CS Paper Radar

DTI-Guided Volumetric Spherical Harmonics Regression for Single-to-Multi-Shell dMRI Synthesis

Binghua Li, Christina Andica, Tong Liang, Ziqing Chang, Chao Li, Wataru Uchida, Kaito Takabayashi, Qibin Zhao, Toshihisa Tanaka, Zhe Sun, Shigeki Aoki

cs.CV ·submitted 2026-09-13 06:15 UTC · v1
top venuecode/data

Abstract

Multi-shell diffusion MRI (dMRI) unlocks more expressive microstructural modeling than single-shell scans, yet its longer acquisition time hinders deployment in large-scale cohorts and time-constrained clinical settings. Synthesizing an unobserved shell from a single-shell input is fundamentally ill-posed and further complicated by protocol mismatch, where source and target gradient direction sets may not align. We propose DTI-SHNet, a single-to-multi-shell synthesis framework that operates in the real symmetric spherical harmonics (SH) coefficient domain and performs spatially aware volumetric regression. Given a source shell, we estimate diffusion tensor imaging (DTI) and use direction-agnostic parametric maps along with a brain mask as conditioning priors to guide a 3D U-Net regressor from source-shell to target-shell SH coefficients. To couple coefficient accuracy with signal fidelity, we introduce a signal consistency regularization that reconstructs signals on randomly sampled canonical directions from predicted coefficients and enforces agreement in the signal domain. Experiments on UK Biobank and Cam-CAN data for b=1000 to b=2000 dMRI synthesis show that DTI-SHNet achieves competitive visual quality compared to advanced methods, while better preserving downstream diffusion measures. Our code is available at https://github.com/xiaovhua/dti-shnet.

Comment
10 pages, 4 figures. Accepted at MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Unified Multi-plane Autoregressive Diffusion for 3D Multi-contrast MRI Synthesis

cs.CV ·2026-10-07 ·Yejee Shin, Geonhui Son, Jinglu Wang, Minwoo Jung, Yan Lu +1 more
top venue similarity 0.66
Abstract · Accepted to ECCV 2026

Acquiring a complete set of magnetic resonance imaging (MRI) contrasts is time-intensive and uncomfortable for patients, despite the diagnostic value of multi-contrast imaging. This motivates synthesizing missing contrasts from those already acquired, which is an inherently 3D problem requiring anatomical coherence across axial, sagittal, and coronal planes. However, fully 3D generative models are often impracti- cal under computational resources that scale cubically with volume size. We propose a unified Multi-Plane Autoregressive Diffusion (MPAD), a latent diffusion framework that achieves full-volume 3D synthesis using efficient plane-wise 2D operations while preserving volumetric coherence. A 3D autoencoder first compresses MRI scans into an isotropic 3D la- tent representation. A 2D diffusion model is then trained to reconstruct masked latent slices of the target contrast, conditioned on both source- contrast slices and unmasked target-contrast slices. During inference, we introduce plane-wise autoregressive synthesis with inter-plane priors. Slices are generated autoregressively in random order within one plane orientation to maintain intra-plane continuity, then propagated as con- ditioning priors to orthogonal plane orientations to enforce inter-plane consistency. Compared to 3D latent diffusion baselines, MPAD reduces training and inference FLOPs by 7x and 3x, respectively, while also lowering inference time and peak memory consumption. Experiments on multiple datasets demonstrate that MPAD achieves superior perfor- mance, generating high-fidelity 3D volumes and supporting one-to-many translation within a single unified model.

0.33

Implicit Neural Models for Direct Multi-Shell Diffusion MRI Signal Estimation

eess.IV cs.CV ·2026-10-16 ·Sanna Persson, Fabian Leander Sinzinger, Christoffer Olsson, Rodrigo Moreno
similarity 0.66
Abstract · 23 pages (9 pages main text + supplementary material), 9 figures, 18 tables

Diffusion magnetic resonance imaging is a noninvasive technique that is sensitive to the motion of water molecules in human tissue. The image signal is commonly described in q-space; however, a complete coverage of this space is often infeasible due to hardware and acquisition time limitations. In this work, we propose to represent the entire diffusion signal using an implicit neural representation network with wavelet activation functions. The signal space is encoded using Fourier features and spherical harmonics basis functions for a continuous output distribution of the raw diffusion data, enabling both super-resolution and q-space interpolation. Additionally, we introduce a pretraining strategy using a group template, enabling faster per-subject optimisation when combined with nonlinear registrations of subjects into template space. We tested the method with 10 subjects from the Human Connectome Project and 26 subjects from in-house data (multidimensional diffusion MRI from a Parkinson's disease cohort). The results show that the proposed method yields high-fidelity reconstructions with significantly reduced memory requirements compared to raw diffusion-weighted images. The pretraining scheme showed good generalisability properties on data acquired with very different protocols. We further assess the method on downstream metrics relevant to diffusion MRI data from the learned representations.

