CS Paper Radar

Deep Learning Segmentation of Diffusion-Weighted MRI Acute Ischaemic Stroke: A Pragmatic Evaluation Across Three Datasets

Atle Bjørnerud, Till Schellhorn, Thor H. Skattør, Terje Nome, Jon André Ottesen, Anne Hege Aamodt, Bradley J MacIntosh

cs.CV ·submitted 2026-08-26 11:53 UTC · v1

Abstract

Objective: Diffusion-weighted MRI (DWI-MRI) is the gold standard for visualizing and quantifying acute ischaemic stroke (AIS). Although deep learning methods can accurately segment AIS lesions, the optimal image inputs and model architecture remain uncertain. We evaluated whether accurate AIS lesion segmentation can be achieved using a pragmatic deep learning approach with minimal preprocessing and clinically feasible inference times. Materials and Methods: Self-configured nnU-Net models were trained on 1,744 DWI cases from local, national, and open-access datasets and tested on 436 cases. Four experimental conditions were evaluated using five-fold cross-validation: with or without brain extraction and using either DWI alone or DWI plus apparent diffusion coefficient (ADC) images as inputs. Two architectures were compared: the baseline nnU-Net (base) and a residual encoder nnU-Net (ResEnc). Performance was benchmarked against the DeepISLES ensemble model from the 2022 ISLES challenge. Results: In the test set (n=436), the base model achieved a median (IQR) Dice similarity coefficient (DSC) of 0.84 (0.19). For the base model, only two of six pairwise comparisons between input configurations showed significant differences. ResEnc produced small but significant improvements in DSC compared with the base model for DWI, DWI+brain extraction, and DWI+ADC inputs (all p<0.02), but not for DWI+ADC+brain extraction (p>0.50). The base model significantly outperformed DeepISLES, particularly in patients with smaller infarct volumes (signed-rank test, p<0.01). Conclusions: A baseline nnU-Net trained on DWI alone, without preprocessing, enabled fast and accurate AIS lesion segmentation. This streamlined approach may facilitate clinical research and support acute stroke imaging workflows

Comment
19 pages, 8 figure and 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Ischemic Stroke Segmentation and Net Water Uptake Quantification on Multicenter Non-Contrast CT Using Supervised Target-Domain Adaptation

cs.CV ·2026-09-17 ·Linus Britt, Maximilian Nielsen, Susan Klapproth, Andre Kemmling, Michael H. Lev +3 more
similarity 0.83
Abstract

Objectives: Quantitative assessment of infarct hypodensity on non-contrast computed tomography (NCCT), including net water uptake (NWU), requires manual or semi-manual lesion delineation, often guided by CT perfusion or diffusion-weighted MRI, limiting clinical applicability. Automated segmentation on NCCT could enable efficient biomarker extraction such as NWU but remains challenging across heterogeneous multicenter data. This study aimed to develop and externally test a domain-aware deep learning framework for ischemic stroke segmentation on NCCT and assess its suitability for NWU quantification. Materials & Methods: In this retrospective multicenter study of 801 patients from four datasets, an nnU-Net-based model was trained on NCCT scans from the University Medical Center Hamburg-Eppendorf and the Acute Ischemic Stroke Dataset. To adapt to new domains, the model was fine-tuned on target-domain subsets from Boston (n=11) and ISLES (n=75), with evaluation on held-out cases not used for fine-tuning. Automated segmentations and NWU values were compared with expert references. Results: For lesions $\geq$ 30 mL, median Dice was 0.68 (Boston) and 0.56 (ISLES). Including smaller lesions, which predominated in ISLES, median Dice was 0.54 (interquartile range [IQR] 0.30-0.70) for acute lesion segmentation (Boston dataset) and 0.20 (IQR 0.03-0.41) for NCCT lesion segmentations when compared to post-treatment infarct (primary target of the ISLES challenge). Automated NWU mean absolute error was 1.37 percentage points (SD 1.61, Boston). Conclusion: Target-domain adaptation supported NCCT-only infarct segmentation across heterogeneous external cohorts, although performance varied across domains. The approach enabled low-error NWU quantification from baseline NCCT without advanced imaging, supporting further prospective clinical evaluation.

