CS Paper Radar

Detecting Clear Contact Lenses for Iris Recognition: A Two-Stage Mask-Guided Attention Approach

Parisa Farmanifard, Arun Ross

cs.CV cs.AI ·submitted 2026-08-10 00:44 UTC · v1
benchmark

Abstract

This work focuses on the impact and detection of clear contact lenses in the context of iris recognition. While the detection of cosmetic or patterned contact lenses has been extensively studied under the presentation attack detection (PAD) paradigm, clear prescription contact lenses, that are typically transparent, have received comparatively less attention despite their widespread use. Unlike patterned lenses, clear lenses introduce no salient texture artifact, making them difficult to detect and are often assumed to have no impact on iris recognition. We first examine this assumption using the commercial VeriEye matcher on four benchmark datasets and show that clear lenses marginally degrade genuine match scores and increase verification error. We then propose a two-stage contact-lens detection framework. Stage~1 uses an existing PAD model to identify patterned lenses, while Stage~2 focuses on the more challenging clear-lens versus no-lens distinction using a ConvNeXt-Base model equipped with Mask-Guided Spatial Attention (MGSA). The proposed MGSA module incorporates a Hough-derived anatomical ROI mask together with learned spatial attention and Squeeze-and-Excitation channel recalibration, allowing the network to focus on subtle limbal cues associated with clear lens wear. Across four datasets, the full pipeline consisting of both patterned and clear contact lens detection achieves between 90.0\%--98.8\% accuracy. Finally, we introduce a z-score calibration method that adjusts VeriEye match scores when a clear lens is detected in the input images. This calibration reduces EER by 4.1\%--28.3\% across datasets, demonstrating that reliable clear contact lens detection can directly improve iris verification performance.

Closest papers

Nearest neighbours by meaning across the whole index.

Diff-IrisPAD: Modeling Bona Fide Iris Distributions for Unsupervised Presentation Attack Detection

cs.CV ·2026-10-21 ·Geetanjali Sharma, Harsh Yadav, Tanmay Deshpande, Shubham Ashwani, Aditya Nigam +1 more
published similarity 0.61
Abstract · 10 pages, Accepted at IJCB Conference 2026

Iris recognition systems are vulnerable to presentation attacks (PAs), including textured contact lenses, print replays, and synthetic irises. Existing PAD methods rely on supervised learning with attack data, limiting generalization to unseen attacks and new sensors. We propose Diff-IrisPAD, an unsupervised framework based on Brownian Bridge Diffusion that models bona fide iris distributions without using attack samples. The method reconstructs clean iris textures from degraded inputs and detects attacks via reconstruction inconsistency using ViT scoring and pixel-level measures. Experiments on a large-scale multi-sensor dataset (125K+ images, NIR and VIS, 8 attack types) show that Diff-IrisPAD achieves an overall ACER of 30.52, significantly outperforming diffusion-based baselines while demonstrating strong generalization to unseen attacks. These results highlight the effectiveness of diffusion-based bona fide modeling for robust and scalable iris PAD.

0.38

Compact Vision Models for Iris Presentation Attack Detection under Presentation Attack Instrument Shift and Environmental Degradation

cs.CV cs.CR ·2026-09-17 ·Athanasios Angelakis, Marta Gomez-Barrero
publishedbenchmark similarity 0.57
Abstract · Accepted at BIOSIG 2026. This preprint includes minor nomenclature and editorial corrections clarifying the project-specific Patch-ABMIL and…

Iris presentation attack detection (PAD) is security-critical when a subsystem that appears reliable during development encounters presentation attack instruments (PAIs) or acquisition conditions absent from validation data. We benchmark three compact scratch-trained computer-vision models, each with at most approximately 0.26 million trainable parameters, on the Notre Dame subset of LivDet-Iris 2017 under PAI-driven domain shift and environmental degradation. All models are trained without external pretraining or data augmentation and evaluated over five seeds. A validation-selected threshold is transferred unchanged to the known-attack, unknown-attack, corrupted, and pooled test partitions. From known to unknown attack presentations, Attack Presentation Classification Error Rate (APCER) increases by 17.11-30.47 percentage points and Detection Equal Error Rate (D-EER) increases by 7.38-12.73 percentage points. At the validation-selected threshold, ZACH-ViT obtains the lowest unknown-attack APCER (47.69 +/- 4.84%) and D-EER (38.87 +/- 0.93%), while Compact-TransMIL obtains the lowest Bona Fide Presentation Classification Error Rate (BPCER). ZACH-ViT also gives the lowest unknown-attack BPCER at an APCER limit of 10% (81.29 +/- 1.95%). The high absolute errors show that the comparative advantage of the best compact model does not constitute deployment readiness under unknown PAIs.