0.31

Bridging Modalities on the Cortex: Surface-based MRI to PET Translation with a Diffusion Bridge

cs.CV cs.AI ·2026-09-17 ·Yitong Li, Alexandra Samoylova, Fabian Bongratz, Timo Grimmer, Dennis M. Hedderich +2 more
code/data similarity 0.65
Abstract

Cortical hypometabolism measured by Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is a highly sensitive biomarker for dementia diagnosis. However, high costs, radiation exposure, and limited accessibility constrain its clinical utility. While cross-modal synthesis from Magnetic Resonance Imaging (MRI) offers a promising alternative, existing volumetric generation methods do not explicitly account for the highly folded cortical geometry, where disease-related patterns predominantly reside. To address this, we introduce a novel surface-based diffusion bridge framework DB-SUiT for MRI-to-PET translation that operates natively on the cortical manifold. A conditional Spherical U-shaped vision Transformer (SUiT) is specifically designed to model the intricate cross-modal relationships while preserving surface topology. It combines spherical convolutional encoders for multi-scale surface feature extraction with bottleneck Transformers to capture long-range spatial dependencies, while incorporating demographic and subcortical conditions to refine the synthesis. Evaluated on two datasets, including subjects with different dementia types, DB-SUiT demonstrates high-fidelity synthesis that substantially outperforms other baselines. In automated dementia classification, synthesized PET surfaces improve performance over MRI by 14.2% and PET volumes by 11.3%, approaching the performance of real PET surfaces. In a blinded reader study, synthetic PET achieved 85.5% diagnostic accuracy, compared with 75.8% for MRI and 95.2% for real PET. This further demonstrates cross-cohort and cross-pathology generalization, as the model was evaluated without retraining on an external cohort that included a dementia subtype not represented during training. Our code is available at https://github.com/ai-med/DB-SUiT.

0.32

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.64
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Advanced Brain Tissue Imaging with Data-Consistent Diffusion Priors in Laminographic X-Ray Nanoimaging

cs.CV ·2026-09-09 ·Wenxuan Fang, Abraham L. Levitan, Ana Diaz, Carles Bosch, Adrian Wanner +8 more
similarity 0.63
Abstract

Nanoscale imaging of mammalian brains is critical for connectomics. X-ray laminography enables high-throughput imaging of extended, plate-like biological specimens. However, the tilted acquisition geometry leads to incomplete Fourier-space coverage, giving rise to a missing-cone of information. Conventional reconstruction methods cannot recover unmeasured information within the cone, resulting in artifacts that distort fine brain structures. While resolving these requires modeling 3D structure, direct 3D deep learning approaches are limited by data scarcity and computational cost. Here we introduce LUCID (Laminography with Unified Consistent Diffusion), a framework that combines multi-view diffusion priors with projection-domain data consistency. LUCID integrates complementary 3D structural information while enforcing strict alignment with the laminography forward model. On simulated datasets, LUCID substantially improves spatial fidelity and restores missing Fourier components, outperforming baseline methods. Applied to experimental laminography data, LUCID generalizes robustly despite being trained exclusively on fully sampled tomographic volumes, and effectively recovers unmeasured Fourier information.

0.20

Reduce, Then Encode: Multiscale Volumetric Reduction for 2D Foundation Models in Brain MRI

cs.CV ·2026-09-28 ·Dexuan Ding, Yuankai Qi, Bogong Wang, Luping Zhou, Amin Beheshti
similarity 0.62
Abstract

Pretrained 2D foundation models offer a practical alternative to dedicated 3D pretraining for brain structural magnetic resonance imaging (sMRI), but their use on volumetric data requires bridging the mismatch between a 2D encoder and a 3D volume input. Existing methods typically encode slices independently and integrate their features afterwards. We introduce Multiscale Volumetric Reduction (MVR), a reduce-then-encode approach that compresses each anatomical view from (D) slices into (M << D) complementary 2D components before foundation-model encoding. MVR combines an uncentered-PCA base component derived from the original through-plane intensities with residual detail components constructed from multiscale spatial descriptors. The reduction is estimated from the training volumes without diagnostic labels or gradient-based optimization and remains fixed thereafter. The resulting components are independently processed by a shared frozen 2D foundation model and concatenated for linear probing. Under this frozen-encoder setting, MVR achieves strong overall performance across ADNI, OASIS, and ABIDE relative to the evaluated 2D-to-3D adaptation methods and simple input-reduction baselines, while also generalizing strongly from ADNI to AIBL.

