CS Paper Radar

Flash-Radiomics: A Scalable Hybrid CPU-CUDA Engine for Standardized Scalar Radiomics and Accelerated Spatial Mapping

Shanli Ding, Yiyi Hu, Ziyu Fu, Chia-Hsin Lin, Ruihan Luo, Jaehee Chun, Xinyue Zhang, Osama Mawlawi

cs.MS q-bio.OTeess.IVphysics.med-ph ·submitted 2026-09-15 19:54 UTC · v1

Abstract

Background and Objectives: Spatial mapping retains the spatial distribution of radiomic features, but computational cost and fragmented software limit its use. We developed Flash-Radiomics with scalar extraction and spatial mapping, a central processing unit (CPU) backend, a hybrid Compute Unified Device Architecture (CUDA) backend, consistent feature names, and Hierarchical Data Format version 5 (HDF5) storage. Methods: We evaluated Image Biomarker Standardisation Initiative (IBSI) compliance, CPU-CUDA concordance, and end-to-end processing time. Compliance testing included 825 chapter 1 (IBSI-1) tests covering 165 high-consensus features and 323 chapter 2 (IBSI-2) tests with numerical references. Concordance testing included 1,148 scalar pairs and 93 spatial-map pairs. End-to-end processing time was measured five times per input volume of interest (VOI) size. Comparisons included the Medical Image Radiomics Processor (MIRP) and PyRadiomics for 102 shared scalar features and PyRadiomics for 93 shared spatial maps. Results: Both backends passed all 1,148 IBSI tests, and all paired results were concordant. At the largest scalar input, CPU required 76.343 s and hybrid CUDA 81.915 s; CPU was 4.7 times faster than MIRP and 190.7 times faster than PyRadiomics. At the largest spatial input completed by both backends, hybrid CUDA reduced processing time by 68.6% relative to CPU (79.280 versus 252.791 s). At PyRadiomics' largest completed spatial input, hybrid CUDA was 84.9 times faster. Conclusions: Flash-Radiomics unified standardized scalar extraction, spatial mapping, concordant CPU-CUDA results, and HDF5 storage. CPU processing time was similar or shorter for scalar extraction, whereas hybrid CUDA was faster for spatial mapping under the tested conditions.

Comment
20 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

GPUPHOT: A Python Framework for High-Performance GPU-Accelerated Photometry and Distributed Astronomical Data Reduction

cs.DC astro-ph.IM ·2026-09-26 ·Samuel Lemes-Perera, Miguel R. Alarcon, Miquel Serra-Ricart, Pino Caballero-Gil
benchmarkcode/data similarity 0.60
Abstract · 39 pages, 8 figures. Submitted to Astronomy and Computing

We present GPUPHOT, an open-source Python framework for GPU-accelerated real-time photometry and astrometry of astronomical CCD and scientific CMOS images. Four of its seven stages run entirely on the GPU through CuPy (background estimation, source detection, PSF modeling and aperture photometry); the catalog crossmatch selects a CPU or GPU backend by problem size, and the zero-point and astrometric calibrations run on the CPU, within a containerized distributed system. Checkpoint-based GPU memory monitoring and an opt-in spatial-binning fallback let a single container image run on GPUs from a 4 GB laptop card to 80 GB datacenter accelerators. We benchmark the framework on nineteen observations from two robotic facilities, the Two-meter Twin Telescope and the Transient Survey Telescope, spanning 4.2 to 151.2 megapixels and 228 to 134,206 cataloged sources, on eight NVIDIA GPU platforms with one process per image. The H100 completes the densest 151.2-megapixel field end-to-end in 31.9 s, and GPU source detection on the A100 is 6-15x faster than the CPU library sep on the same frames. Once three sources of non-determinism are pinned, catalogs and zero points agree to the fourth decimal across GPU models and host CPUs. In this one-process-per-image regime the CuPy 14 / cuML stack showed a 7% lower peak memory and a median 38% higher per-image latency than CuPy 12, both due to the RAPIDS allocator displacing the CuPy memory pool at import; restoring the pool removes the memory difference and cuts the median overhead on datacenter GPUs to 11%, with identical output. Long-lived workers, the production mode, run the two stacks near parity. We recommend the CuPy 14 stack for its reproducibility and maintained libraries, not for memory or speed. GPUPHOT and its benchmark scripts are released for autonomous facilities that require end-to-end photometric reduction at survey cadence.

