CS Paper Radar

MultiAttenGastro: Multi-Dimensional Attention Augmentation for Gastrointestinal Endoscopy Classification

Sadhana Devarajan, Praveen Kumar Chandaliya, Dhruvin Jashvant Kumar Shah, Kishor Upla, Kiran Raja

cs.CV ·submitted 2026-09-04 12:28 UTC · v1
benchmark

Abstract

Automated gastrointestinal (GI) endoscopy classification requires models that generalize across diverse modalities and class distributions, often far from natural-image pretraining. We propose MultiAttenGastro, a plug-and-play attention framework with parallel 1-D channel, 2-D spatial, and 3-D contextual heads, and present the first systematic cross-dataset evaluation across eight CNN and transformer backbones on five public GI datasets (80 backbone--dataset runs). We find that attention effectiveness is not universal but tracks the representational gap between ImageNet features and the target distribution: MultiAttenGastro improves 6 of 8 backbones on Kvasir-Capsule (14-class WCE, large gap; best macro F1 98.33\%), is uniformly negative on the small-gap Kvasir-v2 benchmark (0/8), and shows mixed outcomes on datasets with intermediate gap. Five-seed ablation on the strongest case (Kvasir-Capsule, ConvNeXt-Tiny) shows this improvement is directionally consistent, but not statistically decisive (paired $t$: $p=0.47$; Wilcoxon: $p=0.63$), and that individual attention heads are not uniformly beneficial in isolation only their combination yields a positive mean effect. Centered Kernel Alignment (CKA) analysis links this pattern to representational redundancy: low inter-head CKA under large domain gaps coincides with the framework's only consistent gains, while high redundancy under small gaps coincides with its losses. We report these results, including the non-significant margins, as evidence for when and why multi-dimensional attention helps GI endoscopy classification, rather than as a claim that MultiAttenGastro is a strictly superior architectural choice.

Comment
17 Pages, 2 Figures, CVIP2026

Closest papers

Nearest neighbours by meaning across the whole index.

Rethinking Evaluation for Video Capsule Endoscopy: Validation Protocol, Source-Video Diversity, and Cross-Dataset Shift

cs.CV ·2026-11-09 ·Smriti Regmi, Debesh Jha
benchmark similarity 0.71
Abstract · 4 figures and 9 tables

Automated video capsule endoscopy (VCE) classification remains challenging due to severe class imbalance, limited source-video diversity, and variations in image appearance across datasets. Although deep learning models have demonstrated promising performance on established benchmarks, their reliability under different validation protocols and external dataset shift remains insufficiently understood. In this work, we introduce DMSNet, a deformable adaptive multi-scale edge-guided attention network integrating adaptive multi-scale feature fusion, deformable lesion refinement, edge-guided attention, and sparse feature selection. We benchmark DMSNet against 18 representative convolutional, transformer-based, and pretrained vision architectures on Kvasir-Capsule under random frame-level and source-video-disjoint validation protocols. We further identify source-video overlap between the original training and test splits and evaluate model performance on both the complete test set and a source-video-disjoint subset. Under random frame-level validation, DMSNet achieves an MCC of 0.442 $\pm$ 0.020 on complete test set and 0.456 $\pm$ 0.037 on the source-video-disjoint subset. On the external CV2024 dataset, ConvNeXt-Tiny achieves the highest MCC of 0.207, while performance degrades substantially across architectures relative to in-domain evaluation. We further investigate source-video diversity using a per-class cap of 200 training frames. With the total training-set size held fixed, increasing the maximum source-video coverage from four to eight improves MCC for 17 of 19 evaluated architectures. Overall, these findings demonstrate that model rankings and classification performance depend substantially on evaluation protocol, training-source diversity, and cross-dataset shift, emphasizing the need for source-aware validation and rigorous external evaluation of VCE classification systems.

