CS Paper Radar

Occlusal Geometry in Closed Form for Orthodontic Report Generation

Ajo Babu George, Govind Arun, Sidharth N Krishna, Uma Ranjan

cs.CV cs.CL ·submitted 2026-09-02 14:58 UTC · v1
code/dataunusual

Abstract

Orthodontic report generation from intraoral data is normally cast as multimodal captioning, yet the released Bite2Text scan pairs are supplied already registered in occlusion, which makes several core occlusal quantities directly measurable rather than inferable. The system reported here exploits that property: an anatomical frame is recovered per case from arch taper and arch closure instead of the stated RAS convention, which does not hold across the release, and each arch is reduced to an occlusal ridge profile in arch-angle coordinates yielding overbite, overjet, midline deviation, transverse overlap, crossbite extent, cusp interdigitation lag, and the occlusal curves in closed form. Gradient boosting maps 31 such measurements onto 13 template fields, a field being predicted only where patient-level cross-validation beats its own majority baseline, and a deterministic renderer emits the corpus six-part narrative; a ConvNeXt-Tiny classifier over the five standardised photographic views is fused per field, raising mean field accuracy from 0.601 to 0.683. Reimplementation of the challenge evaluator shows that its BLEU-4 and METEOR are local variants whose F-mean weights recall nine to one, that two clinicians agree on 47 percent of findings for the same patient, and that a constant report consequently outscores a genuine second clinician report by 0.165 captioning. Held-out scores reach BLEU-4 0.458 and METEOR 0.677 against intraoral scan references and 0.278 and 0.507 against photograph references, and the submitted system placed third in the ODIN 2026 Bite2Text test phase at 0.2680 and 0.4629, within 0.022 BLEU-4 of first, running on CPU in under ten seconds per case. The dataset and code are available at https://github.com/GIND123/ODIN_toothfairy4

Comment
10 pages, 4 figures. Third-place system in the ODIN 2026 Bite2Text test phase. Code and data processing resources: https://github.com/GIND123/ODIN_toothfairy4

Closest papers

Nearest neighbours by meaning across the whole index.

PeriaTrace: Tooth-Level Grounding Diagnosis and Patient-Facing Explanations from Periapical Radiographs

cs.AI ·2026-11-17 ·Zhenhuan Zhou, Yuchen Zhang, Jingbo Zhu, Shiqing Ma, Yanlin Wu +1 more
similarity 0.61
Abstract · 20 pages, 5 figures, Under Review

Periapical radiographs (PRs) are central to endodontic diagnosis, but interpreting them and preparing reports are time-consuming. Technical language can limit patients' understanding, while existing automated methods often lack tooth-level links between findings and image evidence. We present PeriaTrace, a three-stage framework integrating tooth-level diagnosis, visually grounded report generation, and patient-friendly explanations and care recommendations. PeriaTrace was developed and evaluated using 12,877 PRs from an internal dataset and two external clinical cohorts. In internal evaluation, it achieved a macro Dice coefficient of 85.35%, BLEU-4 of 0.6504, an F1 score of 94.37% for joint tooth localization and Fédération Dentaire Internationale (FDI) identification, and a grounding-tag F1 score of 77.93%. In the two external cohorts, senior endodontists considered 91.16% and 84.52% of reports suitable for retention or revision without complete rewriting. Generation averaged 4.41 seconds per PR, several tens of times faster than manual drafting. Among 196 survey participants without medical backgrounds, 96.4% preferred reports with plain-language explanations and care recommendations, and 84.7% found visual localization cues helpful. PeriaTrace may enable faster, evidence-traceable reporting while supporting clinical review and patient communication. (Abridged version)

0.26

Detection is solved, delineation is not: what governs tooth segmentation on panoramic radiographs

cs.CV cs.LG ·2026-09-18 ·Muhammad Rehan, Moaz Amjad, Syed Danial Ahmed, Mariam Adnan, Haider Ali
code/data similarity 0.58
Abstract · 15 pages, 6 figures, 5 tables. Code: https://github.com/Rehan000/opg-tooth-segmentation

