CS Paper Radar

Electroencephalography Signal Analysis for Human Activities Classification: A Solution Based on Machine Learning and Motor Imagery

Tarciana C de Brito Guerra, Taline Nóbrega, Edgard Morya, Allan de M. Martins, Vicente A de Sousa

cs.NI ·submitted 2026-09-10 15:21 UTC · v1
publishedhighly cited

Abstract

Electroencephalography (EEG) is a fundamental tool for understanding the brain's electrical activity related to human motor activities. Brain-Computer Interface (BCI) uses such electrical activity to develop assistive technologies, especially those directed at people with physical disabilities. However, extracting signal features and patterns is still complex, sometimes delegated to machine learning (ML) algorithms. Therefore, this work aims to develop a ML based on the Random Forest algorithm to classify EEG signals from subjects performing real and imagery motor activities. The interpretation and correct classification of EEG signals allow the development of tools controlled by cognitive processes. We evaluated our ML Random Forest algorithm using a consumer and a research-grade EEG system. Random Forest efficiently distinguishes imagery and real activities and defines the related body part, even with consumer-grade EEG. However, interpersonal variability of the EEG signals negatively affects the classification process.

Journal ref
sensor 2023
DOI
10.3390/s23094277

Closest papers

Nearest neighbours by meaning across the whole index.

Decoding Imagined Speech: A Strictly Subject-Independent Approach Using EEG

cs.AI ·2026-09-24 ·Frederik Møllskov Trier, Xiaopeng Mao, Sadasivan Puthusserypady
similarity 0.66
Abstract

Imagined speech decoding from electroencephalography (EEG) has gained increasing attention as a potential communication pathway for individuals with severe motor impairments, yet reported performance often relies on evaluation protocols that do not clearly reflect cross-subject generalization. This study presents a transparent baseline investigation of a multi-class imagined speech EEG dataset under a strictly subject-independent evaluation framework. Two preprocessing and feature extraction pipelines were compared: a time-domain statistical feature approach and a frequency-domain spectral bandpower approach, evaluated using subject-wise cross-validation and trial-level majority voting with a random forest classifier. The spectral pipeline achieved a significantly higher mean trial-wise accuracy than the statistical pipeline (49.03 $\pm$ 4.18% vs. 37.97 $\pm$ 3.79%) for coarse-level classification across subjects. Forward feature selection further indicated that a limited subset of frequency bands captured most of the discriminative information. Overall, this work provides a strong basis for future brain-computer interface studies targeting improved cross-subject generalization in EEG-based imagined speech decoding.

0.23

Personalized Scorer Modeling: A Learning-Based Framework for Deriving Robust Sleep Stage Labels from Multiple Experts

cs.LG cs.AI ·2026-08-12 ·Seyyed Ali Hoseini, Javad Baseri, Hamid Saadatfar, Edris Hoseini Gol, AmirHossein Eshghi
similarity 0.61
Abstract

Sleep stage classification is important for the diagnosis and management of sleep disorders, yet most automatic staging studies evaluate models against a single reference hypnogram despite known inter-scorer variability. This study investigates whether multi-scored datasets can be used to construct more reliable reference labels from the collective behavior of multiple experts. We use the publicly available DOD-H and DOD-O datasets. EEG (C3-M2) and chin EMG signals were segmented into 30-s epochs, and 30 features were extracted from each modality, yielding 60 features for EEG+EMG. We propose a learning-based hypnogram (LBH) that models the stage-specific behavior of each scorer using confusion matrices derived from machine-learning models. After column normalization, these matrices estimate the probability of each true sleep stage given each scorer's label; probabilities are aggregated across scorers to assign the final label for each epoch. LBH was evaluated with random forest, support vector machine, and multilayer perceptron classifiers under EEG-only and EEG+EMG settings, and compared with the dataset hypnogram (DH) and best-scorer hypnogram (BSH). LBH consistently improved overall performance. The best results were obtained with random forest and EEG+EMG, reaching 86.07% accuracy, 85.46% precision, and 85.29% F1-score on DOD-H, and 86.04% accuracy, 85.21% precision, and 84.70% F1-score on DOD-O. These findings suggest that personalized scorer modeling can improve reference hypnogram construction without discarding information from individual experts.

