CS Paper Radar

Alignment of Similarity-Transformed Images Based on Fourier--Mellin Transform Using Auxiliary Function Method

Shinji Yamashita, Yuma Kinoshita, Hitoshi Kiya

eess.IV cs.CV ·submitted 2026-08-12 02:12 UTC · v1
published

Abstract

This paper proposes an algorithm for estimating the similarity transformation, namely translation, scale, and rotation, between two images with subpixel accuracy. Image registration is a fundamental technique for aligning images acquired under different viewpoints and imaging conditions, and a representative approach based on maximizing discrete cross-correlation is the Fourier--Mellin registration. However, the Fourier--Mellin approach often fails to achieve sufficient alignment accuracy when subpixel-level estimation is required. The proposed method integrates (i) scale-and-rotation estimation from the Fourier magnitude spectrum in a log-polar representation and (ii) maximization of phase-only correlation based on the auxiliary function method. This integration enables a two-stage estimation procedure: it first estimates scale and rotation without being affected by translation, and then estimates translation with subpixel precision in the spatial domain using the corrected image pair. A simulation experiment on image pairs subjected to random similarity transformations demonstrates that the proposed method reduces estimation errors in scale, rotation, and translation compared with Fourier--Mellin-based registration methods using discrete cross-correlation.

Comment
Accepted to APSIPA ASC 2026. 6 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Unsupervised Multi-modal Medical Image Registration via Invertible Translation

cs.CV ·2026-11-17 ·Mengjie Guo, Jinming Duan
code/data similarity 0.56
Abstract

In medical imaging, the alignment of multi-modal images plays a critical role in providing comprehensive information for image-guided therapies. Despite its importance, multi-modal image registration poses significant challenges due to the complex and often unknown spatial relationships between different image modalities. To address this, we introduce a novel unsupervised translation-based multi-modal registration method, termed Invertible Neural Network-based Registration (INNReg). INNReg consists of an image-to-image translation network that converts multi-modal images into mono-modal counterparts and a registration network that uses the translated mono-modal images to align the multi-modal images. Specifically, to ensure the preservation of geometric consistency after image translation, we introduce an Invertible Neural Network (INN) that leverages a dynamic depthwise convolution-based local attention mechanism. Additionally, we design a novel barrier loss function based on Normalized Mutual Information to impose constraints on the registration network, which enhances the registration accuracy. The superior performance of INNReg is demonstrated through experiments on two public multi-modal medical image datasets, including MRI T1/T2 and MRI/CT pairs. The code is available at https://github.com/MeggieGuo/INNReg

0.41

Towards Rotation-Only Imaging Geometry: Multi-View Pose Estimation

cs.CV ·2026-11-09 ·Xinrui Li, Qi Cai, Yuanxin Wu
similarity 0.55
Abstract

Global structure-from-motion (SfM) commonly refines relative poses on individual image pairs and then estimates global rotations by rotation averaging. Pairwise refinement does not explicitly combine feature-level constraints with multi-view consistency during rotation initialization. We introduce Global Rotations from Aggregated Matches (GRAM), which estimates global rotations directly from initial relative rotations and inlier matches by minimizing edge-wise rotation-only algebraic residuals. GRAM replaces two-view relative-pose optimization and rotation averaging with a single stage. We further extend rotation- only imaging geometry to multiple views and develop Multi-view Optimization with Rotation-only Reprojection Error (MORE) for nonlinear global rotation refinement. Analytical Rotation-guided Translation (ART) derives locally scaled triplet translations from Linear Global Translation (LiGT) constraints and recovers global translations using weighted least squares. Synthetic and real-world experiments demonstrate the accuracy, robustness, and efficiency of the proposed methods.