0.55

Lensless Gaze Is Not Private by Default: Auditing Identity Leakage Across Disclosure Surfaces

cs.CV ·2026-08-31 ·Rahul Vimalkanth, Kaushik Mitra
code/data similarity 0.55
Abstract · 16 pages, 5 figures. Code available at https://github.com/xoxo121/Lensless-Gaze-Is-Not-Private-by-Default

Lensless near-eye sensing is often described as privacy-friendly because its coded measurements are visually unintelligible. Yet visual unintelligibility reflects human interpretation, not what a learned adversary can recover. We therefore treat identity privacy as a systems property of disclosure surfaces: representations crossing sensing, storage, computation, and output boundaries. We audit a simulated lensless gaze pipeline under a 36-subject known-gallery closed-set identification protocol with a fixed, known PSF; privacy from an unknown or varying optical key is outside our scope. Reported accuracies are empirical attack success rates under matched linear and MLP probes and do not upper-bound stronger adversaries. Simulated lensless measurements yield 96.7% top-1 identification versus 97.7% for matched original eye crops, while an MAE embedding retains 94.3%. Compression alone offers little protection: 8-D PCA and a matched 8-D bottleneck retain 93.2% and 91.8%, whereas separately trained 8-D GSPL bottlenecks yield 77.5% mean recovery across three seeds. A released 128-way gaze token lowers single-frame recovery to 38.1%, while its residual and continuous gaze output expose 62.1% and 72.6%, respectively. Under a source-frame-disjoint tiled protocol, token summaries reach 39.9% at T=25, showing that repeated-output risk depends on representation and aggregation. These rates reflect all subject-correlated information in the evaluated dataset, including acquisition and behavioral cues, rather than isolating intrinsic ocular biometrics. Ordinary least squares residualization against a six-dimensional crop geometry and intensity summary still leaves lensless recovery at 95.1%. Our results show that privacy claims for lensless sensing must be tested at disclosure boundaries rather than inferred from appearance.

0.34

Where to Predict in Retinal OCT? Anatomy-Guided Target Selection for I-JEPA

cs.CV ·2026-11-12 ·Yunchu Feng, Wai Tak Lau, Kaveri A. Thakoor
published similarity 0.54
Abstract · 18 pages. Accepted as a poster at the GenAI for Health Workshop at NeurIPS 2026 (non-archival)

Self-supervised learning aims to learn meaningful representations from unlabeled data, potentially allowing models to capture subtle anatomical variations across patients and reduce the amount of labeled data needed. Image-based Joint-Embedding Predictive Architecture (I-JEPA) learns by predicting target-region representations from visible context rather than reconstructing pixels. However, its uniform target placement does not account for the anatomical structure of retinal OCT, where retinal tissue occupies only part of each B-scan. We investigate anatomy-guided target selection using image intensity and predicted retinal segmentation while retaining the I-JEPA architecture and latent prediction objective. We compare anatomy-guided rectangular targets, anatomy-shaped targets and coverage-constrained placement with uniform masking, and evaluate the learned representations using linear probing for glaucoma classification on FairVision. We found that rectangular targets guided by image intensity achieved the highest linear-probe AUC in our comparisons. We show that anatomically meaningful target selection is promising for retinal OCT representation learning, while greater anatomical specificity did not consistently improve performance.

0.35

EyeVQA: Benchmarking Ophthalmic Vision-Language Models from Recognition to Spatial Grounding

cs.CV cs.AI ·2026-09-26 ·Gujie Shao, Zixun Xie, Xuechun Xing, Ruixiang Wang, Ziyun Lan +5 more
publishedbenchmarkcode/data similarity 0.53
Abstract · Accepted to MICCAI 2026 CREATE Workshop. 19 pages, 2 figures, 2 tables. Project page: https://github.com/PKUTHM/EyeVQA

Vision-language models (VLMs) have shown increasing potential for medical image understanding, yet their capabilities in ophthalmic imaging remain insufficiently characterized. Existing ophthalmic datasets are typically designed for individual diseases or specialized tasks, making it difficult to systematically evaluate whether VLMs can move beyond disease recognition toward comparative reasoning and fine-grained spatial grounding. We introduce EyeVQA, a unified visual question answering benchmark for comprehensive evaluation of ophthalmic VLMs. EyeVQA is constructed from 21 available ophthalmic datasets and contains 20,000 question-answer pairs spanning six disease groups and seven question types: Single-Choice, Multi-Select, Variable-Select, True-False, Ranking, Point Location, and Bounding Box. Gold answers are deterministically derived from source-provided diagnoses, severity grades, clinical findings, segmentation masks, bounding boxes, and anatomical landmarks, enabling reproducible evaluation without relying on model-generated annotations. Notably, 44.5% of the questions require reasoning across multiple images, extending evaluation beyond conventional single-image medical VQA. We benchmark fourteen representative general-purpose, scientific, and medically specialized VLMs under a unified zero-shot protocol. The best-performing model only achieves an overall score of 62.8, while substantial gaps remain in spatial grounding and cross-task generalization. These results highlight the limitations of current VLMs in comprehensive ophthalmic visual understanding and establish EyeVQA as a diagnostic benchmark for developing more reliable and spatially grounded ophthalmic multimodal models. The project page is available at https://github.com/PKUTHM/EyeVQA.