0.04

Leveraging a Foundation Model for the EEG-Based Diagnosis of Alzheimer's Disease

cs.LG q-bio.NC ·2026-08-27 ·Maggie Lin, Chung-Lin Hou, Tzyy-Ping Jung
published similarity 0.59
Abstract · 7 pages, 9 figures, 1 table. Accepted and presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biol…

Biological heterogeneity in Alzheimer's Disease (AD) poses a critical diagnostic challenge, particularly for traditional linear methods that fail to capture non-linear neural dynamics. To address this, we propose a diagnostic framework utilizing the Large Brain Model (LaBraM), pretrained on over 2,500 hours of EEG data. By integrating these high-dimensional latent embeddings with a non-linear Random Forest classifier, our approach effectively isolates robust disease markers. Under a rigorous subject-independent 5-fold cross-validation protocol, the method achieves an ROC-AUC of 89.36% +/- 3.49%, PR AUC of 81.45% +/- 4.43%, and Balanced Accuracy of 82.44% +/- 4.34% in distinguishing dementia patients from healthy controls. Notably, this performance uses only 8-second EEG segments, surpassing traditional spectral baselines, including band-power and parameterized oscillatory features (FOOOF). Post-hoc occlusion analysis confirms the model captures clinically validated biomarkers, specifically occipital-frontal Alpha and Theta rhythm degradation. Additional neurophysiological alignment analysis demonstrated that higher LaBraM-predicted dementia probability significantly correlated with worse cognitive performance, greater clinical severity, increased theta and alpha relative power, and higher aperiodic exponent. These findings demonstrate that deep latent representations extract clinically relevant signatures from noisy signals, enabling precise, rapid, and data-efficient diagnosis.

0.30

Emotion Recognition from Physiological Signals Using Machine Learning Algorithms Under Controlled Emotional Stimuli

eess.SP ·2026-09-04 ·Aditi Site, Annariina Lohiranta, Tarmo Lipping
similarity 0.58
Abstract

Emotion recognition using physiological signals plays a crucial role in well-being analysis, affective computing and human-computer interaction. This study investigates the performance of multiple machine learning models in classifying targets such as discrete emotions with varying granularity, valence and arousal using physiological signals such as Electrocardiogram (ECG) and Galvanic Skin Response (GSR). In here, we extracted various time- and frequency-domain features from the ECG and GSR data to train machine learning models. The results indicate that categorizing discrete emotions with fewer emotions and categorizing arousal achieves good classification accuracy with tree-based models. XGBoost achieved accuracy of 52.8 % for classifying discrete emotions and Random Forest achieved accuracy of 53.6% for classifying arousal. In both the cases, the combination of ECG+GSR feature sets achieved best performance. These findings highlight the effectiveness of physiological signals in capturing emotional states and support their use for emotion recognition systems.

0.26

Best Practices in EEG Analysis: Preprocessing, Modeling, and Machine Learning

eess.SP cs.LG ·2026-09-29 ·Parsa Razmara, Woojae Jeong, Aditya Kommineni, Raymundo Cassani, Richard Leahy +1 more
published similarity 0.57
Abstract · 38 pages, 5 figures. Chapter 16 of the 2026 monograph "Electroencephalogram Signals and Cognition," edited by Hema A. Murthy, Shrikanth Nara…

Electroencephalography (EEG) analysis requires careful choices in preprocessing, statistical modeling, and machine learning because EEG signals are highly susceptible to artifacts, volume conduction, low signal-to-noise ratio, and substantial inter-subject variability. This chapter provides a practical and methodological guide to modern EEG analysis, spanning EEG preprocessing, artifact removal, filtering, bad-channel detection and interpolation, re-referencing, independent component analysis (ICA), and preprocessing of simultaneous EEG-fMRI recordings. We review major approaches for computational EEG analysis, including event-related potentials (ERPs), time-frequency analysis, functional and effective connectivity, source localization, multivariate decoding, permutation testing, and multiple-comparison correction. We then examine machine-learning methods for EEG, from feature-based classifiers to deep learning and emerging EEG foundation models, with emphasis on cross-subject generalization, limited-data regimes, data leakage, evaluation metrics, and fair benchmarking. Reproducibility is treated as a core requirement throughout, including transparent preprocessing, BIDS-EEG data organization, standardized derivatives, preservation of raw data, and FAIR data practices. The chapter is intended as a practical reference for researchers developing reliable, interpretable, and reproducible EEG analysis and machine-learning pipelines.

