CS Paper Radar

MnemoDyn: Learning Resting State Dynamics from 40K FMRI sequences

Sourav Pal, Viet Luong, Hoseok Lee, Tingting Dan, Guorong Wu, Richard Davidson, Won Hwa Kim, Vikas Singh

cs.LG ·submitted 2026-08-25 00:52 UTC · v1
published

Abstract

We present a dynamical-systems based model for resting-state functional magnetic resonance imaging (rs-fMRI), trained on a dataset of roughly 40K rs-fMRI sequences covering a wide variety of public and available-by-permission datasets. While most existing proposals use transformer backbones, we utilize multi-resolution temporal modeling of the dynamics across parcellated brain regions. We show that MnemoDyn is compute efficient and generalizes very well across diverse populations and scanning protocols. When benchmarked against current state-of-the-art transformer-based approaches, MnemoDyn consistently delivers superior reconstruction quality. Overall, we find that with such large-scale pre-training on (non-proprietary) rs-fMRI datasets, we get a highly performant model for various downstream tasks. Our results also provide evidence of the efficacy of the model on small sample size studies which has implications for neuroimaging studies at large where resting state fMRI is a commonly acquired imaging modality.

Comment
ICLR 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Natural Image Autoencoder-Based fMRI Representations for Trait and State Prediction

cs.CV ·2026-09-28 ·Juhyeon Park, Yeonwoo Kim, Peter Yongho Kim, Yansen Wang, Mingqing Xiao +3 more
similarity 0.71
Abstract · Under Review

Foundation models pre-trained on large-scale fMRI datasets have shown strong downstream performance, but at substantial data and computation cost. To investigate how much fMRI-specific pre-training is actually needed for such performance, we introduce FReD, which derives fMRI representations from a frozen Deep Compression AutoEncoder (DCAE) pre-trained exclusively on natural images and pairs them with a task specific readout. For trait prediction, FReD summarizes frame-wise representations by their temporal mean and log-standard deviation and applies linear probing, with late fusion across two normalization schemes. For state prediction, it represents each frame as a single token and models temporal dependencies with a shallow Transformer. Across four resting-state datasets spanning six trait-prediction targets, linear probes on frozen DCAE features generally outperform those on fMRI foundation model representations and remain competitive with fully fine-tuned fMRI foundation models. On three task-fMRI state-prediction tasks, a temporal readout on DCAE features performs comparably to the strongest foundation models evaluated. A Gaussian injection analysis further shows that localized signal changes are recovered more accurately from the frozen DCAE features than from the evaluated foundation-model representations. Together, these results show that strong performance on current fMRI benchmarks is possible without fMRI-specific representation pre-training, making frozen natural-image features as a useful baseline for assessing its added value.

0.17

dMRI-F: A Foundation Model for Generalizable Diffusion MRI Analysis from Sparse Acquisitions

cs.CV ·2026-10-13 ·Xi Zhu, Yijie Li, Xiaofan Wang, Wei Zhang, Huafu Chen +2 more
similarity 0.70
Abstract

Diffusion MRI (dMRI) probes water diffusion within the brain, providing unique information about tissue microstructure and white matter connectivity. High-quality dMRI enables advanced and accurate analyses but demands dense acquisitions, resulting in long scan times and hardware constraints that are often infeasible. Further, dMRI requires dedicated computational methods to support diverse analysis tasks (e.g., parcellation, registration, and synthesis) for both neuroscientific and clinical applications. Here, we present dMRI-F, a foundation model that unifies dMRI data enhancement and downstream tasks across diverse acquisitions and populations, while requiring only minimal acquisition input. dMRI-F is pre-trained with a q-space masked reconstruction task: predicting densely sampled multi-shell data from only six volumes. It learns generalizable latent feature representations of dMRI data, which serve as a core foundation for adapting to diverse downstream tasks, including brain parcellation, brain registration, and cross-modal synthesis. Across nine independently acquired datasets, we demonstrate that dMRI-F outperforms state-of-the-art methods with robust generalization across acquisitions, populations, and tasks. Our results demonstrate dMRI-F's versatility as a general-purpose framework that enables diverse dMRI applications from low-cost, sparse acquisitions.

