CS Paper Radar

Rethinking Correctness for Uncertainty Estimation in Clinical Prediction with Vision-Language Models

Mingcheng Zhu, Jinning Liang, Tingting Zhu

cs.LG ·submitted 2026-09-14 08:03 UTC · v1

Abstract

Vision-language models are increasingly explored for clinical prediction from electronic health records and medical images, where identifying unreliable predictions is important for safe deployment. Uncertainty estimation (UE) enables detecting such predictions, but its evaluation depends on a correctness criterion that determines whether each model output is correct. If this criterion disagrees with human judgement or distorts downstream UE performance, conclusions about model reliability can be misleading. We introduce a two-axis framework that evaluates correctness criteria by their agreement with human judgements and fidelity to human-referenced UE performance. We assess eight criteria across three clinical prediction tasks and three models using 450 predictions annotated by two reviewers. Across the audited tasks, canonical exact matching (EM) achieved the highest observed human agreement and lowest UE distortion, while the BERT-based matching (BEM) and LLM-judge also showed strong human agreement. Across four UE methods and 23,254 clinical predictions, criterion choice changed error-detection AUROC by up to 0.146 and reversed the relative ranking of UE methods. The LLM-judge also selectively accepted invalid or uncertain outputs, accepting 16 of 30 such human-identified errors. These results demonstrate that correctness assessment is an integral component of clinical UE evaluation and should be validated before UE methods are compared.

Comment
5 pages, 3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Does Model Uncertainty Track Human Ambiguity? Evidence from Multi-Annotator Vision Benchmarks

cs.AI ·2026-09-28 ·Manya Singh, Arjun Pakrashi
similarity 0.68
Abstract

Human-model alignment is critical for trustworthy AI-assisted decision-making systems. Yet, most work evaluates model predictions against single ground-truth labels, overlooking that humans themselves often disagree on labels, a signal of genuine ambiguity. We investigate whether models struggle on the same instances that humans find difficult. We measure this on two vision datasets (FER+ and CIFAR-10H) where multiple human annotations per image capture human disagreement patterns. We evaluate eight pretrained models across three architectures (ResNet, EfficientNet, MobileNetV3) in two parts: first, whether model uncertainty (softmax confidence, entropy) correlates with human disagreement, and second, whether predictive multiplicity measures (inter-model disagreement, Jensen-Shannon divergence) do. We find that it does not: alignment is weak in both dimensions. At the discrete label level, 50.4% of CIFAR-10H images and 33.5% of FER+ images receive multiple valid classifications from humans, while the models converge on only one. These instances represent a critical failure case where humans perceive ambiguity and would request expert review, yet models decide confidently. At the continuous score level, single-model uncertainty correlates weakly with human disagreement ($ρ= 0.24--0.55$), and predictive multiplicity provides only modest improvement. Widely-used uncertainty quantification methods do not reliably identify instances humans find ambiguous. Model uncertainty should not be treated as a trustworthy signal by default for decision-making in high-stakes scenarios.

0.38

RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching

cs.CV ·2026-09-01 ·Charles Corbière, Léo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron +1 more
publishedcode/data similarity 0.66
Abstract · Accepted to ECCV 2026 Workshop on Medical Foundation Models and Benchmarks

As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language model (LLM)-based metrics are now the best-correlated with radiologist judgment, yet they output a single opaque score that neither a clinician nor a model builder can easily interpret or audit. We introduce RadMatch, a multi-stage, LLM-based metric that decomposes report comparison into a structured finding-level matching with significance-aware scoring and error characterization across seven clinical attribute dimensions (status, location, severity, morphology, certainty, longitudinal comparison, and measurement). The main score is the actionable-error count, both interpretable and auditable. Candidate findings are graded correct, partial, or incorrect, and unmatched findings are counted as missed or hallucinated. Triage and actionable safety recall/precision and per-subset views add complementary, deployment-oriented lenses. Across two expert benchmarks, RadMatch is the most clinically aligned metric, matching inter-radiologist agreement on ReXVal and more than doubling the best prior metric on the harder RadEvalExpert. Relying only on few-shot prompting, it is designed to extend to other modalities and anatomies. We will release RadMatch as open-source code with an interactive dashboard for inspecting results.

