CS Paper Radar

Ultrasound-Based Prediction of Cirrhosis Decompensation Using Large-Scale Computer Vision Models

Guangyi Zhang, Peiyun Ni, Eugene Cheah, Rajat Chandra, Peng Guo, Raymond T. Chung, Anthony E. Samir

eess.IV cs.AIcs.CV ·submitted 2026-09-03 18:25 UTC · v1
published

Abstract

Decompensation represents a critical transition in the course of cirrhosis, yet clinicians have limited non-invasive tools to reliably predict its onset. In this study, we propose a novel imaging-based approach that leverages large-scale computer vision models to analyze routine abdominal ultrasound images and extract predictive features beyond those captured by traditional laboratory-based risk scores. Ultrasound is widely available, low cost, and suitable for longitudinal surveillance, making it an attractive modality for scalable risk stratification and long-term follow-up. Our framework integrates automated ultrasound data processing with modern deep learning architectures to identify patients at high risk of decompensation prior to the occurrence of clinical deterioration. This non-invasive strategy offers a practical complement to existing clinical scoring systems and may enable earlier, more proactive management of patients with compensated cirrhosis.

Comment
6 pages, 2 figures. Accepted and presented at IEEE EMBC 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Development and Evaluation of Ultrasound Image Learning Pipelines for MASLD Risk Stratification

eess.IV cs.CV ·2026-09-03 ·Guangyi Zhang, Xiaohong Wang, Eugene Cheah, Peng Guo, Brian A. Telfer +2 more
published similarity 0.71
Abstract · 7 pages, 4 figures. Accepted and presented at IEEE EMBC 2026

Metabolic dysfunction-associated steatotic liver disease (MASLD) affects approximately 30% of the general population. Ultrasound-based imaging, including B-mode imaging and shear wave elastography (SWE), is widely used for noninvasive fibrosis assessment; however, the role of deep learning-based ultrasound image learning for MASLD risk stratification remains insufficiently characterized. In this study, we developed and evaluated ultrasound image learning pipelines using B-mode and SWE images for fibrosis staging and identification of patients with at-risk metabolic dysfunction-associated steatohepatitis (MASH). A total of 250 ultrasound examinations, one exam per subject, were included. Model performance was evaluated using 3-fold cross-validation with area under the receiver operating characteristic curve (AUROC). End-to-end SWE image learning achieved performance comparable to operator-guided SWE across fibrosis stages. Overall, SWE-based learning consistently outperformed B-mode image learning in fibrosis staging, with AUROC improvements from 0.64 (95%CI: [0.56, 0.72]) to 0.72 (95% CI: [0.65, 0.79]) for F>=2 (significant fibrosis, p=0.11), from 0.67 (95%CI: [0.58, 0.75]) to 0.78 (95% CI:[0.72, 0.85]) for F>=3 (advanced fibrosis, p=0.02), and from 0.69 (95%CI: [0.56, 0.82]) to 0.80 (95%CI: [0.72, 0.89]) for F4 (cirrhosis, p=0.10). These findings highlight the potential of SWE image learning for MASLD risk stratification.

0.35

CMCNet: Aligning Ultrasound Image Embeddings with Textual TI-RADS Representations for Fine-Grained Thyroid Classification

cs.CV cs.AI ·2026-08-14 ·Bingxin Yu, Xueli Wang, Jerry Zhou, Wenyan Wang, Li Wen +4 more
datasetcode/data similarity 0.68
Abstract

Ultrasound is the primary imaging modality for assessing thyroid nodules, and the ACR TI-RADS framework standardizes diagnosis through five ultrasound feature categories that are aggregated into five risk levels (TR1-TR5). Although widely adopted in clinical practice, most deep learning approaches focus on binary malignancy classification, while multi-class prediction and explicit utilization of feature-level supervision remain underexplored, largely due to limited annotated data. In this study, we introduce the STN dataset of 600 thyroid nodules with paired transverse and longitudinal ultrasound images, bounding box annotations, and complete labels for all five TI-RADS feature categories. Following the clinical decision process, we investigate how structured feature information can guide representation learning during training while requiring only images at inference. We demonstrate that text embeddings derived from standardized feature descriptions form a stable surrogate representation for TI-RADS risk levels. Based on this observation, we propose CMCNet, which aligns image embeddings to fixed textual embeddings via a Center-Margin Contrastive Loss that simultaneously promotes intra-class compactness and inter-class separation. Experimental results show that this embedding alignment strategy is more data-efficient and robust than direct multitask learning, and consistently outperforms InfoNCE, center loss, a strong multitask baseline, and a VQA-style multimodal model, particularly in imbalanced settings. The dataset is freely available at doi: 10.5281/zenodo.19125693 and the source code is available at: https://www.healthinformaticslab.org/supp/.

