CS Paper Radar

Multi-Appliance Non-Intrusive Load Monitoring via Label-Preserving Aggregate Recomposition and Prediction Consistency

Jiangfeng Liu, Yanfang Fan

cs.LG ·submitted 2026-09-16 08:35 UTC · v1

Abstract

Non-intrusive load monitoring (NILM) estimates appliance power sequences from aggregate power, but models trained on source households commonly lose accuracy in unseen households. Aggregate power also contains loads from other appliances and measurement error, so predictions may depend on the residual background that co-occurs with source-household targets. Time-aligned submetered measurements and the additive decomposition of aggregate power expose a relation unused by window-wise supervision: an aggregate window can be recomposed by replacing only its residual background while preserving all modeled target-appliance power sequences pointwise. We combine label-preserving aggregate recomposition with prediction consistency. Both windows receive complete power and operating-state supervision. For each appliance, disagreement between the two power predictions is penalized only when both satisfy a fixed reliability criterion and only to the extent that it exceeds a fixed margin. The proposed method is implemented using a multi-appliance architecture with two-stage shared-to-specific mixture-of-experts routing. On REDD, UK-DALE, and REFIT, the proposed method lowers appliance-averaged mean absolute error relative to single-window training from 14.75 to 13.14 W, from 8.88 to 8.51 W, and from 15.83 to 14.55 W. Label-preserving aggregate recomposition and prediction consistency are used only during training, and add no inference-time module or parameter.

Closest papers

Nearest neighbours by meaning across the whole index.

Ask for Any Appliance: A Prompt-Programmable Foundation Model for Non-Intrusive Load Monitoring

cs.LG eess.SP ·2026-09-19 ·Xudong Wang, Jiacheng Cui, Junyu Xue, Tongxin Li, Guoming Tang
similarity 0.76
Abstract · Preprint

Non-intrusive load monitoring (NILM) estimates appliance-level consumption from a whole-home meter, but appliance-specific models and fixed output inventories make coverage costly to extend. We present FM4NILM (Foundation Model for NILM), a single prompt-programmable model that estimates a requested appliance's power trajectory from aggregate measurements, a natural-language description, and optional activation exemplars. A lightweight cadence-aware transformer is pretrained by masked reconstruction on 645k sequences from seven public corpora spanning 1-60 s sampling intervals, then aligned with appliance requests using observation-masked losses for partially labeled households. A Bernoulli-lognormal decoder separates activity detection from conditional power estimation. On held-out households and time periods from REDD, UK-DALE, and REFIT, one frozen text-prompted model serves twelve appliance-corpus requests, achieving 0.556 event F1, 0.625 AUPRC, and the lowest active-window MAE (251.8 W) among seven appliance-specific baselines. Streaming score aggregation raises event F1 to 0.582 with a 60 s aggregation delay. In a separate category-held-out evaluation, adding ten activation exemplars raises microwave AUPRC from 0.132 to 0.214 without parameter updates. Input-intervention ablations probe the model's dependence on appliance requests and aggregate measurements. These results demonstrate competitive disaggregation with one shared model and support extending appliance coverage through prompts and examples rather than additional specialist networks.

0.10

Non-intrusive appliance state detection in unseen homes using classical machine learning

cs.LG eess.SP ·2026-10-31 ·Zablon Ombiro
similarity 0.71
Abstract · 49 pages, 9 figures

Non-intrusive load monitoring (NILM) infers, from the aggregate signal of a single smart meter, when each appliance in a home is ON or OFF, offering significant potential to enhance energy efficiency. Classical machine-learning detectors report F1 scores (the harmonic mean of precision and recall) from 0.53 to 0.98, but the causes of this spread are unseparated, so it is unclear which design choices matter. Real-world deployments, however, require detectors that work in houses never seen during training, whereas most studies test on houses used for training. To address this challenge, we propose a factorial analysis of variance design that separates the effects of classifier, feature set and class-imbalance strategy across five appliances (270 configurations), and a leave-house-out protocol with house-grouped model selection. Unlike studies that vary one factor at a time or pool houses, the approach attributes performance to each factor and measures it on unseen homes. Extensive experiments on REFIT, a public dataset of 20 UK households, show that the appliance explains 38 percent of F1 variance, the feature set 13 percent, the classifier 8 percent and the imbalance strategy 2 percent. Pooled testing overstates support-weighted F1 (0.548 versus 0.447 in unseen houses), class weighting gains grow from 32 percent to 69 percent, and feature engineering gives the same 52 percent gain in both protocols. House-grouped selection raises F1 for three of five appliances, by up to 0.110, and a convolutional neural network scores 0.450 (0.496 calibrated) against 0.447 for classical models. The findings guide appliance-level monitoring in smart-metering and energy-management systems.

