CS Paper Radar

Retention-Constrained Post-Training Quantization of Cellpose-SAM for Stem Cell Microscopy

Sebastián A. Cruz Romero

cs.ET physics.med-phq-bio.QM ·submitted 2026-09-17 19:55 UTC · v1
publishedunusual

Abstract

Induced pluripotent stem cell (iPSC) culture increasingly relies on segmentation foundation models, yet deployment on laboratory CPUs and edge hardware requires compression schemes that are both efficient and auditable. We present a deployment-oriented evaluation of compressed Cellpose-SAM using a pre-specified retention criterion: the 95% cluster-bootstrap interval of mean change from FP32 must remain above a fixed -0.02 margin for every imaging modality. On a stratified 176-field panel spanning BBBC038 nuclei, BBBC039 U2OS fluorescence, and NIST iPSC images across density regimes, weight-only W8A16 preserves instance F1 across all modalities. A sensitivity-guided mixed W4/W8 scheme, using four INT8 exceptions, achieves a 6.76x reduction in weight storage with no observed catastrophic failures (0/176 fields), matching W8A16 at this sample size. In contrast, ternary weight-only quantization achieves 12.08x compression but fails catastrophically on 169/176 fields. These results demonstrate that compression should be evaluated by modality-stratified downstream retention rather than single-number accuracy, and establish a reproducible protocol for auditing compressed foundation models in regulated stem-cell imaging.

Comment
Peer-reviewed and accepted at NeurIPS 2026 LXAI Workshop. Pending presentation/publication at JLXAIR

Closest papers

Nearest neighbours by meaning across the whole index.

Reliability-Preserving Compression for Deployable Medical Image Segmentation

eess.IV cs.AIcs.CVcs.LG+1 ·2026-10-18 ·Sagar Kumar, Shailja Sharma, Tirthajit Baruah, Punit Rathore
similarity 0.56
Abstract

Post-training compression of pretrained medical segmentation models commonly uses quantization, pruning, or distillation to reduce model size and computational cost. Existing medical segmentation quantization studies mainly evaluate Dice, model size, memory, and latency, but this is incomplete for safety-critical use because compressed models should also preserve uncertainty signals that indicate unreliable predictions. We study this problem in compressed MRI/CT segmentation and formalize why Dice can remain stable while uncertainty changes. Motivated by this failure mode, we propose score-guided aggregate-validated mixed precision (SGAV-MP), a post-training compression framework that selects layer precisions under reliability constraints. SGAV-MP ranks quantization actions with a compact benefit-risk score and accepts them only after full-model reliability validation on a calibration set. Across five 2D backbones and three 3D benchmarks, SGAV-MP preserves FP32-level Dice and high uncertainty-map agreement, achieving $3.59\times$--$7.8\times$ compression in 2D and $4.73\times$--$7.82\times$ in 3D. We also report backend-supported TensorRT deployment measurements separately to distinguish runtime execution from reliability-preserving storage compression.

0.28

Unlocking Fine-Grained Cell Representations via Soft-Interior Rim Dense-Grid Pooling in Pathology Foundation Models

cs.CV ·2026-11-14 ·Wenwen Lou, Mingyi He, Xinyi Guo, Yining Li, Weiming Chen +4 more
similarity 0.55
Abstract

Fine-grained cell representations are essential for characterizing cellular heterogeneity and tissue organization in computational pathology. Pathology foundation models (PFMs) provide powerful pretrained features for transferable tissue analysis. HoVer-Net uses task-trained segmentation and typing, whereas CellViT++ averages native-grid tokens assigned to detected nuclei. However, the former requires cell-specific training; the latter ignores fractional nuclear coverage and can mix nuclear content with neighbouring tissue. Therefore, we propose SRDP, short for Soft-interior Rim Dense-grid Pooling, a training-free geometry-aware readout. We apply the frozen patch projection at half stride, interleave four offset lattices, map the cell mask to fractional coverage weights, and concatenate whole-cell pooling with two inner boundary pools. Across four datasets and six frozen encoders, SRDP improves mean balanced accuracy by 5.68 percentage points over native token averaging across 24 settings, including 11.22 points on average for CoNIC and Lizard. SRDP converts a coarse frozen PFM lattice into a mask-aligned, fine-grained cell representation without updating the encoder.

