CS Paper Radar

Learning to Adapt and Calibrate: Score Distribution Alignment for Few-Shot Uncertainty Prediction in Medical VLMs

Xuan Cuong Ngo, Ngan Le

cs.CV ·submitted 2026-09-09 15:32 UTC · v1

Abstract

Uncertainty estimation for medical vision--language models (VLMs) using conformal prediction has gained increasing attention due to its distribution-free coverage guarantees. However, standard conformal prediction relies on exchangeability between calibration and test data and typically requires a sufficiently large calibration set to obtain reliable coverage. These assumptions are difficult to satisfy in few-shot transfer settings, where only a small labeled support set is available to adapt a pretrained VLM to a new medical task, while an unlabeled query set is used for evaluation. Supervised fine-tuning on the support set changes the model parameters and consequently shifts the nonconformity score distribution, breaking exchangeability between calibration and query samples and leading to unreliable coverage under distribution shift. Existing transductive conformal adaptation methods often preserve validity by avoiding supervised updates. While this helps maintain conformal assumptions, it underutilizes the scarce labeled support data and limits task adaptation, which is the primary objective in few-shot learning. In this setting, conformal prediction should serve as an uncertainty estimation layer that supports the adapted model, rather than preventing adaptation itself. To this end, we propose AlignCP, a framework that reconciles supervised few-shot adaptation with conformal uncertainty estimation under non-exchangeability. AlignCP learns a reweighted calibration distribution that reduces the score-level discrepancy between the labeled support set and the unlabeled query set. By aligning the one-dimensional nonconformity score distributions, AlignCP aims to close the coverage gap induced by adaptation without requiring query labels.

Closest papers

Nearest neighbours by meaning across the whole index.

Conformal Risk Minimization for Semi-Supervised Domain Adaptation via Optimal Transport

cs.LG ·2026-08-24 ·Manos Giannopoulos, Yi Shen, Michael M. Zavlanos
similarity 0.74
Abstract · 18 pages, 2 figures, 6 tables

In high-stakes healthcare applications, machine learning models are frequently trained on data from one patient population and deployed on another, creating a distribution shift that degrades both accuracy and reliability. Semi-Supervised Domain Adaptation (SSDA) addresses this by leveraging labeled data from some source domain to improve model performance on a target domain where labels are scarce. However, existing SSDA methods optimize primarily for point-prediction accuracy and offer no principled uncertainty quantification --- a prerequisite for clinical trust. Conformal Prediction (CP) can address this limitation by providing prediction sets with rigorous, distribution-free coverage guarantees. However, applying CP post-hoc to a pre-trained model can yield prohibitively large prediction sets, as SSDA pre-training methods do not account for the nonconformity score geometry that determines conformal set size. Conformal Risk Minimization (CRM) has been used to resolve this issue in the fully supervised setting by integrating the CP objective directly into model training, but it requires a large labeled dataset to compute nonconformity thresholds during training, precisely the data that is scarce in the SSDA regime. We propose an end-to-end framework that integrates CRM into the SSDA training objective, enabling effective CRM in the limited-labeled-target-data regime. The key idea is to utilize Optimal Transport (OT) to generate pseudolabels for unlabeled target instances, providing the additional training signal needed by CRM to operate using only a small labeled target set. This results in a model jointly optimized for domain invariance and conformal efficiency, producing prediction sets that are compact, coverage-valid, and support domain-specific constraints such as excluding mutually contradictory diagnoses in skin lesion classification.

0.11

Uncertainty of Vision Medical Foundation Models

cs.LG ·2026-08-31 ·Haoxu Huang, Narges Razavian
similarity 0.70
Abstract

Accurate uncertainty estimation is essential for machine learning systems de- ployed in high-stakes domains such as medicine. Traditional approaches primarily rely on probability outputs from trained models (point predictions), which provide no formal guarantees on prediction coverage and often require additional calibra- tion techniques to improve reliability. In contrast, conformal prediction (region prediction) offers a principled alternative by generating prediction sets with finite- sample validity guarantees, ensuring that the ground truth is contained within the set at a specified confidence level. In this study, we explore the impact of pre-training approach, dataset scale and domain on both point and region-level uncertainty quantification, by studying domain-specific vision medical foundation models vs. general domain vision foundation models. We conduct a comprehensive evaluation across foundation models trained on retinal, histopathological, and Chest X-Rays data, applying various calibration techniques. Our results demonstrate that (1) pre-training on higher-quality domain-specific datasets along with self-supervised learning leads to better-calibrated point predictions than general domain pre-training, (2) stan- dard re-calibration methods alone cannot fully mitigate uncertainty discrepancies across models trained on different data sources, (3) domain-specific foundation model can lead to more efficient conformal prediction. These findings highlight the importance of careful model selection and the inte- gration of both point and region prediction to enhance the reliability and trust- worthiness of medical AI systems. Our work underscores the need for a holistic approach to uncertainty quantification in recent development of medical vision foundation model, ensuring robust and interpretable AI-driven decision-making.

