CS Paper Radar

A Few Cases Are All You Need: An Empirical Study of Annotation-Efficient LoRA Fine-Tuning of MedSAM3

Sachin Dudda Nagaraju, Bendik Skarre Abrahamsen, Ashkan Moradi, Mattijs Elschot

cs.CV cs.AI ·submitted 2026-08-19 09:34 UTC · v1

Abstract

Medical image segmentation is essential for clinical workflows such as treatment planning and disease assessment. While specialist tools like TotalSegmentator and MRSegmentator achieve strong performance, they require large annotated datasets for training. Medical foundation models offer a promising alternative through large-scale pretraining that reduces the annotation burden for new tasks, but zero-shot performance remains limited. Parameter-efficient adaptation via Low-Rank Adaptation (LoRA) enables efficient specialization with few trainable parameters, but a key question remains: how many expert-annotated cases are needed to achieve clinically useful segmentation performance? We address this by adapting MedSAM3 with LoRA for five abdominal organs (liver, kidneys, spleen, gallbladder, and pancreas) in CT and MRI using only 1, 2, 5, and 10 annotated cases, evaluating on AMOS22 dataset. With just 10 cases, models achieve performance competitive with specialist systems trained on orders of magnitude more data. Notably, this includes reliable gallbladder segmentation (Dice 0.68 CT, 0.59 MRI) where existing tools fail almost completely (Dice 0.0004), while remaining within 5--10% of MRSegmentator for liver, kidneys, and spleen using over 100 times fewer annotations. Furthermore, external validation on the Whole Heart Segmentation dataset shows that the approach extends to cardiac segmentation, a use case beyond the scope of TotalSegmentator (MRI) and MRSegmentator, achieving competitive left ventricle (LV) performance with only 10 annotated cases. Training requires only3--5,hours per organ on a single GPU, approximately 2--3 times faster than nnU-Net. These findings suggest that ten annotated cases are sufficient for clinically useful segmentation, effectively reducing bottlenecks for both image annotation and training time.

Closest papers

Nearest neighbours by meaning across the whole index.

MedAdaptAgent: An Automatic Harness for Adapting Medical Imaging Models to New Sites

cs.CV ·2026-10-26 ·Hanxue Gu, Zhonghao Liu, Xingrui Gu, Kang Wang, Yang Yang
code/data similarity 0.73
Abstract · 17 pages, 2 figures. Code: https://github.com/Guhanxue/medagent

Reusing pretrained medical-imaging models offers an alternative to training from scratch. A model trained for the same task may perform poorly at a new hospital because imaging protocols and preprocessing differ. Effective adaptation depends on the model architecture, domain shift, and available labels and compute. Adaptation can improve scores on a small labeled set yet reduce performance on unseen data. We present MedAdaptAgent, an automatic harness that turns a supplied model, target data, and a free-text request into a new-site adaptation workflow. Its LLM-driven Adaptation Planner uses model-site evidence to choose compatible experiments and revise subsequent adjustments. The harness requires evidence of improvement over the pretrained model, then delivers the selected model as a complete, runnable package. Evaluation spans 26 segmentation and classification transfers across architectures and compute settings, with segmentation annotation budgets ranging from zero-shot transfer to few-shot adaptation. With 20 local annotations, mean segmentation Dice rises from 0.483 to 0.774 across 10 transfers, a 60.1% relative gain, with no harmful replacements. Mean classification AUROC rises from 0.810 to 0.837 across 13 transfers, a 3.4% relative gain. Comparing adapted models with the pretrained model reduces harmful classification replacements by 30.8% versus selecting the highest-scoring model on the available labels, using identical candidates. Seven public-model deployments demonstrate adaptation and reproducible package delivery across contrast and modality shifts. A CT-to-MRI study extends the evaluation to four LLM planners, including two open-weight models. We release the code on GitHub.