0.47

Reference Manual of MEDiml

cs.SE physics.med-ph ·2026-10-21 ·Mahdi Ait Lhaj Loutfi, Simon Provost, Élodie Gillard, Moustafa Amine Bezzahi, Alexander Chum +11 more
code/data similarity 0.57
Abstract · 39 pages, 18 figures, 2 tables. Software, documentation, tutorials, and all software resources are available at https://www.mediml.app

Radiomics is the high-throughput extraction of quantitative features (e.g., tumor shape, intensity distributions, and texture) from medical images to characterize tissues and uncover disease patterns invisible to the human eye. These features can serve as candidate imaging biomarkers for cancer diagnosis, prognosis, and classification. However, extracting thousands of features makes it difficult to identify the most informative ones for a given clinical task, while implementing an end-to-end workflow can require programming expertise that limits accessibility for clinical researchers. Hence, we propose MEDiml, an open-source, standards-compliant radiomics platform connecting feature extraction, predictive modeling, and interpretation through complementary graphical and programmatic interfaces. MEDiml combines a Python package (MEDiml-pkg) with a graphical desktop application (MEDiml-app) that enables researchers to conduct experiments without writing code. Both interfaces use the same computational implementation, and code generation exports graphically configured workflows as executable Python code, facilitating reproducibility and collaboration between clinical researchers and computational scientists. A typical MEDiml workflow includes image preprocessing, radiomic feature extraction, feature set reduction, model training and evaluation, and interpretation using feature importance. Feature sets can be grouped into levels of radiomic complexity (morphological, intensity-based, textural, and filter-based) to evaluate whether more complex features provide additional predictive value. This reference manual documents the radiomics concepts, workflow, software components, architecture, and installation, compares MEDiml with existing tools, and demonstrates its complexity-driven workflow on five oncological imaging cohorts comprising 2,104 patients. Resources: www.mediml.app.

0.35

Medical Image Analysis with Machine Learning (MEDiml): Strategies for Simpler Radiomics

eess.IV physics.med-ph ·2026-10-27 ·Mahdi Ait Lhaj Loutfi, Simon Provost, Élodie Gillard, Moustafa Amine Bezzahi, Alexander Chum +11 more
code/data similarity 0.57
Abstract · 11 pages, 3 figures, 2 tables. Software paper. Full reference manual: arXiv:2610.29666 . Software, documentation, tutorials, and resources a…

Radiomics extracts quantitative features describing tumor shape, intensity, and texture from medical images to build models that predict clinical outcomes. However, large feature sets increase the risk of overfitting in small datasets, and building an end-to-end workflow often requires programming expertise. We present MEDiml (Medical Image Analysis with Machine Learning), open-source radiomics software available as a Python package (MEDiml-pkg) and a no-code desktop application (MEDiml-app). Both run on the same computational engine, and code generation exports graphically configured workflows as executable Python code. Feature extraction follows the Image Biomarker Standardization Initiative (IBSI) standards. MEDiml is built around complexity minimization: features are grouped into levels of increasing complexity (morphological, intensity, textural,l and filter-based), a model is trained at each level, and the simplest level not significantly outperformed by more complex ones is retained. Applied to five oncological datasets (2,104 scans), MEDiml achieved AUCs of 0.65 to 0.82, with morphological or intensity features sufficient in four of the five tasks. Resources: www.mediml.app.

