CS Paper Radar

Quantifying the Relationship Between Clinical Safety and Environmental Impact in Therapeutic LLMs

Alireza A. Safaei, Laura M. Vowels, Matthew J. Vowels, Apoorv Jha, Shekoufeh Rahimi

cs.CY cs.CL ·submitted 2026-08-12 09:14 UTC · v1
top venue

Abstract

The deployment of large language models (LLMs) in mental health contexts raises questions about the relationship between clinical safety and environmental cost. In this paper, we examine this relationship by combining K-Bench clinical safety scores with EcoLogits life-cycle assessment estimates across 47 supported model configurations. We evaluate model performance and environmental impact across four dimensions: energy use, carbon emissions, water consumption, and abiotic depletion. The results indicate a non-linear trade-off at the upper end of the safety distribution: a 2.61 percentage-point increase in clinical safety score corresponded to an approximately 60-fold increase in estimated energy use per million output tokens. Row-level analyses further suggest that additional test-time compute did not consistently improve clinical safety and, in some configurations, was associated with lower clinical safety scores. These findings suggest that relying solely on larger models or additional inference-time computation may be an inefficient strategy for improving safety in therapeutic AI systems. We discuss the implications for sustainable deployment and highlight dynamic model selection, including model cascading, as a potential approach for reducing environmental impact while preserving clinical performance in higher-risk cases.

Closest papers

Nearest neighbours by meaning across the whole index.

K-Bench: a clinically calibrated benchmark for evaluating large language models in high-risk mental health conversations

cs.CL cs.AIcs.LG ·2026-09-14 ·Laura M. Vowels, Matthew J. Vowels, Shivali Sharma, Apoorv Jha, Rehnuma Choudhury +7 more
benchmark similarity 0.66
Abstract

People increasingly use large language models (LLMs) for mental health support, yet their safety in evolving, high-risk conversations remains poorly characterised. We developed K-Bench, a clinician-calibrated, protected benchmark evaluating 125 model configurations representing 33 base models from 14 providers across a fixed cohort of 200 multi-turn vignettes involving suicide, self-harm, domestic violence, substance misuse, and no-risk presentations. Synthetic patient conversations showed substantial distributional overlap with real human-AI conversations. A frozen GPT-4o judge achieved 94.2% exact agreement with clinician consensus across 6,751 eligible item comparisons from 151 clinician-rated transcripts. Leading models combined strong supportive conversation with combined-risk scores above 95, whereas risk exploration exposed substantial variation among lower-performing configurations. Therapeutic prompting produced configuration-specific gains concentrated among weaker models, while elevated reasoning produced no average improvement. K-Bench combines broader clinical coverage and configuration-scale comparison with a continuously updated public leaderboard whose operational test materials are protected from direct optimisation. The leaderboard is available at www.k-bench.ai.

0.34

GPAgentBench-2K: Benchmarking Large Language Model Agents in Complex Clinical Action Space

cs.CL ·2026-08-31 ·Boqi Chen, Xudong Liu, Yunke Ao, Heejin Do, Jianing Qiu
top venuebenchmark similarity 0.60
Abstract

Large Language Models (LLMs) show great potential as clinical agents, yet existing benchmarks reduce clinical workflows to static predictions or unconstrained Markov Decision Processes (MDPs) with coarse action sets. To address this, we introduce GPAgentBench-2K, the first Constrained MDP (CMDP) LLM-agent benchmark for primary-care clinical decision-making, constructed from expert-validated records of real-world GP encounters. Our environment models a full spectrum of six foundational clinical actions, imposes a topological workflow prior over the action space, and operationalizes safety-informed abstention as a first-class outcome. Evaluating 16 state-of-the-art LLMs reveals a significant performance degradation as the action space scales. Crucially, we uncover a clinical quality-safety gap: even frontier models with the highest diagnosis accuracy violate safety constraints in over half of high-risk cases. Finally, we establish a reference point using Constrained Group Relative Policy Optimization (C-GRPO), and show that while explicitly modeling constraints improves performance over unconstrained RL methods, it remains far from clinically acceptable safety.

