CS Paper Radar

CoMedBench: A Multi-Source Benchmark of Synthetic Medical Data Fidelity and Downstream Utility

Akanta Das, Farhad Al-Amin Dipto, Mrinmoy Sarkar Anto, David Rehkopf, Ayin Vala, Tanmoy Sarkar Pias

cs.LG ·submitted 2026-08-13 04:24 UTC · v2
benchmark

Abstract

Access to clinical data is essential for developing reliable healthcare machine learning systems, but direct use of electronic health records is constrained by privacy regulation, institutional review, data-use agreements, and the risk of re-identification. Synthetic data promises a practical alternative: it can preserve useful statistical and clinical structure while reducing exposure of sensitive patient records. Prior studies often evaluate a single generator, one dataset, or a narrow downstream task, making it difficult to know when synthetic data can support model development and when it fails to preserve task-critical signal. We introduce CoMedBench, a reproducible benchmark that evaluates a family of generators under a common clinical-validity framework and one shared training and evaluation engine, spanning static tabular and temporal downstream tasks on established critical-care datasets. In total the benchmark spans 37 dataset-task pairs across two modalities consists of 20 static tabular and 17 temporal ICU time-series-drawn from seven public data sources: three intensive-care databases (MIMIC-III, MIMIC-IV, and eICU) together with the UCI Machine Learning Repository, the CDC BRFSS diabetes cohort (2015), NHANES (1999-2014), and the pycox survival datasets (GBSG and METABRIC). The benchmark evaluates both statistical fidelity and task utility by comparing models trained and tested across real and synthetic data. In these settings, synthetic training data preserves most of the downstream signal: on tabular tasks the reference generator CoMed-CTGAN retains a mean AUROC utility (the synthetic-to-real performance ratio) of 90.6%, rising to 97.3% for the strongest generator, CoMed-TVAE. Temporal ICU tasks are harder and more generator-sensitive: CoMed-CTGAN retains 81.6% (AUROC) and only 64.0% under the imbalance-sensitive AUPRC, whereas CoMed-TVAE still retains ~95% (AUROC).

Closest papers

Nearest neighbours by meaning across the whole index.

OmniSynth: A Meta-Evaluation Framework for Benchmarking the Quality of Missingness-Inclusive Synthetic Health Data

cs.DB ·2026-11-09 ·Annabel Zhu, Océane Doremus, Ariel Guerra-Adames, Marta Avalos-Fernandez, Emmanuel Lagarde +2 more
similarity 0.74
Abstract · Accepted to the BIBM'26 ARRL-Health'26 Workshop

Synthetic data are an emerging solution to the reproducibility crisis in machine learning for health, driven by data privacy restrictions surrounding electronic health records. Yet no consensus exists on how to evaluate synthetic health data quality, existing metrics functionally overlook missingness despite its prevalence in clinical data, and benchmarking frameworks have never been empirically validated. We introduce OmniSynth, a modular Python benchmarking suite that evaluates synthetic tabular data across fidelity, missingness similarity, utility, and privacy - the first framework to explicitly evaluate missingness as a distinct dimension of synthetic data fidelity. OmniSynth further proposes a meta-evaluation procedure that stress-tests evaluation performance under controlled degradation scenarios, providing a systematic characterization of how an evaluation framework behaves across datasets, sample sizes, and variable types. Applying this procedure to OmniSynth in two health datasets (Pima Indians Diabetes; MIMIC-IV-ED), we found that scores responded monotonically to degradation, three of four novel missingness metrics captured induced missing data patterns, and individual metric contributions to the scoring system were empirically justified.

0.22

Explainable Transformer Models for Clinical Prediction Tasks on Structured Electronic Health Records

cs.LG ·2026-08-20 ·Jun Ni Du, Lukas Adamek, Maxim Kryukov, Flavio Dormont, Ziv Bar-Joseph +2 more
top venuebenchmark similarity 0.73
Abstract · Accepted at MLHC 2026; to appear in Proceedings of Machine Learning Research (PMLR)

Predictive models over structured electronic health records (EHRs) remain central to machine learning for healthcare, but few have jointly emphasized quantitative laboratory information and interpretability with respect to input medical events. We present BERT-LER, a BERT-style model for coded EHR timelines pretrained and fine-tuned from a de-identified EHR dataset of 75 million patients, that encodes laboratory test results as discrete tokens while retaining graded information through percentile-based binning, paired with Integrated Gradients for token-level attributions grounded in the input EHR sequence. We benchmark our approach on the public EHRShot benchmark suite and on an asthma severity progression study based on real-world data. This addresses a methodological gap in EHR foundation-style modeling by unifying laboratory value representation and explainability in a single framework, while assessing whether both predictive performance and explanations generalize beyond standard clinical prediction tasks. Across EHRShot and asthma tasks, BERT-LER achieves predictive performance that is competitive with, and on laboratory-related tasks often exceeds, publicly available benchmark models, and provides attributions that align with clinically known risk factors. Our architecture and explainability approach can be applied to many therapeutic areas and prediction tasks using language models trained on structured EHRs.