0.22

CheXFuse: Guided Differential Joint Attention Fusion for Robust Multimodal Chest X-Ray Classification in Data-Scarce Medical Settings

cs.CV cs.LG ·2026-10-19 ·Muntaqim Ahmed Raju, Priyanka Siddappa, Md Shifat Haider Al Amin, Ruizhe Ma, Md Ripon Ahammed
publishedhighly cited similarity 0.70
Abstract · IEEE ICDM DMBIH 2026

A central challenge in multimodal learning is how to fuse modalities that differ substantially in predictive strength. When one modality provides a much stronger representation than another, indiscriminate cross-modal interaction can introduce weak, redundant, or unstable signals, limiting or even degrading performance relative to the strongest unimodal representation. To address this problem, we propose CheXFuse, a multimodal fusion framework based on Guided Differential Joint Attention (GuDJA). CheXFuse combines image and text token representations within a joint multimodal sequence, where learned token guidance emphasizes informative representations and differential attention reduces less useful attention responses. We evaluate CheXFuse on the Indiana University (IU) Chest X-ray dataset, using binary (normal vs. abnormal) classification as the downstream task. Experiments are conducted under both original-report and masked-report settings, with the latter serving as a controlled stress test under reduced textual informativeness. CheXFuse with GuDJA achieves the strongest mean overall performance across the evaluated baselines and ablations, reaching 95.73% accuracy, 95.79% F1-score, 96.54% recall, and 95.28% sensitivity at 95% specificity (Sens@95Spec) with original reports, and 95.58%, 95.60%, 95.60%, and 94.34%, respectively, under masked reports. These results suggest that GuDJA provides a promising fusion strategy under asymmetric or partially reduced modality informativeness.

0.49

Attention Residual U-Net for Enhanced Cross-Dataset Polyp Localization in Endoscopy

cs.CV ·2026-11-02 ·Romil Imtiaz, Dimitris K. Iakovidis
similarity 0.69
Abstract

Precise localization of pathologies in endoscopy is a critical task in medical imaging, with deep learning (DL) frameworks now serving as the primary methodology for automated lesion detection. Today, generic object detection methods, such as YOLO, provide state-of-the-art performance in this context. However, their robustness often decreases under real-world clinical conditions due to variations across endoscopic devices, intestinal content, dataset bias, and the presence of small or low-contrast lesions. Motivated by these challenges, we propose a novel polyp detection framework based on a Attention Residual U-Net offering enhanced polyp localization. Instead of directly regressing bounding boxes from global feature representations, the proposed method learns lesion-focused spatial representations and converts them into bounding-box predictions during inference. Unlike conventional encoder-decoder localization frameworks that directly propagate all encoder activations into the decoding pathway, the proposed method selectively suppresses irrelevant background responses before feature reconstruction. This encourages the network to focus on lesion-relevant spatial evidence under heterogeneous imaging conditions. To achieve this, the framework integrates residual feature propagation, attention-guided encoder filtering, and multi-scale contextual learning. The proposed framework was evaluated on multiple public endoscopic datasets acquired using different devices. The comparative experimental results validate its effectiveness over the relevant state-of-the-art methods, with an improvement up to 22.0% in terms of the area under the receiving operating characteristic (AUC).

0.18

CEM-TUDASR: Computationally efficient multi-modality transformer based unsupervised domain adaptive super-resolution approach

cs.CV ·2026-09-10 ·Anjali Sarvaiya, Jay Kadel, Kishor Upla, Kiran Raja
published similarity 0.69
Abstract · Published in Biomedical Signal Processing and Control, Volume 129, 2027, Article 111315