0.42

OptiModNet: A UNet-Transformer Hybrid with Grouped-Query and Channel Attention for Optic Disc and Cup Segmentation

cs.CV cs.AI ·2026-08-19 ·Soumili Ghosh, Debapriya Roy, Aryan Das, Bikash Santra
code/data similarity 0.53
Abstract

Precise segmentation of the optic disc and cup is critical for the early detection and diagnosis of glaucoma. However, achieving consistently high performance across datasets while maintaining low computational requirements remains a significant challenge. In glaucoma detection, low-computation methods are crucial for enabling rapid, large-scale screening and facilitating deployment in resource-limited clinical environments. While deep learning models such as UNets, Vision Transformers (ViTs), and Diffusion models have demonstrated strong segmentation performance but these methods often come with substantial computational overhead. UNets are efficient at capturing local features but are limited in modeling global contextual information. Conversely, ViTs excel at long-range dependency modeling but are computationally intensive. Hybrid architectures, such as UNetR, which combine transformer-based encoders with UNet-style decoders, have shown improved performance but while incurring additional complexity. Considering these, in this work, we propose OptiModNet, a light weight novel hybrid architecture tailored for optic disc and cup segmentation. The model integrates diverse attention mechanisms at multiple stages of the network to enhance both local and global feature representation. We include an Aggregated Pyramid Loss that supervises predictions at multiple decoder depths, to promote better gradient flow and structural consistency. We evaluate OptiModNet on the REFUGE2 dataset for both optic disc and cup segmentation tasks. Our method achieves state-of-the-art performance, exceeding existing approaches by over 2.5\%, while maintaining high efficiency with only 3.73 GFLOPs and 1.93M parameters. The code is available at https://github.com/SG1947/OptiModNet.

0.24

CVP-BAA: Efficiently Adapting Segment Anything Model for Medical Image Segmentation

eess.IV ·2026-10-22 ·Mei Wang, Minghui Li, Libin Lan
code/data similarity 0.53
Abstract · Submitted to CVIU, 35 pages, 8 tables, 8 figures. Our code is available at \href{https://github.com/WangMei-wm/CVP-BAA}{here}

Various task-specific medical segmentation models have demonstrated strong performance, their heavy reliance on extensive annotations and highly specialized architectures limits their versatility, scalability, and clinical applicability. Recently, adapting vision foundation models, particularly the segment anything model (SAM), has emerged as a promising alternative. However, prevalent parameter-efficient fine-tuning (PEFT) strategies, such as prompt tuning and adapter tuning, often lack an explicit mechanism to embed local structural priors into the long-range dependency modeling of vision transformers (ViT), rendering them insufficiently sensitive to fine-grained details. To address these limitations, we introduce CVP-BAA, a novel hybrid PEFT method that improves SAM's sensitivity to domain-specific textures and local details, leading to superior boundary delineation. The proposed CVP-BAA adopts two key ideas. First, it introduces a convolutional visual prompting (CVP) strategy that leverages convolutional features as structural priors, prepending them to the key and value projections within the multi-head self-attention layers of strategically selected ViT blocks. Through a dedicated prompt generation-and-injection module, this mechanism effectively bridges local spatial details with global context semantics. Second, a boundary-aware adapter (BAA) is designed as a parallel branch to the feed-forward network within the same selected blocks. By explicitly computing and amplifying high-frequency components, the BAA enhances feature representations along tissue boundaries and fine-grained lesion structures. Extensive experiments on five benchmarks across three imaging modalities demonstrate that CVP-BAA achieves superior segmentation performance, surpassing existing task-specific models and PEFT-based SAM adaptations in both quantitative metrics and qualitative results.

0.38

Robust retinal biometrics for patient identity verification and retrieval across age and imaging devices

cs.CV ·2026-08-31 ·Jose D. Vargas-Quiros, Dennis Bontempi, Jeroen Vermeulen, Bart Liefers, Sven Bergmann +1 more
similarity 0.53
Abstract

Patient identity errors can compromise longitudinal medical records, research databases, and downstream clinical decisions. We present a retinal biometric system for verifying claimed identities and retrieving the correct identity from color fundus images. We trained a 512-dimensional metric-learning encoder combining a ConvNeXtV2 backbone with ArcFace and triplet losses on 227,004 images from 21,851 patient-eye identities in the Rotterdam Study, spanning multiple imaging devices and up to 32.6 years of follow-up. The system was evaluated on held-out Rotterdam Study data and externally on the UK Biobank and Age-Related Eye Disease Study (AREDS). Before evaluation, we used the model to screen for identity inconsistencies and manually adjudicated flagged images, identifying incorrect assignments in 0.588% of Rotterdam Study images, 0.259% of UK Biobank images, and 0.164% of AREDS images. In retrospective-only verification after removing near-duplicate images, the system achieved AUROCs of 0.9998, 0.9997, and 0.9998 in the Rotterdam Study, UK Biobank, and AREDS, respectively. For identity retrieval using only previously acquired images, Recall@1 was 99.7%, 97.2%, and 97.6%, respectively, from galleries averaging 4436-8510 identities; the correct identity appeared among the top five results in at least 98.6% of cases. Performance remained robust across imaging devices and long follow-up intervals, while lower image quality and inconsistent retinal fields accounted for most failures. These findings establish retinal anatomy as a durable biometric signal, useful for safeguarding the integrity of longitudinal imaging records.

0.14