0.06

Scaling Full Conformal Image Classifiers

cs.LG cs.CV ·2026-09-29 ·Julio Silva-Rodríguez, Ender Konukoglu
publishedcode/data similarity 0.69
Abstract · NeurIPS 2026. Code: https://github.com/jusiro/T-FCP

Conformal prediction provides set-valued predictions with distribution-free coverage guarantees, making it attractive for high-stakes image classification. However, split conformal prediction is data-inefficient, while full conformal prediction (FCP), despite its stronger statistical efficiency, is computationally prohibitive at scale because it requires candidate-specific model refits at test time. We address this limitation by leveraging zero-shot vision-language models (VLMs) to guide scalable FCP in large label spaces. We introduce Targeted Full Conformal Prediction (T-FCP), which uses a lightweight inductive conformal predictor to prune unlikely labels and applies FCP only to the remaining candidates, reducing computation while retaining the formal guarantee of the combined conformal procedure. We further propose Stabilized Online LDA (SO-LDA), an efficient VLM adaptation solver based on rank-one inverse-covariance updates. Across multiple benchmarks, including ImageNet, T-FCP enables practical full-conformal image classification with modest test-time overhead, yielding efficient prediction sets and more stable empirical coverage than split conformal alternatives.

0.39

Adaptive Conformal Redistribution for Inter-class Transitional Uncertainty in Medical Image Classification

cs.CV cs.AIcs.LGstat.CO+1 ·2026-09-10 ·Saibal Ghosh, Samarup Bhattacharya, Sanjoy Kumar Saha, Umapada Pal, Tapabrata Chakraborti
benchmarkcode/data similarity 0.69
Abstract

Medical image classification is frequently complicated by transitional categories whose feature distributions overlap those of adjacent classes, producing ambiguous decision boundaries. Conformal prediction returns uncertainty-aware prediction sets, but these are not directly actionable in clinical screening, where a single decision is required. This work proposes adaptive conformal redistribution (AdaConRed), a label-free post-conformal decision rule that converts ambiguous prediction sets into refined class assignments. A five-stage pipeline is developed. Vision-language generative augmentation addresses minority-class scarcity; a frozen DermFoundation encoder provides embeddings; a lightweight multi-layer perceptron performs classification; an entropy-modulated, margin-aware nonconformity score constructs adaptive prediction sets; samples predicted as transitional with multi-label sets are reassigned to the most probable alternative class within the set, using only model outputs at inference. Evaluation uses the OSCC oral lesion and ISIC skin lesion benchmarks at a miscoverage level of 0.2. On the 3-class OSCC benchmark, overall accuracy improves from 73.54% to 77.38%, with oral cancer accuracy rising from 64.29% to 82.14% and benign accuracy from 56.57% to 70.20%. Reassignment of transitional samples reduces OPMD accuracy from 84.78% to 80.16%, consistent with the asymmetric cost of missed malignancy. On ISIC, overall accuracy improves from 85.83% to 87.19%, melanoma accuracy rising from 66.04% to 68.34%. AdaConRed outperforms LAC, APS and RAPS under an identical backbone and redistribution rule. Conformal prediction can be extended beyond uncertainty quantification toward actionable decision support where transitional disease categories are present, with gains concentrated in the clinically critical malignant categories. Code repository: https://github.com/saibal436ghosh/AdaConRed.

0.38

ENCP: Episode-Normalized Conformal Prediction for Vision-and-Language Navigation

cs.LG cs.AIcs.RO ·2026-09-15 ·Vicky Feliren, A. Taufiq Asyhari, Muhamad Risqi U. Saputra
similarity 0.67
Abstract · 8 pages, 5 figures

Uncertainty estimation for Vision-Language-Navigation (VLN) models is a critical task since it can help identify ambiguous and unreliable predictions, enabling agents to make safer navigation decisions. As one of the most advanced uncertainty estimation frameworks, conformal prediction (CP) offers a promising approach for uncertainty estimation in VLN. However, given that VLN agent requires a sequence of steps, standard calibration in conformal prediction fails to provide coverage guarantee it promises over a dependent, variable-length VLN episode. To this end, we propose Episode-Normalized Conformal Prediction (ENCP), which rescales a nonconformity score by the policy's residual confidence and calibrates one maximum score per episode. Under exchangeable calibration and test episodes, this construction covers the ground truth at every step with probability at least $1 - α$, while allowing dependence among steps within an episode. Across four VLN policies and three nonconformity scores on R2R and REVERIE dataset, ENCP meets all reported empirical step-coverage targets on the seen-to-unseen evaluation. These results demonstrate that ENCP can provide model-agnostic uncertainty estimates, which might be useful for determining when a VLN agent should defer to a more capable predictor, including human assistance.