0.28

Towards Democratising Low-Data Medical Image Classification: CPU-Trainable ZACH-ViT and Its Geometric Variants

cs.CV cs.LG ·2026-11-12 ·Athanasios Angelakis
similarity 0.57
Abstract · 17 pages, 4 figures

Medical image classification in resource-constrained settings must contend with limited annotations and computational capacity. We evaluate four ZACH-ViT variants with linear, Euclidean prototype, Poincare and spherical heads alongside two compact multiple-instance-learning baselines. All models are trained from scratch with fewer than 260,000 parameters across seven MedMNIST+ datasets and three external benchmarks (PCam, ISIC2017 and Shenzhen tuberculosis radiographs). The low-data protocol uses 50 training images per class and five seeds, with validation-selected checkpoints at 23 and 47 epochs; a full-data reference uses one seed. Compact-TransMIL achieves the highest ten-dataset mean test Macro-F1 at 23 epochs (53.34%) and with full data (73.93%). At 47 epochs, ZACH-Linear narrowly leads (57.76% versus 57.54% for Compact-TransMIL). Extending training improves Macro-F1 in 239 of 300 paired comparisons. On ISIC2017, hZACH-Spherical has the highest 47-epoch low-data Macro-F1 (44.09% with SD 4.09%), whereas ZACH-EuclideanProto leads with full data (51.27%). We additionally conduct 40 CPU-only training runs on ISIC2017 and Shenzhen using four CPU threads; model-only single-image inference requires approximately 4-9 ms, while image decoding and preprocessing substantially increase end-to-end latency. The results demonstrate the feasibility of CPU-only training on the tested platform and the task- and regime-dependence of compact medical imaging under strict resource constraints.

0.18

Complementary Roles of Radiomics and Foundation Representations in Renal Cell Carcinoma Classification: A Comparative Study of 2D and 3D CT Encodings

cs.CV cs.AI ·2026-09-22 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
published similarity 0.56
Abstract · Accepted at Medical Image Understanding and Analysis (MIUA 2026). 15 pages, 2 figures

Accurate preoperative subtype classification of renal cell carcinoma (RCC) from contrast-enhanced computed tomography remains clinically challenging. Radiomics provides structured tumour descriptors, whereas foundation representations offer transferable image features. However, it remains unclear whether radiomics still adds value beyond pretrained representations, and how 2D and 3D MedVAE encoders compare in this setting. We compared handcrafted radiomics, 2D MedVAE, 3D MedVAE, and their fusion for binary clear-cell RCC versus non-clear-cell RCC classification on KiTS23 under a unified preprocessing pipeline. Concatenation, cross-attention, and gated fusion were evaluated as representative integration strategies, and radiomics feature importance was analysed to support decision-centric interpretability. Fusion consistently improved discrimination over image-only MedVAE branches. The best overall performance was achieved by 3D gated fusion, with an AUC of 82.7\%, outperforming the best 2D fusion model (79.6%), the radiomics baseline (74.4%), and the single-modality MedVAE branches. Ablation analysis further showed clear gains of the full fusion model over both image-only and radiomics-only variants, indicating complementary contributions from radiomics and image representations. These findings suggest that radiomics remains relevant for RCC CT classification in the presence of foundation representations, and that its integration with MedVAE is more effective in the 3D setting. More broadly, the study supports a complementary role for radiomics and foundation representations in clinically meaningful imaging decision support.

0.33

Characterizing CUDA Locality Domains on Blackwell GPUs

cs.DC ·2026-11-05 ·Rocky Wang, Joyce Zhou, Keith Jiang, Jason Zhao
similarity 0.55
Abstract

