CS Paper Radar

Under-Mattress Temporal Sensing for Next-Day Agitation Risk Scoring in Dementia Wards

Zhen Liu, Marta Bono, Robbe Decloedt, Ajda Flisar, Maarten Van Den Bossche, Maarten De Vos

cs.AI cs.LG ·submitted 2026-08-28 10:14 UTC · v1
benchmark

Abstract

Agitation fluctuates over short time horizons in people living with dementia, yet continuous physiological information for anticipating next-day risk is limited. We assessed whether contactless under-mattress signals from the preceding night inform next-day agitation risk and whether preserving minute-level temporal structure improves performance over conventional nightly summaries. We analyzed 423 patient-nights from 65 subjects in a specialized hospital dementia unit using two under-mattress sensing systems. A unified four-paradigm benchmark compared nightly handcrafted summaries, three-period handcrafted features, full-night sequence modeling, and sliding-window multiple-instance learning. Source-specific preprocessing and five-fold patient-grouped cross-validation were used, with performance estimated from pooled out-of-fold predictions. Evaluation included discrimination, calibration, fixed-threshold metrics, and a comparison of period-signal attribution patterns across two temporal models. Full-night sequence modeling achieved the highest discrimination (AUROC, 0.692; AUPRC, 0.849) and balanced accuracy (0.658). Both minute-level pipelines had higher AUROC than nightly summaries, but differences from three-period handcrafted features were uncertain. Cross-model attribution prioritized activity, heart rate, and respiratory rate during the core overnight period. Calibration remained limited. The preceding night's signals supported modest next-day risk discrimination, with minute-level temporal modeling outperforming nightly summaries. Prospective calibration and external validation are needed before use in individual care decisions. This patient-grouped benchmark identifies contactless overnight sensing as a promising biomedical engineering direction for agitation-risk research in hospitalized dementia cohorts.

Closest papers

Nearest neighbours by meaning across the whole index.

Global Time-Aware Conditioning (GTC): A Mechanism for Time-Aware Pediatric Sleep Representation Learning

cs.LG ·2026-10-19 ·Saurav Raj Pandey, Harlin Lee
similarity 0.62
Abstract

Sleep physiology evolves throughout the night, with changes in sleep cycles, respiratory stability, and cardiovascular dynamics. However, self-supervised learning (SSL) methods for sleep typically process short, fixed-duration windows without explicitly modeling where each window occurs within the full sleep session. We introduce Global Time-Aware Conditioning (GTC), a mechanism that complements local positional encodings by conditioning latent representations on the global time-of-sleep of each input window. We integrate GTC into three representative SSL frameworks and evaluate them on five clinically relevant tasks with extreme class imbalance across two independent pediatric cohorts. GTC generally improves F1 and AUPRC across architectures and tasks, with gains persisting under cross-cohort transfer, highlighting the value of global temporal context for sleep representation learning.

0.24

Leveraging a Foundation Model for the EEG-Based Diagnosis of Alzheimer's Disease

cs.LG q-bio.NC ·2026-08-27 ·Maggie Lin, Chung-Lin Hou, Tzyy-Ping Jung
published similarity 0.59
Abstract · 7 pages, 9 figures, 1 table. Accepted and presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biol…

Biological heterogeneity in Alzheimer's Disease (AD) poses a critical diagnostic challenge, particularly for traditional linear methods that fail to capture non-linear neural dynamics. To address this, we propose a diagnostic framework utilizing the Large Brain Model (LaBraM), pretrained on over 2,500 hours of EEG data. By integrating these high-dimensional latent embeddings with a non-linear Random Forest classifier, our approach effectively isolates robust disease markers. Under a rigorous subject-independent 5-fold cross-validation protocol, the method achieves an ROC-AUC of 89.36% +/- 3.49%, PR AUC of 81.45% +/- 4.43%, and Balanced Accuracy of 82.44% +/- 4.34% in distinguishing dementia patients from healthy controls. Notably, this performance uses only 8-second EEG segments, surpassing traditional spectral baselines, including band-power and parameterized oscillatory features (FOOOF). Post-hoc occlusion analysis confirms the model captures clinically validated biomarkers, specifically occipital-frontal Alpha and Theta rhythm degradation. Additional neurophysiological alignment analysis demonstrated that higher LaBraM-predicted dementia probability significantly correlated with worse cognitive performance, greater clinical severity, increased theta and alpha relative power, and higher aperiodic exponent. These findings demonstrate that deep latent representations extract clinically relevant signatures from noisy signals, enabling precise, rapid, and data-efficient diagnosis.

