CS Paper Radar

Can LLMs Follow Medical Expert Logic? A Benchmark for Hierarchical Logical Consistency in Risk-of-Bias Assessment

Jiayu Huang, Zichen Tang, Qianhui Ling, Zemin Kuang, Haihong E

cs.AI ·submitted 2026-09-10 07:46 UTC · v1
top venuebenchmark

Abstract

Evidence-based medicine demands strict logical consistency, yet current evaluations of large language models (LLMs) prioritize superficial label matching over genuine reasoning. We introduce LogiMed-RoB, a benchmark grounded in Cochrane Risk of Bias (RoB) 2.0 expert logic, comprising 860 randomized controlled trials (RCTs) and 14,820 queries. It evaluates models under the Hierarchical Logical Consistency (HLC) framework across four dimensions: Atomic Consistency, Domain Consistency, Aggregation Consistency, and Evidential Faithfulness. Experiments on 10 state-of-the-art LLMs reveal a catastrophic Error Compounding Effect: despite the top model reaching 98.88% Atomic Consistency, its end-to-end consistency collapses to 45.13%, with several open-weight architectures plummeting to nearly 0%. We further uncover a systematic evidence-reasoning gap: even when models retrieve high-quality evidence, they fail to deduce correct outcomes in 18.63-40.05% of cases, while Blind Guess Rates reach 48.28%. LogiMed-RoB demonstrates that high outcome accuracy can conceal critical reasoning flaws, underscoring the necessity of white-box logical verification for clinical deployment.

Comment
Accepted to EMNLP 2026 Main Conference

Closest papers

Nearest neighbours by meaning across the whole index.

An evidence-traceable benchmark of clinical reasoning in large language models

cs.CL ·2026-11-10 ·Zhiqun Zhao, Xiaodong Yang, Bruce Gu, Ming Li, Yi Fu +11 more
benchmark similarity 0.69
Abstract · 25 pages, 8 figures, 4 tables. Zhiqun Zhao, Xiaodong Yang and Bruce Gu contributed equally. Corresponding authors: Zheng Wang, Haiquan Lu an…

Benchmark scores for medical large language models (LLMs) are difficult to interpret when scoring criteria cannot be traced to clinical evidence. Here we developed Med Evidence Bench (MEB; https://www.medevidencebench.org.cn/), comprising 1,536 physician-constructed items across three levels: guideline knowledge, standardized clinical scenarios and real-world laboratory scenarios. Each criterion stating a medical claim is linked to a versioned source-text span. Across ten LLMs, the Evidence Trace Score (ETS) was 0.975-0.997 for guideline knowledge, 0.292-0.658 for standardized scenarios and 0.182-0.447 for real-world scenarios, and rankings varied across levels. For real-world scenarios, scores for identifying clinical information (mean, 0.770) exceeded those for matching evidence (0.165) or formulating recommendations (0.160). On 1,296 criterion-level judgments, automated grading agreed with the majority vote of three physicians (macro-F1, 0.930; 95% confidence interval, 0.915-0.945), although agreement was lower for evidence application. These findings from Chinese-language materials indicate that guideline recall does not ensure patient-specific evidence use and do not establish clinical effectiveness.

0.25

Verifiable Logic in Medical LLMs: A Critical Review of Agentic Clinical Reasoning Optimization and Neuro-Symbolic Grounding

cs.CL cs.AIcs.CYcs.LG ·2026-11-19 ·Youssef ElNahas, Adel Ammar, Soumaya Chaffar, Wadii Boulila
position similarity 0.68
Abstract

Clinical large language models are usually judged by whether the final answer is right. Yet a model can reach a fluent, plausible output through invalid reasoning that static benchmarks do not detect, and confident hallucination, causally invalid inference, and spurious demographic shortcuts can pass conventional evaluation. This critical review covers four paradigms in turn: how clinical hallucination arises and why static metrics miss it; the agentic hallucination cascade, in which multi-agent and tool-augmented systems propagate and amplify early reasoning errors; process reward modeling as step-level supervision; and neuro-symbolic grounding, in which formal logic engines, ontology reasoners, and knowledge graphs place verifiable constraints on neural output. Within their encoded domains, systems with symbolic veto layers offer guarantees that hold relative to their encoded knowledge, and they report large gains on the safety measures they use. These results come from single studies, mostly in simulated or small-sample settings, and are not directly comparable with neural baselines. Process reward models remain bounded by the statistics of their training data. We propose a conceptual framework that maps each agentic failure mode to a symbolic intervention point, and we argue that clinical AI safety depends substantially on system architecture. Because current regulation emphasizes performance and does not require verification of reasoning steps, we argue that responsible certification should also audit reasoning trajectories alongside accuracy on static benchmarks.