0.15

One Block Is Enough: LoopMR for Accelerated MRI Reconstruction

eess.IV cs.CV ·2026-11-11 ·Yimeng He, Yibin Xie, Yi Zheng, Yifan Gao, Lixia Wang +5 more
code/data similarity 0.68
Abstract · 10 pages, 7 figures, 6 tables. Code: https://github.com/hym97/LoopMR

Deep-learning unrolled networks are the leading approach to accelerated MRI reconstruction. State-of-the-art models such as PromptMR+ learn a distinct block for every cascade, so their size grows with the number of cascades. Sharing one block across iterations avoids adding parameters, but earlier shared-weight models typically used a tiny block and produced worse images than models with distinct weights. Therefore, it remained unclear whether weight sharing itself or the choice of block was the problem. Recent advances in looped transformers, which reuse the same block across layers, show that they can match or outperform their distinct-weight counterparts on several tasks. Motivated by this, we propose LoopMR, which reuses a single Restormer block at every iteration as its core. Besides the current image estimate, the block receives data-consistency inputs and latent images. On four datasets covering the brain (CC359), knee (fastMRI), heart (CMRxRecon2023) and carotid (in-house), LoopMR significantly outperforms E2E-VarNet, PromptMR and PromptMR+ in PSNR and SSIM at every acceleration factor (p < 0.01), with about 1/9 of PromptMR+'s parameters (10.3M versus 92.9M). It also keeps its lead at unseen acceleration factors and on an unseen dataset. With our transformer block, the shared model matches or outperforms its distinct-weight counterpart at 6, 12 and 24 iterations. At a fixed number of iterations, shared transformer blocks match or outperform their distinct-weight versions, while shared CNN blocks perform worse. These results suggest that looping one well-chosen block can outperform stacking distinct cascades in MRI reconstruction, with a fraction of the parameters.

0.25

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

cs.CV ·2026-10-06 ·Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
publishedcode/data similarity 0.68
Abstract · Accepted at ECCVW 2026

Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction.

0.31

FAST-Brain: A Flow-Aligned Spatio-Temporal Surrogate Brain Model

cs.LG q-bio.NC ·2026-09-28 ·Shucheng Liu, Changchun Shi, Kai Zhang, Hongtu Zhu
similarity 0.67
Abstract

Modeling resting-state functional magnetic resonance imaging (rs-fMRI) data is crucial for understanding brain-wide neural activity. However, traditional methods struggle to capture complex temporal dynamics over long horizons, to account for the brain's anatomical spatial structure, and to model high-dimensional ambient signals that lie on a low-dimensional intrinsic subspace. We propose FAST-Brain, a unified flow-aligned spatio-temporal surrogate brain model that addresses all three challenges. At its core is a flow-aligned generative framework that directly predicts the clean blood-oxygen-level-dependent (BOLD) signal, paired with a graph convolutional network that captures spatial structural constraints and a Transformer that models long-range temporal dependencies. Theoretically, we show that under a low-dimensional subspace assumption, the approximation error of our model scales with the intrinsic dimension rather than the ambient dimension, which justifies our direct modeling of the BOLD signal. Extensive experiments on synthetic and Human Connectome Project datasets demonstrate that FAST-Brain achieves state-of-the-art performance in recovering functional connectivity, effective connectivity, and the implicit low-dimensional signal subspace.

0.15

Scalable Unrolled Chains for MRI Reconstruction

cs.CV ·2026-10-24 ·Emiljo Mëhillaj, Ender Konukoglu
publishedcode/data similarity 0.66
Abstract · 23 pages (including supplementary material), 14 figures. Accepted at WACV 2027

Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibitively memory intensive as the number and width of cascades increase. We propose a memory-efficient training framework that updates a randomly sampled cascade while retaining supervision from the final reconstruction loss. The error signal is propagated from the end of the chain to the sampled cascade using an activation-light backward pass that avoids storing full chain activations, thereby decoupling training memory from chain length. A time-conditioned network shared across cascades further keeps the parameter count independent of chain length. The backward pass is approximate only through frozen normalization statistics, and a trained exact gradient control shows the approximation leaves reconstruction quality unchanged. The framework remains trainable at chain lengths and cascade widths where standard end-to-end backpropagation exhausts GPU memory. On fastMRI single-coil knee and multi-coil brain reconstruction, our method consistently outperforms other local training approaches. On high-SNR knee slices, our method surpasses E2E-VarNet at $8\times$ and matches it at $4\times$, while on the complete brain validation set it surpasses E2E-VarNet at $8\times$ and achieves comparable performance at $4\times$, with fewer parameters, lower peak memory, and faster per-iteration training. Code is available at https://github.com/emehillaj/scalable-unrolled-mri.

0.50

Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction

eess.IV cs.CV ·2026-11-11 ·Hong Shang, Zijian Zhan, Sen Jia, Xiang Fan, Jintao Meng +8 more
similarity 0.66
Abstract

Deep-learning-based magnetic resonance imaging (MRI) reconstruction holds great promise for accelerating acquisitions, yet its clinical translation remains bottlenecked by poor generalizability across unseen scanners, populations, anatomies, and protocols. Gathering sufficiently diverse clinical datasets to overcome this bottleneck is hindered by high acquisition costs, privacy restrictions, and institutional biases. Here, we introduce Scalable Inverse Model (SIM), a framework that systematically co-designs physics-simulated training data, model architecture, and learning paradigms around scalability--leveraging compute scaling to overcome historical data bottlenecks and achieve robust zero-shot MRI reconstruction. Across 14 public and in-house datasets--spanning seven international centers, five vendors, field strengths of 0.3-7 T, over ten anatomical regions, more than ten acquisition protocols, downstream quantitative and molecular tasks, and a 150-scan blinded radiologist study--SIM demonstrates robust zero-shot generalizability, recovering fine anatomical details while suppressing aliasing artifacts where conventional deep-learning methods fail. Attention-map analyses confirm that SIM learns physically explainable, dynamically adaptive reconstruction primitives rather than anatomy-specific priors. SIM establishes a scalable, privacy-preserving, and democratized infrastructure for universal MRI reconstruction, providing a blueprint for generalizable AI across inverse problems in medical imaging.

0.22

STAIRS: Staging the Inverse Problem via Admissible-Support Scheduling for Unrolled MRI Reconstruction

cs.CV ·2026-11-06 ·Xiangjian Hou, Chang Ni, Chao Qin, Zhiwei Tan, Xin Wang +4 more
similarity 0.66
Abstract

Accelerated magnetic resonance imaging (MRI) forms images from incomplete Fourier measurements, shifting acquisition burden to computational reconstruction. Deep unrolled networks interleave learned regularization and data consistency, yet typically estimate the full unmeasured spectrum at every cascade. We propose STAIRS (Staging the Inverse Problem via Admissible-Support Scheduling), which projects intermediate reconstructions onto nested Fourier supports that expand to the full spectrum and conditions each update on its support transition. Conditional increments of a regularized log-determinant score of training covariance define a normalized spectral coordinate, accounting for dependencies between newly and previously admitted frequencies. Dyadic targets allocate larger coordinate increments to earlier cascades and are mapped to fixed supports before training, enabling coarse-to-fine reconstruction with unchanged sampling masks and data consistency. On fastMRI and Stanford2D, STAIRS improves matched Transformer (HUMUSNet) and convolutional (NAFNet) backbones in single- and multi-coil reconstruction, including radiologist-annotated pathology regions. It also outperforms predictor-based progression with lower parameter overhead and inference latency. Stage-wise analysis shows repeated error correction by projection and lower intermediate reconstruction errors than the backbones alone throughout support expansion. Ablations favor dyadic allocation over uniform expansion for square and line-band supports and over manual front-loading for square windows. Support projection alone improves reconstruction, and transition conditioning strengthens the gain. Cross-dataset evaluation shows improvements for both backbones in both directions. Support allocation thus complements regularizer design in unrolled MRI reconstruction.

0.22