0.30

Towards wearable-scale, transition-aware sleep staging for clinical populations

cs.HC cs.AI ·2026-11-16 ·Suvadeep Maiti, Keya Sinha, Raju S. Bapi
similarity 0.59
Abstract

Automatic sleep staging models are predominantly developed on healthy sleepers and generalize poorly to clinical populations with fragmented sleep. Across three cohorts (patients with stroke, isolated REM sleep behaviour disorder, and other sleep disorders), we observe 2-3x more awakenings per hour, nearly twice as much N1, and less REM sleep than in healthy sleepers. We propose a label-efficient teacher-student framework for wearable-scale sleep staging. SleepGPT (136M parameters), adapted using labels from 25% of training patients, supervises a causal CNN-GRU (31k parameters; 122 KB) that stages EEG, EOG, or both in real time. We introduce Gcv-TAD, a new black-box transition-aware distillation loss. It emphasizes uncommon stage transitions while discounting those that vary across patients, using a prior estimated from labelled patients. In patient-wise 10-fold cross-validation, Gcv-TAD improves per-patient macro F1 over supervised training on the same labels by +3.2 to +7.6 points on average. Gains are largest on N1, and performance approaches full-label training.

0.11

SemPSG: A Semantic Channel-Aware Foundation Model for Polysomnography Analysis

cs.LG ·2026-09-29 ·Junyu Chen, Chenxi Liu, Shiqin Tang, Hao Miao, Wanyun Ling +3 more
similarity 0.58
Abstract

Polysomnography (PSG) integrates multiple physiological signals to provide a comprehensive characterization of human sleep, yet its heterogeneous channel configurations across centers pose substantial challenges for transferable representation learning. Existing foundation models mainly focus on physiological modeling or temporal learning, while channel identity is often treated as a fixed structural index, overlooking the physiological semantics encoded by signal modality and reference configuration. To this end, we propose SemPSG, a Semantic channel-aware foundation model for heterogeneous PSG analysis. SemPSG explicitly represents the physiological semantics of channel identity and incorporates them into both signal representation learning and channel aggregation, enabling flexible modeling across diverse data configurations. Specifically, a semantic-conditioned time-series encoder captures signal-specific temporal dynamics and cross-signal interactions, while a multi-view image encoder extracts complementary time-frequency and morphological patterns from the same physiological recordings. We evaluate SemPSG on sleep and health-related tasks, including sleep staging, sleep-disorder breathing analysis, disease prediction, cognition and emotion recognition, and demographic estimation. Extensive experiments demonstrate consistent improvements over both general-purpose time series foundation models and PSG-specific foundation models, together with generalization across heterogeneous datasets across diverse channel configurations.

0.07

Duration-Aware World Models for Sleep Staging with Dwell-Time Constraints

cs.NE q-bio.QM ·2026-10-14 ·Junhui Gao
similarity 0.58
Abstract · 16 pages, 7 figures

Closed-loop neuromodulation requires sleep staging that respects stage-specific minimum dwells: stimulation policies switch by sleep stage, and a policy change is permitted only after the current stage has persisted for its minimum duration. Discriminative classifiers fragment stage trajectories---for example, a 30 s Wake segment inside a 10 min N2 run---and even hidden semi-Markov smoothing leaves 11.3% of segments below the minimum dwell threshold. This paper presents a world model in which a recurrent state-space model (RSSM) learns dwell structure endogenously from EEG, via duration-aware latent sampling, a survival-curve dwell prior, and transition-matrix calibration, and a trajectory-level hard-constraint layer guarantees the minimum dwell at decoding. On SHHS-1 (200 subjects, 160/20/20, three repeated splits), the model reaches a test accuracy of 0.690 +/- 0.053 (95% CI over 3 folds) versus 0.641 +/- 0.042 for an identically split discriminative baseline, with macro-F1 +17.5 pp and better accuracy on all three folds. On Sleep-EDF the constraint layer cuts below-threshold segments from 71.8% to 0.1% with no accuracy loss (0.734 to 0.737), and an online locked scheduler reduces RL policy switches by 87% per night while keeping every policy run at least 90 s. To the best of the author's knowledge, this is the first system to couple learned dwell statistics with a decoding-time hard guarantee. Code and pretrained weights will be released.