0.21

Sub-Pixel Affine Registration of Space Debris Images via the Radon Point Spread Function

cs.CV cs.GR ·2026-09-07 ·Shenshen Luan, Miaomiao Tian, Shuai Jiang, Yan Yang, Shuguo Xie +1 more
similarity 0.52
Abstract

Inter-frame affine misalignment caused by platform jitter and attitude adjustments poses a fundamental challenge for multi-frame analysis of point targets in optical surveillance. Conventional registration methods rely on spatial intensity correlations or distinctive image features, both of which are largely absent in low-signal-to-noise-ratio point target imagery. We introduce the Radon Point Spread Function (RPSF) to characterize point targets in the Radon-transformed domain, and derive a closed-form framework that jointly estimates inter-frame translation and rotation from as few as four scalar RPSF samples per frame pair. The method requires no iterative optimization, feature extraction or interpolation, which is suitable for resource-constrained onboard processing. Simulation results confirm sub-pixel translation accuracy and a mean rotation error of 0.2556° at 1° Radon angular resolution. Validation on five real space debris datasets including both ground-based and in-orbit observations yields a mean calibration error below 0.5 pixels, substantially exceeding the precision required for reliable multi-frame processing.

0.29

Evaluating Transformation Models for pCLE Mosaic Registration

cs.CV ·2026-09-21 ·Ahmed Aboelela, Johannes Barcsay, Jana Friedhof, Miguel Gonçalves, Alexander Hann +1 more
similarity 0.52
Abstract

Confocal Laser Endomicroscopy (CLE) provides real-time, cellular-resolution optical biopsy but has a narrow field of view, which image mosaicing can extend to provide anatomical context. Because of line-by-line acquisition, probe motion, and probe-tissue interaction, frame alignment generally requires a non-linear transformation whose accuracy is difficult to quantify: flexible transformation models can fit intensity features and noise, so appearance-based metrics such as Normalized Cross-Correlation (NCC) can improve without a genuine gain in geometric accuracy. We therefore establish a dataset of 132 frame pairs across fourteen pCLE sequences from 4 patients with manually annotated landmark correspondences, so that Target Registration Error (TRE) can serve as a geometrically grounded complement to NCC. We assess the effect of progressively increasing the transformation model's degrees of freedom, from translation to Thin Plate Spline (TPS), and of six feature-matching backends spanning classical (Shi-Tomasi, Lucas-Kanade) and learned (SuperPoint, SuperGlue, LightGlue, LoFTR, RoMa) approaches. Translation and rigid models prove insufficient under tissue deformation, while TPS with random sampling achieves the strongest landmark-derived alignment of the evaluated configurations; among the learned matchers, used without fine-tuning, only RoMa offers a robust, if modest, advantage over other methods. At the sequence level, pairwise registration quality proved an unreliable predictor of final mosaic quality, so mosaic quality must be evaluated directly rather than inferred from pairwise metrics.

0.34

Modality-Invariant Coarse-to-Fine Retinal Image Registration

eess.IV cs.CV ·2026-08-14 ·Bo Wen, Nehal Nailesh Mehta, Melanie Tran, Dirk-Uwe Bartsch, William Freeman +1 more
published similarity 0.52
Abstract · This paper is a submission to IEEE Transactions on Image Processing (TIP-40498-2026)

Retinal image registration is essential for ophthalmic diagnosis, longitudinal disease monitoring, and multimodal retinal image analysis. Existing retinal registration methods are typically modality-dependent: they are designed or optimized either for a single imaging modality in mono-modal registration or for a fixed pair of modalities in cross-modal registration. This limits their flexibility and applicability in practical scenarios involving diverse retinal imaging modalities and different combinations of them. In this work, we propose a generalizable two-stage, modality-invariant framework for retinal image registration. First, we introduce a sparse feature-matching model driven by a universal retinal vessel segmentation to achieve robust coarse global alignment across modalities. Second, we develop a modality-invariant optical flow estimation network, termed MI-RAFT, to refine the alignment through dense local registration. Extensive experiments demonstrate that the proposed method can handle diverse combinations of commonly used retinal imaging modalities, exhibiting strong modality invariance while outperforming state-of-the-art modality-dependent registration methods.