Wireless Capsule Endoscopy (WCE) enables non-invasive visualization of the gastrointestinal tract, but its miniaturized optics, sensor limitations, and wireless transmission constraints result in low-resolution images with reduced visibility of diagnostically important structures. This paper proposes CEM-TUDASR, a computationally efficient unsupervised Transformer-based super-resolution framework for WCE image enhancement without paired low-resolution (LR) and high-resolution (HR) training data. A domain-adaptive degradation network synthesizes realistic WCE-like LR images from HR conventional endoscopy images, reducing the domain gap and enabling effective unpaired learning. The SR generator integrates Deep Attention Blocks (DABs) and a Fusion Attention Block (FAB) to capture long-range contextual dependencies and fine local structures while preserving perceptual and structural fidelity. The model is trained on a curated dataset derived from Kvasir Capsule and evaluated on KID and GIANA for cross-dataset generalization. No-reference quality metrics, including BRISQUE, PIQE, NIQE, and the domain-specific EndoQM, show that CEM-TUDASR consistently outperforms existing unsupervised SR methods. Qualitative results further demonstrate improved restoration of mucosal textures, vascular patterns, and clinically relevant anatomical details. Cross-domain experiments on retinal images additionally demonstrate the adaptability of the framework. With only 2.67 million parameters and 169.94 GFLOPs, CEM-TUDASR achieves high-quality reconstruction while maintaining computational efficiency, making it suitable for resource-constrained clinical and embedded endoscopic applications.

0.18

Accuracy Is Not Enough: An Efficiency- and Statistics-Aware Benchmark of ResNet50 and Vision Transformer for Explainable Multi-Class Gastrointestinal Diseases Classification

cs.CV ·2026-10-25 ·Akwasi Asare
benchmarkhot direction similarity 0.68
Abstract

Automated classification of gastrointestinal (GI) findings in endoscopic images could support early diagnosis, but architectures are often chosen on accuracy alone. We present a controlled, reproducible benchmark of ResNet50 and ViT-B/16 for eight-class GI classification on the public Kvasir dataset (4,000 images), using a stratified split (400 test images) and stratified group 5-fold cross-validation over all images. In cross-validation, ResNet50 and ViT-B/16 reached 92.12% and 91.70% accuracy, and a two one-sided tests (TOST) procedure showed equivalence within a +/-3 percentage-point margin (difference +0.43 points, 90% CI -0.33 to +1.18; p < 0.001). The architectures differed mainly in cost: ResNet50 had 3.6 times fewer parameters and 4.3 times fewer operations, 2.5-fold lower single-image CPU latency (69 vs. 177 ms) and 3.8-fold higher GPU throughput. Cross-validated calibration was similar (expected calibration error 0.021 vs. 0.023). An edge-oriented transformer, MobileViT-S, was most accurate on the test split (95.5%) but lost 9.4 points when an acquisition artefact present in some classes (the ScopeGuide inset) was occluded, whereas ResNet50 was not significantly affected. On 500 unseen polyp images with expert masks, both models' Grad-CAM maps focused on the lesion (3.6 times chance). On a de-duplicated external subset of GastroVision (1,998 images), accuracy fell to 78-80% for all three models and differences between them remained small. Accuracy differences between architectures were thus small relative to the effects of shortcut learning and domain shift, whereas efficiency differences were large. An efficient CNN is a defensible default for resource-constrained screening, but no model is deployment-ready without local validation.

0.29

Learning Features, Not Layouts: Feature-Axis Attention as a Transfer Prior for Medical Imaging

cs.CV ·2026-10-09 ·Aon Safdar, Mohamed Saadeldin
published similarity 0.66
Abstract · 17 pages, 5 figures. Accepted at ACCV 2026

Natural-image-pretrained foundation models are increasingly adapted to medical imaging, yet transfer remains unreliable under domain shift, modality heterogeneity, and label scarcity. We trace part of this fragility to an overlooked design choice. Standard vision transformers place all global modeling on self-attention over spatial tokens, an object-layout prior well suited to natural scenes but not to medical images, where the discriminative signal lies in feature correlations and texture that recur across scanners while layout does not. We ask whether the axis of global attention, spatial versus feature, is itself a lever for transferable medical representations. Existing channel-aware hybrids confound this question, adding channel attention to a spatially-mixed backbone and leaving the axes coupled and the feature axis unmeasurable in isolation. We design FAD-ViT, a backbone that strictly decouples the two axes, making feature-axis attention the primary global operator and the attention axis a controlled variable. Evaluating comprehensively across 23 classification, segmentation, and low-data tasks under matched tokenization, capacity, and protocol, we find that shifting global attention from the spatial to the feature axis leaves from-scratch performance essentially unchanged, yet markedly strengthens transfer. Identical ImageNet pretraining yields up to roughly three times the transfer gain, with consistent improvements on every held-out segmentation task at up to a quarter the parameter count and far lower compute than standard and channel-attention baselines. The advantage is largest where texture rather than geometry is discriminative, tracking greater reuse of pretrained features. The axis of global attention is thus a design lever for medical transfer, and making it channel-primary is a simple, cheap, and principled choice.