0.47

Motor Imagery Classification Using Hybrid Cross-Subject Class Mixup and Selective Attention

cs.LG ·2026-11-16 ·Jiwon Kim, Chae-Won Lee, Jong-Seok Lee
similarity 0.56
Abstract

Motor imagery (MI) enables a brain-computer interface (BCI) to decode movement intentions without overt movement. Hybrid electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) classification combines complementary signals, but inter-subject variability and the design of information exchange between modalities affect generalization to new subjects. We propose a framework that combines Cross-Subject Class Mixup (CSCM) with Selective Attention. CSCM aims to construct new training data to make the model robust against inter-subject variability. It independently selects EEG and fNIRS donor trials from other training subjects within the anchor class and mixes each modality while preserving the original label. Selective Attention provides an effective way to simultaneously model the temporal signal characteristics and fuse the two modalities. It retains causal temporal self-attention for EEG and uses a classification token (CLS) to integrate both modalities, without fNIRS attention updates or direct cross-modal temporal-token attention. Leave-one-subject-out (LOSO) evaluation across 28 subjects on a public EEG-fNIRS dataset yields a mean balanced accuracy (BA) of 76.85% and a macro-averaged F1 score (Macro-F1) of 76.58%. The proposed model achieves the highest mean performance among five reimplemented baselines. We also examine the contributions of CSCM and Selective Attention through modality-specific mixing and donor-policy comparisons, temporal-policy comparisons, interventions on direct cross-modal paths, and component ablations.

0.11

EEG-AS: Instance-Level Foundation Model Selection for EEG Foundation Models via Behavior Reconstruction

cs.LG cs.AI ·2026-09-01 ·Yunzhen Zhang, Ruoxi Piao, Muhammad Ibrahim Ali Shah, Hasan Onur Keles, Mustafa Misir
theory similarity 0.56
Abstract

Electroencephalography (EEG) is a non-invasive technique for measuring neural activity and has been widely used in neuroscience applications. Recent advances in EEG foundation models have enabled strong performance across diverse neural decoding tasks. However, no single foundation model consistently performs best across datasets or individual EEG instances, while instance-level model selection remains largely unexplored. To address this limitation, we formulate EEG foundation model selection as an instance-level Algorithm Selection (AS) problem. We propose \textbf{EEG-AS}, an instance-level algorithm selection framework that characterizes each EEG instance using inference-available latent EEG embeddings, handcrafted neurophysiological features, and an anchor foundation model. During training, EEG-AS learns to reconstruct unavailable foundation-model behaviors from privileged prediction tokens conditioned on an anchor foundation model, while during inference it estimates these behaviors without executing the entire model portfolio, enabling efficient selection from seven EEG foundation models. Experiments on seven public EEG benchmarks demonstrate that EEG-AS substantially narrows the gap between the Single Best Solver (SBS) and the oracle upper bound for each instance. These results highlight the effectiveness of instance-level AS for adaptive deployment of EEG foundation models.

0.30

OOD Detection for EEG-based Machine Learning in High-Risk Environments

cs.LG ·2026-08-18 ·Philipp Bomatter, Henry Gouk
benchmark similarity 0.55
Abstract

Machine learning models for electroencephalography (EEG) analysis show great promise across a wide range of applications, but their deployment in high-risk domains is hindered by their vulnerability to distribution shifts. Encountering out-of-distribution (OOD) data can lead to catastrophic, overconfident predictive failures. While OOD detection methods can mitigate these risks, they remain heavily under-explored for EEG. Moreover, evaluations in the broader literature typically evaluate OOD detection performance in isolation, ignoring their practical impact on downstream applications. To bridge this gap, we introduce a benchmark for EEG OOD detection, evaluate a broad range of methods, and furthermore evaluate their value in two clinical downstream prediction task. Our results disentangle OOD detection and model uncertainty estimation capabilities, which are frequently conflated in the literature, provide actionable insights about the current state of the art for EEG OOD detection and model uncertainty estimation, and demonstrate how complementary methods for both aspects can be combined to form a robust safety net for the deployment of EEG-based machine learning models in real-world applications.

0.31