Low latency is critical to user experience. As NVIDIA Blackwell and Rubin GPUs advance multi-die scaling, data placement and cross-die communication become increasingly important. However, the latency implications and underlying costs of cross-die communication and die-aware execution remain largely unexplored. In this report, we present a comprehensive evaluation of the Locality Domain (LD) feature introduced in CUDA 13.4. Conducted on a single node equipped with eight NVIDIA B300 GPUs, our study examines three aspects: memory management and access, computation, and communication, to identify the sources of latency and, more importantly, explore how LD can mitigate them. Our measurements show that the benefits of LD depend on data access patterns. Through die-aware adaptations and integration with widely used libraries and tools, we achieve speedups of up to 43.5% for NCCL 2.32.3 (AllGather), 111.3% for nvbandwidth (DtoD), and 37% for DeepGEMM (EP). We also identify non-negligible LD-related GPU memory allocation overhead when allocation sizes exceed 32 MB due to barrier and TLB invalidation, we propose a fix to the GPU driver kernel module (submitted to NVIDIA) and show that overhead could be reduced 7x ~ 10x without requiring any user-code changes.

0.20

FastSAR: Open-Source SAR Image Formation on CPUs, GPUs, and TPUs, and a Matched Comparison of Algorithms, Precisions, and Processors

cs.PF eess.SP ·2026-10-24 ·Paul Singerman, Tom Braun
code/data similarity 0.54
Abstract · 39 pages, 8 figures. Submitted to IEEE Transactions on Geoscience and Remote Sensing. Code: https://github.com/saulpingerman/FastSAR (pip in…

The number of spaceborne synthetic aperture radar (SAR) collectors is growing exponentially, each returning raw collections that must be formed into images. Exact backprojection needs 1.6 trillion interpolated reads and 90 trillion floating-point operations for a 108-megapixel Umbra image. How long it takes to form an image, and at what price, depends on the algorithm, the arithmetic, and the hardware. Open-source implementations have never been compared on matched hardware against a common reference, and none run on Google tensor processing units (TPUs). This paper presents FastSAR, an open-source SAR image formation library for central processing units (CPUs), NVIDIA graphics processing units (GPUs), and TPUs. With it, we compare three SAR image formation algorithms, four floating-point formats, and six cloud devices in every supported combination, with cost per image at on-demand cloud prices as the fair common measure. FastSAR is 1.06 to 22,000 times faster than the tested open-source implementations at equal or better accuracy, and the full suite of hardware, algorithm, and floating-point combinations lets a user choose the Pareto-optimal configuration for their balance of accuracy, speed, and cost. The L4 GPU forms images the cheapest overall. Larger GPUs are faster but cost more per image because their price rises faster than their speed. The TPUs come close to the GPUs in cost, but only for the factorized algorithm, and the CPU is far less efficient in both speed and cost. Lower precision formats buy less of a speedup than expected, and each step down in precision costs accuracy.

0.37

OpenMidnight: Closing the Performance Gap Between Open and Proprietary Pathology Foundation Models

cs.CV ·2026-10-13 ·Ratna Sagari Grandhi, Anis Chihoub, Ryan Kim, Daniel Z. Kaplan, Chao Feng +13 more
code/data similarity 0.54
Abstract

Pathology foundation models offer transferable representations for a range of downstream tasks in computational pathology, but reliance on proprietary data, substantial compute requirements, and limited availability of training code and preprocessing pipelines hinder independent validation and further methodological development. We present OpenMidnight 1.1, an open-source replication and refinement of Midnight trained on approximately 12,000 publicly available whole-slide images from The Cancer Genome Atlas. Using an encoder initialized with pretrained DINOv2 weights, OpenMidnight 1.1 uses approximately 320 H100 GPU-hours for pathology pretraining, a 34-fold reduction relative to the compute reported for Midnight. Across 16 classification and four segmentation datasets in THUNDER, OpenMidnight 1.1 achieves the highest mean segmentation Dice (69.7) and ranks fourth among 14 models, ahead of Midnight, with performance that matches or exceeds models trained on substantially larger datasets in several tasks. Our ablation studies additionally examine how initialization, data volume, model size, and tissue composition affect downstream performance, providing empirical evidence to inform the development of future training recipes. Our release of the training code, preprocessing pipeline, and model weights lowers barriers to reproducible research and further development of competitive pathology foundation models.

0.50