CS Paper Radar

Daily listing

2026-10-27 · physics.plasm-ph

3 papers first submitted this day (UTC) in physics.plasm-ph — physics.plasm-ph. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

AI & Machine Learning 3

Generative modeling for fusion: a large-scale benchmark of stellarator fast-ion simulations

cs.LG physics.plasm-ph ·2026-10-27 ·Misha Padidar, Teresa Huang, Mark Goldstein, Michael Czekanski, Jeffrey Soules
benchmark
Abstract

Stellarators offer a promising magnetic confinement approach for achieving controlled nuclear fusion. However, stellarator design remains challenging, as evaluating configuration performance requires computationally expensive, high-fidelity simulations. In particular, key performance metrics derived from guiding center simulations are costly to include directly in the design optimization loop, and are almost exclusively used as diagnostics. Machine learning has the potential to advance fusion research by enabling rapid generation and evaluation of new stellarator configurations. Effectively applying ML for fusion demands large-scale datasets that capture both design diversity and high-fidelity simulation outputs. In this work, we introduce the Benchmark of Stellarator Simulations (BoSS), a dataset of stellarator designs paired with guiding center simulation results and trajectories. The BoSS is the first large-scale dataset of guiding center simulations, containing simulation data for 180,000 distinct magnetohydrodynamic equilibria spanning a wide range of magnetic geometries and confinement properties. To exemplify the utility of ML to accelerate stellarator design, we formulate and address two sets of modeling tasks: generative modeling for designing stellarators with good particle confinement, and surrogate modeling for predicting stellarator heat deposition patterns and particle trajectories. The tasks reveal the potential impact ML can have in the stellarator field and important opportunities to improve the applicability of ML models in the sciences. Our baselines generate diverse, performant stellarators and provide useful surrogate predictions, and point to long-horizon trajectory forecasting and out-of-distribution generation as key directions for future work. The BoSS can be accessed through https://boss.flatironinstitute.org/.

0.30

Inverse modelling of a laser-plasma accelerator

cs.LG physics.acc-phphysics.plasm-ph ·2026-10-27 ·Mykyta Lenivenko, Arnaud Beck, Hayg Guler, Gueladio Kane, Sophie Kazamias +7 more
Abstract

The electron beams of a laser-plasma accelerator depend non-linearly on the laser and gas settings. This dependence is explored using particle-in-cell (PIC) simulations, and machine-learning models trained on these simulations predict the beam from the settings. Here we address the reverse problem: given a measured beam, which settings produced it? We infer three of them: the gas pressure $p\_1$, the normalised vector potential $a\_0$ and the nitrogen concentration $c\_{N\_2}$. The solution is not guaranteed to be unique. We train an ensemble of mixture density networks that, for each beam, output several possible sets of settings with their probabilities and uncertainties, and test them on simulated beams with realistic measurement noise. On average, the predictions are accurate ($R^2 = 0.91$), yet for about two-thirds of the beams the inferred distribution has two competing solutions. These share nearly the same value of $a\_0^2 p\_1$, which controls how strongly the laser focuses itself in the plasma and, in earlier PALLAS studies, when electrons start to be injected. Keeping this quantity fixed gives beams that are practically indistinguishable with realistic diagnostics. A forward model used as a check removes unphysical solutions but cannot choose between the two plausible ones. We then test two ways to resolve the ambiguity. Adding the full electron energy spectrum improves the mean prediction ($R^2 = 0.94$), mostly through $a\_0$. It changes the weights of the two solutions but does not move them. A second measurement at a deliberately different plasma density is more effective. In paired PIC simulations, it reduces the error on $a\_0$ by a factor of 2.6, whereas repeating the measurement at the same density brings almost no gain.

0.26

From Forecasting to Feedback: Evaluating Learned Dynamics for Tokamak Control

cs.AI physics.plasm-phcs.LG ·2026-10-27 ·Guoyang Shi, Siqi Ding, Xuanhe Wang, Pei Guo, Changquan Yu +5 more
Abstract

Learned temporal models are moving beyond offline forecasting toward interactive environments for decision making, yet logged-trajectory accuracy need not predict closed-loop behavior under policies optimized in the learned model. This forecasting-control gap matters in tokamak magnetic control, where coupled plasma-circuit dynamics and actuator constraints can amplify errors through feedback. Using a calibrated free-boundary Grad-Shafranov solver, we collect four datasets in a 2x2 design over physics-parameter and current-reference coverage. At matched budgets of 500, 1k, 3k, and 5k rollouts, we train 16 action-conditioned Transformers; PPO policies optimized in the 5k surrogates are then evaluated without adaptation on six reference-solver conditions. Only joint-coverage D4 shows monotonically decreasing cross-condition mean error, whereas D1 improves in distribution but degrades out of distribution. Binary completion masks substantial closed-loop differences: D2-D4 each complete 83.3% of conditions, but reach on average 99.0%, 94.7%, and 90.5% of the evaluation horizon, while their worst conditions reach 94.2%, 68.2%, and 43.2%. Policies trained with action noise complete 5/24 matched conditions, compared with 19/24 under nominal training, and have a lower mean horizon-capped episode length. Based on one trained policy per configuration and one evaluation realization per condition, the results support combining prediction error, episode completion, condition-level duration, and tracking quality.

0.17