0.36

Foundation Model-Enabled Efficient Data Sampling (FEEDS): A label-efficient training strategy for pan-cancer, multi-tracer PET/CT datasets

cs.CV ·2026-08-11 ·Biratal Raj Wagle, Bashirul Azam Biswas, Grant Chau, Matthew E. Maeder, Muhammad Azeem Arshad +3 more
code/data similarity 0.71
Abstract · Code is publicly available on https://github.com/Image-and-Multimodal-Data-Analytics/FEEDS

Automated lesion segmentation in whole-body PET/CT imaging can assist clinicians with cancer detection, staging, and treatment planning across radiotracers and cancer types. However, training lesion segmentation models that capture variations in lesion size, distribution, and appearance requires large annotated datasets, whose creation is both time- and expertise-intensive. As a result, models trained on limited labeled PET/CT data often lack the accuracy and generalizability needed for clinical use. We present FEEDS (Foundation model-Enabled Efficient Data Sampling), a label- and compute-efficient learning strategy that uses vision foundation model embeddings to select the most informative and diverse unlabeled cases for expert annotation. Unlike unsupervised, semi-supervised, and active learning approaches, FEEDS is a one-step training paradigm requiring only a limited, representative training set, making it label- and compute-efficient. We train and validate FEEDS using the AutoPET-III dataset. We test its accuracy and generalizability on three held-out sets: AutoPET-III, DeepPSMA, and an internal Dartmouth-Hitchcock Medical Center dataset. We evaluate clinical utility at the voxel, lesion, and anatomic region level to assess performance in high-risk areas and treatment planning utility. FEEDS outperforms random-sampling-based labeling, pseudolabel-based semi-supervised learning, and training with limited labeled data alone. It generalizes across all three test sets, FDG and PSMA tracers, and multiple diseases, matching fully-labeled (100\%) training performance with 70\% less annotation burden. FEEDS addresses the challenge of label scarcity in an automatic lesion segmentation framework by providing a practical approach for constructing representative and diverse annotation queues from large, unannotated clinical repositories.

0.59

Weakly-supervised Kidney Tumor Classification from CT Scans with Multi-Instance Learning and Anatomical Filtering

cs.CV ·2026-09-07 ·Joonas Ariva, Dmytro Fishman
similarity 0.69
Abstract · 16 pages, 3 figures

Deep learning models for CT scan analysis are often limited by the scarcity of precise pixel-level annotations, which require significant radiologist effort to produce. Training on scan-level labels alone reduces annotation requirements but introduces challenges: low supervision ratios and large input volumes make models prone to overfitting and shortcut learning. In this work, we investigate two complementary methods to address these challenges: multi-instance learning (MIL) and anatomical filtering. MIL divides CT volumes into 2D slice instances, enabling efficient 2D architectures with ImageNet pretraining rather than computationally demanding 3D models. Anatomical filtering uses Compass, our self-supervised body part regression model, to crop scans to pathology-relevant subregions without requiring segmentation masks. We evaluate two MIL frameworks - Attention-based MIL (ABMIL) and FocusMIL - on kidney tumor classification across one internal dataset (TUH) and two external datasets (KiTS23 and TCGA-KiRC). Our best models achieve F1 = 0.83 on the internal test set using only scan-level labels. We further show that anatomical filtering with the Compass model is critical for the out-of-distribution generalization of embedding-based ABMIL, while instance-based FocusMIL demonstrates greater inherent robustness to distribution shift. While evaluated on kidney tumors, we consider this a proof-of-concept for a broader weakly supervised CT classification pipeline applicable to other organs and pathologies.