0.12

Can LLMs Value the Right Evidence? Evidence-Value Misalignment in Dynamic Medical Diagnosis

cs.CL ·2026-09-28 ·Kehua Feng, Yunsheng Lu, Yitong Qiao, Tiantian He, Lei Liu +3 more
similarity 0.67
Abstract · 33 pages, 10 figures

A correct diagnosis reached from insufficient or misleading evidence can pose a clinical hazard, yet outcome-based accuracy may reward such lucky guesses. We call this mismatch between diagnostic decisions and the value of available evidence Evidence-Value Misalignment (EVM). To disentangle evidential grounding independently from diagnostic accuracy, we introduce MedEVM, a dynamic benchmarking environment comprising 1,050 cases across 24 disease systems. Observations arrive turn by turn, requiring models to continuously calibrate its decision by deciding whether to wait for more evidence or submit a diagnosis. Across 9 LLMs, four interesting patterns are observed. (1) Miscalibrated evidence tracking. Making a diagnosis often fails to calibrate evidence sufficiency, even in more capable models, and even worsens in reasoning mode. (2) Misaligned diagnosis submission. Confidence in the correct diagnosis often fails to ensure timely submission despite sufficient evidence. (3) Evidence order matters. Reordering the same evidence changes diagnoses even when model confidence remains similar. (4) Misleading evidence remains influential. Added misleading evidence redirects diagnoses even after prior evidence becomes sufficient. We further verify that EVM predicts errors and that preventing premature submission improves accuracy. These findings motivate Evidence-Verified Diagnosis Harness (EVD-Harness). It decouples diagnosis generation from submission through an offline Contrastive Diagnostic Wiki and three online control stages, namely observation management, proposal and witness verification, and diagnosis submission control. Across five LLMs, EVD-Harness improves accuracy by 12.0--51.1 percentage points while mitigating EVM-related failures. Our results demonstrate that verifying evidential support before submission can make diagnostic decisions more reliable.

0.26

Where Does Retrieval-Based Open-Ended Evaluation Fail? Automatic Taxonomy Induction from Long-Form Medical Answer Factuality Verification

cs.CL cs.IR ·2026-09-24 ·Heyuan Huang, Jirui Dai, Alexandra DeLucia, Sonal Joshi, Mahsa Yarmohammadi +3 more
top venue similarity 0.67
Abstract · All experiments were done before May 2026 (also all corpus knowledge cutoff date). Accepted as an Oral paper (Best Paper Finalist) at NeurIP…

Retrieval-based factuality evaluation, where LLM-generated claims are verified against evidence from authoritative medical corpora, has become the dominant paradigm for scalable hallucination detection in high-stakes clinical settings. Despite the urgency of reliable and transparent medical fact verification, most systems measure performance with aggregate metrics like F1, which obscure where and why failures occur. Existing RAG diagnostics require gold answers or annotated gold evidence, neither of which exists in this regime. We introduce two comprehensive taxonomies, grounded in a case study on the open-ended MedExpert dataset and 3 closed-ended datasets, decomposing failures into retrieval-stage errors along five quality dimensions, and verifier-reasoning errors into six consecutive steps. We adapt an automatic pattern induction pipeline using LLM-as-Judge to label evidence quality and classify verifier reasoning errors at scale, and then stress-test our findings across 4 retrieval methods and 6 frontier verifier models. Our analysis reveals that scaling model size, adding reasoning effort, expanding to authoritative web sources, and applying medical fine-tuning do not resolve these failure modes, demonstrating that they represent fundamental limitations of the retrieve-then-verify paradigm in open-ended medical settings rather than artifacts of outdated systems. We release our code and data at https://anonymous.4open.science/r/Medical_RAG_eval-4AB5 for the full reproducibility of our results.

0.36

Auditing Escalation Reliability in Healthcare LLM Agents: A Perturbation-Controlled Benchmark of Workflow-State Failures

cs.AI cs.CL ·2026-10-15 ·Zihao Zheng, Junyi Yao, Baichuan Li, Jiayu Long
benchmark similarity 0.67
Abstract · 8 pages, 5 figures

Trustworthy biomedical AI requires reliable action selection when evidence is missing, stale, conflicting, or late, not only accurate answers on static inputs. We instantiate an episode-level evaluation protocol as 400 synthetic healthcare workflow episodes: 40 hand-authored semantic seeds across four task classes, two surface parameterizations, and five controlled variants, scored on ANSWER/ASK CLARIFICATION/ABSTAIN/ESCALATE under a pre-declared 5:1 missed-versus-unnecessary escalation cost. Reference actions are single-author study-policy labels, not clinician-adjudicated ground truth. Across five open-weight configurations (1.7B--9.7B), clean decision accuracy reaches 0.97, yet uncertainty-prompted models miss 32--97% of required escalations. The stronger 9.7B configuration narrows but does not remove the gap, falling from 0.97 clean accuracy to 0.78 under conflict. Verbalized confidence is inconsistent (ECE 0.10--0.54; failure AUROC 0.48--0.77), and a development-tuned confidence-only policy yields no utility gain. A transparent workflow-aware controller improves 5:1 utility for every model and reduces missed escalations to 0.12--0.24, at specificity 0.83--0.93. However, a 30-concept lexical stress test reduces each rule detector's recall from 1.00 on trigger phrases to 0.00 on unseen paraphrases, limiting the controller claim to this benchmark. Seed-clustered statistics, ablations, cross-task transfer, raw outputs, and manifests are packaged for audit. The results motivate explicit workflow-state evaluation while showing that apparently effective routing controls need their own generalization tests.

