CS Paper Radar

MedWER: A Reproducible, Model-Free Evaluation Protocol for Medical Speech Recognition

Justin Behling

cs.CL ·submitted 2026-09-04 21:19 UTC · v1
code/data

Abstract

Overall word error rate hides clinically critical errors: a transcript can be 95% correct and still swap one drug for another. The usual fix weights errors on medical entities, and almost always depends on an evaluation-time named-entity recognition (NER) model or cloud API, which makes the metric's denominator a versioned black box. We present MedWER, an evaluation protocol and open-source tool for medical ASR whose denominator is a fixed, license-clean term list: 19,373 drug, diagnosis, symptom, and injury-mechanism entries projected from public sources. The protocol couples a pinned text normalizer with a phrase-aware term-restricted WER, the MedWER, so the only versioned component is a normalizer dependency held at an exact release and checked against committed golden fixtures. Coverage is validated against an independent provincial drug-benefit file the list was not built from; the matching heuristic is calibrated against ground-truth entity spans. Baselines for Moonshine~base, Whisper~base.en, and MedASR on two open benchmarks are scored with the released tool and reported with 95% confidence intervals from resampled per-utterance scores.

Comment
10 pages, 3 tables. Code, term list, and evaluation scripts: https://github.com/Nordis-Tech/medwer. Package: pip install medwer. Source archive: https://doi.org/10.5281/zenodo.22103865

Closest papers

Nearest neighbours by meaning across the whole index.

A local language model layered with rule-based and neural detectors for clinical text de-identification: an open-source toolkit and evaluation

cs.CL cs.CYcs.SE ·2026-11-09 ·Valentin Burkin
code/data similarity 0.70
Abstract · 17 pages, 2 figures, 4 tables; supplementary material as ancillary file. Code: https://github.com/valburkin/DeidSharp

Objectives: To measure whether a locally hosted large language model (LLM), stacked with deterministic and clinical named-entity recognition (NER) detectors, finds more protected health information (PHI) than open tools, and at what precision. Materials and Methods: DeidSharp, an open-source .NET toolkit, combines the findings of pluggable detectors (patterns, a clinical NER model, a local 26B mixture-of-experts LLM) and fails closed on any detector error. Configurations fixed on tuning halves were compared, under a prespecified protocol, with deid, Philter, the Stanford/Penn de-identifier, OpenAI Privacy Filter and GLiNER on reporting halves of PhysioNet's nursing notes (889 spans) and semi-synthetic MIMIC-IV-Note discharge summaries (29,023 spans), and on synthetic ASQ-PHI queries, with paired patient-level bootstrap intervals. Results: In the nursing notes, against Stanford/Penn, the recall-first stack found 98.9% of PHI (+2.8, 95% CI 1.4 to 4.4) at 9.3 points lower precision; the precision-first stack, without NER, found 96.5%, matching Stanford/Penn, at 19.6 points higher precision (83.2%). In the discharge summaries, both stacks led Stanford/Penn by more than 20 points (recall-first 95.3%, +21.5, 20.5 to 22.4), almost entirely on generated untyped names; on typed labels all three exceeded 99%. All four prespecified comparisons held. No configuration beat deid significantly on its home corpus; Philter found more discharge-summary spans than the recall-first stack at 23 points lower precision. Discussion: The LLM was the main detector and NER added place names; asked to verify its own findings, the LLM discarded a quarter of true PHI. Conclusion: A local LLM layered with deterministic detectors offers recall-first and precision-first operating points without sending text off-site.

