Validation of HRV Studio: A Transparent and Quality-Control-Aware Platform for Heart Rate Variability Analysis

Cyrus Mexon Evrard Djindot, Faliang Liu, Sylvain Laborde, Yinjia Zhang, Jessie Chen, Ming Li, Congrong Wang, Weixiong Rao, Qinpei Zhao

cs.LG physics.med-phcs.SEq-bio.QM ·submitted 2026-08-25 08:45 UTC · v1
code/data

Abstract

Reproducibility of heart rate variability (HRV) analysis is limited by differences in preprocessing and computational conventions across software platforms. We developed HRV Studio, an open-source PyQt6-based desktop application integrating transparent HRV analysis with automated quality-control (QC) diagnostics. Validation included large-scale agreement with NeuroKit2, targeted Kubios benchmarking, spectral-method comparison, synthetic perturbation testing, recording-duration sensitivity analysis, and arrhythmia-focused QC stress testing. HRV Studio showed near-identical agreement for the widely used time-domain indices RMSSD and SDNN under matched conditions. In the primary five-minute NeuroKit2 comparison, frequency-domain median relative errors were 1.35% for LF, 0.18% for HF, and 1.41% for LF/HF, while VLF remained more convention-sensitive (37.79%). Nonlinear Poincaré indices also demonstrated high consistency. Sequence-harmonized Kubios benchmarking confirmed near-identical agreement for time-domain and nonlinear indices and strong agreement for most frequency-domain measures. Extended ten-minute analyses reproduced the same overall pattern with lower disagreement for some convention-sensitive spectral outputs. Synthetic and arrhythmia stress tests maintained 100% numerical stability while consistently triggering QC warnings. Overall, HRV Studio provides a transparent and reproducible platform for HRV research, with strong cross-platform consistency when NN sequences, preprocessing, and analytical conventions are harmonized. Stress-test results indicate computational robustness rather than clinical validation.

Comment
33 pages, 8 figures. Source code available at https://github.com/CyrusMexon/HRV-Analysis_TJU

Closest papers

Nearest neighbours by meaning across the whole index.

CardioFusion-AI: Robust ECG--PPG Fusion for Multimodal Physiological Monitoring Under Signal Degradation

eess.SP cs.LGq-bio.QM ·2026-08-26 ·Navaneetha Krishnan Kamalakannan, Janakiraman Kamalakannan
code/data similarity 0.59
Abstract · 7 pages, 4 figures. Under review at IEEE Journal of Biomedical and Health Informatics. Code: https://github.com/ka-cyber/CardioFusion-AI

Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fusion strategies that assume both modalities are equally trustworthy can become less reliable than a single clean modality under degradation. We present CardioFusion-AI, a framework whose signal-processing front end, including R-peak and systolic-peak detection, an Orphanidou-type signal-quality index, and beat-by-beat pulse transit time estimation, is validated on 53 real intensive-care recordings (848 windows; heart-rate mean absolute error 1.61 bpm for ECG and 2.78 bpm for PPG) and a real annotated fetal ECG database (R-peak F1 0.89-0.98). We then conduct a controlled synthetic degradation study comparing eight ECG-PPG fusion strategies across six degradation regimes spanning graded corruption and complete modality loss, using five independent training seeds. Attention fusion achieved the lowest descriptive overall error (1.66+/-0.43 bpm). Both adaptive gates reallocated weight toward the healthy modality under complete modality loss, but showed near-zero correlation between gate weight and signal quality under graded degradation (r = 0.10-0.24). Signal-quality conditioning produced a specific improvement under missing-PPG conditions (1.56+/-0.59 bpm), approaching the 1.48 bpm unimodal ceiling. With only five training seeds, no pairwise comparison survives Holm-corrected significance testing; effect sizes and confidence intervals are therefore reported. These results indicate that modality availability and modality quality are functionally distinct problems for adaptive fusion.