0.04

Hetero-modal learning and corruption-resistant hetero-modal inference for joint segmentation of white matter hyperintensities and ischaemic stroke lesions in MRI

eess.IV ·2026-09-30 ·Jesse Phitidis, William N. Whiteley, Joanna M. Wardlaw, Miguel O. Bernabeu, Francesco Dalla Serra +1 more
similarity 0.73
Abstract

White matter hyperintensities (WMH) and ischaemic stroke lesions (ISL) are visually confounding, co-occurring pathologies that require large, diverse datasets for robust deep learning segmentation. However, assembling such datasets is hindered by cohort samples that lack reference segmentations from both features and complete sets of MRI structural sequences (i.e., "modalities"). To maximise data utility, we investigate hetero-modal learning using a dataset of 206 vascular disease patients across four MRI sequences (T1-weighted, T2-weighted, fluid-attenuated inversion recovery, and diffusion-weighted imaging) with expert annotations of both WMH and ISL. We demonstrate that hetero-modal learning outperforms models trained using a single imaging modality in scenarios with substantial missing data, including a split where only 10% of the training data contains all four modalities while the remainder is uni-modal, and a split relying on a single shared "anchor" modality with zero overlap between the remaining modalities. Furthermore, models trained under this second split successfully perform inference on unseen combinations of modalities. Yet, while standard hetero-modal networks handle missing sequences, clinical deployment introduces the additional challenge of silent data degradation - where modalities are present but severely corrupted. To bridge this gap, we introduce the Multimodal Attention Router (MMAR) block. Our experiments demonstrate that, when trained with a "corruption augmentation" strategy, the MMAR effectively dynamically weights the encoded features of each modality, maintaining strong performance during hetero-modal inference even in the presence of unflagged catastrophically corrupted modalities.

0.13

Native-Space 3D CarveMix for Multi-Site T1w Stroke Segmentation

eess.IV cs.CV ·2026-08-24 ·Dexter Wen Jie Teo, Kumaradevan Punithakumar
published similarity 0.71
Abstract · Accepted at the SWITCH+ Workshop (ISLES 2026 Challenge), MICCAI 2026. Springer LNCS

Segmenting ischemic stroke lesions on T1-weighted (T1w) MRI acquired across different scanners and protocols without intensity standardization is difficult because lesions are subtle and share intensity characteristics with cerebrospinal fluid. Standard deep learning architectures trained across multiple centers plateau around Dice 0.66, with acute lesions ($\le 7$ days post-stroke) performing substantially worse due to severe sample scarcity. We combine a MedNeXt-L ($k=5$) backbone with on-the-fly 3D CarveMix augmentation that pastes real lesion patches into healthy brain regions during training. By generating synthetic lesion placements dynamically within each fold with subject-level split isolation, the model sees more diverse lesion patterns without requiring pre-generated copies on disk. We evaluate on 1,453 native T1w scans from 55 clinical centers in the ISLES 2026 challenge. Our method achieves a mean 5-fold cross-validation Dice of 0.648 at 500 epochs, a +0.018 improvement over the MedNeXt-L backbone at a matched training budget (0.630)

0.31

AsymFeX: A Symmetry-Driven Framework for Ischemic Stroke Segmentation Across Imaging Modalities and Stroke Stages

eess.IV cs.CV ·2026-08-20 ·Maunil Shah, Vaanathi Sundaresan
code/data similarity 0.69
Abstract

Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning. Non-contrast CT (NCCT), the first-line imaging modality for diagnosing ischemic infarcts, exhibits subtle infarct contrast, making manual delineation slow and labor-intensive. Motivated by this, and by the clinical practice of comparing brain hemispheres to localize infarcts, we propose a two-stage, nnU-Net-compatible 3D segmentation method. The first stage corrects head tilt to align each scan to its true anatomical mid-sagittal plane; the second applies a novel Asymmetric Feature Extraction (AsymFeX) module, comparing each voxel to its true contralateral counterpart within a local 3 x 3 x 3 neighborhood via cross-hemispheric attention, feature disparity estimation, and dual-scale gating to capture both large and small infarcts. On AISD, our method achieves 0.6796 Dice, 23.53 mm HD95, and 7.69 mL AVD, significantly outperforming existing state-of-the-art methods, with clinically relevant volumetric analysis at the 70 mL thrombolysis-eligibility threshold. Proof-of-concept evaluation on ATLAS v2.1 and ISLES'24 demonstrates that the same symmetry-driven design generalizes across imaging modalities and stroke time points without architectural changes, further supported by an uncertainty analysis assessing reliability under clinical deployment. Code is publicly available at https://github.com/biomedia-lab/AIS-detection.

0.23

Combining General and Domain-Specific Pretext Tasks for Brain MR Image Segmentation

cs.CV cs.AI ·2026-09-25 ·Tasneem Nasser, Susanne Schmid, Roberto Souza, Naser El-Sheimy
code/data similarity 0.69
Abstract · 7 figures, 5 tables

A key challenge in medical image analysis is the scarcity of large annotated datasets for specific populations and diseases. As deep learning models rely heavily on labeled data, effective transfer learning strategies are needed to reduce the dependence on manual annotations. Self-supervised learning has emerged as a promising approach for developing foundation models by enabling the learning of transferable feature representations from large-scale unlabeled medical imaging datasets. In this study, we investigate voxel-level brain age prediction as a domain-specific self-supervised pretext task and compare it with image inpainting, a widely used non-domain-specific alternative. We further propose a multitask self-supervised pretraining framework that jointly optimizes both objectives to learn complementary neuroimaging representations. The pretrained models are evaluated on three downstream magnetic resonance image segmentation tasks: multiple sclerosis lesion segmentation, ischemic stroke lesion segmentation, and cortical brain structure segmentation. Overall, the proposed multitask pretraining framework consistently outperformed the single-task pretrained models and training from scratch across most experimental settings, demonstrating the benefit of combining domain-specific and general self-supervised learning pretext tasks for the development of generalizable neuroimaging foundation models.\ Code Availability: The source code used in this study is publicly available at https://github.com/TasneemN/Combining-General-and-Domain-Specific-Pretext-Tasks-for-Brain-MR-Image-Segmentation/

0.30

Acute Stroke Classification Using Asymmetric Data Standardization and Orthogonal-Focal Loss Optimized CNN-ViT Cross-Attention Fusion: A Multicenter External Validation Study

eess.IV cs.AI ·2026-10-25 ·Tansel Uyar
code/data similarity 0.68
Abstract · All research data has been uploaded to Zenodo (DOI: 10.5281/zenodo.22132268). The data presented in this study are available on request from…

Background/Objectives: Rapid differentiation of ischemic and hemorrhagic stroke subtypes is vital for acute management. Although current deep learning models achieve high single-dataset accuracy, they suffer from "shortcut learning" and domain shift in external validation. This study proposes a hierarchical computer-aided diagnostic (CAD) system mimicking emergency triage. Methods: We introduce a 3-channel Radiology-Focused Preprocessing pipeline that feeds radiological Hounsfield Unit (HU) windows into Convolutional Neural Network (CNN) and Vision Transformer (ViT) backbones via asymmetric formats (.mat and .png). The architecture utilizes a novel joint cross-attention fusion network optimized by an Integrated Orthogonal-Focal Loss. Results: Our system achieved a 95.48% F1-score on the internal stroke dataset. However, multi-center external validation (AISD, BHSD, PhysioNet) using a Mask Anchor filter revealed a drop to the 58-62% range, exposing the "internal validation illusion" caused by hardware noise. Critically, models exhibited high precision (77%) but low sensitivity (57%) for ischemic stroke, proving prone to hemorrhage overdiagnosis. Multi-seed variance analysis demonstrated that the DenseNet201+ViT backbone yielded the lowest deviation (0.59) and highest stability, making it the most reliable architecture for real-world clinical integration. Conclusions: To overcome diagnostic challenges, future research must focus on multimodal architectures that combine 3D volumetric extraction with clinical data.

