CS Paper Radar

FPicker: Topology-Guided Evolution for Filament Tracing in Low-SNR Microscopy

Tingyin Zhao, Mingtao Huang, Yuan Shen

cs.CV cs.AI ·submitted 2026-09-08 06:25 UTC · v1
top venuecode/data

Abstract

Automating filament tracing in Cryo-Electron Microscopy (Cryo-EM) is essential for 3D helical reconstruction but challenged by intersecting topologies and extremely low Signal-to-Noise Ratios ($\text{SNR} = σ_s^2/σ_n^2$ < 0.1 or -10 dB). Existing paradigms fail: pixel-wise segmenters suffer from severe topological fracturing, box-based detectors face ghost center drift, sequential trackers derail due to error accumulation, and traditional active contours collapse under artificial closed-curve constraints. To resolve these bottlenecks, we present FPicker, the first topology-guided framework reconciling these incompatibilities. It unifies perception via a center-endpoint representation and an open-curve evolution module to explicitly model non-cyclic connectivity. On simulated benchmarks, FPicker outperforms top baselines by over $40\%$ relative gain in mean spatio-angular precision (mSAP) and reduces topological gap rates by over $60\%$ under extreme noise ($-20\text{ dB}$). By learning intrinsic physical geometry rather than local texture, FPicker demonstrates strong potential as a resilient geometric backbone. Its zero-shot performance on the real-world EMPIAR dataset exhibits robust topological resistance, achieving a state-of-the-art 82.9\% mSAP upon fine-tuning. Our results also suggest modeling physical priors is a highly robust path toward bridging the sim-to-real gap in signal-starved scientific imaging. The code is publicly available at: https://github.com/tomzhaosky/FPicker.

Comment
Accepted to the 19th European Conference on Computer Vision (ECCV 2026). 18 pages, 6 figures. Code is publicly available at: https://github.com/tomzhaosky/FPicker
Journal ref
Computer Vision - ECCV 2026. Lecture Notes in Computer Science, vol 17014. Springer, Cham
DOI
10.1007/978-3-032-37232-1_7

Closest papers

Nearest neighbours by meaning across the whole index.

TopoFuse: Topology-Aware Tri-Planar Fusion for 3D Cryo-Electron Tomography Segmentation

cs.CV ·2026-08-31 ·Rohit Kumar Salla, Neelesh Gupta, Xingjian Li, Min Xu
top venueunusual similarity 0.64
Abstract

Automated segmentation of cryo-electron tomograms routinely produces masks that are voxel-accurate but topologically broken: membranes fragment, organelles merge into one another, and enclosed cavities collapse. Existing topology-aware losses reduce these violations but cannot eliminate them, because topology is encouraged through gradient pressure rather than structurally enforced. We introduce TopoFuse, which reframes topology as a differentiable projection operator rather than a loss penalty. At each forward pass, the projection operator $\mathrm{Proj}_T$ (a PH-guided sparse edit) identifies the critical voxels responsible for topological violations via bottleneck matching and applies sparse edits to satisfy a specified topology target (diagram feature counts and lifetime budgets) for dimensions $d \in \{0,2\}$. If the projection converges, the output satisfies those constraints on the downsampled grid ($s=2$); when it does not, a repair certificate exposes this explicitly, enabling downstream filtering. A topology prior head predicts the correction target directly from input features, removing any dependence on ground-truth topology at inference. Across three cryo-ET benchmarks, TopoFuse reduces Betti number error by 54% over the strongest soft-loss baseline ($p < 0.001$), improves Dice by 4.6 points, and edits only 3.1% of voxels to achieve this.

0.44

CryoTracer: A Synthetic-to-Real System for Filament Instance Tracing in Cryo-EM

cs.CV ·2026-10-13 ·Radosław Kuczbański, Wojciech Kozłowski, Mateusz Grzesiuk, Konrad Karanowski, Lukas Frey +2 more
code/data similarity 0.62
Abstract

Particle picking in cryo-electron microscopy is commonly formulated as an object-detection problem in which individual particles are represented by bounding boxes, a natural representation for globular particles but a poor match for filaments that can extend across an entire micrograph. Existing methods reconstruct filament trajectories by linking local predictions in a separate post-processing stage, decoupling detection from instance formation and creating potential ambiguities at gaps and crossings. Directly preserving filament identity is particularly useful for polymorphic specimens, where segments originating from the same filament should remain associated. However, learning such instance-level representations is challenging because expert centerline annotations are scarce and costly to obtain. We introduce CryoTracer, a synthetic-to-real framework that addresses this limitation through procedural micrograph generation, transformer-based polyline prediction, and specimen-specific fine-tuning. Procedural pretraining exposes the model to diverse filament geometries, intersections, and imaging conditions before adaptation using a limited number of fully annotated experimental micrographs. CryoTracer represents filaments as ordered centerline polylines and optimizes their geometry using an orientation-invariant discrete Fréchet objective, enabling consistent learning regardless of tracing direction. Evaluation on established and newly expert-annotated datasets shows that CryoTracer improves instance-level filament recovery over existing particle-detection approaches. These results establish end-to-end polyline prediction as a practical alternative to detection-and-linking pipelines for recovering complete filament instances with limited micrograph annotation budgets. Code and data are available at https://github.com/cryotracer/cryotracer