0.30

Beyond Accuracy: Benchmarking Uncertainty Quantification in Retinal Disease Screening

eess.IV ·2026-11-17 ·Mahvash Jebeli, Mohammad Eslami, Nazlee Zebardast, Lucia Sobrin, Tobias Elze
benchmarkdataset similarity 0.67
Abstract

Reliable uncertainty quantification (UQ) is essential for evaluating retinal AI systems beyond classification accuracy, yet it remains unclear whether existing UQ strategies generalize across diseases, model architectures, and reliability criteria. We introduce a large-scale, multi-disease benchmark comprising over $242,000$ fundus photographs from $32$ datasets covering diabetic retinopathy, age-related macular degeneration, and glaucoma. We evaluate six representative UQ strategies across three Vision Transformer configurations, assessing discrimination, probabilistic calibration, selective prediction, and conformal prediction-set coverage. Our findings reveal no universally superior model or UQ strategy: methods that improve reliability in one disease or architecture may underperform in another, while improvements in discrimination, calibration, and selective prediction do not necessarily align. Notably, computationally intensive methods do not consistently outperform simple confidence scores, and domain-specific foundation models and calibration-oriented loss functions do not guarantee greater reliability. In contrast, conformal prediction provides a complementary framework for achieving near-nominal marginal prediction-set coverage across diverse settings, subject to its statistical assumptions. These findings challenge universal UQ recommendations and highlight the need for disease-specific, model-specific, and multidimensional reliability evaluation before clinical deployment. We release standardized dataset splits, trained checkpoints, evaluation code, and an interactive research demonstration to support reproducible benchmarking.

0.06

Conformal Prediction under Exponential-Tilt Joint Shift

cs.LG stat.MLstat.ME ·2026-09-25 ·Seungjin Choi
similarity 0.66
Abstract · 23 pages

Conformal prediction can lose coverage when the data distribution changes after deployment. We study adaptation using labeled source data and unlabeled target inputs, allowing both the input distribution and its relationship with outcomes to change. We use Exponential Tilt Reweighting Alignment (ExTRA), introduced for classification by Maity et al. (2023), to estimate structured distribution shifts. We compare using its estimated weights in conformal calibration with additionally tilting the source predictive distribution. Shared learned predictors, estimated weights, calibration samples, and test observations isolate the effect of tilting. Existing theory gives both procedures target coverage with true weights and a common coverage bound with estimated weights. Identification calculations and an analysis of how scoring interacts with weight estimation error help explain why their performance can nevertheless differ. In a synthetic regression setting where the assumed models match the data-generating process and target inputs are informative about the shift, tilting reduces mean set length by about $30\%$ relative to weighting alone, with both methods attaining coverage near nominal. Tilting can instead cause substantial coverage losses in synthetic classification and in regression when target inputs provide little information about the response shift. Real-data experiments also show no consistent benefit. Good coverage from weighted calibration alone does not ensure that adding predictive tilting will preserve coverage. Deciding when to apply this additional adjustment using only source labels and target inputs remains an open problem.

0.41

MVC-Bench: Benchmarking Calibration of Medical Vision-Language Models

cs.CV ·2026-08-27 ·Ashshak Sharifdeen, Shihab Aaqil Ahamed, Ufaq Khan, Muhammad Akhtar Munir, Sujair Ibrahim +4 more
top venuebenchmark similarity 0.66
Abstract · Accepted in EMNLP 2026 Findings

Reliable evaluation of vision-language models (VLMs) and medical vision-language models (Medical-VLMs) requires calibrated confidence, particularly under realistic clinical conditions. However, existing efforts mainly focused on improving accuracy, leaving calibration in the medical domain underexplored. To this end, we propose MVC-Bench, a calibration-centric benchmark for medical image classification with VLMs and Medical-VLMs. MVC-Bench assesses the calibration across three axes: (i) robustness to modality, backbone, and domain shift (ii) effectiveness of calibration strategies and prompt-tuning methods (iii) stability under prompt-template and random-seed variations. The benchmark covers eight different backbones, three medical modalities, including fundus imaging, histopathology, and chest X-ray under in-domain and domain shift settings. It compares post-hoc calibration, train-time calibration, and zero-shot inference methods, together with six prompt-tuning methods. Across more than 1638 controlled experiments, we report accuracy and Expected Calibration Error (ECE) as primary metrics, and further report results with complementary calibration measures, including Maximum Calibration Error (MCE) and Adaptive Calibration Error (ACE). We further investigate the underlying causes of miscalibration in VLMs and Medical-VLMs and propose a simple train-time calibration method, Multi-Class Margin (MCM) regularization, which achieves lowest ECE on 10 out of 12 settings in in-domain and remains competitive under domain shifts. Collectively, MVC-Bench provides a structured evaluation framework and actionable guidance for improving calibration in safety-critical medical workflows.

0.58