0.33

NeuroTS-Net: Multi-Class Semantic Segmentation of Pediatric Brain Tumors in Multi-Modal MRI

cs.CV cs.LG ·2026-09-15 ·Darius Peteleaza, Razvan-Gabriel Dumitru, Bogdan Neamtu, Arpad Gellert, Mariana Sandu +1 more
publishedcode/data similarity 0.68
Abstract · Accepted at the 2026 International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI) - BraTS Cluster of Chal…

Pediatric brain tumors are a leading cause of cancer-related mortality in children, and their small, rare, and often low-contrast subregions make accurate manual delineation challenging. Reliable automated segmentation is therefore needed to support diagnosis, treatment planning, and response assessment. Accordingly, we introduce NeuroTS-Net, a three-dimensional encoder-decoder convolutional neural network architecture for multi-class semantic segmentation that incorporates a dual-scale raw-detail stream, adaptive low-resolution context selection, and detail-preserving multipath downsampling. These components preserve fine intensity and boundary information while efficiently modeling broader tumor context. NeuroTS-Net was trained on the BraTS 2026 pediatric dataset without external data or pretrained weights and evaluated against nnU-Net and MedNeXt under the same experimental protocol. NeuroTS-Net outperformed the baseline methods, achieving whole-tumor and tumor-core Dice scores of 0.938 and 0.937 on the internal validation set and 0.927 and 0.926 on the official challenge validation set. The code is open-sourced at: https://github.com/maenstru56/NeuroTS.

0.37

Anatomical Grounding and Leakage-Aware Multimodal Contrastive Learning for Alzheimer's Disease Classification from Structural MRI

cs.CV cs.AI ·2026-09-14 ·Paul-Gabriel Nicolae, Irina Georgiana Mocanu
theory similarity 0.67
Abstract · 13 pages, 4 figures

Deep networks trained on structural MRI for Alzheimer's disease (AD) staging often reach reasonable accuracy while attending to anatomically irrelevant regions, and multimodal models that add clinical tables frequently rely on variables that were used to assign the diagnostic label in the first place. We study both issues with a deliberately lightweight slice-based encoder (ResNet18 with a one-layer Transformer over slices) on 1,075 baseline T1-weighted scans from ADNI-1. First, we use FastSurfer segmentations as an anatomical reference: YOLOv8 models trained on segmentation-derived labels localize Alzheimer-relevant structures with mAP_50 above 0.96, and a Grad-CAM comparison shows that the image-only classifier frequently attends to the skull, orbits and background. Second, we adapt a CLIP-style image - tabular contrastive framework and organize ADNIMERGE variables along a label-leakage spectrum. Fusion with cognitive scores yields 87.3% three-way accuracy, which we treat as a leakage-driven upper bound rather than an imaging result; fusion with regional volumes yields 73.0%. We observe that the choice of contrastive target changes what the image encoder learns: on MCI vs. CN, the image-only head reaches 52.4% when the encoder is aligned to cognitive scores and 73.8\% when aligned to volumes, although no tabular input is used at inference. Third, restricting the input to a per-subject crop of the medial temporal lobe raises image-only three-way accuracy from 58.7% to 65.1%. All results come from single runs on a small balanced test set, and we report confidence intervals and the protocol differences that prevent direct comparison with published numbers.

0.16