0.19

Questionnaire-Guided Disaggregation of Energy Appliance Use for Domestic Smart Meter Data

cs.AI ·2026-10-01 ·Achal Nanjundamurthy, Rupam Misra, Suzanne Little, Alan F. Smeaton
similarity 0.71
Abstract

Ireland's smart metering programme records electricity use at 30-minute resolution, with smart meters installed in over 80\% of households as of late 2025. While this is useful for billing of smart, time-of-use tariffs, it is too coarse to capture use of domestic appliances. We present a label-free disaggregation system that breaks usage data into 9 appliance categories by combining event detection for high-power loads with questionnaire-guided estimation. Our evaluation draws on four datasets: a calibration household with a commercial comparator, two public benchmarks (UK-DALE and REFIT) with per-appliance sub-metering, and a smart meter dataset of more than 4,800 years of use from 2,968 Irish consumers. Compared against two independently developed disaggregation systems our hybrid method combining analysis of usage data with questionnaire results, achieves the lowest whole-decomposition error on all buildings across the datasets, with better month-level performance over 54 paired months ($p<0.001$, Holm-corrected). Our method provides useful advice on a household's energy consumption patterns and advice on how to reduce or shift usage on some appliances in order to reduce costs.

0.07

ReCo: When to Relocate Sensor Kits under Deployment Constraints -- A NILM Case Study

cs.LG ·2026-09-28 ·Haokun Chen, Yu Tong, Yehai Chen
similarity 0.68
Abstract · 8 pages, 3 figures, 6 tables

Many sensing tasks obtain training labels only by deploying instruments in the field. With a limited number of sensor kits, a collection deadline, and measurement downtime at every move, the collector must repeatedly decide whether to stay at the current site or relocate. We study this decision in non-intrusive load monitoring (NILM), which estimates the power drawn by individual appliances from a home's main meter and is trained on data from homes temporarily fitted with appliance-level sub-meters. In NILM, appliance usage varies with the appliance, season and climate, and the value of new data depends on how diverse the combinations of target operation and background load are. To address this, we propose a constraint-based relocation framework and instantiate it for NILM as ReCo (Relocation by Coverage gain). ReCo counts new operating regimes in a joint target-background feature space, forecasts each home's future gain from the data collected so far, and each night weighs the gain of staying against the gain of moving elsewhere after the downtime. In replayed deployments on the Plegma dataset under two kit counts and two downtime costs, ReCo outperforms fixed-dwell and count-based schedules and a threshold rule using the same metric in every setting. Its advantage is not explained by collecting more days alone and reflects allocating the days to more valuable homes and periods.

0.18

Lightweight Low-Frequency Non-Intrusive Load Monitoring via Karhunen-Loève Feature Distillation and Temporal Convolutional Networks

eess.SP cs.LGeess.SY ·2026-11-19 ·Sanka Peeris, Pandula Thennakoon, Praveen Sumanasekara, Roshan Godaliyadda, Parakrama Ekanayake +1 more
similarity 0.66
Abstract · 10 pages, 6 figures. Submitted to IEEE Transactions on Smart Grid. S. Peeris, P. Thennakoon and P. Sumanasekara contributed equally

Non-Intrusive Load Monitoring (NILM) is a critical enabler for demand-side management which allows for smart grid optimization. A deployment-ready NILM solution necessitates three key features: accurate disaggregation, low-frequency sampling, and low computational cost. This paper proposes a lightweight, edge-oriented NILM framework that combines activity-boundary-aware synthetic data augmentation with Karhunen-Loève Transform (KLT) feature extraction and a Temporal Convolutional Network (TCN). The augmentation stage extracts and recombines complete or near-complete appliance activation segments so that the model can be trained without new fully labeled household aggregates. The KLT filter bank extracts decorrelated, appliance-informed temporal features which are then fed into a compact TCN along with the original aggregate for energy disaggregation. Evaluations on two standard NILM datasets, UK-DALE and REDD, at 10-s sampling and with leave-one-house-out testing, demonstrate that the proposed architecture achieves comparable or superior disaggregation accuracy relative to NILMFormer, BERT4NILM, BiLSTM, and BiGRU. The computational footprint of the framework is 31,009 parameters, the fewest of the five models compared, and on a single CPU thread it needs 2.78 ms per 1000 samples, 84-95% less than the baselines. These results demonstrate a favorable accuracy-efficiency tradeoff for low-frequency smart-meter NILM.

