CS Paper Radar

Region-Weighted Losses and Model Fusion for Cross-Modal PET Attenuation Correction

Khoa Tuan Nguyen, Joris Vankerschaver, Wesley De Neve

cs.CV ·submitted 2026-08-22 09:49 UTC · v1
publishedbenchmark

Abstract

We describe our approach to the Big Cross-Modal Attenuation Correction (BIC-MAC) challenge, which asks for a pseudo-CT in Hounsfield Units to be synthesized from Non-Attenuation-Corrected PET (NAC-PET), DIXON MRI and a topogram, and scores both the pseudo-CT and the Attenuation-Corrected PET (AC-PET) reconstructed from it. Three ideas carried our improvements over the organizers' 3D U-Net baseline. The loss matters more than the architecture: we compute the $L_1$ error in the Carney attenuation-coefficient ($μ$) space that the CT metric itself uses, weighted by anatomical region. Only once that loss was in place did the unregistered DIXON MRI work as extra input channels. A fixed convex combination of two independently trained models then beat both of its members on three of the four metrics and ranks first overall on the public validation leaderboard.

Comment
ntkhoa team submission for BIC-MAC MICCAI26 challenge (https://www.codabench.org/competitions/12555/#/results-tab)

Closest papers

Nearest neighbours by meaning across the whole index.

Multimodal pseudo-CT synthesis for PET attenuation correction using separate modality encoding and topogram conditioning

eess.IV cs.CVphysics.med-ph ·2026-08-21 ·Rory Bell, Artemis Bouzaki, Jiaming Cao, Jasmine Morrison, Chelsea Sargeant
code/data similarity 0.77
Abstract · Technical report for the BIC-MAC 2026 Challenge

We participated in the BIC-MAC Challenge with a multimodal 3D patch-based U-Net for pseudo-CT generation from NAC-PET, MRI, and 2D topograms. By using separate PET and MR encoders, multi-scale feature fusion, and FiLM-based topogram conditioning at the bottleneck, we obtain a model that integrates complementary cross-modal information while reducing reliance on precise voxel-wise correspondence between modalities. Our final submission can be found: https://github.com/rrr-uom-projects/BIC-MAC-MICCAI2026

0.17

Anatomical and Physical Supervision for CT-less PET Attenuation Correction: BIC-MAC 2026 Challenge

cs.CV ·2026-08-16 ·Petros Chatzitoulousis, George K. Matsopoulos
similarity 0.74
Abstract · 6 pages, 1 table. Technical report for the BIC-MAC 2026 Challenge

This report describes our submission to the Big Cross-Modal Attenuation Correction (BIC-MAC) 2026 Challenge for CT-less PET attenuation correction through multimodal pseudo-CT synthesis. We build upon a standard nnU-Net architecture and combine anatomical and physical supervision to improve both pseudo-CT quality and downstream PET reconstruction. Anatomical supervision is introduced through a frozen TotalSegmentator feature extractor, anatomy-guided structural constraints and patch sampling, while physical supervision is achieved using a differentiable attenuation correction factor projection loss based on multi-angle attenuation projections. Furthermore, the network is initialized with pretrained weights obtained from training on the SynthRAD Challenge MR-to-CT dataset. Minimal architectural modifications are applied, while performance improvements are pursued across the nnU-Net pipeline, including preprocessing, plans, and supervision design, among other components. Our final submission demonstrates the effectiveness of combining anatomical supervision, attenuation physics, and efficient nnU-Net scaling for CT-less PET attenuation correction.

0.07

Geometry-anchored PET-aware multimodal pseudo-CT synthesis for whole-body attenuation correction: the BIC-MAC Challenge

cs.CV ·2026-08-19 ·Xuan Loc Nguyen, Hoang-Loc Cao, Truong Thanh Hung Nguyen, Phuc Ho, Phuc Truong Loc Nguyen +2 more
published similarity 0.73
Abstract · Challenge paper for the Big Cross-Modal Attenuation Correction (BIC-MAC) Challenge at MICCAI 2026

The BIC-MAC challenge targets whole-body pseudo-CT synthesis from NAC-PET, Dixon MRI, and a 2D topogram for CT-less PET attenuation correction. We propose GeoPACT, a geometry-anchored multimodal framework that uses NAC-PET as the spatial reference and incorporates topogram and MRI features through gated residual fusion. Absolute coordinates and whole-body conditioning support anatomically consistent patch-based prediction. Training combines attenuation-map supervision with a differentiable PET-response surrogate to reduce errors relevant to downstream PET reconstruction. Full-resolution pseudo-CT volumes are generated using sliding-window inference without requiring CT or PET labels at test time.