0.42

TabBioMed: A Large-Scale Benchmark for Biomedical Tabular Learning

cs.LG ·2026-11-18 ·Pau Mateo-Bernadó, Saivenkata Nagavyjayanthi Polapragada, David Bonet, Pol Arbiol Rakuljic, Laia Mogas Pladevall +6 more
publishedbenchmarkcode/data similarity 0.72
Abstract · 87 pages, 43 figures, including appendices and the NeurIPS paper checklist

Recent advances in machine learning have accelerated biomedical prediction, but evaluation on structured biomedical data remains fragmented, especially for datasets with high dimensionality, large sample size, missingness, and class imbalance. We introduce TabBioMed, a large-scale benchmark of 94 curated public biomedical tabular datasets spanning electronic health records, drug discovery, genomics, transcriptomics, proteomics, metabolomics, single-cell omics, and systems biology. TabBioMed unifies these datasets through a standardized, dataset-aware preprocessing and evaluation framework, enabling reproducible comparison across classification, regression, and multi-target tasks. We benchmark 23 models across classical baselines, gradient-boosted trees, neural tabular architectures, and tabular foundation models. Foundation models deliver the strongest family-level predictive performance. However, their gains are regime-dependent: tree-based models and tuned multilayer perceptrons remain highly competitive, often dominating under inference-time or training-cost constraints. Overall, TabBioMed shows that biomedical tabular learning is strongly context-dependent, with optimal model choice depending on data regime, task type, and computational budget. We release TabBioMed with curated datasets and splits, preprocessing code, baselines, and results, providing a reproducible benchmark for practical model selection and future methods development in biomedical machine learning, available at https://github.com/AI-sandbox/TabBioMed.

0.44

Hidden Data Challenges in Clinical Machine Learning

cs.LG ·2026-10-09 ·Carolin Cissée, Dennis Fast, Raneen Younis, Alexander Löser, Wolfgang Nejdl +1 more
code/data similarity 0.72
Abstract

Widely reused preprocessing pipelines for electronic health records can encode assumptions about when information became available, what clinical episode a label represents, and what missingness means. These assumptions are rarely audited systematically and may propagate across subsequent studies when preprocessing pipelines are reused or adapted. Using MIMIC-IV as a case study, we identify and quantify violations of three complementary forms of preprocessing alignment, i.e., temporal, semantic, and population alignment, which manifest as temporal leakage, feature-task misalignment, and biased imputation. We show how ambiguities in timestamp semantics, episode definitions, endpoint construction, modality selection, and missingness handling can alter the information available to a model and affect the interpretation of its predictions. Through analyses of MIMIC-IV data and empirical case studies, we demonstrate that such choices may remain largely invisible in aggregate predictive performance while changing the signals on which models rely. We derive practical recommendations for temporally valid, clinically aligned, and reproducible preprocessing of MIMIC-IV and related electronic health record datasets. The code for our experiments, including our proposed preprocessing, is available at: https://github.com/m2l-lab/mimic-iv-preprocess.

0.22

Future Querying: Can LLMs Serve as Implicit Medical World Models?

cs.CL cs.AI ·2026-08-24 ·Siri Willems, James Butterworth, Lore Goetschalckx, Peter Vrancx, Philippe Modard +2 more
published similarity 0.70
Abstract · This paper is accepted at The 1st MICCAI Workshop on Medical World Models (MICCAI-2026)

Traditional clinical prediction models rely on task-specific pipelines and curated, structured data, which scale poorly and underutilize unstructured text. To address this, we introduce future querying, a paradigm that probes whether large language models (LLMs) can function as implicit medical world models by evaluating their ability to answer time-indexed clinical queries about a patient's future. Our framework operates on unstructured clinical documentation using endpoint-agnostic training, enabling a single model to answer diverse clinical queries over patient trajectories without manual feature engineering or task-specific retraining. We show that small, locally fine-tuned open-weight models can match or approach larger proprietary systems, making the framework suitable for privacy-preserving, on-premise deployment. Evaluated on a new synthetic medical reports dataset and real ICU notes from the MIMIC-IV dataset, our results provide encouraging evidence that LLMs can capture aspects of clinical dynamics.