0.13

STAIRS: Staging the Inverse Problem via Admissible-Support Scheduling for Unrolled MRI Reconstruction

cs.CV ·2026-11-06 ·Xiangjian Hou, Chang Ni, Chao Qin, Zhiwei Tan, Xin Wang +4 more
similarity 0.62
Abstract

Accelerated magnetic resonance imaging (MRI) forms images from incomplete Fourier measurements, shifting acquisition burden to computational reconstruction. Deep unrolled networks interleave learned regularization and data consistency, yet typically estimate the full unmeasured spectrum at every cascade. We propose STAIRS (Staging the Inverse Problem via Admissible-Support Scheduling), which projects intermediate reconstructions onto nested Fourier supports that expand to the full spectrum and conditions each update on its support transition. Conditional increments of a regularized log-determinant score of training covariance define a normalized spectral coordinate, accounting for dependencies between newly and previously admitted frequencies. Dyadic targets allocate larger coordinate increments to earlier cascades and are mapped to fixed supports before training, enabling coarse-to-fine reconstruction with unchanged sampling masks and data consistency. On fastMRI and Stanford2D, STAIRS improves matched Transformer (HUMUSNet) and convolutional (NAFNet) backbones in single- and multi-coil reconstruction, including radiologist-annotated pathology regions. It also outperforms predictor-based progression with lower parameter overhead and inference latency. Stage-wise analysis shows repeated error correction by projection and lower intermediate reconstruction errors than the backbones alone throughout support expansion. Ablations favor dyadic allocation over uniform expansion for square and line-band supports and over manual front-loading for square windows. Support projection alone improves reconstruction, and transition conditioning strengthens the gain. Cross-dataset evaluation shows improvements for both backbones in both directions. Support allocation thus complements regularizer design in unrolled MRI reconstruction.

0.22

Multimodal-Conditioned Latent Diffusion Models for Spatiotemporal Brain MRI Forecasting

cs.CV cs.AI ·2026-10-18 ·Antonio Scardace, Silvia Ingala, Sebastiano Battiato, Daniele Ravì
publishedcode/data similarity 0.62
Abstract · Accepted to WACV 2027

Spatiotemporal forecasting of 3D anatomical changes is a critical generative vision challenge for modeling Alzheimer's Disease (AD) progression. While brain MRI forecasting from single-modality data has advanced, other key complementary multimodal biomarkers remain underutilized. In this work, we propose the Multimodal-Conditioned Latent Diffusion Model (MC-LDM), a novel framework for patient-specific brain MRI synthesis. MC-LDM leverages multimodal biomarkers---MRI, tau-PET, Clinical Dementia Rating (CDR), and APOE4---during training, but relies only on baseline MRI, APOE4, and patient metadata at inference, reflecting realistic clinical availability. Our contributions are threefold: (1) a Latent Diffusion Model (LDM) fine-tuned via Low-Rank Adaptation (LoRA) for data-efficient learning; (2) a multimodal conditioning that integrates molecular and clinical signals to model heterogeneous disease trajectories; and (3) auxiliary predictors estimating unobserved multimodal biomarkers from MRI features and patient covariates to condition the diffusion model, removing the need for these assessments at inference. Trained on 1,355 visits from 852 subjects in the Alzheimer's Disease Neuroimaging Initiative (ADNI), MC-LDM reduces average regional volumetric MAE by 18% over the second-best baseline on an independent test set of 664 visits. To our knowledge, MC-LDM represents the first diffusion-based framework to leverage multimodal priors for MRI forecasting. This conceptual advancement enables patient-specific trajectory generation that captures aspects of AD heterogeneity not observable from structural anatomy alone, bridging the gap between rich multimodal supervision and the strict constraints of routine clinical deployment. Code is available at: https://github.com/antonioscardace/MC-LDM.

0.43