CS Paper Radar

A Joint 2D-3D Statistical Shape Model for Orthopedic Reconstruction

Florence Dell'Aniello Picard, Pranav Poudel, Nairouz Shehata, Frédéric Lavoie, Herve Lombaert

cs.CV ·submitted 2026-09-08 16:46 UTC · v1
publishedcode/data

Abstract

Three-dimensional femoral reconstruction from radiographs supports surgical planning, implant sizing, and post-operative follow-up, but remains ill-posed as X-ray projections discard depth information. Existing methods often incorporate a 3D statistical shape model (SSM) as a shape prior to guide reconstructions toward anatomically plausible shapes, relying on iterative 3D-to-2D projection matching. Yet, these approaches are computationally expensive and constrain their SSM to a single dimensionality, leaving the statistical relationship between 2D observations and 3D geometry largely unexploited and unexplored. We instead propose a joint 2D-3D SSM that explicitly captures the co-variation between 2D and 3D segmentations in a shared latent space. During training, 2D and 3D segmentations are registered to a common 3D template and its corresponding 2D projections, and the resulting stationary velocity fields are jointly decomposed using principal component analysis (PCA). This joint modeling allows the 2D-to-3D mapping to be learned directly from data rather than computing correspondences at inference time. For unseen subjects, the 3D shape is recovered directly by lifting the 2D latent coordinates to the 3D PCA subspace, thereby eliminating the need for iterative 3D-to-2D projection. Experiments on NMDID demonstrate that the proposed joint 2D-3D SSM outperforms a widely-used 3D-only SSM baseline while achieving inference approximately 4 times faster, at under 3 seconds per subject. The code is available at: https://github.com/florence-dellaniello-picard/joint2d3d-ssm.

Comment
Accepted to MICCAI Workshop on Shape in Medical Imaging (ShapeMI)

Closest papers

Nearest neighbours by meaning across the whole index.

THA-Flow Generative Model: Prosthesis Geometry Prediction from Preoperative CT

cs.CV ·2026-08-26 ·Yiping Wang, Jie Li, Jingyu Shen, Liao Wang
similarity 0.69
Abstract · 17 pages, 7 figures, 2 tables

Preoperative planning for total hip arthroplasty (THA) is commonly framed as selecting a single prosthesis configuration and placement for a patient's osseous anatomy. In practice, however, the same anatomy may admit several clinically reasonable solutions, making planning inherently a one-to-many problem that is better represented by a conditional probability distribution. We present THA-Flow, a conditional flow-matching model that generates three-dimensional prosthesis geometry directly from preoperative CT. Separate AutoencoderKL models compress preoperative bone anatomy and prosthesis geometry, while a three-dimensional UNet learns a rectified flow from Gaussian noise to the prosthesis latent space under spatial bone conditioning and optional structured prosthesis parameters. The retrospective cohort comprised 1,355 hips from 1,149 patients undergoing primary THA. Following rigid registration of postoperative CT to preoperative CT, the actual postoperative prostheses were transformed independently according to the pelvic and femoral registrations and represented as a dual-channel truncated signed distance field. The prosthesis autoencoder achieved a peak signal-to-noise ratio of 47.11 dB and a structural similarity index of 0.9964 on the validation set. Complete acetabular and femoral geometries were generated across seven major stem models representing 93.4% of the cohort. Repeated bone-conditioned sampling preserved component position, alignment, and the principal bone-prosthesis interfaces while allowing limited local geometric variation. To our knowledge, THA-Flow represents the first application of generative AI to three-dimensional surgical planning for THA.

0.28

XPos3R: Cross-Modal Transformer for Intraoperative 2D/3D Registration

eess.IV ·2026-09-09 ·Shiyan Su, Ruyi Zha, Hongdong Li, Xuelian Cheng, Zongyuan Ge
top venue similarity 0.68
Abstract · Accepted to ECCV 2026

Intraoperative 2D/3D registration, which aligns live X-ray images with preoperative volumes, is essential for image-guided interventions. Previous regression-based methods suffer from limited generalization, thus requiring time-consuming patient-specific retraining. Inspired by recent geometry foundation models such as DUSt3R, we propose XPos3R, a generalizable pose regression method that eliminates preoperative preparation. Unlike existing geometry models designed for homogeneous inputs, XPos3R extends this paradigm to multi-modal inputs, namely 2D X-rays and 3D volumes. Specifically, we introduce an asymmetric encoder-decoder architecture that improves cross-modal feature alignment while maintaining computational efficiency. To scale training under limited medical data, we adopt an anatomy-specific data curation strategy and construct million-scale synthetic datasets. Evaluated on real-world benchmarks, a single pretrained XPos3R surpasses patient-specific methods in both accuracy and robustness. With test-time optimization completed in seconds, it further reduces the 3D error to <4 mm and the reprojection error to <1 mm. The strong generalization, accuracy, and efficiency of XPos3R highlight its clinical potential, while its asymmetric framework may inspire broader cross-modal vision geometry tasks.

