CS Paper Radar

MedPCFM-TED: One-Step Point Cloud Flow Matching for Implant Generation via Teacher-Guided Endpoint Distillation

Kamil Kwarciak, Marek Wodzinski

cs.CV cs.LG ·submitted 2026-09-15 10:10 UTC · v1

Abstract

Cranial implant generation is an important task in medical imaging. Recent point cloud based generative methods, particularly flow matching, offer strong reconstruction quality and efficient sampling, but still require multiple neural function evaluations during inference. This limits rapid generation of multiple plausible implant candidates. We propose Teacher-guided Endpoint Distillation (TED), a simple one-step distillation framework for conditional cranial implant generation on point clouds. TED trains a one-step student using teacher-guided endpoint supervision and geometric matching losses, while avoiding explicit path straightening. We evaluate TED on the SkullFix and SkullBreak benchmarks. TED achieves the best overall performance on the SkullBreak dataset, remains competitive on SkullFix, and provides the strongest Chamfer distance performance among the compared one-step methods. In addition, TED generates implants in approximately 0.04s per sample. These results show that one-step distillation can substantially accelerate conditional point cloud implant generation without sacrificing reconstruction quality.

Comment
10 pages, 3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-Guided Flow Matching for CT Image Reconstruction

cs.AI cs.CV ·2026-08-28 ·Davide Evangelista
similarity 0.61
Abstract · 16 pages, 6 figures, 2 tables

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

0.41

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.59
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.13

OTT3R: Multi-View 3D Reconstruction and Fast Dataset Generation at 1% Compute

cs.CV ·2026-09-28 ·Brandon Leblanc, Charalambos Poullis
publishedcode/data similarity 0.58
Abstract · Accepted at ACCV 2026

Feed-forward 3D reconstruction models have achieved impressive performance by scaling model and dataset size, but their cost excludes most research groups and precludes edge deployment. Additionally, generating 3D supervision without sensors still relies on slow, unreliable Structure-from-Motion, as the community lacks a COLMAP-like system for neural 3D pseudo-label generation. We present OTT3R (RGB-Only Tiny Transformer for 3D Reconstruction), a knowledge distillation framework that addresses both problems on a single workstation equipped with 2 GPUs. Distilling $π^3$ (959M parameters) into a 102M-parameter student yields 9.4$\times$ compression and up to 7$\times$ faster inference, trained at 1.6% of VGGT's training compute. An integrated pseudo-label pipeline offers a reliable, high-throughput alternative to COLMAP, generating dense per-pixel point maps and SE(3) camera poses for a 667K-image corpus in 3.5 hours on two commodity GPUs and succeeding on every sequence we tested, including those where COLMAP fails. The general student tracks the teacher on in-distribution monocular depth and, zero-shot, outperforms COLMAP on 7-Scenes and on DTU completion, but it does not replace the teacher on out-of-distribution multi-view geometry. The deployable artifact is the domain-specialized student: after specialization at 0.2% compute, it is 4$\times$ more accurate than COLMAP on 7-Scenes at 980$\times$ throughput, with near-teacher completion. Code is available at https://github.com/TheFourthKaramazov/OTT3R

0.43

Few-Step Generation via Data-Space Iteration

cs.LG cs.CV ·2026-10-08 ·Shanchuan Lin, Yansong Peng, Fu-Yun Wang, Haoqi Fan
similarity 0.58
Abstract

Flow matching has emerged as a scalable paradigm for training high-quality generative models, but sampling from the learned probability flow requires many network evaluations. Distillation can reduce this cost to one or a few evaluations; however, one-step generation often sacrifices quality, making few-step generation the practical operating regime. Existing few-step methods perform their iterative computation along the probability flow and therefore require a fixed, manually chosen timestep discretization. This discretization is often chosen heuristically and is expensive to tune; it may also be restrictive when refinement difficulty differs across samples or spatial locations. We introduce data-space iteration, a few-step generation framework that removes flow discretization altogether. Starting from noise, a shared generator directly refines its prediction in data space, with every iteration trained to produce the best sample permitted by its capacity. Our formulation integrates with distribution matching distillation (DMD) with minimal changes, enabling a controlled comparison between iteration methods under matched training settings. On class-conditional ImageNet 256x256, data-space iteration outperforms standard discretization baselines and matches or improves upon variants selected through schedule search, without requiring schedule-specific training. These results show that data-space iteration provides a simple and effective alternative to discretized flow-space iteration for fast generation.