0.23

LoaDiff: Conditional Generation of Electricity Consumption Time Series for Energy Analytics

cs.LG cs.AIeess.SP ·2026-09-10 ·Mariia Baranova, Adrien Petralia, Etienne Le Naour, Nathan Etourneau, Guillaume Hofmann +1 more
top venue similarity 0.65
Abstract · 10 pages, 5 figures. This paper appeared in IEEE ICDM 2026

The energy transition is reshaping residential electricity consumption through the increasing adoption of distributed generation, electrified appliances, and demand-response programs. Understanding these evolving behaviors requires access to granular smart-meter data for applications such as load forecasting, appliance detection, and demand-side flexibility analysis. However, such data are subject to strict access restrictions and data-protection regulations. Thus, realistic synthetic alternatives are necessary. In this paper, we introduce LoaDiff, a diffusion-based generative model for year-long, sub-hourly smart-meter load curves. LoaDiff supports flexible conditioning on static household attributes, such as appliance ownership, and dynamic contextual variables, including calendar information and outdoor temperature. We evaluate the model against multiple generative baselines on three residential electricity-consumption datasets. Our experiments assess four complementary dimensions: fidelity and diversity, training-record memorization risk, downstream utility for load forecasting and appliance detection, and conditional controllability under alternative temperature conditions. The results show that LoaDiff generates realistic and diverse load profiles, achieves a favorable trade-off between generation quality and limited evidence of memorization, preserves information useful for downstream energy applications, and responds coherently to changes in conditioning variables.

0.44

A Real-Time Tsetlin Machine-based Non-intrusive Load Monitoring System on MCUs

cs.LG ·2026-08-19 ·Han Wu, Tianhang Tan, Shengyu Duan, Alex Yakovlev, Rishad Shafik +1 more
published similarity 0.61
Abstract · Accepted by International Symposium on the Tsetlin Machine (ISTM 2026)

Non-Intrusive Load Monitoring (NILM) systems estimate individual appliance energy consumption from a single aggregate meter, without requiring separate sensors for each device. By installing a single meter that measures a building's total electricity consumption, NILM algorithms can determine the active status of each appliance. However, traditional NILM systems use computationally intensive optimization algorithms to process offline data, limiting their capability for on-device deployment, where sensitive household data must be processed locally. This paper proposes a Tsetlin Machine (TM)-based NILM framework, targeting real-time applications on resource-constrained microcontrollers (MCUs), enabling privacy-preserving edge deployment. The problem is reformulated as a classification task, and the proposed approach achieves an average precision of 90% and recall of 96% for two-appliance classification, and 77% precision and 80% recall for four appliances on the REDD dataset. The trained model occupies only 17 KB of flash memory and achieves an inference latency of 0.43 ms on an ESP32, demonstrating its suitability for NILM applications on MCUs.

0.33

Learning Defensive Policies against Diverse Inference Attacks for Smart Meter Privacy

cs.LG ·2026-09-21 ·Ruichang Zhang, Mustafa A. Mustafa
similarity 0.61
Abstract

Smart meter (SM) data provides fine-grained visibility into household energy consumption, but also exposes users to privacy risks. Inference attacks, known as non-intrusive load monitoring (NILM), can perform appliance-level inference from aggregate signals and recover sensitive behavioral patterns. In practice, attacker models are unknown and heterogeneous, making robust defense challenging. We formulate SM privacy protection as a black-box inference defense problem, aiming to reduce the recoverability of appliance-level information while generalizing across diverse and unseen attackers. We propose a proxy-guided hierarchical reinforcement learning framework that learns battery-based load-shaping policies to inject realistic but misleading appliance-level signatures into the aggregate signal, thereby disrupting the structured patterns exploited by NILM. A self-supervised aggregate-structure privacy probe provides a reconstruction-error-based surrogate reward for disrupting recoverable load structure, while a signature library makes the perturbations appliance-relevant and physically realizable through battery control. We provide theoretical rationale showing that proxy-guided optimization improves inference robustness under attacker diversity. Experiments on real-world datasets UK-DALE and REDD demonstrate strong cross-model and cross-appliance generalization. Across six unseen NILM attackers, covering four appliances on UK-DALE and five on REDD, our proposed defense increases average appliance-level RMSE by 107% and 166%, respectively, while reducing F1 score by 79% and 80%.

0.16