CS Paper Radar

GSToken: Geometry-Structured Gaussian Tokens for Compact 3D Medical Image Representation

Xiaoduo Li, Quan Gu

cs.CV ·submitted 2026-08-18 06:44 UTC · v1

Abstract

Effective segmentation of multi-modal MRI is central to improving neural network accuracy in brain tumor recognition. Existing methods typically compress 3D volumes into token sequences via fixed patch encoding or learned attention pooling (e.g., TokenLearner). However, these compression schemes discard explicit spatial shape information; the resulting tokens convey no notion of lesion morphology or spatial extent. Meanwhile, end-to-end evaluation entangles a tokenizer's information retention with the reconstruction capacity of the downstream decoder, and the lack of a unified capacity contract across methods makes performance differences difficult to attribute. In this paper, we introduce Gaussian tokens to multi-modal brain tumor segmentation for the first time: each token carries not only a semantic feature but also a learned 3D center, anisotropic scale, and orientation, endowing the representation with explicit geometric support at negligible parameter cost. We further propose a frozen-token utility evaluation protocol: the trained tokenizer is frozen, its output is cast into a fixed-capacity serialized contract, and a shared lightweight Transformer probe independently measures each tokenizer's retained information under strictly matched conditions. Multi-seed paired statistical testing shows that GSToken consistently and substantially outperforms capacity-matched adaptive baselines under frozen probing, with uniform advantages across all tumor sub-regions, surface, and distance metrics. These results demonstrate that explicitly encoding spatial geometry within tokens significantly improves the information density of volumetric representations, offering a new design principle for compact 3D medical image representation and downstream reading.

Closest papers

Nearest neighbours by meaning across the whole index.

MedVTok: A General-Purpose Medical Visual Tokenizer

eess.IV cs.CV ·2026-10-26 ·Chenglong Ma, Yuanfeng Ji, Junzhi Ning, Jiyao Liu, Yujie Wei +16 more
published similarity 0.70
Abstract · NeurIPS 2026

Multimodal medical AI requires a common visual interface for encoding heterogeneous imaging evidence for patient condition modeling. However, existing medical visual tokenizers are often tied to a specific dimension and imaging modality, forcing multimodal systems to rely on fragmented and poorly reusable representations. We introduce MedVTok, a general-purpose visual tokenizer that maps 2D images and 3D volumes from diverse imaging modalities into a unified token space. Building such a tokenizer poses two key challenges: preserving anatomical structure across dimensions and capturing clinical semantics across modalities. To this end, MedVTok introduces (i) slice differential regularization, which explicitly models inter-slice anatomical coherence missing in previous per-pixel/per-voxel supervision, and (ii) multi-expert representation alignment, which integrates knowledge from multiple medical expert encoders while retaining modality-specific complementary knowledge. Trained on 28M images and 70K volumes across 9 imaging modalities, MedVTok supports classification, retrieval, segmentation, synthesis, visual question answering, and medical report generation through a single tokenizer. Across 24 benchmarks, MedVTok achieves state-of-the-art performance, demonstrating a scalable token interface that unifies medical image dimension, modality, and task usage.

0.19

Parameter-Efficient Multimodal Brain Tumor Segmentation With Stage-Wise Shared Adapters

cs.CV ·2026-10-13 ·Milad Rostamian, Mohammadreza Mohammadi, Ender Konukoglu, Mohsen Soryani
similarity 0.69
Abstract

Different MRI modalities reveal different parts of a brain tumor. Segmentation models combine information from these modalities to outline tumor regions. Many models use a separate encoder for each modality. However, exchanging features among these encoders at several stages can increase model complexity. We introduce the Block-Wise Shared Adapter (BWSA), which combines compressed features from the modality encoders in a shared path and returns adapted features to each stream. In its fixed-blending form, BWSA adds the adapted features to the original features. Its trainable-gated variant (TG-BWSA) instead learns separate weights for the original and adapted features at each modality and encoder stage. We evaluate both variants on BraTS 2020 and BraTS 2023 with four segmentation backbones. On the official BraTS 2023 online validation set, BWSA increases average region-wise Dice by 1.3--7.6 percentage points relative to the corresponding unmodified backbones. TG-BWSA increases it by 2.8--7.7 points. Both variants add approximately 0.85--3.73% parameters and reduce average HD95 relative to the unmodified backbones.

