consistent self-supervised framework for joint despeckling and deblurring of multibeam imaging sonar. A stochastic coherent image-formation model yields a conditional-mean forward operator that relates latent scene reflectivity to expected intensity through the squared magnitude of the system point spread function. We then use registered multi-frame sonar sequences to train without clean ground truth images, showing that, under an idealized inter-frame conditional-mean condition, the expected paired loss equals the corresponding forward-prediction loss up to a network-independent constant. To stabilize the ill-conditioned inverse problem, we further adapt robust equivariant imaging using stochastic coherent simulation and introduce a paired forward prediction error metric for ground-truth-free evaluation. Experiments on two real multibeam sonar datasets demonstrate a favourable balance between forward-prediction agreement, homogeneous-region speckle suppression, and preservation of visible structural boundaries compared with representative baselines.

0.24

CoRE: Relating Fine-Grained Chest X-ray Findings in Anatomical Context

eess.IV ·2026-10-22 ·Minjun Kim, Jong Hak Moon
Abstract · 18 pages, 3 figures

Chest X-ray interpretation depends on both the anatomical location of findings and their relationships with other abnormalities. However, relations defined over global finding labels do not explicitly distinguish the same finding across anatomical locations. We propose CoRE(Co-occurrence-guided Region Evidence), a framework that incorporates relationships among findings and anatomical context into fine-grained chest X-ray prediction. It groups anatomical region-finding labels by co-occurrence and uses these groups to guide shared representation learning through visual prompt tuning on a frozen vision transformer. The predictions are supplemented by an anatomically supervised region-evidence stream through region-matched logit residuals. Experiments on MIMIC-CXR with Chest ImaGenome annotations show that CoRE improves region-finding classification over standard and relation-aware prompt-based baselines. Quantitative evaluations on MS-CXR and the Chest ImaGenome gold standard show improved finding localization, supported by qualitative comparisons. CoRE also improves finding-level classification on mapped finding labels in external VinDr-CXR and CheXpert datasets without target-domain adaptation. These results demonstrate the value of jointly modeling finding relationships and anatomical context for fine-grained chest X-ray analysis.

0.21

EL-DIP: A Deep Image Prior Framework for Accurate,Efficient, and Noise-Robust Elastography

eess.IV cs.CE ·2026-10-22 ·Hao Liu, Fuyi Li, Dong Liu, Yue Mei, Sheng Mao
Abstract

Elastography is a key technique for non-invasive imaging, yet it remains severely ill-posed and sensitive to measurement noise, causing blurring and artifacts. We propose EL-DIP, a training-data-free framework based on deep image prior (DIP) that reconstructs heterogeneous shear modulus distributions. Inverse distance weighting interpolation enables arbitrary-shaped domains, and adjoint sensitivity analysis provides efficient gradient computation. Numerical and experimental studies show that EL-DIP accurately recovers inclusion geometry and modulus across different noise levels. Under extreme noise, image fidelity improves by approximately 97.1% over conventional methods. We believe that this method has great potential as a robust tool for biomedical diagnosis,biomechanical characterization, and non-destructive evaluation.

0.20

H-2DGS: Height-Field Gaussian Splatting for Sharp and Deformable Neurosurgical Surface Reconstruction

eess.IV cs.CVcs.GR ·2026-10-22 ·Zhang Zichuan, Bart Brouwers, Rembrandt Bakker, Maud Landers, Geert-Jan Rutten +1 more
Abstract

Neurosurgical navigation commonly presents magnetic resonance imaging (MRI) as 2D slices, making it difficult to relate the anatomy in those slices to the cortical surface observed through the surgical microscope. We seek a common 3D visualization that combines a photorealistic reconstruction of the exposed cortex during tumor surgery with whole-brain MRI context and diffusion tractography pathways. This requires the reconstructed cortex to form a clear boundary around the brain anatomy rather than a diffuse volume that obscures internal structures. Conventional 3D Gaussian Splatting (3DGS) can reproduce observed views but, under limited surgical view coverage, may distribute opacity through a thick and geometrically ambiguous band. We introduce height-field 2D Gaussian Splatting (H-2DGS), a three-stage pipeline that concentrates a robust 3DGS reconstruction, fuses its depth into a shared truncated signed distance field (TSDF) surface, and represents that surface with curved, surface-oriented Gaussian primitives. Separate height, color, and opacity bases provide local geometry and appearance, while a neighbor-transition objective coordinates overlapping patches. The explicit surface further supports postoperative alignment: MRI-derived depth deforms the reconstruction, and tracked-color supervision with alternating optimization preserves its appearance. Across five real neurosurgical cases, H-2DGS gives low multi-view depth inconsistency, a compact 7.97MB representation, and interactive rendering at 29--42ms per frame. The resulting sharp, deformable surface integrates clearly with tractography and MRI anatomy, including a postoperative resection cavity.