Automatic tooth segmentation and FDI numbering on panoramic radiographs underpins computer-assisted dental diagnosis, yet which factors govern performance remains unclear. We assemble a corpus of 1,422 panoramic radiographs containing 42,142 expert-delineated tooth polygons across the 32-class FDI taxonomy, annotated by 30 dental practitioners and independently reviewed by two others, and use it to isolate input resolution, architecture and anatomical priors under a single evaluation protocol. First, resolution dominates: across a controlled 640/1024/1280 ablation, mask mAP50-95 rises 0.656 -> 0.710 -> 0.717 while mAP50 stays flat at ~0.982. Both gains are significant under a paired bootstrap over images (p < 0.001, p = 0.024); neither mAP50 change is distinguishable from zero. Added resolution buys boundary precision, not detection. Second, architecture is nearly irrelevant in-domain: a query-based transformer with 2.1x the parameters is statistically equivalent to a one-stage detector (95% CI [-0.0064, +0.0064]), only marginally better under domain shift, 5.5x slower on CPU and not executable under standard ONNX runtimes. Third, three targeted interventions fail: a LoRA-adapted self-supervised encoder underperforms, a promptable foundation segmenter degrades masks by 39%, and globally optimal anatomical label assignment yields +0.0007 despite correcting a constraint violated in 40% of out-of-domain predictions. Zero-shot transfer to an independent multi-centre cohort, verified overlap-free, costs 62% of mask mAP50-95 but only 18% of mAP50, reproducing the dissociation. Decomposing masks along the tooth axis localises the residual error to the apical third. Boundary precision is therefore the binding constraint, and effort is better directed at resolution and acquisition diversity than at architectural novelty.

0.36

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

eess.IV cs.CV ·2026-09-09 ·Zhichun Jin, Zhicheng He, Hao Xu, Dongyang Li, Lin Wang +2 more
published similarity 0.58
Abstract · Accepted by Biocybernetics and Biomedical Engineering

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

0.36

EviDent-CBCT: Evidence-Bottlenecked Report Generation from Dental CBCT under Non-Exhaustive Report Supervision

cs.CV cs.AI ·2026-10-01 ·Ruiyang Hao, Zhi Qin Tan, Yulan He, Owen Addison, Yunpeng Li
similarity 0.58
Abstract

Dento-maxillofacial cone-beam CT (CBCT) reports may contain dozens of tooth-specific, anatomical, and spatial findings from a single 3D scan. Learning to generate such reports from limited clinical data is challenging because routine reports may not exhaustively document image findings, and a non-mention may reflect either absence or non-reporting. We present EviDent-CBCT, an evidence-bottlenecked framework designed for this incomplete supervision. An anatomy-aware network maps each CBCT scan to a discrete record of tooth-level, global, and tooth-IAC evidence. A dental-logic consistency projection reconciles incompatible evidence before a deterministic renderer and an image-blind local language model generate the report using only this record. For tooth-level evidence, reliability-aware training uses eligible non-mentions as reduced-weight negatives, while unreported global and tooth-IAC labels remain unknown. A metal-sensitive input channel preserves intensity cues from dental materials. Across three validation runs, EviDent-CBCT achieves $0.666\pm0.006$ merged evidence set-F1 and $0.402\pm0.003$ RadFact-Lite-Dental logical-F1, versus $0.371\pm0.018$ for the strongest controlled direct baseline. In the ODIN 2026 challenge, it ranked second in automated evaluation and third in blinded clinical Arena comparison on the hidden test set. These results support the discrete evidence record as an effective and auditable interface for CBCT report generation.

0.07

REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models

cs.CV ·2026-11-06 ·Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi
top venue similarity 0.56
Abstract · 32 pages, 6 figures, Accepted to NeurIPS 2026 ED Track

Evaluation of 3D medical foundation models is typically dominated by downstream task scores, which entangle representation quality with adaptation choices. This is especially critical in volumetric imaging, where spacing and anisotropy can substantially alter image statistics while the anatomy itself remains unchanged. We therefore introduce \textbf{REFORM-3D}, a \textbf{R}epresentation-centric \textbf{E}valuation \textbf{F}ramew\textbf{OR}k for benchmarking frozen 3D medical vision foundation \textbf{M}odels across three questions: Acquisition Robustness, asking whether features remain stable when spacing varies while anatomy is fixed; Cross-Modal Anatomical Alignment, asking whether labeled anatomical structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, asking whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. These are also pretraining questions, because what a 3D encoder learns depends on how volumes are geometrically presented during self-supervised pretraining. We further introduce Med3DINO encoder family, pretrained on $62.6$K unlabeled MR, CT, PET, CTA, and CBCT volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling. Across Med3DINO and heterogeneous external encoders, REFORM-3D reveals module-specific strengths rather than a single model ordering. Within the controlled Med3DINO comparison, voxel-relative sampling yields lower embedding drift, whereas spacing-aware resampling favors anatomical transfer; semantic-transfer advantages depend on the dataset and feature type. Project link: \href{https://endarzboy.github.io/reform3d-website/}{\highlightLR{REFORM-3D}}.