0.17

ACorD: Adaptive Correspondence Discovery for Medical Image Registration

cs.CV cs.AI ·2026-10-19 ·Arghavan Rezvani, Kun Han, Xiaohui Xie
similarity 0.51
Abstract

Medical image registration is a fundamental task for aligning anatomical structures across images. Exhaustively searching for point-wise correspondences is prohibitively expensive in both computation and memory, particularly for high-resolution 3D medical images. Most recent learning-based methods directly predict correspondences in a coarse-to-fine manner, but often propagate intermediate estimates across scales without explicitly weighting correspondence evidence, which can allow coarse-scale errors to persist during refinement. To address these challenges, we propose ACorD, an adaptive correspondence discovery framework designed to mitigate error propagation with an attention-guided process. ACorD first predicts multiple potential correspondence candidates through Correlation-guided Cross-scale Offset Prediction (CCOP), which combines correlation maps as spatial matching priors with cross-scale features as global deformation context. Then, Multi-Head Deformable Aggregation (MHDA) aggregates these candidate correspondences using attention, producing a learned, non-uniform weighting over competing matches rather than treating them equally. The multi-head design further captures complementary deformation patterns, ensuring both global alignment and local precision. By integrating adaptive offset prediction with selective, attention-based aggregation of correspondence evidence, ACorD enables accurate deformation refinement. Extensive experiments on four public medical registration benchmarks demonstrate that adaptive correspondence discovery within a multi-scale refinement framework improves registration robustness across diverse anatomical structures.

0.24

Scale-Vector Alignment: A Scale-Aware Framework for Spatially Resolved Morphological Similarity in Astronomical Images

cs.CV astro-ph.IMastro-ph.GAphysics.comp-ph ·2026-09-21 ·Mengke Zhao, Guang-Xing Li, Keping Qiu, Shanghuo Li
code/dataunusual similarity 0.51
Abstract · 13 pages, 10 figures. Submitted to ApJS. Comments welcome

Astronomical maps made with different tracers are not expected to have identical morphology. Excitation, optical depth, chemistry, radiation, and ISM phase alter the response of a tracer, and the resulting differences can depend on both position and spatial scale. We propose scale-vector alignment, a scale-aware method based on Constrained Diffusion Decomposition (CDD). CDD decomposes an image into localized scale components; at each position, their amplitudes define a scale vector that describes how the measured intensity is distributed over spatial scale. We define the pixel-wise similarity $\Spix(x,y)$ as the normalized alignment of two local scale vectors. The normalization removes the overall amplitude, so $\Spix$ compares relative scale composition rather than absolute flux. We also define the scale-wise similarity $\Sscale(l)$ by comparing the two CDD component maps at each spatial scale. Spatial shifts are used to construct an empirical shifted reference distribution for $\Spix$. In Orion~A, the tracer with the highest similarity to the dust-derived column-density map changes from $^{12}$CO to $^{13}$CO to C$^{18}$O toward higher column density. In NGC~6334I(N), the line--continuum similarity decreases locally around the brightest compact structures, where radiative-transfer effects can alter the observed line morphology. In NGC~3627, CO is most similar to 21~$μ$m emission, and $\Sscale$ reaches its maximum at an intermediate sub-kpc scale. The method measures where two tracers have similar multiscale structure and at which scales their spatial distributions agree. The implementation is publicly available at https://github.com/meng-ke/Scale-Vector-Alignment.

0.65

BINDER: A Latent Variable Model for Probabilistic Medical Image Registration

cs.CV ·2026-09-17 ·Stefano Cerri, Amirhossein Hassankhani, Yaël Balbastre, Koen Van Leemput
code/data similarity 0.50
Abstract

We propose a new probabilistic model for general-purpose medical image registration that builds upon the mutual information registration criterion. It centers around a spatial interpolation technique that assumes latent voxel-wise correspondences between the images being registered. By exploiting these latent variables, we derive dedicated optimization and MCMC sampling techniques that only involve closed-form iterative updates. When applied to nonlinear registration, an efficient demons-like optimization algorithm is obtained that shows robust out-of-the-box performance across a variety of monomodal and multimodal registration tasks. We also demonstrate a corresponding sampler that can quantify, for the first time, uncertainty in multimodal registration scenarios with very high-dimensional 3D deformations. Our code, which we call BINDER (Bayesian INference for DEformable Registration), is freely available at https://github.com/ste93ste/BINDER.

0.28