0.36

MedAstra: ASR-less Speech Retrieval with Diagnostic Grounding for Medical QA

cs.CL ·2026-10-31 ·Elahe Khatibi, Ziyu Wang, Amir M. Rahmani
similarity 0.67
Abstract

Spoken medical question answering can fail when automatic speech recognition (ASR) corrupts a clinically important term before retrieval. We present MedAstra, a framework that maps frozen WavLM speech representations through a lightweight adapter into a frozen E5 text embedding space. This enables a dense retrieval path that accepts a waveform without a query transcript. Retrieved passages and speech-linked textual metadata support answer generation with entity alternatives, diagnostic contrasts, relation heuristics, and bounded retrieval refinement. ASR-less refers to the initial speech retrieval interface; lexical retrieval, string-based entity correction, and the text generator require textual inputs. The deterministic speech embedding does not constitute a calibrated model of acoustic uncertainty. Reported retrieval results reach 87.6 Recall@10 for the speech-only retriever and 90.4 for the hybrid configuration, compared with 81.0 for transcript-first dense retrieval. Medical QA and ablations provide descriptive system comparisons, with input-provenance and evaluation limitations stated explicitly. We distinguish controlled synthetic acoustic tests from real clinical speech, qualify component attribution, and specify the remaining comparisons needed to assess speech-only QA and clinical generalization.

0.16

OncoNoteBERT: A Foundation Representation Model for Natural Language Processing of Real-World Outpatient Oncology Notes

cs.CL cs.AIcs.LGq-bio.QM ·2026-10-02 ·Wuraola Oyewusi, Eliana Vasquez Osorio, Goran Nenadic, Gareth Price
published similarity 0.66
Abstract · Accepted at the AI at Scale for Clinical Impact (ASCI): Cancer Pathology Foundation Models Workshop at NeurIPS 2026

Real-world outpatient oncology notes contain specialised terminology, tumour staging expressions, treatment names, toxicity descriptions, and institution-specific de-identification markers that may not be represented efficiently by general biomedical or adjacent clinical language models. We developed and evaluated oncology-specific BERT-style encoders using a governed UK outpatient oncology corpus comprising 290,026 notes from 21,564 patients treated for lung and head-and-neck cancer. We compared RadBERT and PathologyBERT with two local strategies: OncoNote-RadBERT, produced by continued masked language model pretraining, and OncoNoteBERT, trained from scratch with an oncology WordPiece tokenizer. Models were evaluated using masked language modelling loss and perplexity on the validation set, tokenizer fragmentation metrics, clinical term tokenisation, masked-token probes, and exploratory representation analysis. Both external encoders fit the oncology corpus poorly in zero-shot evaluation (perplexity 113.04 for RadBERT; 2035.03 for PathologyBERT), while continued pretraining produced the strongest fit (2.10 for OncoNote-RadBERT). OncoNoteBERT achieved perplexity 2.83 but produced the most efficient tokenisation, with lower subword fertility and shorter normalised sequence length. It also returned a clinically acceptable prediction for 12 of 13 masked-token probes, compared with 7 of 13 for OncoNote-RadBERT. This divergence between corpus-level fit and masked-token performance was partly attributable to tokenizer fragmentation rather than learned semantics alone. Both locally developed models represented the institutional placeholder as a single learnable token. These findings show that continued adaptation and bespoke tokenisation provide complementary benefits, and that representation-layer design matters before adjacent-domain encoders are applied to oncology NLP.

0.30

En-ViMedNER: An English-Vietnamese Parallel Biomedical Corpus with UMLS Semantic Type Annotations

cs.CL ·2026-08-30 ·Nhu Vo, Phuong Nguyen, Nu Uyen Phuong Le, Inigo Jauregi Unanue, Dung D. Le +2 more
top venuebenchmark similarity 0.66
Abstract · To appear in Proceedings of EMNLP2026