0.20

ProtoCAM: Interpretable Few-Shot Mask-Guided Prototypical Learning for Breast Lesion Classification in Ultrasound Imaging

cs.CV cs.AI ·2026-09-11 ·Ashkan Ebadi
similarity 0.65
Abstract · 11 pages, 3 figures

Breast ultrasound imaging plays an important role in the early detection and diagnosis of breast cancer, particularly for patients with dense breast tissue. However, developing reliable deep learning models for ultrasound analysis is challenging due to limited annotated medical data and the need for interpretable predictions. To address these challenges, this paper proposes ProtoCAM, an explainable few-shot learning framework for breast lesion classification that integrates mask-guided feature encoding, prototypical metric learning, and gradient-based visual explanations. The proposed approach leverages lesion masks to guide feature extraction and constructs class prototypes within an embedding space to enable robust classification under limited training samples. The framework was evaluated on the BUSI dataset using a stratified group k-fold cross-validation protocol to prevent patient-level data leakage. Experimental results demonstrate ProtoCAM's high performance in low-data scenarios. In a 3-way 5-shot setting, the proposed method achieves a macro F1-score of 0.910, representing a substantial improvement over standard supervised CNN models. Among the evaluated backbone networks, ResNet18 achieved the best performance, reaching a macro F1-score of 91.65% under a 15-shot configuration, providing interpretable insights into the classification decisions. These results highlight the potential of explainable few-shot learning frameworks for reliable computer-aided breast cancer diagnosis in data-scarce medical imaging environments.

0.10

AppendiGrade: An XAI-Enhanced Deep Learning Framework for Grading Appendicitis in Ultrasound with Gaussian Blur and Grad-CAM

cs.CV cs.LG ·2026-08-18 ·Fahad Ahammed, Omar Faruq Shikdar, Navid Zaman, Md Tahsin, Md. Nawab Yousuf Ali +1 more
similarity 0.64
Abstract

Appendicitis is one of the most common abdominal emergencies worldwide and requires prompt diagnosis and treatment to prevent life-threatening conditions. However, accurately differentiating complicated cases, such as perforation or abscess formation, from uncomplicated appendicitis remains a significant clinical challenge. Among other methods, ultrasound is a safer and more cost-efficient diagnostic technique because of the lack of radiation exposure. In this research, an advanced system capable of automatically detecting complicated appendicitis from ultrasound images was developed. A dataset consisting of 4679 ultrasound images with 5 classes, namely perforated, abscess, acute, appendicolith, and normal, was used for the proposed model training and testing. Four pretrained deep learning models, DenseNet201, InceptionV3, ConvNextTiny, and VGG19, have been employed for detecting and classifying complicated appendicitis. In the initial configuration, InceptionV3 achieved the second highest accuracy, with a value of 69.21%. Owing to suboptimal performance with raw images, further optimization techniques, including image preprocessing, hyperparameter tuning, model fine-tuning, and image sharpening, were applied. These enhancements significantly improved the model's performance, with an accuracy of 95.58% for InceptionV3. The model performance is then explained with gradient-weighted class activation mapping (Grad-CAM), which creates a heatmap of the regions responsible for the model's prediction of the infected areas. This could make crosschecking with experts much easier.

0.25

CirrGuide: A Deep Cascaded Framework for Liver Cirrhosis Segmentation and Severity Classification from T2-Weighted MRI

cs.CV ·2026-09-12 ·Muntaqim Ahmed Raju, Ruizhe Ma
published similarity 0.64
Abstract · 10 pages, 2 figures. Accepted at the 17th International Workshop on Machine Learning in Medical Imaging (MLMI 2026), held in conjunction wit…

We present CirrGuide, a deep cascaded framework for cirrhotic liver segmentation and severity classification. Cirrhosis causes progressive structural changes in the liver and can lead to serious clinical complications, making severity assessment important for disease monitoring and treatment planning. However, severity classification is challenging because imaging patterns are often subtle, spatially variable, and similar across adjacent stages. CirrGuide addresses this by explicitly linking localization with classification. A ResNet50 encoder with an Attention U-Net decoder first predicts a soft cirrhotic liver mask, which is then used as an anatomical prior in a ResNet50-based classification branch. This branch combines global multi-scale features with mask-guided attention-pooled regional features to classify Mild, Moderate, and Severe cirrhosis. On the official CirrMRI600+ T2-weighted (T2W) 2D split, CirrGuide achieves 89.83% Dice and 84.14% mIoU for segmentation, 69.58% accuracy and 61.55% macro F1-score for severity classification. Compared with segmentation-only, classification-only, and multi-task baselines, CirrGuide improves both localization and severity classification, demonstrating the benefit of using predicted cirrhotic liver masks as anatomical priors for cirrhosis analysis.