0.34

Beyond Representation Learning: A Systematic Study of Joint-Embedding Predictive Generation for 3D Brain MRI

cs.CV ·2026-08-28 ·Meng Zhou, Wenhao You, Yuxing Chen, Yueying Tian
similarity 0.68
Abstract · Preprint, code will be released after review

Joint-embedding predictive architectures (JEPAs) have primarily been developed for self-supervised representation learning. Denoising JEPA (D-JEPA) recently demonstrated strong generative capabilities on natural images, yet the applicability to 3D medical imaging remains unexplored. Building on the D-JEPA framework, we present Med-D-JEPA, a systematic adaptation and evaluation of joint-embedding predictive generation for 3D brain MRI. Med-D-JEPA operates on continuous latent tokens produced by a 3D KL-regularized adversarial variational autoencoder, and combines masked context prediction, representation-level alignment, per-token diffusion, and iterative next-set-of-token sampling. We evaluate unconditional and class-conditional generation quality on BraTS2019 and OASIS-1 datasets; downstream classification utility; and preliminary whole-tumor segmentation on BraTS2020. Across different generation settings, Med-D-JEPA achieves superior or competitive performance compared to several strong baselines on fidelity and diversity metrics. Compared to training with real samples, Med-D-JEPA-based synthetic pretraining improves classification AUC from 0.63 to 0.85 on BraTS2019 and from 0.78 to 0.87 on OASIS-1. In the segmentation study, pretraining on Med-D-JEPA samples improves Dice from 0.74 to 0.80 and reduces HD95 from 13.40 to 9.56 mm. These findings establish joint-embedding predictive generation as a promising direction for 3D medical image synthesis and encourage further research in this direction.

0.47

TRIUNE-Net: Harmonizing Scale, Shape, and Efficiency in Pancreatic Tumor Segmentation

cs.CV ·2026-09-08 ·Amir Hossein Saleknia, Alireza Kheyrkhah, Sanaz Karimijafarbigloo, Reza Azad, Sina Houshmand +3 more
code/data similarity 0.67
Abstract

Pancreatic tumor segmentation in 3D CT volumes is challenged by extreme scale variability across both the pancreas and tumor, and highly irregular tumor morphology. While recent advances have pushed segmentation performance, existing methods do not explicitly address these challenges and come at the cost of excessive computational complexity, limiting their practicality in resource-constrained clinical environments. We propose TRIUNE-Net, a lightweight unified architecture that harmonizes scale, shape, and efficiency through three synergistic innovations. A multi-scale context aggregation module with stage-adaptive dilated convolutions enables the model to reason across the broad range of anatomical scales present in both organs. A serial linear-deformable attention mechanism combines large effective receptive fields with shapeadaptive deformable convolutions to capture irregular, non-convex tumor morphologies. Finally, an information-preserving downsampling module replaces conventional max pooling entirely, retaining all spatial information while adding negligible parameters, preventing small tumors from being discarded before they can be recognized. On both the MSD Pancreas and NVD Pancreas datasets, TRIUNE-Net achieves state-of-theart results with only 5.86 M parameters and no external pre-training, outperforming all baselines across all key tumor metrics. Specifically, it surpasses the next-best model by 0.45% in tumor Dice, 6.0 points in F1 score, 6.6 points in sensitivity, and 3.4 points in precision, simultaneously reflecting its ability to suppress both missed tumors and false alarms in clinically realistic conditions. Our code is available at: https://github.com/abdora-ai/TRIUNE-Net

0.30

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.66
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

Lightweight Vision Transformer-Based U-Net for Brain Tumor Segmentation from MRI

cs.CV ·2026-09-24 ·Sheekar Banerjee, Md. Srabon Chowdhury, Md. Mahbub Hasan Akash, Ishtiak Al Mamoon
published similarity 0.66
Abstract · Accepted at The 2026 IEEE International Conference on Biomedical Engineering, Computer and Information Technology for Health (BECITHCON)