0.11

Systems & Networking 2

Fast Path, Exact Path: One Library of Hardwired Operators for Streaming and Exact Canny Edge Detection on a Low-Cost FPGA

cs.AR eess.IV ·2026-10-22 ·Raj Mali
Abstract · 7 pages, 5 figures, 7 tables

Hysteresis edge tracking, the final stage of Canny edge detection, follows edge chains of unbounded length and therefore resists single-pass streaming; FPGA designs either approximate it or dedicate separate labelling hardware to it. We show that a single library of hardwired 3x3 operators, each with an identical two-clock latency, delivers both a camera-rate approximation and exact hysteresis on a low-cost Artix-7 (XC7A35T). The fast path streams camera pixels through the operators and K local hysteresis stages and commits each edge decision 262.15-720.63 microseconds after the pixel arrives (K = 1-8; system simulation with a datasheet camera model), that is, 3 + K camera lines later and 46-127x sooner than a frame-based processor can even begin at 30 frames per second. It provably never reports an edge that exact hysteresis rejects, recovers 76.6-96.1% of exact edges at thresholds 20/40, and on the 200 BSDS500 test images retains at least 98.6% of the exact path's boundary F-measure (ODS 0.470-0.477 versus 0.476). The exact path holds 128x128 tiles in block RAM, is exact within each tile, and replaces two-buffer iteration with in-place forward and reverse sweeps built into the same operator. This reduces hysteresis from 38-82 passes to 3-7 on pattern and photo tiles, accelerating the hysteresis step 6.6-21.7x (40x on a worst-case tile) and a complete tile 4.5-9.9x, with identical output. Both paths are bit-exact with software golden models at every pipeline stage and close timing at 50 MHz in at most 1455 LUTs. An optimised multi-core CPU remains faster on stored images, but it cannot begin until the frame is complete.

0.51

RV565: Cross-Layer Co-Design for Frame-Independent Video Playback on MicroPython-Class ESP32-S3 Systems

cs.AR cs.MMcs.PFeess.IV ·2026-10-22 ·Ayushman Bhattacharya, Anwesha Chakraborty
Abstract · 14 pages, 4 figures, 7 tables. Artifact: https://doi.org/10.5281/zenodo.23543367

Video on SPI-attached microcontroller displays is limited less by decoding than by where each byte lives and which stages run serially. We present RV565, a decode framework for frame-independent video whose decoded representation is the panel's native RGB565 format, and evaluate it on an ESP32-S3 with two ten-second windows of an openly licensed film. A serial path - inflate, then scale into internal-memory stripes overlapped with SPI direct-memory-access (DMA) transfers - meets the 41.7 ms deadline on the lighter window but misses all 7,200 frames of the heavier one. RV565's dual-core pipeline inflates the next frame on the second core during the transfer and sustains 24 FPS with zero misses and 10.3 ms of slack on both windows; frame time then equals the display transfer, which runs at 98.1% of the 40 MHz wire-time bound. Because frames are independent, inflation time is linear in the compressed length stored in the container (pooled r^2 = 0.9987): a model fitted on one window predicts the other within 0.04 ms and identifies from metadata alone which window the serial path cannot schedule. We show why Deflate cannot exploit co-located temporal redundancy in RGB565 frames larger than 128x128 pixels and measure the price: a shared Deflate stream changes size by at most 1.1%, whereas an explicit XOR delta would save 46-80%. Inside OreoOS, a MicroPython application operating system, firmware inflation alone reaches 12.2 FPS; stage timing attributes the 80.4 ms frame time to serialized filesystem input, external-RAM placement, and blocking presentation, with 0.8 ms of interpreter overhead. Firmware, measurements, and analysis scripts are released.

0.39