CS Paper Radar

Artificial Intelligence for Energy Optimization in Data Centers

Mohammed Basharath Ullah, Summaiya Unnisa Begum, Mohammed Nadeem Ullah

cs.AI cs.LG ·submitted 2026-09-03 11:51 UTC · v1
code/data

Abstract

Data centers are increasingly optimized by artificial intelligence and, at the same time, increasingly loaded by it. The literature treats these as two unrelated problems: control studies model workload as an exogenous arrival process, while sustainability studies model infrastructure as a fixed multiplier. We screen roughly 194 papers retrieved through a documented protocol, code 63 of them, and report what the coding shows. Of 28 primary control-oriented studies, 18 are validated in simulation alone and 5 reach physical hardware or a production facility; none account for water withdrawal, and none account for embodied carbon. Reported savings intervals across four technique families overlap almost completely, which means the field cannot presently rank its own methods. Ten recurring gaps are scored for consequence and tractability, and we set out CLEAR-DC, a framework coupling a control-policy branch to a workload-demand branch through an explicit elasticity term, reads out net rather than direct benefit, and emits a schema-conformant record covering energy, carbon, water, embodied share and validation venue. The framework is an architectural and methodological proposal, not a trained system; the contribution we defend empirically is the corpus analysis and the reporting schema derived from it. Coding sheet, derived statistics and all result artifacts: https://github.com/Kimalice/AI-for-Energy-Optimization-in-Data-Centers-Closing-the-Optimizer-Load-Loop

Comment
11 pages, 6 figures, 7 tables

Closest papers

Nearest neighbours by meaning across the whole index.

GreenDirector: carbon- and water-aware workload placement for sustainable computing

cs.DC ·2026-09-11 ·Jaime Iglesias Blanco, Ignacio Heredia, María Castrillo, Andrei Tsaregorodtsev, Mazen Ezzeddine +1 more
similarity 0.72
Abstract

The rapid growth of data center electricity demand, accelerated by AI, makes carbon-only accounting an incomplete measure of computing's environmental impact: low-carbon electricity mixes are often water-intensive, and the resulting harm depends on local, seasonal scarcity rather than on the volume of water consumed. We propose the Environmental Score (ES), a unified, dimensionless index in $[0, 100]$ that jointly captures the carbon footprint and the spatial-temporal, scarcity-weighted water impact of the electricity a workload consumes. It combines real-time, cross-border electricity flow tracing with monthly AWARE2.0 water-scarcity characterization factors, weighting global greenhouse-gas emissions together with the local, seasonal severity of water stress. Building on it, we define the Green Score (GS), a scheduling metric proportional to the useful computational work delivered per unit of real environmental impact, which also accounts for data center power and hardware efficiency. We add both metrics as a green-affinity feature to the GreenDirector schedulers of two production federated infrastructures, the AI4EOSC scientific cloud and the DIRAC workload management system. In AI4EOSC, a cluster-filling experiment over four pan-European providers shows that greener sites are filled first without degrading scheduling latency or end-user experience. In DIRAC, a trace-driven simulation of 133,631 jobs and a preliminary production deployment for the KM3NeT community reduce carbon emissions and improve carbon efficiency by about 40\%, while making the carbon-water trade-off explicit when the lowest-carbon site also carries higher water stress. The results show that hydrological stress can be dynamically weighted into workload placement in live, multi-tenant systems

0.19

Data center cooling choices shift water impacts across the grid: An integrated water-energy model for sustainable data center development

eess.SY cs.CYcs.DC ·2026-09-21 ·Garrett Alston, Nancy Love, Rabab Haider
code/data similarity 0.68
Abstract · 12 pages; 8 figures; 6 tables; appendix

Data centers are being developed at an unprecedented pace, yet their energy and water impacts, and the spatial and temporal distribution of these impacts, remain poorly characterized. Data centers consume water for cooling (direct) and through electricity generation (indirect). Decisions on siting and cooling technology result in water-energy trade-offs that extend impacts beyond the facility's location. Existing assessment frameworks rely on facility efficiency metrics and average grid water intensity factors, suppressing the temporal impacts of data center load and generation availability. They also attribute indirect consumption to the facility's location rather than to the generators (and corresponding hydrologic regions) that respond to the added load, misattributing spatial impacts. To close this gap, we develop a computational model of the data center-energy-water nexus that links facility cooling and electricity demand with hourly economic dispatch, generator-level water consumption, and monthly subbasin depletion. Built on open-source data, the model resolves where and when water is consumed, and where this consumption compounds existing water risk or creates new risk. Using the model, we study different cooling configurations and proposed developments in the state of Michigan. Air-cooled data centers halve total water consumption relative to evaporative cooling, but increase electricity demand and raise indirect water consumption by one-third, shifting the water footprint from the facility to generators. Mapping these changes to subbasins reveals depletion increases beyond the data center sites, in regions that facility-level reporting may overlook. These results show that data center water and energy impacts cannot be assessed in isolation, motivating the need for integrated modeling to inform siting, design, and reporting practices.