0.47

ZODIAC: Zero-shot Octree-based Diffusion for Anatomical Completion

cs.CV ·2026-08-25 ·Miruna-Alexandra Gafencu, Vlad Bratulescu, Yordanka Velikova, Mohammad Farid Azampour, Nassir Navab
code/data similarity 0.65
Abstract

Recovering the full 3D spine anatomy from intraoperative ultrasound is an ill-posed inverse problem, as the complete structure must be inferred from incomplete and noisy observations. Acoustic occlusions and limited field of view create large unobserved regions, while view-dependent artifacts lead to variability in expert annotations of the visible anatomy. Current supervised ultrasound shape completion methods rely on synthetically generated incomplete-complete paired data to learn conditional mappings under a predefined distribution of simulated occlusions. However, real intraoperative occlusions do not necessarily follow this distribution, which can limit generalization to patient data. As a result, accurate and robust completion from noisy partial observations remains an unsolved problem. We propose a zero-shot shape completion framework that reconstructs the entire lumbar spine from partial ultrasound observations without relying on simulated training data. To accommodate unseen and irregular patterns of missing structures, we introduce blended completion, a mechanism that integrates the learned anatomical prior with incoming partial geometry at inference time. The method learns a generative diffusion prior over full anatomical shapes represented in an adaptive octree structure, enabling efficient modeling of the complete spine in a single forward pass. Validation on phantom and volunteer data shows that decoupling completion from a predefined corruption distribution improves generalisation under real occlusions, outperforming a fully supervised variant by 22% on HD95 completion error. Code and data are available at https://github.com/miruna20/ZODIAC.

0.46

FleXray: Universal Clinical X-ray Segmentation

cs.CV cs.AI ·2026-09-22 ·Victor Ion Butoi, Vivek Gopalakrishnan, John V. Guttag, Adrian V. Dalca, Neel Dey
similarity 0.64
Abstract · 35 pages, 12 figures, 10 tables. Code, models, data, and a browser-based demo at https://flexray.csail.mit.edu

X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray collapses 3D anatomy into a 2D projection, causing structures to overlap and anatomical boundaries to be ambiguous, even to experts. As a result, labeling X-ray databases for training general-purpose segmentation systems is impractical, leaving morphometric and functional X-ray analysis confined to narrow anatomical regions and applications. To this end, we present FleXray, a generalist model for anatomical segmentation across the entire body in clinical X-rays. Instead of curating large, manually annotated X-ray datasets, we build a scalable, physics-based generative X-ray data engine. Using existing 3D whole-body CT segmentation datasets and generative image-editing models, we simulate fully-annotated 2D X-rays with diverse appearances, physiological properties, and imaging geometries. Trained on these simulations, FleXray accurately segments 60 anatomical structures across unseen research datasets and in-the-wild X-rays. We further show that FleXray makes X-rays directly amenable to quantitative analysis, enabling automated measurements for disease grading, robust navigation during X-ray-guided interventions, and data-efficient learning of pathological targets. We release the model, code, a full-body X-ray segmentation dataset, and a local, easy-to-use browser-based tool at https://flexray.csail.mit.edu .

0.27

Topology-Unified 2D Pose Estimation across Intact, Residual and Prosthetic Limbs

cs.CV ·2026-08-13 ·Tianye Qi, Tengyue Zhang, Jiaying Ying, Tianqing Zhu, Xin Yu
benchmark similarity 0.64
Abstract · 14 pages, 7 figures, 7 tables

Driven by the availability of large-scale datasets, Human Pose Estimation (HPE) plays a critical role in numerous downstream tasks. However, mainstream benchmarks exhibit severe representation bias, predominantly featuring able-bodied individuals. While a few pioneering datasets have attempted to address limb differences, their annotation protocols fail to generalize, struggling to represent specialized mechanical structures like running blades or unprosthetized residual limbs. To bridge this gap, we introduce ProPose, a large-scale benchmark featuring a novel annotation protocol that unifies the topological representation of biological limbs, diverse prostheses, and physical absences within a single framework. Because real-world prosthetic images are inherently scarce and exhibit extreme long-tail distributions, we design a Real-to-Synthetic data expansion pipeline to explicitly synthesize and expand the underrepresented cases. However, simply training existing models on this enriched dataset often leads to suboptimal solutions, as they estimate each keypoint independently and might hallucinate non-existent joints on mechanical structures. To resolve this, we propose ProLoss, a structure-aware objective that enforces keypoint dependencies within a single limb to prevent unrealistic limb predictions. Extensive experiments demonstrate that our approach improves the classification accuracy of long-tail prosthetic joints by 2% to 6% without compromising spatial coordinate localization performance. This work sets a foundation for inclusive pose estimation, unlocking new possibilities for understanding the interactions between human bodies and assistive devices.