0.15

Biomechanical 3D Body: Self-Supervised Distillation of Biomechanical Pose from a 3D Body Foundation Model

cs.CV ·2026-08-30 ·R. James Cotton, J. D. Peiffer, Lucinda Williamson, John Leske, Georgios Pavlakos
publishedcode/data similarity 0.58
Abstract · Accepted to the ECCV 2026 Workshop MoCha

State-of-the-art monocular body recovery methods predict mesh vertices and angles on the corresponding kinematic tree, but their outputs lack biomechanically defined joint angles that downstream applications like clinical and biomechanical analyses require. We extend an existing foundation model, SAM-3D-Body, with an additional biomechanical prediction head that, from a single RGB image, regresses the joint angles and scales of a biomechanical model. Training this model presents a challenge, as there are limited datasets of paired images and biomechanical fits. To overcome this, we supervise biomechanical outputs with in-loop optimized targets from a Levenberg-Marquardt solver performing inverse kinematics fits against markers from the mesh predictions. This allows distilling the biomechanical head from the mesh head, even from unlabeled images. To make this work with GPU-optimized biomechanical models in MuJoCo, the entire model was implemented in JAX using Equinox. We trained this distilled output head on the publicly released SAM-3D-Body dataset. We then validated this model on biomechanical fits to two publicly available marker-based datasets, MoVi and BioCV, as well as movements from a clinical cohort captured with multiview markerless motion capture. The resulting model outperforms existing models for direct regression of biomechanics from images while only slightly underperforming the state-of-the-art monocular biomechanics method that performs more costly inference-time optimization of entire trajectories.

0.51

UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound

cs.CV eess.IV ·2026-09-10 ·Weiying Chen, Yuchong Gao, Siyuan Li, Marek Reformat, Rui Zheng +1 more
top venue similarity 0.57
Abstract · Accepted to ECCV 2026. Camera-ready Author Version

Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines.

0.40

Consistent Distribution Matching for Data-Free Diffusion Distillation

cs.LG cs.AIcs.CV ·2026-10-06 ·Yuxiang Fu, Qi Yan, Zike Wu, Yongxing Zhang, Purang Abolmaesumi +2 more
theorycode/data similarity 0.57
Abstract

Flow and diffusion models suffer from slow inference due to computationally expensive numerical integration. Distillation provides a promising way for a student model to learn from a teacher's dynamics, enabling one-step or few-step generation. However, existing methods often depend on curated distillation datasets, costly teacher rollouts, or auxiliary proxy networks, which complicate model training and scaling. In this work, we propose Consistent Distribution Matching, a simulation-free and data-free distillation method for accelerating diffusion and flow models while preserving strong generative capacity. Our key insight is to unify sample generation and score estimation with one student network. Thus, our framework uses only two models, a frozen teacher and a trainable student, and optimizes one objective. We prove that minimizing our objective indicates Wasserstein convergence of the student flow-map pushforwards to the teacher marginals. On ImageNet 256$\times$256, our method attains an FID of 2.04 with a single function evaluation (1-NFE) and a 4-NFE FID of 1.37 within 40 epochs of training, surpassing the state-of-the-art distillation baselines without data. Our code code and model are available at https://consistentdmd.github.io/.

0.45

Uni-Light: An Ultra-Lightweight Framework via Uncertainty-Aware Knowledge Distillation for Brain Tumour Segmentation

cs.CV ·2026-09-06 ·Libing Kuang, Soren Salehi, Ziling Wu, Ahmad P. Tafti, Armaghan Moemeni
similarity 0.57
Abstract

Accurate 3D brain tumour segmentation from multi-modal Magnetic Resonance Imaging (MRI) is essential for clinical diagnosis and treatment planning. Existing brain tumour segmentation methods often suffer from heavy computational demands, while current lightweight architectures frequently lack the capacity to maintain segmentation fidelity in complex tumour regions. To address these issues, we propose a novel ultra-lightweight framework (Uni-Light) that achieves high-fidelity segmentation with substantially reduced computational overhead. It combines multi-scale convolutions with an uncertainty-aware knowledge distillation scheme that directs the student model toward hard-to-classify regions, complemented by a Signed Distance Field boundary loss for geometric constraints. Experimental results on BraTS2023-GLI and MSD-BTS datasets demonstrate that Uni-Light reduces parameters by 97.56%, floating-point operations (FLOPs) by 73.03%, and inference memory footprint by 81.58%, while surpassing the state-of-the-art model by an average of 1.47% in Dice score, offering a highly competitive trade-off between segmentation accuracy and computational efficiency in resource-constrained clinical settings. This work also advances data engineering for medical imaging by demonstrating that teacher model uncertainty can be exploited as a data-driven supervisory signal, re-prioritising the training data distribution without requiring additional annotation.

0.24