0.53

Beyond Accuracy: Benchmarking Uncertainty Quantification in Retinal Disease Screening

eess.IV ·2026-11-17 ·Mahvash Jebeli, Mohammad Eslami, Nazlee Zebardast, Lucia Sobrin, Tobias Elze
benchmarkdataset similarity 0.65
Abstract

Reliable uncertainty quantification (UQ) is essential for evaluating retinal AI systems beyond classification accuracy, yet it remains unclear whether existing UQ strategies generalize across diseases, model architectures, and reliability criteria. We introduce a large-scale, multi-disease benchmark comprising over $242,000$ fundus photographs from $32$ datasets covering diabetic retinopathy, age-related macular degeneration, and glaucoma. We evaluate six representative UQ strategies across three Vision Transformer configurations, assessing discrimination, probabilistic calibration, selective prediction, and conformal prediction-set coverage. Our findings reveal no universally superior model or UQ strategy: methods that improve reliability in one disease or architecture may underperform in another, while improvements in discrimination, calibration, and selective prediction do not necessarily align. Notably, computationally intensive methods do not consistently outperform simple confidence scores, and domain-specific foundation models and calibration-oriented loss functions do not guarantee greater reliability. In contrast, conformal prediction provides a complementary framework for achieving near-nominal marginal prediction-set coverage across diverse settings, subject to its statistical assumptions. These findings challenge universal UQ recommendations and highlight the need for disease-specific, model-specific, and multidimensional reliability evaluation before clinical deployment. We release standardized dataset splits, trained checkpoints, evaluation code, and an interactive research demonstration to support reproducible benchmarking.

0.06

ECG Mirage: Revealing and Mitigating the Underutilisation of ECGs in Vision-Language Models for Clinical Prediction

cs.AI ·2026-09-18 ·Jinning Liang, Mingcheng Zhu, Tingting Zhu
similarity 0.65
Abstract

Emergency department (ED) decision-making relies on heterogeneous clinical information, including patient history, vital signs, laboratory results, and electrocardiograms (ECGs). Vision--language models (VLMs) can jointly process these modalities, but strong predictive performance does not necessarily imply meaningful use of the correct patient's ECG. We term this failure mode ECG Mirage: apparent multimodal capability without useful dependence on patient-specific ECG information. We distinguish two forms: ECG neglect, where ECGs provide little predictive benefit, and ECG confusion, where matched ECGs outperform no-image inputs but not mismatched ECGs. To evaluate these behaviours, we compare predictions obtained with matched ECGs, outcome-discordant mismatched ECGs, and no-image inputs while holding the clinical text and prediction targets fixed. Across four VLMs on MDS-ED, matched ECGs provide no consistent advantage for either ICU admission or clinical deterioration prediction. We then train four restricted visual prompts using supervised learning followed by conditional direct preference optimisation, while keeping the VLM backbone frozen. The resulting models achieve balanced accuracies of 70.6% for ICU admission and 67.5% for deterioration and increase the matched-versus-mismatched performance gap to approximately 16.5 and 5.5 percentage points, respectively. Overall, our study identifies ECG Mirage in multimodal clinical prediction and introduces visual prompt tuning as an efficient mitigation strategy.

0.38

When Confidence Fails: Overconfidence in LLMs under Uncertainty and Missing Clinical Information

cs.CL cs.AIcs.HCcs.LG ·2026-08-10 ·Maryam Tahermazandarani, Adnan Mahmood, Fahmida Islam, Quan Z. Sheng
published similarity 0.65
Abstract

Large Language Models (LLMs) have achieved strong performance in medical question answering and clinical reasoning tasks. However, their reliability under uncertainty remains poorly understood which raises critical concerns for deployment in high-stakes clinical settings. In such environments, incorrect predictions are inherently risky, but confident incorrect predictions can be particularly harmful as they may mislead clinical decision-making. In this paper, we conduct a systematic behavioral analysis of LLMs under clinical information uncertainty. We propose an evaluation framework based on the MedMCQA dataset consisting of two complementary uncertainty settings. First, we introduce linguistic uncertainty cues through prompt modifications to simulate ambiguous clinical contexts. Second, we construct an answer removal setting, wherein the correct option is deliberately excluded mandating the model to recognize insufficient information and abstain. We analyze both model accuracy and confidence behavior using multiple calibration metrics including calibration gap, Expected Calibration Error (ECE), and Unsafe Confident Error Rate (UCER) across 500 medical questions. Our results reveal a consistent failure mode, i.e., although accuracy degrades under increasing uncertainty, model confidence remains misaligned with accuracy. This leads to a substantial increase in unsafe confident errors, indicating that model confidence remains largely insensitive to clinically meaningful information loss. Furthermore, we observe significant variation across models in their ability to abstain when the correct answer is unavailable, with some models persistently producing high confidence hallucinated answers. These findings expose critical limitations in the epistemic reliability of current LLMs and highlight the need for uncertainty aware evaluation methods prior to their deployment in clinical workflows.