Accurate brain tumor segmentation from Magnetic Resonance Imaging is essential for diagnosis, treatment planning, and surgical guidance. Although Convolutional Neural Networks, particularly UNet, have achieved significant success in medical image segmentation, they often struggle to capture the long-range spatial dependencies required to model tumors with irregular shapes and complex boundaries. This paper proposes a lightweight Vision Transformer UNet that combines the hierarchical feature extraction capability of UNet with the global context modeling of Vision Transformers. The proposed architecture incorporates a compact ViT bottleneck within a U-Net encoder-decoder framework, enabling effective learning of both local and global features while maintaining computational efficiency with only 2.6 million trainable parameters. The model was evaluated on the TCGA LGG MRI Segmentation dataset, achieving a mean Intersection over Union of 0.8100 and a Dice score of 0.8446, outperforming the baseline UNet by 3.75% and 3.15%, respectively. Extensive quantitative and qualitative analyses, including confusion matrix evaluation, precision recall curves, per-image performance distribution, and tumor size dependency analysis, demonstrate the effectiveness and robustness of the proposed method for brain tumor segmentation.

0.14

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

cs.CV ·2026-10-17 ·Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus +6 more
similarity 0.66
Abstract · 26 pages, 6 figures, 15 tables (including appendix)

Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorten acquisitions by sacrificing spatial resolution, particularly along the slice axis. Super-resolution can recover higher-resolution images, but existing methods are typically specialised to one scale or acquisition geometry, limiting their use across heterogeneous clinical protocols. We present GSMR3D, a continuous volumetric model that reconstructs arbitrary isotropic and anisotropic resolutions with a single checkpoint per MRI contrast. It combines a learned dictionary of anisotropic 3D Gaussian prototypes with scale-conditioned frequency encoding and an exact measurement-consistency projection, keeping reconstructions consistent with the acquired low-resolution data. We train separate models on 3,731 contrast-enhanced T1-weighted and 30,254 T1-weighted brain MRI volumes from clinical and population-based cohorts. We evaluate GSMR3D against geometry-specific specialists for isotropic, in-plane, and through-plane super-resolution using reconstruction quality and downstream tasks: brain tumour segmentation, brain-metastasis detection, and brain parcellation. GSMR3D outperforms specialists at isotropic $2\times$ and achieves better LPIPS, DISTS, and FID across all geometries, although specialists retain higher PSNR in anisotropic settings. It more faithfully preserves glioma segmentations across all geometries, achieves the highest lesion sensitivity on an independent brain-metastasis cohort, and the highest brain-parcellation agreement for isotropic and in-plane reconstruction. Reconstruction takes about 6s per volume, adding little overhead relative to acquisition-time savings. GSMR3D offers a flexible approach to MRI scan-time reduction with one model per contrast across geometries while preserving information relevant to downstream tasks.

0.17

MicroBT: Centroid-Guided Synergistic Learning for Multi-Modal Micro Brain Tumor Segmentation and Counting

cs.CV cs.AI ·2026-11-10 ·Zhenye Lou, Qing Xu, Stefanie Thust, Dorothee P. Auer, Zhen Chen +1 more
publishedcode/data similarity 0.65
Abstract · Accepted at the 37th British Machine Vision Conference (BMVC), 2026

Multi-modal brain tumor segmentation is essential for clinical diagnosis, radiotherapy planning, and longitudinal monitoring. While recent studies have achieved remarkable overall segmentation performance, they rely on overlap-based objectives that inherently favor large regions, causing sub-3 mm micro-lesions to be systematically suppressed during training. Moreover, existing pixel-level segmentation frameworks lack explicit instance-level modeling, leading to unreliable lesion counting that directly impacts clinical staging and therapeutic decisions. To address these challenges, we propose MicroBT, a unified multi-modal framework for micro brain tumor segmentation and counting. Our core insight is that a fundamental geometric property is inherently scale-invariant: regardless of size, each lesion possesses a well-defined centroid. Leveraging this, we first devise a centroid-anchored synergistic paradigm that utilizes predicted centroids as shared anchors to simultaneously condition dense segmentation and instance-level localization. To counteract the tumor size imbalance, we further devise a Volume-Calibrated Loss (VC-Loss) that adaptively amplifies the gradient contribution of micro-lesions, alongside a Size-Aware Curriculum Optimization (SACO) that stabilizes multi-task training by establishing global representations before progressively unlocking fine-grained localization. Extensive experiments demonstrate that MicroBT outperforms state-of-the-art methods, particularly on metastases, where micro-lesion ($\leq 3$ mm) localization precision improves by approximately 7% and counting estimation errors decrease by approximately 26%. The code is available at https://github.com/leonlou921/MicroBT.

0.49