0.33

SafeTune: A Unified Faithful Library for Auditing and Repairing Safety Drift in Fine-Tuned LLMs

cs.LG cs.SE ·2026-08-26 ·Pratinav Seth, Saisab Sadhu, Anshul Kaushal, Vinay Kumar Sankarapu
top venue similarity 0.60
Abstract

Methods for addressing safety drift in fine-tuned Large Language Models (LLMs) are scattered across incompatible implementations, lifecycle stages, and evaluation protocols, making them difficult to adopt and compare. We introduce SafeTune, a source-available library that unifies four intervention paradigms: post-hoc weight recovery, safety-constrained fine-tuning, gradient-based unlearning, and inference-time steering, alongside shared interpretability, evaluation, and deployment utilities. SafeTune provides a consistent configuration-driven workflow while preserving the distinct inputs and intervention points each paradigm requires. Its modular registry supports new methods, benchmarks, judges, models, and fine-tuning domains without redesigning the surrounding pipeline. We demonstrate SafeTune through controlled comparisons and finance and medical deployment case studies, showing how it characterizes safety drift, evaluates feasible interventions on common refusal-behavior and capability evaluations, and supports calibrated or layered mitigation.

0.54

Towards Multi-Method Evaluation of AI in Health: Integrating Benchmarks, Autoraters, and Expert Evaluation

cs.CY ·2026-11-03 ·Sarah Montgomery-Taylor, Hamsa Subramaniam, Rob Brisk, Liam Foster, Jack Ching +28 more
similarity 0.59
Abstract · 16 pages, 1 figure, 2 tables

General-purpose generative AI (GenAI) models are being rapidly adopted in healthcare, but they are challenging to assess with traditional evaluation frameworks. These conceptual, methodological, and practical challenges parallel decades of work in evaluating clinician and health system quality and safety. We describe the adaptation of methods from several fields, combined with emerging technical approaches, into a structured, multi-method evaluation framework designed to give well-rounded assessments of GenAI in health at scale. The approach first anchors evaluation to Critical User Journeys (CUJs) to help prioritize out of a large choice space, and maps these to a phased AI system lifecycle (base model development, product development, and post-deployment monitoring), since evaluation at each stage requires different methodological approaches. In this context, the approach then integrates three distinct evaluation methods (closed-question benchmarks, LLM-as-a-judge autoraters, and expert human review) across three core domains: accuracy, safety, and usefulness. Taken together, this approach provides a strategic framework for bridging the gap between benchmarking results and performance in the real world with the goal of supporting decision-making and accountability across development, procurement, and deployment for product teams, health systems, and regulators.

0.14

TrialDesignBench: Benchmarking Language Models for Phase-I Trial Design Against Clinical Knowledge

cs.AI cs.CLstat.AP ·2026-11-09 ·Yihan Hank Tang, Peng Yang, Jiayi Xin, Tianqi Shang, Xuyang Chen +3 more
publishedbenchmarkcode/data similarity 0.57
Abstract · 13 pages, 3 figures, 6 tables. Presented as a poster at the NeurIPS 2026 Workshop on World Models for High-Stakes Health (WMHS). Code and da…

AI is used in much of the clinical trial pipeline. However, selecting the statistical design of a trial, a crucial step that determines how drug doses are tested on humans and evaluated, has seen almost no AI progress. LLMs appear to be a natural fit given their strengths in biomedical knowledge and statistical reasoning. Nevertheless, there is currently no appropriate way to evaluate such abilities because recent regulatory and methodological shifts, most notably FDA's Project Optimus, have redefined what constitutes a reasonable design and rendered many previous designs obsolete. To lay the groundwork for AI-assisted trial design, we introduce TrialDesignBench, a benchmark of 617 Phase-I/I-II oncology dose-finding trials, each paired with an expert-validated reference design that is consistent with the latest FDA regulatory initiatives. This reference standard is produced through a formalization of the expert design process. We evaluate five frontier LLMs, none of which matches the reference standard. Our ablation experiments trace this performance gap to two main causes, inference of latent, unrecorded design determinants from trial sources (supplying them raises class-wise balanced accuracy by 0.22) and structured decision-tree reasoning (+0.24). TrialDesignBench offers a reproducible, contemporary-standard objective for evaluating and enhancing AI-assisted trial design.

0.45

Do AI Agents need Preventive Care? An Epidemiologic Cohort Design for Agentic AI

cs.AI cs.MA ·2026-11-09 ·Shu Jiang, Graham A. Colditz
similarity 0.57
Abstract

As AI agents increasingly perform tasks autonomously across sectors, including healthcare and biomedical research, understanding how their behaviors develop and influence outcomes over time becomes increasingly important. Existing evaluations largely focus on model capabilities and performance on predefined tasks. Here, we propose an epidemiologic cohort design for studying agentic AI, drawing on principles established in human population studies. The framework treats individual agents as members of a cohort, their underlying model as genetic makeup, accumulated work as their time scale, and naturally occurring behaviors as exposures that may influence subsequent outcomes. By following agents longitudinally, this approach enables investigation of behavioral determinants of adverse events, estimation of their potential preventable burden under causal assumptions, and characterization of behavioral changes over an agent's work life. We illustrate the design through two prospective observational cohorts examining curiosity and probing as a safety question, and data checking and analytical accuracy as a reliability question. Together, the framework and illustrative studies provide a generalizable blueprint for designing epidemiologic cohorts of AI agents.

