CS Paper Radar

Dual-Domain Cross-Modal Decoding for Clinical Text-Guided Medical Image Segmentation

Md Maklachur Rahman, Tracy Hammond

cs.CV cs.AIeess.IV ·submitted 2026-08-11 18:40 UTC · v1
top venuecode/data

Abstract

Clinical text can narrow down what to segment, but recent text-guided designs emphasize spatial alignment while overlooking frequency content that governs texture and boundaries. We propose Dual-Domain Cross-Modal Decoding (DD-CMD) for clinical text-guided pulmonary infection segmentation, integrating two complementary forms of language guidance during decoding. In the spatial domain, Text-Guided Spatial Cross-Attention (TGSA) aligns multi-scale visual tokens with text semantics and updates features through gated residual fusion. In the frequency domain, Spectral-Text Adaptive Modulation (STAM) applies a 2D DCT to compute learnable band-energy statistics and predicts text-conditioned FiLM parameters to recalibrate decoder channels for frequency-aware decoding. DD-CMD embeds TGSA and STAM into a coarse-to-fine decoder (7x7 to 56x56) and restores full-resolution masks using a lightweight two-stage refinement module. Experiments on QaTa-COV19 and MosMedData+ show that DD-CMD achieves 91.46% Dice / 84.26% mIoU and 81.95% Dice / 69.42% mIoU, respectively, with average gains of +1.96 Dice and +2.67 mIoU over the strongest prior baselines. Code: https://github.com/maklachur/DD-CMD.

Comment
Accepted at MICCAI 2026 (Main). Final version to appear in the MICCAI 2026 proceedings

Closest papers

Nearest neighbours by meaning across the whole index.

Multimodal Routing and Region Refinement for Language-Guided Medical Image Segmentation

cs.CV cs.LG ·2026-09-24 ·Md Maklachur Rahman, Md Hasan Al Banna, Saraf Anjum, Assame Arnob, Tracy Hammond
publishedcode/data similarity 0.69
Abstract · Accepted at MICCAI 2026 (TIA). Final version to appear in the proceedings

Textual descriptions can reduce ambiguity in medical image segmentation by specifying the finding and location to be delineated. Existing text-guided methods mainly improve where image and language features interact but generally retain a single learned update pathway across all image-text pairs. We propose MRSeg, a parameter-efficient framework that uses each image-text pair to route the adaptation of visual and textual features before dense prediction. Frozen ConvNeXt-Tiny and PubMedBERT encoders provide multiscale visual features and clinical text tokens. A joint router uses the deepest visual feature and pooled text to predict a sparse mixture over low-rank adapter bases. The resulting route is shared across separate adapter banks for two visual scales and text, coordinating their adaptation while keeping the feature-specific parameters separate. Region Bridge uses text-derived queries to aggregate dense visual tokens into latent regions, refines these regions through self-attention and text cross-attention, and redistributes the refined information back to the feature maps. Finally, a multiscale decoder combines refined semantic features with shallow image evidence. On QaTa-COV19 and MosMedData+, MRSeg achieves 90.90/83.32 and 81.53/68.82 Dice/mIoU, respectively, with 7.11M trainable parameters and 7.60 GFLOPs. Code: https://github.com/maklachur/MRSeg.

0.40

CGSM: Concept-Guided Segmentation Model for Precise Pulmonary Lesion Delineation

cs.CV ·2026-09-07 ·Changheng Lin, Wenjie Zhang, Yushan Lu, Xinyue Yan, Xiao Jia +1 more
similarity 0.68
Abstract

Accurate segmentation of pulmonary lesions is essential for effective clinical diagnosis and treatment strategies. Existing segmentation approaches often lack task-specific semantic guidance, as text-based annotations typically offer coarse localization of lesions, leading to inadequate delineation of lesion boundaries and poor performance on small-scale lesions. To address this, we propose CGSM, a Concept-Guided Segmentation Model that integrates LLM-generated and clinically reviewed concepts into the segmentation process. Specifically, we design a Concept-Visual Alignment Module (CVAM) to activate relevant tokens within the concepts that align with visual features, enhancing the interaction between textual and visual information. In addition, we introduce a Concept Modulated Decoder (CM-Decoder), which uses concepts from CVAM as modulation signals to facilitate the adaptive fusion of image and text features, improving the segmentation accuracy. Extensive experiments on two public datasets show that CGSM achieves state-of-the-art performance, with results of 91.59% Dice and 84.49% mIoU on the QaTa-COV19 dataset, demonstrating its effectiveness in pulmonary lesion segmentation.