0.27

Evidence Before Accuracy: A MRI-PET Fusion Network for Alzheimer Disease Classification with Causal Regional Validation

cs.CV ·2026-09-28 ·Saeid Firouzi Daghigh, Saeed Ayat
similarity 0.67
Abstract

Deep learning models for Alzheimer disease (AD) classification routinely report near-perfect discrimination, yet few are shown to rest on AD-relevant neurobiology rather than on dataset artifacts, subject-level leakage, or non-brain image content. We present a fusion network combining T1 MRI and FDG PET across axial, coronal, and sagittal planes, trained on ADNI consists of 554 paired subjects. The fusion model reaches AUC 0.962, accuracy 0.909, and F1 0.891, competitive with recent 3D CNN and multimodal transformer systems at substantially lower cost. We first quantify how much modality, plane and slice geometry matter. A validation-only search over slice centres and neighbour spacings moves AUC by 0.180 for MRI and 0.078 for PET, selecting narrow spacing for MRI and wide spacing for PET, with the chosen coronal centres falling on the hippocampal body and on the posterior cingulate respectively. The contribution, however, is the evidence layer built around that number. Shortcut controls collapse the model to AUC 0.622 (silhouette), 0.608 (exterior), and 0.500 (blank), and a label-permutation null yields 0.456. Forward region-of-interest (ROI) ablation shows that masking medial temporal cortex in MRI and the posterior default-mode network (DMN) in PET produces the largest shift in the AD logit, while area-matched controls remain indistinguishable from that null. Reverse ROI ablation shows that the medial temporal lobe alone retains 89.2% of above-chance discrimination in MRI and the posterior DMN alone retains 79.0% in PET. A quantitative comparison of attribution methods shows occlusion sensitivity reaching 3.5-5.0* enrichment inside a priori AD regions against 0.10-0.43* in controls. Ablation and attribution independently establish a biologically correct double dissociation: hippocampal evidence is carried by MRI, posterior cingulate evidence by PET.

0.12

Image-Condition-Controlled Diffusion Network with Large-Scale CT Pretraining for CT-Free Attenuation Correction in Dynamic Cardiac PET

cs.CV ·2026-11-18 ·Zhejia Zhang, Scott M. Leonard, Jinkui Hao, Ryan J. Avery, Richard L. Weinberg +1 more
similarity 0.67
Abstract · 11 pages, 6 figures, 3 tables. Submitted to IEEE Transactions on Radiation and Plasma Medical Sciences

Positron emission tomography (PET) provides quantitative information on myocardial perfusion. In dynamic PET, tracer kinetics are tracked through a series of reconstructed time frames. Reliable attenuation correction is essential for accurate measurements. Clinical attenuation maps ($μ$-maps) are typically derived from computed tomography (CT), which adds radiation exposure and may introduce PET-CT misregistration due to respiratory and cardiac motion. Moreover, supervised CT-free methods rely on paired non-attenuation-corrected (NAC) PET and CT data, which are scarce, whereas large-scale unpaired CT data are more readily available. To address these challenges, we propose Large-scale Unpaired CT-Informed Diffusion (LUCID), a framework that transfers anatomical priors learned from 10,000 chest CT volumes in the public CT-RATE dataset to $μ$-map synthesis for dynamic cardiac $^{82}$Rb PET. First, a convolutional neural network (CNN) predicts an initial $μ$-map from each NAC PET frame. Second, the CT-pretrained diffusion backbone refines a low-noise perturbation of the CNN prediction through a single denoising step, conditioned on the corresponding NAC PET frame via ControlNet. Finally, frame-wise predictions are averaged voxel-wise to obtain the final $μ$-map. We further introduce the voxel-wise temporal standard deviation (TSD) to quantify inter-frame variability without requiring a reference $μ$-map. We evaluated LUCID on an in-house dataset of 102 patients and found that it achieved the best quantitative accuracy while maintaining competitive inter-frame consistency. Ablation studies showed that refinement with a diffusion backbone pretrained on in-house CT data from the training patients was less accurate than the CNN prediction alone, highlighting the importance of large-scale CT pretraining.