0.32

SkNeXt enables topology-guided neuronal reconstruction from petabyte-scale microscopy data

cs.CV ·2026-09-09 ·Jiayi Ding, Hu Zhao
similarity 0.57
Abstract

Recent advances in high-resolution fluorescence and electron microscopy have enabled nanoscale imaging across increasingly large brain volumes, but the resulting terabyte- to petabyte-scale datasets make complete neuronal reconstruction prohibitively expensive in computation, data movement, and manual proofreading. Here, we present SkNeXt, a topology-first framework for scalable neuronal reconstruction from large volumetric microscopy datasets. Instead of densely processing entire image volumes, SkNeXt first converts neuronal morphology into compact SWC skeletons that preserve long-range connectivity. Proofreading is therefore focused on sparse neuronal trees, allowing branch, continuity, and connectivity errors to be corrected before high-resolution reconstruction. The corrected skeletons then serve as persistent structural priors for recovering detailed morphology while preserving neuronal identity and topology. Crucially, SkNeXt also uses neuronal skeletons as spatial indices for selective data access, retrieving high-resolution image regions only along reconstructed trajectories and bypassing most background and signal-free volumes. This substantially reduces I/O and computational overhead, allowing reconstruction cost to scale with neuronal morphology rather than total dataset size. Using SkNeXt, we reconstructed neurons from a petabyte-scale super-resolution fluorescence dataset of the mouse brain on a single GPU within one week, without requiring exhaustive dense inference across the complete imaging volume.

0.25

TRACE: Topology-Aware Reconnection via Prediction-Adaptive Connectivity Enforcement for Thin-Structure Segmentation

cs.CV cs.AI ·2026-10-15 ·Junho Moon, Ikbeom Jang
published similarity 0.56
Abstract · Accepted to WACV 2027

Thin, elongated structures are particularly sensitive to connectivity errors, as even a few local segmentation mistakes can disrupt otherwise continuous paths. Existing skeleton-based objectives typically supervise fixed centerline locations and do not account for alternative local routes that may restore connectivity. We propose TRACE, a topology-aware, prediction-adaptive objective that uses a target skeleton to define required local connections. For each connection, TRACE identifies the easiest valid reconnection under the current prediction and jointly supervises its bottleneck with the corresponding skeleton point. The supervision thus adapts to the evolving prediction rather than remaining fixed to the centerline. We further introduce a topology-aware skeleton carrier that preserves both foreground and class-specific topology, enabling reliable definition of these connections. Extensive experiments across six 2D and 3D benchmarks show that TRACE improves connectivity and topology while maintaining strong segmentation accuracy with low training overhead. Code will be released upon acceptance.

0.40

OcTreeMamba: Topology-Aware Mamba for 3D Medical Segmentation via Octree Sparsification

cs.CV ·2026-11-05 ·Kaixiang Mai, Jiaqi Yu, Yuzhu Ji, Yiqun Zhang, Zhijie Wang +2 more
publishedbenchmarkcode/data similarity 0.55
Abstract · 8 pages, 5 figures, accepted by IEEE BIBM 2026

Accurate segmentation of 3D anatomical structures is crucial to medical image analysis. Recently, Mamba-based approaches have achieved promising segmentation performance in capturing long-range dependencies with linear-time computational complexity. However, heuristic selective scanning strategies inherently disrupt the intrinsic spatial hierarchy and increase computational redundancy, ignoring the inherent sparsity of 3D anatomical structures. To this end, we propose OcTreeMamba, a hierarchical framework that incorporates Octree structures into SSM, achieving 3D topology-aware long-range context feature propagation and integration. Specifically, a Structure Learner performs anatomy-adaptive structured sparsification through hierarchical gating and Gumbel-Softmax sampling, enabling differentiable selection of anatomical regions. The selected regions are subsequently organized by a Dynamic Octree Builder into a multi-level topology that preserves their hierarchical connectivity. Based on the constructed Octree, a bidirectional Tree-SSM propagates and integrates contextual features along connectivity-aware leaf--parent--root and root--parent--leaf trajectories. Extensive experiments on four benchmark datasets show that our proposed OcTreeMamba achieves competitive performance \wrt topological continuity and computational efficiency, particularly for recovering the complex structure on vascular datasets. The code is available at https://github.com/MikeMak123/OcTreeMamba.