Biomedical Named Entity Recognition (NER) is fundamental to healthcare AI applications, including clinical decision support and medical information extraction. While corpora with Unified Medical Language System (UMLS) annotations, such as MedMentions, have driven progress in English biomedical NER, no comparable resource exists for Vietnamese. This paper presents En-ViMedNER, the first English-Vietnamese parallel biomedical NER corpus annotated with UMLS semantic types, which are language-neutral codes providing a shared cross-lingual label space and ensuring direct comparability with existing UMLS-based resources. The corpus contains 4,392 PubMed abstract pairs, 44,892 English-Vietnamese sentence pairs, and 202,949 aligned entity-mention pairs across 21 semantic types adapted from the MedMentions ST21pv dataset. To balance quality and scalability, we have constructed the corpus through automatic translation, expert post-editing, LLM-assisted label projection, and human verification and adjudication. We characterize En-ViMedNER as a large-scale silver-standard corpus with a human-audited and consensus-corrected mini-test subset. We evaluate En-ViMedNER in two settings: (i) Vietnamese-input/Vietnamese-output biomedical NER and (ii) English-input/Vietnamese-output cross-lingual NER. For Vietnamese NER, we benchmark Vietnamese-supervised encoder models, English-supervised multilingual encoder models, and prompt-based LLMs. The best model achieves an F1 score of 52.70 on the test set and 53.78 on the mini-test set. For cross-lingual NER, we benchmark encoder-decoder models and prompt-based LLMs. The best model achieves an F1 score of 45.44 on the mini-test set. We publicly release our corpus, corpus construction pipeline, and baseline models to facilitate future Vietnamese biomedical NLP research.

0.50

Pronouncing Hard Words: Phoneme Adaptation of a Pretrained Conversational Text to Speech Model

cs.CL eess.AS ·2026-10-16 ·Yashish M. Siriwardena, Dinesh K. Gnanasekaran, Tanmay Laud, Shinji Watanabe, Subhabrata Mukherjee +1 more
similarity 0.65
Abstract · 5 pages

Voice agents built as cascaded automatic speech recognition (ASR)->large language model (LLM)-> text-to-speech (TTS) pipelines increasingly rely on conversational TTS: streaming, context conditioned models that adapt delivery to dialogue history. Such models are natural and expressive but offer little explicit control over how rare, trust-critical drug names are pronounced, because these entities are too infrequent, and their vocabulary too fast-growing, to be covered by any amount of pre-, mid-, or post-training. We retrofit phoneme controllability onto a pretrained conversational TTS model without any pre/mid-training, using an ARPAbet vocabulary exten-sion, continued phoneme-augmented supervised fine-tuning (SFT), and a training-free inference-time acoustic-biasing step. On a 7,500 clip clinical drug-pronunciation evaluation, our model raises strict Gemini-judged correctness from 54.6% (no phoneme augmentation) to 90.7%, outperforming every conversational and stateless TTS baseline on the automatic metric. Because no training stage sees a drug name, the entire evaluation is out-of-domain, so the gains reflect learned pronunciation rather than memorization. In a blinded, randomized human study, adult listeners judge 84% of our clips correct, versus 82% for the strongest baseline, with overlapping confidence intervals on a stratified subset. Across all 250 matched clips, Gemini agrees with the human majority on 84.8% of binary labels (k{appa}=0.57).

0.18

From archive to resource: bringing legacy data back to life at scale with large language models

cs.IR ·2026-10-23 ·C. H. Vieira-Vieira, I. Schneider Chernov, A. Serra, M. Correa Marrero, P. L. Bhavani Mohan +3 more
benchmark similarity 0.64
Abstract

Pharmaceutical companies maintain vast archives of legacy preclinical study reports that contain study-context details, such as fasting, anesthesia, and laboratory instrumentation, that are rarely captured in structured data formats, yet they can correlate with clinical pathology parameters values and limit the reuse of historical data. This work demonstrates practical, scalable solutions to recover such descriptors from heterogeneous report texts using large language model (LLM)-based extraction pipelines developed independently by two industry teams. The pipelines identify and normalize metadata fields and return verbatim evidence with page and section reference, hasting human verification and iterative refinement. Evaluation of over 400 documents against expert-curated reference values showed high agreement across a broad set of metadata fields. Performance was strongest for consistently reported items and lower for descriptors subject to linguistic or report structure variability. Extraction time has shrunk from 25 minutes in the manual benchmark to 1.6 minutes. As a concrete biological demonstration, we show that fasting status extracted from report text was associated with species- and analyte-specific shifts in clinical chemistry parameters, illustrating how recovered metadata can improve selection of historical controls. Key strengths of the approach are scalability, traceability, and the ability to recover information missing from current industry standards. Main limitations are dependence on source-report quality and initial expert effort to define and refine schemas. These results establish how LLMs can convert heterogeneous, unstructured legacy reports into evidence-grounded, reusable and structured metadata, leading to better experimental comparability, and thus enabling reliable data pooling or informed virtual control selection.