0.26

Neurosymbolic Alignment for Physiologically-Safe Clinical Language Models

cs.AI ·2026-08-25 ·Abdulhady Abas Abdullah, Erik Cambria, Milena Zivkovic
benchmark similarity 0.57
Abstract

Clinical LLMs can generate recommendations that are factually plausible yet physiologically unsafe. We investigate whether safety alignment can be improved by grounding preference optimization in structured physiological knowledge rather than text-only supervision. Methods: We propose Neurosymbolic Alignment, a training-time framework that couples a 7B clinical LLM with an HGNN-based Physiological World Model over an 847K-node biomedical knowledge graph. Candidate responses are scored using homeostatic constraints, multi-hop path plausibility, and drug-interaction penalties, and the resulting rankings drive iterative on-policy ORPO updates. Evaluation is performed on the Clinical Safety Benchmark (CSB), a 2,500-scenario benchmark for physiological constraint violations in generative clinical reasoning. Results: Relative to ORPO, the proposed method improves CSS from 69.5% to 90.8% (+21.3 pp), reduces physician-evaluated HR from 14.1% to 5.1% on the blinded subset, and improves DID from 72.8% to 91.6%. These gains are corroborated by an HGNN-independent Rule-Engine Safety Score (RSS: 86.4%, +21.2 pp over ORPO; r=0.97 concordance with CSS). The method also exceeds GPT-4 (5-shot) on all safety metrics despite a 10x parameter disadvantage, and outperforms an inference-time self-correction pipeline (SFT+SelfCorrect) by 11.4 pp CSS. Under synthetic EHR-style noise, 84.2% CSS is retained. Ablation analysis shows that HGNN scoring (-16.2 pp) and iterative training (-11.5 pp) are the dominant contributors. PhysioScore calibration against 200 clinician labels yielded ECE = 0.038 and kappa = 0.91. Conclusion: Training-time physiological grounding produces measurable and independently verifiable safety improvements in open-weight clinical LLMs under controlled evaluation. External validation on real clinical data is required to determine whether these gains transfer to deployment settings

0.19

The Effect of Quantization on Clinical Benchmarks: Accuracy and Safety Across Model Families

cs.LG cs.CL ·2026-09-02 ·Leonard Twagirayezu, Prasenjit Mitra
similarity 0.57
Abstract

Quantization enables deployment of large language models on resource-constrained clinical edge devices, but its effect on clinical accuracy and safety remains understudied. We evaluate five 7-8B parameter models at FP16, GPTQ-INT8, and GPTQ-INT4 precision across five benchmarks: MedQA, MedMCQA, Med-HALT, a risk-stratified sample of HealthBench, and MedSafetyBench. The study jointly varies quantization bit width, model family, and clinical task type, with explicit risk stratification and safety measures. INT8 GPTQ is universally safe (max. degradation -1.9%-1.9%), while INT4 degradation is substantial and model-dependent: BioMistral-7B, clinically fine-tuned, loses 19.7% on MedMCQA, more than any general-purpose model, showing clinical fine-tuning does not confer compression robustness. MedMCQA degrades more than MedQA under INT4; Med-HALT is largely unaffected. On HealthBench's emergency-risk subgroup, Qwen2.5-7B degrades by 26.8% under INT4, suggesting high-risk scenarios are disproportionately vulnerable to compression. On MedSafetyBench, the model family dominates over precision (refusal rates range 10.2%-74.9% at FP16), though Qwen2.5-7B (-17.8%) and Meditron-7B (-28.3%) show substantial INT4 safety degradation; notably, Qwen2.5-7B is simultaneously the most accuracy-robust model, demonstrating that accuracy and safety robustness are independent properties. We additionally test two recovery methods, clinical calibration substitution and QLoRA fine-tuning, both producing the same trade-off: MedMCQA recovers while MedQA further degrades, indicating recovery strategies require task-specific validation rather than being assumed universally beneficial. These findings indicate INT8 is broadly safe for clinical deployment, while INT4 safety must be assessed per-model and per-task, and that safety alignment is determined primarily by instruction tuning rather than clinical domain adaptation.

0.30