0.50

Entity-Constrained CBCT Retrieval for Low-Resource Dental Record Completion

cs.CV ·2026-08-22 ·Nhi Ngoc-Yen Nguyen, Thai Nguyen, Kiet Huynh Cao Tuan, Huy-Hieu Pham
published similarity 0.55
Abstract · Accepted at the ODIN 2026 Workshop, MICCAI 2026

Completing dental records from cone-beam computed tomography (CBCT) is difficult when annotation is scarce and individual clinical fields are supported by different types of evidence. MMDental Task 3 requires seven-field record completion from only 50 labeled CBCT cases and scores the correctness of structured FDI positions and ICD codes; consequently, a visually plausible retrieved record can still be harmful when it introduces an unsupported entity. We propose Entity-Constrained CBCT-Guided Retrieval (ECCR), a parameter-free framework that separates evidence availability from evidence authority. A corpus-derived prior first supplies the complete record. A frozen 3D encoder retrieves image-conditioned Diagnosis evidence, which is appended only if it does not expand the prior FDI or ICD entity set, so the asserted entity set is invariant by construction. On public validation, ECCR reaches a weighted score of 0.3134, improving on both full-record multimodal retrieval (0.2237) and a static text-only prior (0.2915); the guard blocks 63.3% of retrieved candidates, each of which would otherwise have injected an FDI position or ICD code absent from the prior. On the final test evaluation, ECCR obtains 11.37 of a 97.4-point attainable maximum, securing second place overall. The result indicates that, in an extreme low-resource setting, controlling what multimodal evidence is allowed to modify can be more reliable than transferring an entire retrieved record.

0.43

AgenTeeth: A Model-Agnostic Framework for Suppressing Hallucination in Frozen Vision-Language Models on Dental X-Rays via Tool Evidence Injection

cs.CV ·2026-09-15 ·Ahmed Rafid, Fariya Ahmed, Rumman Adib, Mehedi Ahamed, Ajwad Abrar +1 more
similarity 0.55
Abstract · 10 pages, 2 figures, 5 tables

Vision-language models (VLMs) remain largely unreliable on panoramic dental radiographs and can rely on learned anatomical priors rather than evidence in the image. This is particularly problematic for tooth localization and spatial reasoning, and fine-tuned dental VLMs can retain the same spatial biases. We present AgenTeeth, a model-agnostic, tool-augmented framework that grounds frozen VLMs using seven specialized dental vision experts. A question-aware orchestrator selects the relevant tools, whose detections are mapped to FDI tooth numbers or anatomical regions and returned as structured findings together with annotated image overlays. A fresh synthesis call then answers the question using this evidence, without fine-tuning the underlying VLM. On MMOral-OPG-Bench, AgenTeeth improves four backbone VLMs by 12.9-23.0 percentage points over their baselines. Our strongest configuration reaches 65.66% on open-ended VQA, compared with 45.35% for OralGPT-Plus. The advantage also holds at matched scale: a frozen Qwen2.5-VL-7B-Instruct with AgenTeeth reaches 48.11%, exceeding OralGPT-Plus built on the same backbone after supervised fine-tuning and reinforcement learning for tool use. We release the framework, all seven expert models, and a dentist-annotated dataset for alveolar bone-loss detection in panoramic radiographs.

0.13

Automated Perceptually-Motivated Assessment of Photographic Consistency in Paired Clinical Photographs: Pipeline Development and Internal Evaluation

cs.CV ·2026-09-14 ·Derrick Lin, Samantha Rabinovich, Joclin Rabinovich, Kassra Garoosi, Sumun Khetpal +3 more
similarity 0.55
Abstract · 26 pages, 7 figures, 12 tables. Submitted to SPIE Journal of Medical Imaging

Purpose: Paired pre- and post-operative photographs are the standard unit of evidence for plastic surgical outcomes, yet no objective metric verifies whether two images of the same patient were captured under conditions consistent for comparison. Approach: We developed a perceptually motivated pipeline that analyzes pre/post pairs across thirteen calibrated sub-metrics, partitioned by unsupervised correlation-structure analysis into five data-driven clusters (photometric, texture / sharpness, pose, illumination direction, and pitch), averaged within each cluster and combined across clusters by a weighted sum into a single consistency score. Each sub-metric is calibrated so that its median difference across published within-patient pairs scores 0.5, which is a reference point and carries no pass/fail meaning. The pipeline was calibrated on 134 matched within-patient published pre/post pairs and evaluated against identical-image pairs, synthetic-perturbation pairs, and 134 mismatched cross-publication pairs. Results: The master consistency score S separated matched from mismatched pairs (sensitivity index d' = 2.15, 95% confidence interval (CI) [1.83, 2.55]; area under the receiver operating characteristic curve AUC = 0.928, 95% CI [0.896, 0.959]), closely matching Gaussian-equal-variance predictions. The three head-pose angles did not fall in one cluster: yaw and roll grouped together while pitch separated. Identical pairs scored at ceiling (S = 0.99) and the master score fell monotonically with perturbation magnitude on all five perturbation axes. Conclusions: The score quantifies photographic comparability, not aesthetic or surgical quality, and provides a freely available web tool for auditing the photographic comparability of pre/post pairs, pending validation against expert judgment.

0.40