0.16

MedImgAnnotator: batch wise medical image annotation and preprocessing tool

cs.CV eess.IV ·2026-11-17 ·Ewunate Assaye Kassaw, Amit Mehndiratta, Peush Sahni, Anup Singh
code/data similarity 0.69
Abstract

The curation of large cohort datasets for developing deep learning models demands annotating or editing over the AI-predicted labels. However, openly available annotation tools are time-consuming, as they involve complex navigational steps and do not support batch processing. This study aimed to develop a simple, fast, semiautomated batch-annotation tool named MedImgAnnotator. The tool was created by integrating editing tools, image mask pair matching logic, preprocessing functions, object detection tool, and a plugin management system. Its performance was evaluated in terms of active annotation time and ease of use by the developer and 12 users using open-source MR and CT scans. Additionally, the tool had been used by the MICCAI 2026 CARE Challenge liver segmentation best performance winner to annotate liver masks from 6412 MRI volumes. The evaluation results showed that MedImgAnnotator reduced active annotation time from 206.5+/-32.87 (average active annotation time of openly available tools) seconds to 59 seconds. The Wilcoxon signed-rank test of 12 users evaluation results recorded P values of 0.032 and 0.008 for the active annotation time and higher ease of use rating metrics, respectively, indicating that the current tool significantly reduces annotation time and enhances ease of use. Moreover, the tool utilization for annotating different regions of interest from different modality scans and body regions shows its usability across modalities and areas of interest. MedImgAnnotator, which significantly reduces active annotation time for large imaging cohorts, is available as an executable file and as a Python script. Access link: https://ewunateassaye.github.io/developed-tools/medimgannotator.html

0.30

Segment Anything Pancreas: A Unified MRI Segmentation Model for Pancreatic Cancer Radiotherapy

cs.CV ·2026-10-29 ·Zach Eidex, Mojtaba Safari, Kundan Thind, Parag J. Parikh, Zhen Tian +1 more
similarity 0.69
Abstract

Background: Limited tumor annotations and incomplete labels across MRI datasets hinder unified segmentation of pancreatic tumors and organs at risk (OARs) for MRI-guided radiotherapy. Purpose: We propose Pancreas-MedNeXt, a unified model that segments the whole pancreas, its subregions, tumors, and surrounding OARs from one MRI volume. Methods: The model uses a shared MedNeXt encoder-decoder with supervised whole-pancreas and subregion pretraining, followed by multitask fine-tuning. Three output heads predict the pancreatic subregions, tumor, and OARs (stomach, duodenum, kidneys). An annotation-aware loss allows training on partially labeled data without treating unannotated structures as background. Pancreas and tumor were evaluated by three-fold cross-validation on 142 PANTHER patients (92 diagnostic, 50 MR-Linac), subregions and OARs on Cyst-X and AMOS test sets, and pancreas and OARs on 33 external T1-weighted TotalSegmentator scans. Comparisons with nnU-Net, MedNeXt, VISTA3D, and Swin UNETR used the Dice similarity coefficient (DSC) with paired bootstrap 95% CIs. Results: Pancreas-MedNeXt achieved the highest mean pancreas and tumor DSC on diagnostic and MR-Linac MRI. Tumor DSC was 58.41% and 42.55%, exceeding task-specific MedNeXt by 4.94 (95% CI: 0.28-9.45) and 5.89 (95% CI: 2.37-9.72) percentage points, respectively. Whole-pancreas DSC was 85.73% and 70.66%. Pretraining improved head, body, and tail DSC by 2.01, 3.00, and 3.78 percentage points over training from scratch. It also achieved the highest DSC for the pancreas, duodenum, and right kidney on AMOS, and for all five organs on external MRI, exceeding the next-best method by 4.92-8.85 percentage points.Conclusion: A single Pancreas-MedNeXt model segments tumors, pancreatic subregions, and OARs on diagnostic and MR-Linac MRI, which could streamline contouring for pancreatic cancer radiotherapy.