0.69

Deep Learning-based Intelligent Diagnosis of Congenital Uterine Anomalies in 3D Ultrasound

cs.CV ·2026-09-14 ·Yueyue Xu, Yuhao Huang, Jiaxiao Deng, Yuanji Zhang, Haoming Zhang +9 more
published similarity 0.64
Abstract · 22 pages, 7 figures, 4 tables

Objective: To develop an intelligent framework, termed CUA-Net, for the automated classification of congenital uterine anomalies (CUA) without requiring coronal plane reconstruction, and to evaluate its clinical applicability. Methods: CUA-Net was built on 3D ResNet-18, equipped with a dynamic data resampling strategy to mitigate the data imbalance issue and a hard sample mining technique to fully learn from the difficult cases by loss adjustment. We further proposed the self-supervised reconstruction to comprehensively explore the volumes and the online data augmentation to refine the wrong predictions and enhance the model's generalization. We compared the CUA-Net with different deep-learning methods and junior/senior sonographers in the testing set. The evaluation metrics included accuracy, precision, recall, F1-score, micro-AUC, and macro-AUC. Results: The proposed CUA-Net exhibited satisfactory performance in both internal and external test sets. In the internal cohort, the model achieved accuracy of 93.88%, precision of 87.01%, recall of 95.92%, F1-score of 88.09%, and micro-AUC of 0.9982 and macro-AUC of 0.9997. In the external set, it maintained good performance with accuracy of 91.52%, precision of 83.27%, recall of 88.63%, F1-score of 81.49%, micro-AUC of 0.9945 and macro-AUC of 0.9990. Our CUA-Net outperformed the junior sonographers across all performance indicators and achieved performance comparable to that of the senior sonographers across most metrics. Conclusion: The CUA-Net demonstrates favorable accuracy and generalizability in classifying common CUA categories, while showing preliminary potential for recognizing less prevalent anomalies. These capabilities may help optimize clinical workflows and support more standardized diagnosis.

0.37

VCRE-Fib: View-Conditioned Regional Evidence for Fine-Grained Ultrasound Grading of Schistosoma japonicum-Associated Liver Fibrosis

cs.CV cs.LG ·2026-09-26 ·Ziyang Xu, Shuli An, Hao Zhou, Haitian Zhong, Tingting Wu +3 more
code/data similarity 0.64
Abstract · 20 pages, 5 figures, including appendices. Submitted to ICLR 2027. Code: https://github.com/StatXzy7/vcre-fib

Accurate assessment of Schistosoma japonicum-associated liver fibrosis is essential for disease management and long-term follow-up in endemic regions. Ultrasound provides non-invasive imaging, but complex local echogenic patterns and anatomical structures make fine-grained grading challenging. Existing deep learning methods can predict fibrosis scores, yet directly incorporating acquisition views and regional cues into grading while retaining spatial information for inspection remains an open problem. Here we present VCRE-Fib, a view-conditioned regional evidence framework that integrates anatomical context, local information, and global image assessment for fine-grained ultrasound grading. The framework forms view-conditioned local grading evidence before spatial pooling, uses weak localization to guide its aggregation, and combines it with global predictions. Image-only inference jointly returns a fibrosis score, acquisition view, and candidate abnormal-region map. We developed and evaluated the method on a re-curated cohort of 108,709 ultrasound images from 6,373 patients across 35 centers. On a patient-disjoint test set of 4,107 images from 240 patients across four centers, VCRE-Fib reduced the prespecified composite grading risk by 7.115% relative to SFibAI trained and evaluated on the same data split. Image-level mean absolute error decreased from 0.391 to 0.378, alongside lower patient-max, patient-median, and center-balanced risks. The full model also achieved lower composite grading risk than variants that separately removed view conditioning or weak localization. These results support incorporating anatomical context and regional evidence into ultrasound grading while exposing spatial predictions for inspection alongside severity estimates.

0.52

DINO-Med: A Unified Patch-Based Adaptation Framework for Multi-Modal Medical Image Analysis Applied to Liver Fibrosis Staging

cs.CV ·2026-09-10 ·Boya Wang, Ruizhe Li, Chao Chen, Xin Chen
published similarity 0.64
Abstract · 12 pages, 2 figures. Accepted by AIiH

Adapting natural-image foundation models like DINOv3 to multi-modal medical imaging is challenging due to the significant domain gap between natural color images and multi-channel medical scans. We present a unified, patch-based framework that processes raw multimodal imaging through training-free registration, automated localization, and mask-filtered patch extraction. This architecture culminates in a hierarchical strategy that aggregates patch-level insights into subject-level diagnostics. Using liver fibrosis staging as a case study, we evaluate four patch-level feature representations: handcrafted Radiomics features, learned ResNet features, pre-trained foundation model SAM-Med2D features, and frozen DINOv3 features. To ensure a controlled comparison, all models utilize the same lightweight MLP head and are evaluated across both rigid and deformable registration settings. Our training protocol focuses on mild fibrosis (S1) and cirrhosis (S4) classes only, enabling a single classifier to address both substantial fibrosis detection and cirrhosis staging. Evaluated via 10 random train (90%)/ test (10%) splits on 360 subjects from the CARE 2025 Liver Track 4 cohort, our DINOv3-based framework significantly outperforms all baselines, achieving the best classification accuracy of 78.4% for S1 and 75.8% for S4.

0.43