0.22

Speed-to-Power Dominates Energy Costs for AI Data Centers: Technoeconomic Analysis of Powering AI in the Continental United States

cs.AI eess.SY ·2026-11-12 ·Alex C. Newkirk, Daniel L. Gerber, Erica R. H. Fuchs, Alex Hubbard, M. Granger Morgan +3 more
code/datahot direction similarity 0.68
Abstract · 80 pages incl. SI

The rapid growth of artificial intelligence is driving demand for new data centers at large scale and on short deployment timelines. To power them, firms connect to the commercial grid or contract generation directly, but interconnection and gas-turbine delays now incentivize on-site generation. We compare grid-connected and off-grid data center energy infrastructure (AC- and DC-coupled solar-plus-storage, islanded natural gas, and grid interconnection) across the continental U.S. Using an open-source technoeconomic framework built on empirically calibrated AI training loads, climate-driven cooling, stage-by-stage power conversion, and physics-based battery degradation, we model designs providing equivalent energy services. Our central contribution is a speed-adjusted cost of energy that values the compute unlocked by faster construction, making options with different deployment timelines directly comparable on one physically consistent basis. We find DC coupling reduces lifetime energy costs by 18% ($0.09/ kWh) on average versus AC counterparts by eliminating inverters and improving efficiency. Though rarely cheapest on unadjusted energy cost, DC-coupled microgrids' faster deployment makes them the lowest-cost modeled option in 85% of U.S. locations once foregone compute is valued, or 55% under accelerated natural gas timelines. For AI infrastructure, deployment speed rather than unit energy cost determines the economically preferred path to power.

0.31

Beyond the Last Truffula Tree: SustainAI - A Water-Aware, Closed-Loop Framework for Environmentally Accountable AI

cs.CY cs.AIcs.DCcs.HC ·2026-09-25 ·Farnaz Farid, Tashfia Towkee, Sania Nasreen, Sami bin Azad
similarity 0.68
Abstract · 10 pages, 2 Figures

As artificial intelligence (AI) becomes embedded in everyday life, its environmental footprint, particularly water consumption remains largely invisible. While energy and carbon impacts are widely recognized, the substantial freshwater demands of data center cooling and electricity generation receive little attention. To address this gap, we introduce SustainAI, a water-aware, closed-loop framework incorporating environmental accountability into AI deployment. SustainAI integrates real-time water metering, a hallucination-aware penalty model, and a water-aware routing algorithm that accounts for regional water stress. Evaluated via Small Language Models (SLMs) extracting health misinformation, results reveal an 11-fold variation in water footprint across geographically distributed data centers (0.0477 mL to 0.5360 mL per inference). Across 1,335 inference runs, the system consumed approximately 399 mL of water but produced only 240 correct outputs, demonstrating that substantial resources are spent on inaccurate responses. Crucially, SustainAI extends beyond technical optimization through a Care by Design lens, framing AI sustainability around relational ethics, regional equity, and ecological stewardship. By combining water monitoring, adaptive accountability, and Care by Design principles, SustainAI provides a practical foundation for integrating ethical care and environmental responsibility into AI infrastructure design and lifecycle management.

0.28

Water-Energy-Data nexus reveals sustainability gaps and priorities for AI infrastructure

cs.CY ·2026-10-16 ·Jincheng Huang, Guoan Xiao, Xin Lan, Caichun Yin, Zhimeng Jiang +2 more
similarity 0.67
Abstract

The rapid growth of artificial intelligence (AI) depends on interconnected water, energy, and data systems spanning infrastructure life cycles and diverse geographies, with the potential to intensify water and energy insecurity, exacerbate social inequities and lead to cascading sustainability issues globally. Yet assessments commonly examine them separately, limiting our understanding of where resource pressures arise, how they are transferred across space, and who bears their consequences. To address these challenges, we established a water-energy-data (WED) nexus framework that captures the spatial and life-cycle dependencies of AI infrastructure, and use large language models to synthesize 12,825 water- or energy-related studies across four resource-intensive AI infrastructure activities: mineral extraction, semiconductor manufacturing, data center operation and electronic-waste processing. The evidence map identifies a mismatch between the interconnected activities supporting AI infrastructure and boundaries used to assess them. Researchers assess operational energy more than water use and other indirect demands, while interactions across locations and life-cycle activities remain understudied. These gaps obscure how resource demands shift among infrastructure nodes and regions, and how data-enabled benefits compare with their underlying costs. The WED nexus provides a foundation for integrated assessment of spatially metacoupled systems, while the evidence map can inform priorities for managing the sustainability implications of the AI boom.