0.60

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.58
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

Quality and Similarity Indicators for Video-Based Heart Rate and Respiratory Rate Fusion: A Controlled Evaluation

cs.CV ·2026-11-16 ·Nhi Nguyen, Le Nguyen, Manuel Lage Cañellas, Miguel Bordallo López, Constantino Álvarez Casado
similarity 0.56
Abstract · 15 pages, 7 figures, 4 tables; with 14 pages supplementary material included

Camera-based heart rate (HR) and respiratory rate (RR) estimates vary in reliability from window to window, and a common remedy is to fuse several extraction methods with weights from reference-free signal quality indicators. However, few studies test whether these indicators identify the most accurate method in each window or outperform simpler fusion. We evaluate 11 quality indicators and 8 inter-method similarity measures for fusing 7 HR and 10 RR extractors on four public datasets (75 test subjects). Filters, indicator directions, weighting parameters and a learned ridge baseline are selected on a separate five-subject set before testing. Fusion is compared with equal averaging, a constant typical-rate predictor, the best single method selected in advance and in hindsight, and a per-window oracle with a permutation-based null, using subject-level bootstrap confidence intervals. For HR, quality-weighted fusion reduced mean absolute error by 10.9% [5.2, 18.4] relative to averaging and by 15.6% [8.1, 23.1] relative to the method selected in advance, and was statistically indistinguishable from the best method selected in hindsight. Weighting methods by their agreement did not improve on averaging. For RR, the indicators could not identify the more accurate estimates: sharpened quality weighting increased error (-2.6% [-4.8, -0.8]), fused estimates were uncorrelated with the reference (r <= 0.22), and averaging was less accurate than the typical-rate predictor (-3.1% [-6.1, -0.4]). With a second respiratory reference, apparent RR gains reflected estimates moving toward its typical rate. Quality-guided fusion is worthwhile for video HR; for RR, 30-s windows improved estimates but not fusion.

0.26

Interaction-Gated Time-Frequency Learning for Parameter-Efficient PPG-Based Heart Rate Estimation

cs.LG cs.AIeess.SP ·2026-10-20 ·Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham
benchmark similarity 0.56
Abstract · Conference preprint, accepted at SoICT 2026

Photoplethysmography (PPG) enables low-cost and non-invasive heart rate (HR) monitoring but remains sensitive to waveform distortion, physiological variability, and measurement interference. Temporal waveform characteristics and frequency-domain periodicity provide complementary information for HR estimation; however, effectively exploring and integrating these representations within a compact model remains challenging. This paper proposes TF-IG, a parameter-efficient interaction-gated time-frequency learning framework for PPG-based HR estimation. TF-IG employs a dual-branch architecture in which a temporal branch captures pulse morphology via dilated depthwise-separable convolutions, while a frequency branch extracts cardiac periodicity information from bounded log-spectrogram representations. To combine the two domains, we introduce an interaction-gated fusion module that explicitly models feature agreement and discrepancy, while also learning feature-wise weights to balance temporal and spectral information. A parameter-shared regression head further maps the temporal, spectral, and fused representations into the final HR prediction space. Experiments on the benchmark BIDMC PPG and Respiration Dataset using a subject-exclusive training, validation, and test protocol show that TF-IG achieves a mean absolute error (MAE) of 1.227 BPM, a root mean square error (RMSE) of 2.060 BPM, a Pearson correlation coefficient of 0.9934, and 92.28 percent of estimates within 3 BPM, while remaining parameter-efficient with only 84.6K parameters. Ablation results further demonstrate the complementary contributions of the temporal and frequency branches, interaction-gated fusion, and shared regression head. These results indicate that explicitly modeling cross-domain interactions provides an effective accuracy-complexity trade-off for lightweight PPG-based HR estimation.

0.11

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.56
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55

ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals

eess.SP cs.CLcs.MS ·2026-09-15 ·Shovito Barua Soumma, Asiful Arefeen, Hassan Ghasemzadeh
similarity 0.56
Abstract · Under Review