0.09

Reliability-Guided Vision-Language Decoding with Text-Aware Skip Refinement for Medical Image Segmentation

cs.CV ·2026-10-20 ·Sivan Talaei, Fatemeh Daneshfar, Abdulhady Abas Abdullah, Mourad Oussalah
code/data similarity 0.67
Abstract

Medical image segmentation remains challenging when targets exhibit limited visual distinction, irregular structure, or substantial variation across imaging modalities. Medical text can reduce this ambiguity, but indiscriminate fusion may introduce unreliable guidance. We present RELiF, a vision--language framework that integrates text through reliability-guided decoding. Its Reliability-guided Fusion Gate (RFG) adaptively controls cross-modal updates, while the Text-guided Skip Refinement Adapter (TSRA) refines high-resolution features using text guidance. RELiF is evaluated on radiographic, CT, and endoscopic segmentation tasks, where it shows competitive performance across diverse imaging characteristics and target appearances. Additional analyses examine efficiency and stability. The complementary uncertainty representation derived from the reliability response also shows an association with prediction difficulty, with higher uncertainty values occurring more frequently in pixels associated with segmentation errors. Code: https://github.com/SeivanTalaie/RELiF.

0.38

Expandable Modality Experts for Medical Vision-Language Learning

cs.CV ·2026-10-21 ·DM BAPPY, Eunsu Kim, Hanjoo Lee, Sung Hak Lee, Sangjeong Ahn
benchmark similarity 0.65
Abstract · 11 pages (main text), 42 pages (supplementary material), 2 main figures. Submitted to ICLR 2027

Learning across medical imaging modalities requires making use of images without paired text and accommodating new domains while retaining existing representations. We propose a medical vision-language technique built around an expandable bank of modality experts. Its Multiway Transformer combines shared visual computation with deterministically routed feed-forward experts and a separate text pathway. A modality-aware visual tokenizer supplies targets for masked pretraining on 19.4 million unpaired image rows across seven modalities; contrastive alignment then uses 3.23 million image-text pairs. Additional fundus and optical coherence tomography experts learn from paired data while the original image and text embedding paths remain frozen. With a ViT-Large backbone, the proposed technique achieves the best or tied-best result in 24 of 25 benchmark settings across nine modalities: 10 of 11 zero-shot classification benchmarks, all 10 linear probes, and all four retrieval benchmarks. Mean balanced accuracy is 0.674 for zero-shot classification and 0.856 for linear probing, and mean bidirectional retrieval recall is 20.70%. A separate three-seed sequential experiment with matched adaptation data yields fundus and OCT retrieval gains of 14.95 and 9.31 percentage points, with no measured loss on preceding fundus or pathology tasks. The preservation argument requires unchanged existing computation paths and inference conditions, and feature-identity checks verify retention on evaluated inputs. The proposed technique provides a modular approach to learning and expanding medical vision-language representations.

0.21

MedUP: Awakening Unified Understanding and Perception in Medical Vision-Language Models

cs.CV cs.AI ·2026-08-11 ·Yuan Wang, Hualiang Wang, Yixin Chen, Songtao Jiang, Shujian Gao +4 more
similarity 0.65
Abstract · 10 pages, 6 figures

Medical Vision-Language Models (Med-VLMs) excel at verbalizing visual content, yet precise visual perception, segmentation, and grounding remain challenging. Existing approaches either verbalize regions as coordinate strings or rely on external modules that decouple perception from understanding, creating representation gaps for region-language alignment. We present MedUP, a Med-VLM that natively unifies perception and understanding within a shared token space. At its core lies UniMedTok, a region tokenizer that encodes masks as discrete tokens in the LLM vocabulary, enabling the model to seamlessly interleave mask tokens with text. We curate UniMed-Train, a 1.84M-instance corpus spanning text-guided segmentation, region-grounded understanding, medical VQA and CoT-based segmentation, and introduce UniMed-Bench for unified evaluation. Extensive experiments show that MedUP outperforms native, agentic, and dual-decoder Med-VLMs across all tasks while remaining competitive with specialist segmentors, demonstrating the strong potential of unified understanding and perception modeling.