0.46

Sycophants in the Courtroom: Are LLMs Fragile to Juridical Authority and Evolving Legal Standards?

cs.CY cs.AIcs.CL ·2026-08-10 ·Lorenzo Molfetta, Alessio Cocchieri, Luca Ragazzi, Ilaria Bartolini, Marco Patella +1 more
top venuebenchmarkhighly cited similarity 0.66
Abstract · Please cite the definitive, peer-reviewed version of this article published in the Proceedings of the 64th Annual Meeting of the Association…

In medicine, claims remain valid when supported by empirical evidence grounded in stable biological reality. In law, by contrast, truth is contingent, defined by jurisdiction, temporal validity, and the hierarchy of authoritative sources. The recent success of large language models (LLMs) on medical licensing examinations has encouraged an expectation of comparable legal competence. This analogy, however, obscures a critical distinction between domains. Unlike in medicine, legal performance often depends less on inference than on determining when external authority is applicable, valid, and non-contradictory. We introduce a comparative diagnostic framework evaluating legal reasoning against medical baselines along four axes (knowledge recall, grounding, confidence, and robustness), uncovering a sharp domain asymmetry when applied to a new benchmark that encodes temporal validity and normative relationships. While medical LLMs reliably benefit from verified sources, legal LLMs struggle to assess when retrieved citations are useful or misleading, exhibiting overconfidence in perturbed contexts and sensitivity to superficial formatting cues. Increased model scale amplifies this tendency, revealing that stronger instruction following can coincide with weaker resistance to authoritative perturbations. These findings show that LLMs treat law as unstructured text rather than binding precedent, while revealing a tendency to over-trust authoritative but false information when external references conflict with a model's internal knowledge.

0.90

Right Answer, Wrong Reason: Accuracy, Consistency, and Consensus Are Misleading Indicators of LLM Faithfulness in Clinical Decision Support

cs.AI ·2026-09-26 ·Bharath Kumar Bolla, Chaitali Deb Purkayastha, Vishnu Surya Reddy Nandi
published similarity 0.66
Abstract · Accepted and received best paper award from ICETCI 2026 Conference, https://ietcint.com/

Clinical Large Language Models (LLMs) achieve strong medical-exam accuracy; however, a correct answer does not guarantee that the explanation names the concepts that actually drove the decision. We introduce three lightweight, directly interpretable metrics for this faithfulness gap: the Explanation Stability Index (ESI), which measures reasoning consistency across repeated queries; the Causal Faithfulness Score (CFS), which tests whether cited concepts drive predictions via concept ablation; and the Perturbation Stability Score (PSS), which measures robustness to semantic-preserving paraphrases. By evaluating six LLMs on 150 MedQA-USMLE questions (900 model-question observations), we found that only 23.3% of the cited clinical concepts were causally necessary. Correct answers had lower CFS than incorrect answers (0.212 vs. 0.398), answer consistency negatively predicted CFS (Spearman r = -0.466), and model pairs could agree on answers while sharing only 8.8% of cited reasoning concepts. These results show that accuracy, consistency, and consensus are incomplete safety signals for clinical decision-making support. The evidence is behavioral rather than mechanistic: concept ablation tests counterfactual sensitivity of outputs, not internal circuits.

0.28

Large language models exhibit unreliable updating of clinical judgment as patient evidence evolves

cs.AI cs.CL ·2026-10-02 ·Min Zeng, Rui Zhang
similarity 0.66
Abstract

Large language models (LLMs) are increasingly explored for clinical reasoning, but whether they appropriately revise judgments as patient evidence evolves remains unclear. We evaluated longitudinal belief updating using matched intensive-care trajectories from electronic health records. Across diverse LLMs, conditioning on a preceding judgment more often increased than reduced prediction error when estimates changed, replicated for a second endpoint. Controlled interventions revealed two failure modes. First, with preceding assessment fixed, models responded more strongly to worsening than matched improving respiratory evidence; this asymmetry persisted after headroom normalization at moderate and strong evidence levels. Second, with current evidence fixed, increasing prior risk from 10% to 90% shifted estimates by 26.2 percentage points, demonstrating causal influence of prior model beliefs. Prompting did not restore reliable updating. Evidence-Validated Longitudinal Update (EVLU) identified fewer, more reliable revisions, revealing a reliability-coverage trade-off. These findings establish longitudinal belief updating as a distinct dimension of LLM reliability.

0.44