0.32

CXR-CMFA: A Cross-Modal Feature Aggregation Network for Chest X-Ray Pathology Classification

cs.CV cs.AI ·2026-11-06 ·Talukder Hasnat Zadid, Jahin Sultana, Felipe Bochini Brisola, Kishore Roy, Mysha Rahman +2 more
benchmark similarity 0.66
Abstract

Chest X-ray (CXR) interpretation remains challenging because subtle pathology can be obscured by overlapping anatomy, image-quality variation, and limited visual evidence in isolated radiographs. Although image-only deep learning models provide useful baselines, they discard the complementary diagnostic context available in radiology reports, while large vision-language models can be computationally expensive for practical deployment. This paper presents CXR-CMFA, a lightweight cross-modal feature aggregation network for binary CXR pathology classification. The proposed framework combines a dual-stream visual encoder, using EfficientNet-B0 for global anatomical representation and DenseNet-121 for local pathological detail, with a TF-IDF-MLP report encoder. Two fusion modules integrate these modalities: the Dual-Modal Spatial Attention Module (DMSAM) uses the report embedding to gate global and local visual features, and the Cross-Modal Gated Feature Fusion (CGFF) module learns per-instance weights for visual and textual contributions. Experiments on the MIMIC-CXR benchmark, using the provided train, validation, and test splits, show that CXR-CMFA achieves 93.45% accuracy, 99.88% precision, 91.8% recall, 95.7% F1-score, and 99.19% AUC on the held-out test set. The model produces only four false positives among 984 normal test cases, supporting its suitability for high-specificity screening workflows. An ablation study further demonstrates a 22.47 percentage-point AUC improvement over the global-image-only variant, confirming the value of adaptive cross-modal fusion. These results indicate that compact report-conditioned fusion can provide strong discriminative performance without relying on large pretrained language models.

0.14

Weakly-supervised Kidney Tumor Classification from CT Scans with Multi-Instance Learning and Anatomical Filtering

cs.CV ·2026-09-07 ·Joonas Ariva, Dmytro Fishman
similarity 0.66
Abstract · 16 pages, 3 figures

Deep learning models for CT scan analysis are often limited by the scarcity of precise pixel-level annotations, which require significant radiologist effort to produce. Training on scan-level labels alone reduces annotation requirements but introduces challenges: low supervision ratios and large input volumes make models prone to overfitting and shortcut learning. In this work, we investigate two complementary methods to address these challenges: multi-instance learning (MIL) and anatomical filtering. MIL divides CT volumes into 2D slice instances, enabling efficient 2D architectures with ImageNet pretraining rather than computationally demanding 3D models. Anatomical filtering uses Compass, our self-supervised body part regression model, to crop scans to pathology-relevant subregions without requiring segmentation masks. We evaluate two MIL frameworks - Attention-based MIL (ABMIL) and FocusMIL - on kidney tumor classification across one internal dataset (TUH) and two external datasets (KiTS23 and TCGA-KiRC). Our best models achieve F1 = 0.83 on the internal test set using only scan-level labels. We further show that anatomical filtering with the Compass model is critical for the out-of-distribution generalization of embedding-based ABMIL, while instance-based FocusMIL demonstrates greater inherent robustness to distribution shift. While evaluated on kidney tumors, we consider this a proof-of-concept for a broader weakly supervised CT classification pipeline applicable to other organs and pathologies.

0.16