0.30

Rethinking How We Evaluate Methodological Progress in Health AI

cs.LG cs.AI ·2026-09-16 ·Florent Pollet, Matthew McDermott
similarity 0.70
Abstract

Methodological progress in artificial intelligence (AI) for electronic health records (EHRs) depends on our ability to determine which algorithms work better, and under which conditions. However, such progress is thought to be hindered by difficulties in reproducibility and in defining clinically meaningful evaluation tasks. We empirically study these barriers by re-implementing 12 historical and recent algorithms within a shared evaluation framework and evaluating them on two clinical datasets, MIMIC-IV and NWICU. We compare two complementary task families: expert-authored clinically meaningful tasks and generated tasks defined from randomly sampled event codes and prediction horizons. We ask whether relative algorithms comparisons transfer across task families and datasets, whether residual task heterogeneity contains useful methodological structure, and what a controlled comparison reveals about progress over the last decade. We find that aggregate pairwise comparisons transfer strongly across evaluation settings, including from randomly generated tasks to clinically meaningful tasks and across datasets. At the same time, clinically meaningful tasks exhibit greater task-method interaction, providing preliminary evidence that task properties can help explain when particular modeling choices are advantageous. Finally, newer algorithms do not consistently outperform earlier approaches: gradient-boosted trees remain highly competitive when paired with a modern, wide and sparse representation of the EHR. Together, these results suggest that useful methodological knowledge may require less task engineering than commonly assumed, while highlighting the importance of understanding the structured heterogeneity that remains across tasks and methods.

0.42

Temporal Island Sparse Autoencoders for Interpreting Clinical Time-Series Models

cs.LG ·2026-11-02 ·Muhan Yeo, Bong Gyun Kang, HyunGi Kim, Sungroh Yoon
top venue similarity 0.70
Abstract · Accepted at NeurIPS 2026

Deep learning models for electronic health records achieve strong predictive performance but provide little insight into what clinical concepts they represent internally. Post-hoc attribution methods produce per-cell importance scores that lack temporal coherence, cross-variable structure, and reusability across patients. We introduce the Temporal Island Sparse Autoencoder (TI-SAE), which learns a backbone-specific, patient-shared clinical concept dictionary from a frozen predictive model's representations. Each dictionary entry (latent) is defined by learned temporal Gaussian islands (specifying when the concept is active) and a sparse variable-composition vector (specifying which variables are involved). A decoupled selector then identifies which dictionary entries drive each patient's prediction, separating representation learning from attribution. We evaluate TI-SAE across five backbone architectures spanning different representation strategies on MIMIC-III and MIMIC-IV (three prediction tasks each). TI-SAE produces structured clinical concepts that go beyond transient attribution heatmaps while achieving strong performance on standard faithfulness benchmarks.

0.31

Sequence Composition in EHR Foundation Model Pretraining

cs.LG ·2026-10-12 ·Joshua Placidi, Inigo Stibbe, Alfred J. Balston, Marek Rei, A. Aldo Faisal
position similarity 0.68
Abstract · 26 pages, 11 figures, 10 tables

Autoregressive electronic health record (EHR) foundation models predict the next event token in patient trajectories: sequences of structured medical events. A typical pretraining strategy is to concatenate all trajectories into a global stream and sample token windows from it. This gives patients with longer sequences more training exposure and allows tokens to attend across patient boundaries. We argue that these choices create a misalignment between pretraining and downstream clinical tasks. To explore this, we investigate how the composition of pretraining sequences affects clinical prediction performance. Using the global-stream approach as a baseline, we propose alternative sequence composition methods that control how patient trajectories contribute to pretraining sequences. Across four MIMIC-IV v2.2 tasks, our best method improves macro AUROC, AUPRC, F1, and balanced accuracy, with relative gains of 9.3% in F1 and 2.7% in AUPRC under a fixed training recipe. We find that these gains generalize across four additional evaluation settings, including the INSPIRE and eICU-CRD datasets, with improvements in macro AUROC, AUPRC, and F1 score. Our results show that simply changing how EHR data are presented to the model during pretraining can improve downstream performance, without changing the model or collecting additional data.

0.18