0.19

Report Supervision

cs.CV ·2026-08-27 ·Pedro R. A. S. Bassia, Wenxuan Li, Jakob Wasserthal, Jieneng Chen, Xinze Zhou +8 more
published similarity 0.69
Abstract · Published in Medical Image Analysis, 2026

Segmentation models can surpass radiologists, classification models, and vision-language models in tumor detection. Importantly, segmentation models outline tumors, allowing radiologists to better verify and trust the AI output. Their main limitation is the scarcity of tumor masks: creating one 3D tumor mask takes up to 30 minutes, so most public CT datasets contain only a few hundred masks, and even the largest private datasets contain only a couple of thousand. Tumor masks are not produced in clinical routine, but radiology reports are. Public datasets contain tens of thousands of CT-Report pairs, and hospitals contain hundreds of thousands. These reports describe tumors in detail, providing large-scale, informative training data. Here, we introduce Report Supervision (R-Super), a training framework that uses reports to directly supervise and improve tumor segmentation. R-Super introduces new loss functions that teach segmentation models to segment tumors that match report descriptions of tumor count, sizes, and locations. Reports are only used for training. We evaluated R-Super on kidney and pancreatic tumor segmentation, exploring diverse training data sizes, up to 41,418 CT-Report plus 3,488 pancreatic tumor CT-Mask pairs. On external validation, R-Super increased tumor detection F1-Score and segmentation DSC by up to +15% with respect to mask-only training. It also surpassed alternative methods such as CLIP and multi-task learning. Leveraging numerous readily available reports to supplement scarce masks, R-Super strongly improves AI performance when very few training masks are available (e.g., 50), and when many masks are available (e.g., 3,488), unlocking scale in tumor segmentation.

0.20

Merlin Plus: A Large-Scale, Multi-Cancer, Image-Mask-Report Dataset

cs.CV ·2026-09-29 ·Pedro R. A. S. Bassi, Wenxuan Li, Szymon Plotka, Ruby Honjol, Jakub Przado +8 more
top venuedatasetcode/data similarity 0.68
Abstract · MICCAI 2026

Multi-cancer segmentation in computed tomography (CT) is fundamentally limited by the scarcity of tumor masks across different organs. We present Merlin Plus, the first large-scale CT dataset with radiologist-created tumor masks across 9 organs. Merlin Plus extends the Merlin dataset by adding 1,153 per-voxel tumor masks and longitudinal metadata. To create these tumor masks, we developed a report-based active-learning framework in which radiology reports identify tumor cases for annotation and support training of a tumor segmentation model. The model generates initial masks, which radiologists review and correct to produce the final masks, reducing annotation burden while maintaining high-quality annotations. Besides tumor masks, the longitudinal metadata in Merlin Plus enables temporal modeling of cancer progression. By directly addressing the major bottleneck of limited multi-cancer segmentation masks, Merlin Plus supports scalable multi-organ cancer detection, segmentation, and longitudinal analysis in CT. Dataset is available at: https://github.com/MrGiovanni/MerlinPlus

0.57

Medical Image Segmentation: Foundation Model Adaptation versus Task-Specific Training

cs.CV cs.AI ·2026-11-10 ·Emre Kutlusan, Yongmin Li
benchmark similarity 0.67
Abstract

Foundation models pretrained on large natural-image collections are increasingly adapted for medical image segmentation, in the expectation that they will replace models trained for each task. Most comparisons, however, use data from the training distribution and a single task-specific baseline whose configuration is rarely justified, and therefore provide limited evidence of performance at new clinical sites. It also remains unclear how much of a foundation model must be adapted, and what determines this. We adapted a foundation model, DINOv2, with strategies ranging from tuning only its bias terms to full fine-tuning, and compared it with U-Nets and ResU-Nets trained from scratch. Experiments covered colonoscopy, breast ultrasound and dermoscopy, with testing on held-out data from the training source and on independent datasets from other institutions. The adapted foundation model generalised better on every external dataset. Within the training distribution, the task-specific models remained competitive when training data were abundant, and delineated boundaries more precisely, while the foundation model more often missed small lesions. Only a small fraction of the foundation model required adaptation, and the capacity needed was determined by the imaging domain rather than by the adaptation method. A widely used polyp test set was also found to duplicate images from another benchmark. Foundation-model adaptation is therefore warranted where models must work across sites, with capacity selected on the target domain.

0.11