0.22

Diagnostic Loss: Asymmetric Supervision for Radiology Report Generation

cs.CV cs.LG ·2026-10-22 ·Ignacy Kolton, Wenxuan Li, Zongwei Zhou, Jarosław B. Ćwikła, Arkadiusz Sitek +2 more
code/datahot direction similarity 0.65
Abstract · 26 pages, 6 figures, 7 tables. Code available at https://github.com/gmum/DLoss

Automated radiology report generation requires models to do more than produce fluent clinical narratives: they must explicitly state supported diagnoses while avoiding unsupported ones. However, existing medical vision-language models (MedVLMs) are typically trained with token-level maximum likelihood objectives, which prioritize text agreement over diagnostically critical terms. As a result, models can miss key diagnoses and introduce wrong ones. We identify this as an objective misalignment between conventional language modeling and the asymmetric diagnostic requirements of radiology reporting. To encode these requirements, we introduce Diagnostic Loss (DLoss), a differentiable, architecture-agnostic objective that operates directly on decoder token probabilities. DLoss separately aggregates probability mass over vocabularies associated with diagnoses supported by the reference report and with unsupported alternatives. Using asymmetric pooling across token positions in the report, it encourages supported diagnoses to receive sufficient probability in at least one position while suppressing spurious probability spikes for unsupported diagnoses across all positions during training. The loss can be applied to existing 3D MedVLMs without modifying their vision backbones, language decoders, or inference procedures, and introduces no additional inference-time computation. We train and evaluate DLoss on 50,000 abdominal CT scans across several 3D MedVLM architectures on both in-distribution and out-of-distribution report-generation benchmarks. Across these settings, DLoss improves diagnostic faithfulness while maintaining competitive performance on conventional language-generation metrics, showing the value of asymmetric sequence-level supervision for radiology report generation. The code for DLoss is available at https://github.com/gmum/DLoss.

0.40

RxScribe Bench: A Multi-Axis Benchmark for Evaluating Vision-Language Models on Indian Outpatient Prescriptions

cs.CV ·2026-09-08 ·Somil, Vijay Saini, Vidit Verma, Riya, Aastha Batta +4 more
benchmark similarity 0.65
Abstract

Prescription transcription errors are not interchangeable. A model that fabricates a drug and a model that misreads a legible dose pose very different clinical risks, yet prescription-transcription accuracy is typically reported as a single blended figure that treats the two as equivalent. We introduce RxScribe Bench, a benchmark for evaluating vision-language models on handwritten prescription digitization that decomposes performance into four axes tied to clinical severity, rather than folding everything into a single aggregated score. Given only a prescription image and an output schema, a model produces a structured record, which is then compared field by field against a human-authored ground truth of identical shape, with each field also labeled for visibility and legibility. The four axes isolate distinct failure modes, namely Correctness, Hallucination, Engagement, and Robustness. The Robustness axis withholds its hard-field results rather than reporting one when the supporting sample falls below a minimum-evidence threshold. We evaluate frontier vision-language models on real prescriptions across independent cold runs per image, and find that no single model wins across all four axes.

0.14

Visually Irrelevant Hallucinations in Medical Vision-Language Models

cs.CV ·2026-10-28 ·Ke Zou, Nan Zhou, Tao Yang, Meng Liu, Linchao He +7 more
benchmark similarity 0.64
Abstract

Medical vision-language models (VLMs) show strong performance in radiology report generation (RRG) and medical visual question answering (Med-VQA), producing free-form clinical descriptions and answers from medical images. However, they may generate clinically meaningful statements that lack visual evidence or contradict image content. We refer to these errors as visually irrelevant hallucinations and investigate them at the phrase level. We propose CLEAR (Counterfactual Localized Evaluation of Alignment and Response), a model-agnostic post-hoc framework for phrase-level hallucination risk estimation. CLEAR decomposes generated responses into visually assessable clinical phrases. For each phrase, phrase-conditioned grounding identifies a candidate visual region, which is selectively perturbed by a localized counterfactual intervention. CLEAR characterizes the intervention using two complementary auditing cues: response cues, capturing semantic and clinically meaningful changes in the generated response, and alignment cues, measuring changes in image-phrase compatibility. These cues are normalized and jointly modeled to estimate phrase-level hallucination risk. Across four datasets spanning RRG and Med-VQA, CLEAR outperforms state-of-the-art hallucination detection baselines across multiple medical and general-purpose VLMs. On MIMIC-CXR, CLEAR improves AUPRC from 85.10% to 90.23%. Its effectiveness is further validated on a GT-derived controlled VIH benchmark. These results establish visually irrelevant hallucination as an important fine-grained reliability failure mode in medical VLMs and demonstrate the value of model-agnostic visual-support auditing for more trustworthy multimodal clinical generation.

0.06