0.22

MedicalDPO: Multi-Objective Direct Preference Optimization for CT to PET Translation

cs.CV ·2026-11-16 ·Huiting Zhang, Yingxin Cai, Siyuan Wang, Xi Yang, Yuyao Yan +2 more
similarity 0.64
Abstract

CT-to-PET synthesis estimates functional PET images from anatomical CT scans for auxiliary analysis, representation pretraining, and missing-modality completion. Brownian Bridge diffusion models can produce multiple PET candidates of different quality under the same CT condition, exposing an intra-condition quality hierarchy. Candidate quality spans complementary spatial, structural, and intensity dimensions, while DPO-only fine-tuning may compromise absolute synthesis fidelity. We propose MedicalDPO which converts this hierarchy into preference supervision automatically constructed from paired CT-PET training data. Multiple candidates are ranked across the three fidelity dimensions, and strict cross-metric verification retains preferred-rejected pairs with consistent quality separation. Relative denoising-error preference optimization is jointly trained with the original Brownian Bridge objective to anchor the pretrained CT-to-PET mapping, while condition-balanced multi-pair rotation distributes preference supervision across CT conditions. Experiments on BBDM and CPDM show improvements across LPIPS, MAE, SSIM, and PSNR. Further analyses demonstrate metric complementarity and clear pair separation, while ablations show that the original training objective prevents the substantial degradation caused by DPO-only fine-tuning.

0.24

M3-Score: Fidelity, Memorization and Coverage as Separate Axes for Evaluating Generative Radiology Image Models

cs.CV ·2026-09-27 ·Sathiyamohan Nishankar, Pubudu Sanjeewani, Asanka Perera
similarity 0.63
Abstract

Quantitative evaluation of generative models for radiology remains challenging. Clinically relevant structures are often small and infrequent, feature spaces learned from natural images may represent them poorly, and a single summary score cannot distinguish limited fidelity from limited diversity. This study proposes the Medical Multi-axis Maximum Mean Discrepancy score (M3-Score), an evaluation framework based on RadioDINO-s16, a frozen vision transformer pretrained on radiology images. M3-Score reports three complementary axes computed at pre-specified encoder depths: \emph{fidelity}, measured by an unbiased multi-bandwidth radial basis function (RBF) MMD$^2$ at the final block; \emph{memorization}, measured by nearest-neighbor distances at 75\% depth; and \emph{coverage}, defined as the fraction of real images with a generated neighbor within their $k$-nearest-neighbor radius at 33\% depth. Reference sets are sampled across subjects to limit the influence of correlated slices. On BraTS brain MRI, the fidelity axis ordered five comparison sets of increasing severity (Spearman $ρ= 1.00$), and a subject-disjoint real set yielded $\mathrm{MMD}^2 = 0$ (permutation $p = 1$). An unconditional denoising diffusion probabilistic model achieved $\mathrm{MMD}^2 = 0.073$ (95\% confidence interval $[0.071, 0.080]$) but covered only 38\% of the real distribution. Under progressive mode dropping, $k$-NN manifold recall increased at all twelve encoder blocks, whereas the proposed coverage estimator decreased monotonically ($ρ= -1.00$). RadioDINO-s16 features separated real brain MRI from generated samples with a ROC-AUC of 0.819, compared with 0.555 for InceptionV3 and 0.582 for CLIP. Across a twentyfold range of sample sizes, the mean M3 value varied by a factor of 1.05, compared with 2.52 for the Fréchet Inception Distance.

0.21

VoxForge: A Unified Foundation Model for Dense 3D Features Across MRI, CT and PET

cs.CV cs.LG ·2026-11-19 ·Rushil Anirudh, Jayaraman J. Thiagarajan
similarity 0.63
Abstract · 34 pages (8-page main paper, references, and 23-page supplementary material), 7 figures. Rushil Anirudh and Jayaraman J. Thiagarajan contrib…

A unified 3D medical foundation model promises reusable, frozen features that serve a wide variety of tasks such as segmentation, classification and registration on MRI, CT and PET as well as specialist models do. Generalist models still need separate backbones for localized and global tasks, specialist models are confined to a single modality, with the concern that spanning modalities under-emphasizes fine anatomy, and both typically rely on end-to-end fine-tuning to be competitive. We present VoxForge, a single encoder that integrates recent advances in 3D architecture, self-distillation and cross-modal curricula to learn transferable features from permissively licensed MRI and CT volumes. We evaluate it strictly frozen, the test a reusable foundation model must pass, against state-of-the-art generalist and specialist models on segmentation, classification and registration across MRI and CT, and on PET, which it never sees. VoxForge has the best or tied-best average rank in every task group, serves localized and global tasks across modalities at the level of state-of-the-art specialists, and is extremely label-efficient, matching top-performing models on TotalSegmentator CT with a tenth of the labels.

0.17