0.39

Foundation models for movement data: Are they ready for prime-time?

eess.SP cs.LG ·2026-08-13 ·Alexander Bräuer, Benjamin Cauchi, Nils Strodthoff
code/data similarity 0.58
Abstract · 14 pages, 6 figures, 8 tables, code is available at https://github.com/AI4HealthUOL/movement-fm-benchmarking

Foundation models (FMs) trained on large-scale accelerometer data have been proposed as general-purpose feature extractors for health monitoring, but systematic evidence of their advantages is lacking. We present the first comprehensive evaluation of four open-source accelerometer FMs against supervised baselines covering 19 tasks across the domains of activity recognition including activities of daily living, clinical monitoring, and physiological inference. We find task-dependent performance results: supervised models remain competitive with FMs on human action recognition (HAR), with no consistent advantage for either, while selected FMs lead on fall and stress detection and are the most robust to sensor-placement variation. As frozen feature extractors, FMs are strongest for demographic inference, whereas sleep staging performance remains near chance level for all models. The internal FM representations show strong similarity across layers, highlighting potential for future FM improvements. Linear and frozen probing reveals that UniMTS provides the strongest representations and is the only FM that surpasses the supervised baselines without finetuning. Concept discovery analysis shows all models capture high-intensity activities clearly but struggle with sedentary, complex or ambiguous activities. We provide scenario-based deployment recommendations. Furthermore, we identify FM-derived activity profile inference-moving beyond fixed category classification-as a promising research direction.

0.30

Hybrid Ensemble Learning for EEG-Based Epileptic Seizure Forecasting

cs.LG ·2026-09-26 ·Mason Dana, Khandaker Mamun Ahmed
publishedcode/data similarity 0.58
Abstract · Accepted at the 2026 IEEE Cyber Awareness Research Symposium (CARS 2026)

Epileptic seizure forecasting aims to provide actionable warnings before seizure onset, yet patient-independent generalization and false-alarm control remain major challenges. We propose a calibrated hybrid ensemble for EEG-based seizure forecasting that combines five deep learning models and three classical machine learning models through a logistic regression stacking meta-learner. The proposed pipeline integrates signal preprocessing, handcrafted feature extraction, class-imbalance handling, probability calibration, and clinically motivated post-processing. We evaluate the framework on CHB-MIT using strict Leave-One-Patient-Out (LOPO) cross-validation, with threshold and post-processing parameters selected only on held-out meta data. On the filtered cohort, excluding patients with anomalous preictal rates below 1\% or above 15\%, the model achieves 74.2\% seizure-level sensitivity at 1.24 false alarms per hour, with an average warning time of 16.9 minutes. A test-tuned oracle constrained to the target false-alarm budget achieves 60.9\% sensitivity at 0.951 false alarms per hour, highlighting the importance of reporting sensitivity together with realized false-alarm rates. Our code is available at: https://github.com/DanaMason/IEEE-CARS-Hybrid-Ensemble-Learning-for-EEG-Based-Epileptic-Seizure-Forecasting

0.36

ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health

eess.SP cs.LG ·2026-10-16 ·Donglin Xie, Qingshuo Zhao, Songchi Zhou, Haoyu Wang, Jingyu Wang +3 more
similarity 0.57
Abstract

Conventional sleep staging provides a coarse-grained representation that obscures within-stage depth variation. We developed ECG-SDI, a single-lead electrocardiography (ECG) framework for continuous sleep-depth profiling and digital biomarker extraction. Using 12,392 overnight polysomnographic recordings, we trained and validated a two-stage deep learning model supervised by conventional sleep-stage labels. Correlations with ordered stages excluding rapid eye movement (REM) sleep were 0.828 in the pooled internal test set and 0.848 in the external Cleveland Family Study; corresponding REM classification AUROCs were 0.954 and 0.977. Overnight trajectories captured within-stage variation. Biomarker-based phenotyping identified a disturbed subtype associated with poorer subjective sleep quality and higher all-cause mortality in the Sleep Heart Health Study (adjusted hazard ratio, 1.20; 95% CI, 1.05-1.38). Among 507 participants with paired recordings before and after continuous positive airway pressure (CPAP), normalized sleep-depth area increased by 6.1% and shallow-sleep burden below 0.3 decreased by 16.0%. Exploratory analyses linked reductions in approximate entropy and depth variability to reduced oxygen desaturation and increased sleep efficiency, respectively (Spearman rho = 0.24 and 0.12); both associations remained positive after covariate adjustment. Mean ECG-SDI within N2 increased by 0.017 (95% CI, 0.004-0.030). A wearable proof-of-concept illustrated the acquisition-to-report workflow. These findings support ECG-based sleep phenotyping and further evaluation of CPAP response monitoring at home.

0.13