0.40

Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction

cs.CV cs.AI ·2026-08-18 ·Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu +3 more
similarity 0.64
Abstract

X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path. Reconstructing a CT volume from only a few X-ray views is therefore severely ill-posed, as the projections collapse depth information and leave 3D locations of anatomical regions and their corresponding intensity distributions highly entangled and ambiguous. We observe that once the spatial organization of anatomical regions is established, estimating their CT intensities becomes substantially more tractable. Motivated by this, we propose LiftXR, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction. Specifically, a layout lifter first generates a 3D anatomical layout from bi-planar X-rays, providing spatial guidance for an intensity renderer to reconstruct a CT volume. An anatomical parser then performs volumetric perception on the reconstruction, exploiting its spatially resolved boundary and intensity cues to recover a refined anatomical layout. This transition from projection-conditioned layout generation to reconstruction-conditioned anatomical perception allows the parsed layout to provide feedback for region-specific intensity calibration. Extensive experiments on two public datasets demonstrate that LiftXR consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art. Moreover, the reconstructed CT achieves superior performance in external downstream segmentation, indicating improved anatomical fidelity. Code will be released.

0.22

Registration is a Representation Problem: Solving Whole-Body PET/CT Registration

cs.CV cs.LG ·2026-10-13 ·Neel Dey, Adrian V. Dalca
publishedbenchmarkcode/data similarity 0.63
Abstract · Technical report. First place winning solution for the MICCAI Learn2Reg 2026 PSMAReg challenge. Code and volumetric visualizations are avail…

Raw image intensities are a poor surrogate for similarity across images in correspondence problems. Further, while auxiliary segmentation labels can provide semantic identification and improve matching, they can assign only coarse identities to fine-grained anatomy and often cover only a subset of structures, particularly in whole-body settings. We present an approach that instead establishes correspondence using complementary representations of anatomy and demonstrate its utility for longitudinal whole-body PET/CT registration in the Learn2Reg 2026 PSMAReg Challenge. We use our 3D foundation model, anatomix, to derive fine-grained, per-voxel semantic representations that are consistent across volumes and further employ off-the-shelf segmentation models to obtain coarse anatomical identities. Together, these representations drive a GPU-accelerated iterative registration solver (FireANTs) in a hybrid multistage framework: the first stage estimates alignment from dense multi-channel features, after which a second refines the deformation using both anatomix- and segmentation-based losses. Lastly, because registration should not introduce non-biological tumor volume changes across time, we develop lesion-specific, component-wise volume preservation schemes. Without any task-specific training, our system placed first on the PSMAReg Challenge leaderboard. Code and interactive visualizations are available at https://www.neeldey.com/reps-for-reg.

0.31

REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models

cs.CV ·2026-11-06 ·Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi
top venue similarity 0.63
Abstract · 32 pages, 6 figures, Accepted to NeurIPS 2026 ED Track

Evaluation of 3D medical foundation models is typically dominated by downstream task scores, which entangle representation quality with adaptation choices. This is especially critical in volumetric imaging, where spacing and anisotropy can substantially alter image statistics while the anatomy itself remains unchanged. We therefore introduce \textbf{REFORM-3D}, a \textbf{R}epresentation-centric \textbf{E}valuation \textbf{F}ramew\textbf{OR}k for benchmarking frozen 3D medical vision foundation \textbf{M}odels across three questions: Acquisition Robustness, asking whether features remain stable when spacing varies while anatomy is fixed; Cross-Modal Anatomical Alignment, asking whether labeled anatomical structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, asking whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. These are also pretraining questions, because what a 3D encoder learns depends on how volumes are geometrically presented during self-supervised pretraining. We further introduce Med3DINO encoder family, pretrained on $62.6$K unlabeled MR, CT, PET, CTA, and CBCT volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling. Across Med3DINO and heterogeneous external encoders, REFORM-3D reveals module-specific strengths rather than a single model ordering. Within the controlled Med3DINO comparison, voxel-relative sampling yields lower embedding drift, whereas spacing-aware resampling favors anatomical transfer; semantic-transfer advantages depend on the dataset and feature type. Project link: \href{https://endarzboy.github.io/reform3d-website/}{\highlightLR{REFORM-3D}}.

0.50