0.10

Text-Guided Medical Image Segmentation via Residual Aggregation and Dense Alignment Representations

cs.CV ·2026-10-10 ·Jie Gui, Hang Tu, Yunfeng Dou, Wen Sha, Xiuquan Du +1 more
publishedcode/data similarity 0.64
Abstract · Accepted at NeurIPS 2026 (poster)

Specifying segmentation targets with natural language provides flexible semantic conditioning for medical image segmentation. However, existing methods still struggle to reliably ground high-level textual semantics into accurate pixel-level spatial prompts, especially under low-contrast lesions, ambiguous boundaries, and visually similar anatomical contexts. In this paper, we propose RADAR (Residual Aggregation and Dense Alignment Representations), a parameter-efficient framework for text-guided medical image segmentation. RADAR explicitly decouples and synergizes the medical semantic anchoring capability of BiomedCLIP with the prompt-driven mask decoding ability of MedSAM2, while enabling low-cost task adaptation via LoRA. Specifically, Guided Residual Depth Aggregation adaptively aggregates cross-layer features under semantic guidance to alleviate delayed textual injection and deep semantic dilution. Structured Dense Representation Alignment leverages a frozen BiomedCLIP to construct crop-level target, boundary, and context anchors, improving the local discriminability of dense features and the reliability of automatic prompts. Multi-modal Prompt Generation further converts cross-modal semantic responses into composite text, point, and mask prompts for MedSAM2 decoding. Experiments on three public medical image segmentation datasets show that RADAR achieves competitive performance with only 0.74M trainable parameters, demonstrating its effectiveness in parameter-efficient adaptation, semantic grounding, and dense representation enhancement. The source code is available at https://github.com/JGuiidev/RADAR.

0.44

Guided Co-Attention with Adaptive Gating for Multimodal Medical Data Fusion

cs.CV cs.LG ·2026-11-07 ·Muntaqim Ahmed Raju, Priyanka Siddappa, Md Shifat Haider Al Amin, Ruizhe Ma, Md Ripon Ahammed
similarity 0.63
Abstract · IEEE BIBM 2026

Multimodal fusion requires not only exchanging information across modalities but also determining which representations should participate in the interaction and how complementary cross-modal views should be combined. We introduce Guided Co-Attention with Adaptive Gating, a fusion framework that integrates token-wise guidance, bidirectional cross-attention, and sample-specific fusion. The proposed method constructs two directional representations: an image-conditioned text representation, obtained by allowing textual tokens to query visual features, and a text-conditioned image representation formed in the reverse direction. Token-wise guidance modulates the representations before cross-attention, while an adaptive gate learns the relative contribution of the two resulting directional representations for each sample. We evaluate the approach using paired chest radiographs and radiology reports as an image-text test bed for binary (normal vs. abnormal) classification. The two cross-attention directions exhibit distinct performance characteristics, demonstrating that reversing the query and source modalities does not produce interchangeable representations. Ablation experiments further show that bidirectional interaction, adaptive gating, and token guidance provide complementary benefits. The proposed model achieves 96.05% accuracy, 96.10% F1-score, 98.37% AUC, 95.60% Sens@95Spec, and 96.51% Spec@95Sens, yielding the highest mean performance across all evaluated metrics. These findings support explicitly modeling interaction direction, token relevance, and sample-dependent integration when constructing multimodal representations.

0.16

ICGF-CXRMate: Image-Conditioned Clinical Context Compression and Gated Fusion for Chest X-ray Report Generation

cs.CV ·2026-10-22 ·Vu Minh Tran, Thuc Huynh, Son Thanh Luu, Doanh C. Bui
similarity 0.62
Abstract

Auxiliary patient data can improve chest X-ray report generation, but directly concatenating heterogeneous clinical information with visual tokens produces long, variable-length decoder prompts and may expose the model to redundant or image-irrelevant context. We propose ICGF-CXRMate, an image-conditioned clinical context compression and gated fusion framework. Learnable queries are first conditioned on the current chest X-ray representations and then attend to the patient-data sequence, compressing it into a fixed number of clinical context tokens. Gated cross-attention selectively integrates these tokens into the visual stream, while the compressed tokens are retained in the decoder prompt as a direct clinical pathway. Experiments on linked MIMIC-CXR and MIMIC-IV-ED examinations show that ICGF-CXRMate improves report quality while reducing the average prompt length. In Stage~2, it improves RadGraph-F1 from 24.00 to 28.86, CXR-BERT similarity from 56.86 to 62.80, and BLEU-4 from 5.14 to 7.96 compared with CXRMate-ED, while reducing the average prompt length from 373.89 to 288.37 tokens, corresponding to a 22.9\% reduction. After self-critical sequence training, ICGF-CXRMate outperforms CXRMate-ED on six of eight report-quality metrics in Stage~3. Ablation studies confirm the complementary contributions of image-conditioned compression, gated fusion, and direct retention of the compressed clinical tokens.

0.17