Accurate heart rate (HR) and interbeat interval (IBI) estimation from wearable electrocardiogram (ECG) is essential for continuous physiological monitoring, but motion artifacts can create false QRS-like peaks and obscure true R-peaks. Conventional detectors and local interval-repair rules process detections independently and may become unreliable when several consecutive beats are corrupted. We present ARTA (Artifact-Robust Temporal Alignment), a graph-based combinatorial framework that estimates the heartbeat sequence through constrained temporal optimization. ARTA combines candidates from multiple ECG detectors, represents them as nodes in a directed acyclic graph and connects candidates through physiologically plausible RR intervals. Candidate confidence uses detector agreement and local ECG quality, while history-dependent transition costs capture recent IBI consistency and a soft heart-rate prior. Beam-search dynamic programming selects a coherent low-cost path across the recording, suppressing false detections and recovering missed beats when plausible auxiliary candidates are available. On the IEEE Signal Processing Cup exercise dataset with electrode-motion artifacts from -2 to 12 dB, ARTA achieved an HR mean absolute error of 1.79 beats per minute, 54% lower than the strongest single-detector baseline, with 92.38% of windows within +/-5 beats per minute, an R-peak F1 score of 0.95, and an IBI mean absolute error of 6.52 ms. Cross-dataset evaluation on the European ST-T Database further assessed transfer to long clinical ambulatory recordings and a label-free reliability analysis examined conditional performance without using reference annotations for segment selection. ARTA is single-channel, training-free, interpretable and computationally lightweight, operating approximately 27 times faster than real time with peak memory below 2.1 MB in a single-thread CPU simulation.

0.17

Evaluating Generalization and Long-Term Stability of Smartwatch-Based Cuffless Blood Pressure Monitoring

eess.SP ·2026-10-29 ·Hongda Huang, Xiao Peng, Xiaoyu Li, Shuailong Tang, Guangpu Zhu +4 more
published similarity 0.55
Abstract · Accepted by the 2026 IEEE EMBS International Conference on Biomedical and Health Informatics (BHI 2026)

Smartwatch-based cuffless blood pressure (BP) monitoring is a promising low-burden solution for long-term cardiovascular management, but practical deployment remains constrained by model complexity, uncertain cross-dataset generalization, and insufficient evidence on long-term tracking stability. This study presents an efficient Signal-Context Gated Fusion Network (SCGBPNet) for cuffless BP estimation from photoplethysmography (PPG) signals. SCGBPNet integrates signal-level representations through self-attention and further incorporates subject-specific contextual information via a compact gated fusion module. On Aurora-BP, SCGBPNet achieved SBP/DBP mean absolute errors (MAEs) of 7.08/4.90 mmHg, compared with 6.44/4.89 mmHg under within-dataset validation on the private smartwatch dataset, indicating a modest within-dataset discrepancy. Cross-dataset transfer from Aurora-BP to the smartwatch dataset increased the MAEs to 8.98/6.47 mmHg, demonstrating substantial cross-dataset degradation. For long-term stability, the proposed method showed low week-to-week performance variation and a low daily decay rate, indicating good stability over a follow-up period of more than one month. Nevertheless, estimation accuracy deteriorated when BP deviated substantially from an individual's baseline. These findings indicate that favorable aggregate MAE alone should not be interpreted as evidence of deployment-ready performance. More systematic and stratified evaluation across dataset settings, BP ranges, and baseline-deviation levels is needed to assess the practical reliability of smartwatch-based cuffless BP monitoring.

0.25

Learning from VAE Errors to support ECG-based Differential Diagnosis of Myocardial Scar

cs.LG stat.ML ·2026-09-04 ·Shayan Sharifi, Riccardo Treu, Ilaria Gandin, Federico Garoia, Marco Merlo +1 more
similarity 0.54
Abstract · Accepted at the PharML Workshop, ECML PKDD 2026

Late Gadolinium Enhancement (LGE) on cardiac magnetic resonance is a key marker of myocardial scar, but its limited accessibility motivates routine ECG-based screening. We evaluated whether $β$-variational autoencoder (VAE)-derived ECG representations can discriminate LGE+ from LGE- cardiomyopathic patients in a local cohort of 300 subjects. We compared 32-dimensional features from the foundation ECGx.AI model with those from a shallower $β$-VAE trained on normal PTB-XL ECGs, evaluating downstream classification and Dynamic Time Warping (DTW)-based reconstruction errors. ECGx.AI reached an area under ROC of 0.686 with Random Forest, while the proposed $β$-VAE reached 0.577 with sensitivity of 0.775 with Gradient Boosting. Notably, DTW-reconstruction errors significantly differed between classes in 10 out of 12 leads according to Mann-Whitney U test and help in classification, leading to an area under ROC of 0.643 with Logistic Regression, supporting their potential as markers of scar-related ECG alterations.

0.22