0.28

Text-Only Domain Adaptation for Low-Resource Medical ASR: Shallow Fusion and Density Ratio Rescoring for Hausa

cs.LG cs.AIcs.CL ·2026-11-03 ·Oche David Ankeli, Hassan Adelani Luqman, Theodora Ngozi Egbunike, Joshua Gottschalk, Bonaventure F. P. Dossou
similarity 0.64
Abstract

Automatic speech recognition (ASR) systems often struggle with specialised medical vocabulary, especially in low-resource languages where domain-specific speech data are scarce. We investigate text-only domain adaptation for Hausa medical ASR using the fixed MMS-1B-FL102 acoustic model and two decoding-time language-model fusion methods: Shallow Fusion (SF) and the Density Ratio Approach (DRA). A 4-gram KenLM trained on 19,421 Hausa health sentences serves as the medical target model, while a 75,372-sentence general-domain model provides the source prior for DRA. Evaluation uses 250 recordings of 25 physician-reviewed prompts from 10 speakers across six northern Nigerian states. Under prompt-disjoint five-fold cross-validation, SF and DRA reduce WER from 29.56% to 23.55% and 23.33%, respectively. Both significantly outperform greedy decoding (p < 0.001), while their difference is not significant (p = 0.423). However, general-LM-only SF achieves 23.96% WER, indicating that the medical LM's additional improvement over a general LM is modest. Medical Term Error Rate also improves under fusion, but does not establish a distinct medical-domain advantage. These findings demonstrate that lightweight, text-only language-model fusion can improve Hausa medical ASR without additional domain-specific speech collection.

0.07

Fine-Grained Japanese Clinical Named Entity Recognition: A Controlled Comparison of BERT and Open-Weight Large Language Models

cs.AI cs.CL ·2026-11-17 ·Feng Han, Ayako Yagahara, Kenji Hirata, Atsushi Yoshida, Kohsuke Kudo
benchmark similarity 0.64
Abstract · 33 pages, 3 figures, 5 tables; includes appendices with supplementary tables and one supplementary figure

Background: Generative large language models (LLMs) offer an alternative to encoder-based clinical named entity recognition (NER), but their performance on fine-grained Japanese extraction tasks and sensitivity to generation settings remain uncertain. Methods: We compared two fine-tuned BERT-CRF baselines with nine open-weight LLMs on iCorpus, which defines 113 entity categories. The evaluation used 433 sentences from 36 test documents; 1,672 sentences were used for training. LLMs were evaluated using zero-shot prompting with and without JSON Schema constraints and three-seed QLoRA fine-tuning. Fine-tuned models were assessed under different output-token limits, including 900 and larger model-specific limits of 2,600 or 4,096 tokens. Performance was measured using sentence-level label-surface matching with relaxed and exact-surface F1. Results: The highest zero-shot relaxed F1 was 0.337, compared with 0.836-0.841 for the BERT baselines. At the larger output limits, all eight fine-tuned LLMs with at least 13B total parameters exceeded both BERT baselines (relaxed F1, 0.882-0.914; exact-surface F1, 0.840-0.880). Across three-seed means, increasing the output limit improved relaxed F1 by 0.052-0.085, alongside higher recall and fewer length-limited outputs. JSON Schema constraints changed relaxed F1 by -0.014 to +0.008 among seven models outside the two reasoning-oriented configurations, while medical-general model pairs showed no consistent advantage for medical specialization. Conclusions: On this historical Japanese case-report benchmark, task-specific fine-tuning combined with adequate generation capacity was associated with stronger LLM extraction performance. Output-token limits materially affected comparisons with BERT, whereas enforcing output structure alone did not overcome low zero-shot accuracy.

0.11