0.10

Environmental Impact of Generative and Agentic AI: An in-Depth Analysis and Green Solutions

cs.CY cs.AI ·2026-09-26 ·Abderaouf Bahi, Amel Ourici, Ibtissem Gasmi
similarity 0.66
Abstract

The proliferation of generative and agentic artificial intelligence (AI) systems has introduced computational demands whose environmental consequences are substantial yet underexamined. This paper examines the environmental footprint of modern AI systems across energy consumption, carbon emissions, water usage, and electronic waste over the full lifecycle of large language models, multimodal foundation models, and agentic workflows, from hardware fabrication and training through fine-tuning and inference to end-of-life disposal. This work provides a conceptual analysis, utilizing order-of-magnitude estimations based on published data, without conducting original physical measurements. We contribute a lifecycle taxonomy that crosses lifecycle phases with five impact dimensions and emission scopes; a Sustainability Assessment Framework for AI Systems (SAFIA) comprising nine indicators; a comparative analysis of traditional, generative, and agentic AI; seven open challenges; policy recommendations for regulators, cloud providers, hardware manufacturers, and AI developers; and a research roadmap to 2035. The analysis indicates that inference can rival or exceed training energy over a deployment lifetime, that agentic workflows can multiply the energy of equivalent single-pass inference by one to several orders of magnitude depending on the number of model and tool calls, that indirect water use and embodied carbon are systematically underreported, and that measurement tools, disclosure practices, and regulation have not kept pace with agentic deployment. These findings call for agent-aware energy measurement, lifecycle-based carbon and water accounting, and mandatory disclosure for large-scale AI training and deployment.

0.19

CATS: A Carbon-Aware Task Simulator for Reducing AI Data Center Emissions

cs.DC ·2026-09-13 ·Dayuan Chen, Ziliang Zong
similarity 0.66
Abstract · 14 pages, 12 figures, 8 tables

The rapid rise of generative AI is accelerating cloud data center expansion, with electricity demand projected to double by 2026. Because carbon-intensity varies by more than 5.5x across grids and times of day, where and when inference tasks execute significantly affects operational emissions. We address this issue with three aspects in this paper. First, we compile a global alignment dataset unifying 140 operational and planned cloud regions across 8 major providers with five-minute carbon-intensity traces for 145 grid regions from 2022 to 2024, revealing that 50% of current sites lie in medium-to-high carbon-intensity grids, indicating a siting-carbon mismatch and unrealized carbon reduction potential. Second, we develop CATS (Carbon-Aware Task Simulator), a flexible trace-driven framework that profiles six AI inference tasks across multiple GPU types, synthesizes realistic diurnal curve, geographical and task mixes, and SLA constraints, and evaluates spatial and temporal schedulers against two baselines while reporting comprehensive metrics including carbon emissions, energy consumption, runtime, queue delay, and hardware utilization. Third, we quantify achievable CO2 savings under realistic constraints: in a 24-hour trace with 600,000 tasks at fleet utilization of 0.37, spatial shifting reduces CO2 by 38.4% versus speed-first baseline, while temporal shifting yields 16% savings with bounded SLA violations at 3.27%. These results advocate locating future data centers in low carbon-intensity grids and demonstrate that carbon-aware scheduling on today's fleets can achieve substantial operational emissions reduction.

0.18

Investigating the Impact of CI-Source Sensitivity in Carbon-Aware Resource Management Systems

cs.DC ·2026-11-16 ·Gonçalo Ferreira, Jaime Iglesias Blanco, María Castrillo, Álvaro López García, Li Wu +1 more
similarity 0.66
Abstract · 9 pages, 6 figures, 6 tables

The sustainable growth of data centres increasingly depends on Resource-Management Systems (RMSs) that aim to reduce carbon emissions of computing workloads without degrading performance. This need is intensified by the rise of Artificial Intelligence (AI) workloads, which demand exponentially growing amounts of compute and energy across geographically distributed infrastructure. Recent carbon-aware RMSs exploit temporal and spatial variation in grid Carbon Intensity (CI) to shift workloads towards lower-carbon periods or locations. In practice, CI estimates and forecasts can be inaccurate and uncertain, and CI providers' methods differ substantially. Such discrepancies may have a significant impact on RMS placement decision-making, raising concerns about the fragility of existing solutions. Thus, in this work, we ask how discrepancies between plausible CI estimates propagate into resource-management decisions and operational outcomes. To answer this question, we harmonise and characterise CI traces from Wattnet and ElectricityMaps across five Central European zones. We then propose our evaluation framework: External CI Signal Characterisation And Perturbation Evaluation (ESCAPE), which assesses provider switching and controlled CI perturbations in a reproduced placement setting. We implement our framework using CarbonEdge as a use case, and measure changes in placement decisions and operational outcomes, such as carbon proxy, energy use, and latency. Our results show that switching CI-source changes the dominant placement site in 43.50% cases, and alters reported operational outcomes. These changes occur despite high rank correlation and structured disagreement between CI-sources. This observed sensitivity to CI-source choice motivates robustness-aware carbon-aware placement, in which CI uncertainty should be explicitly accounted for in resource-allocation decisions.