0.47

Reconstruction-Aware Cryo-EM Particle Picking

cs.CV q-bio.BM ·2026-08-28 ·Riku Itsuji, Yuanhao Wang, Xingjian Li, Seonghui Min, Hideo Saito +1 more
similarity 0.55
Abstract

Cryo-electron microscopy (cryo-EM) determines the structures of proteins and macromolecular assemblies at near-atomic resolution, and the final 3D reconstruction depends on extracting a clean particle stack from noisy micrographs. This extraction decomposes into three sub-tasks, namely particle picking, contamination removal, and 2D class selection. Each of them, however, is trained and evaluated in isolation, and none is optimized for the reconstruction. We instead integrate the three sub-tasks into a single pipeline posed against downstream reconstruction quality. We instantiate the pipeline with a state-of-the-art component for each sub-task, CryoTransformer picking permissively, MicrographCleaner masking contamination, and CryoSift selecting 2D classes by a continuous quality score, and close the loop with a fine-tuning step that returns the surviving particles to the picker. The pipeline achieves a better 3D resolution than every picker we compare. We also show that the best 2D F1 is not the best resolution, so particle selection is better treated as one reconstruction-aware pipeline judged by the map it delivers.

0.23

CORAL: A Benchmark for Structure-aware and Brain-wide Neuron Reconstruction in Light Microscopy

cs.CV ·2026-08-31 ·Zekang Yang, Jiamin Li, Zhenghua Li, Jiaqi Fan, Zengcai Guo +1 more
benchmark similarity 0.55
Abstract

Automatic neuron reconstruction from light microscopy images is a central problem in computational neuroanatomy. While recent methods have achieved encouraging results on local image blocks, it remains unclear whether such progress translates to reconstruction that is both structurally accurate and scalable to the whole-brain scale. We present CORAL, the first benchmark for structure-aware evaluation of automatic neuron reconstruction from light microscopy images at both local and whole-brain scales. Built on a high-quality whole-brain fMOST dataset with carefully curated annotations, CORAL establishes two progressive tasks: block-level reconstruction, which evaluates reconstruction methods under limited spatial context, and brain-wide reconstruction, which assesses complete neuron reconstruction at the whole-brain scale. To account for topological correctness beyond geometric distance similarity, we introduce a structure-aware metric based on fiber prediction. To further achieve complete neuron reconstruction across the entire brain, we develop a brain-wide neuron tracing framework that extends arbitrary local reconstruction methods to the whole-brain scale through an iterative local-to-global process. Using this benchmark, we provide the first structure-aware comparison of mainstream methods for local neuron reconstruction and further evaluate their performance in brain-wide reconstruction. Our results underscore the importance of structure-aware evaluation and the need for more robust methods for complete neuron reconstruction.

0.32

From Pixel Generation to Topological Inference: Structural Dual Super-Resolution for Trustworthy Cross-Physical-Domain Trabecular Morphology Learning

cs.CV ·2026-09-28 ·Fan Zhang, Yi Zhang, Yuhui Dong, Ling Wang, Xin Xu
similarity 0.55
Abstract · 23 pages,7 figures

Clinical CT and UHRCT cannot resolve individual trabeculae, whereas synchrotron radiation microCT (SRuCT) provides high-resolution references but is not applicable for in vivo imaging. The two domains differ by a 32x resolution gap, are only coarsely paired, and exhibit severe physical differences including partial volume effects, noise, and artifacts. Existing super-resolution networks and pretrained-prior methods (GLEAN/StyleGAN2, Stable SR/LDM) underperform because they target pixel generation---diverse details and SSIM/PSNR---and do not model these physical differences. Pixel generation for a 32x resolution gap is intrinsically ill-posed. We propose a paradigm shift from pixel generation to topological inference: deterministically predicting invariant microstructures from macro-scale low-resolution inputs, evaluated by morphological parameters. The core of our 2D morphology learning lies in training on 2D slices while evaluating on 3D morphological parameters, ensuring that the learned representations capture true three-dimensional trabecular topology rather than 2D pixel statistics. We realize this paradigm via structural dual super-resolution, coupling forward physical degradation (micro-to-macro) with inverse structural inference (macro-to-micro) through structural duality constraints. The method is an end-to-end, few-shot, compact structural dual network (SDN), comprising a bidirectional modeling network, a multi-scale structural consistency discriminator, and four structural duality constraints. On the test set, SDN achieves morphological parameters largely consistent with SRuCT across six metrics, with SSIM reaching 0.8. Trained on 3.2 um SSRF data, the model generalizes well to 3.25 um isotropic BSRF data from an independent source, validating cross-source generalization and confirming trustworthy structural inference rather than pixel generation.

0.19