0.05

From Cross-Section to Cross-Omics: Conditional Cell Nucleus Image Editing in Spatial Transcriptomics

cs.AI ·2026-10-30 ·Yuechen Yang, Junchao Zhu, Junlin Guo, Yanfan Zhu, Ruining Deng +10 more
similarity 0.52
Abstract

Spatial transcriptomics (ST) platforms simultaneously measure gene expression and capture cell nucleus images at single-cell resolution. A fundamental property of tissue preparation introduces a confounding relationship between the two measurement modalities: sectioning a three-dimensional tissue into a thin slice produces a two-dimensional cross-section whose area depends on the cutting angle. Larger cross-sections expose more cytoplasm, yielding higher mRNA counts, while pathomics features such as nuclear area are measured directly from the same 2D boundary. This sectioning geometry creates an apparent correlation between gene expression and pathomics that reflects the measurement process rather than independent biology. Existing gene-to-image methods generate cell images from gene features but do not support condition-driven editing of existing images across both omics layers. We apply the Manifold-Aware Diffusion (MAD) framework to this dual-omics editing setting, enabling targeted modification of one feature group while preserving the other. Evaluated on podocyte cells from CosMx SMI kidney tissue, MAD achieves MAE=0.6636 and FID=25.19 for pathomics editing, outperforming all compared baselines. A controlled simulation study further confirms that the VAE component in MAD better preserves cross-group independence than CCDM (MAD without VAE).

0.28

GESTALT: Fast, Generalizable Histopathology Image Synthesis from Gene Expression with Pretrained Pathology Foundation Models

cs.CV ·2026-10-31 ·Felix Ho, Alexandros Graikos, Dimitris Samaras
publishedbenchmarkcode/data similarity 0.51
Abstract · Accepted at WACV 2027. 10 pages (8 main paper + 2 references), 4 figures. 8 pages of supplementary material

Spatial transcriptomics measures gene expression while preserving where each cell sits in the tissue. The inverse, what a given transcriptomic state looks like, is less explored but equally useful: it lets researchers visualize the morphological consequence of a molecular state and interpret a spatial assay's molecular calls against real tissue structure. GeneFlow, the current state of the art on the Xenium gene expression-to-image benchmark, trains a model from scratch, incurring a high cost on every new target dataset it is applied to. We instead propose GESTALT, which reformulates gene expression-to-image synthesis as predicting a pathology foundation model's image embedding. A lightweight gene-token transformer predicts this embedding from multi-cell gene expression, and a frozen or LoRA-adapted diffusion decoder (PixCell) renders it as an image. Because this visual knowledge is reused rather than relearned, GESTALT trains in a fraction of the time. In both multi-cell and single-cell settings, our method outperforms the SoTA on perceptual metrics across all three Xenium datasets. Beyond improved image quality, GESTALT natively synthesizes at 1024 x 1024, and is evaluated in three generalization settings: zero-shot transfer across gene panels and datasets, held-out patients and disease states, and transfer across studies and tissue sources. Coupled with a statistical model of spatial expression, GESTALT also provides, to our knowledge, the first paired synthesis of cell-resolved transcriptomic fields and tissue images with explicit control over cell type, density, and composition. Code is available at https://github.com/trongnhandev1011/Gestalt.

0.44

Quantization-Aware Healing: A Practical Recipe for Recovering Compressed, 4-Bit LLMs

cs.CL cs.AIcs.LGcs.PF ·2026-08-21 ·Bakbergen Ryskulov, Iker García-Ferrero, David Montero, David Jansen, Ali Hashemi +3 more
similarity 0.50
Abstract · Patent Application Number: 26382838.6 / P202602102EP

Serving large language models cheaply increasingly means shipping models that are both structurally compressed to a fraction of their parameters and quantized to 4 bits. Together these steps degrade reasoning, mathematics, coding, and long-context behavior enough to require a recovery, or healing, stage before deployment. The default recipe, quantization-aware training (QAT), re-fits the compressed, quantized model to hard labels; in our pipeline it converged slowly and collapsed past its peak. We adopted Quantization-Aware Healing (QAH) instead. Because a structurally compressed model is never independently trained at full precision, its bfloat16 checkpoint is a distillation-recovered approximation of the original; QAH distills the 4-bit student directly from the original, uncompressed model. On a GPT-OSS 120B to 60B to MXFP4 pipeline, the QAH student matches or beats its bfloat16 source on 7 of 9 benchmarks at roughly 4 times less weight memory and half the teacher's parameter count, and is released open-weight as Hypernova-60B. Against a matched QAT baseline it reaches a comparable peak about 7 times faster and stays stable under continued training, without hand-tuned early stopping. We also report deployment lessons, including a large, reproducible quality gap between distributed-training backends. Our aim is a recipe deployable without a multi-week hyper-parameter search.

0.14

MedSegBenchmarker: A Raw-Count-First Framework for Controlled 2D Medical Image Segmentation Benchmarks

cs.CV cs.AI ·2026-08-30 ·Vanessa Borst, Lukas Horn, Daniel Grillmeyer, Thomas Prantl, Samuel Kounev
benchmark similarity 0.50
Abstract · 10 pages, 4 figures;

Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

0.45

EntroPack: Fast and Accurate Entropy-Coded Weight Compression at Arbitrary Bitrates

cs.LG cs.AI ·2026-09-28 ·Hong Zhang, Zhongjie Duan, Yingda Chen
code/data similarity 0.50
Abstract

Weight compression helps large neural networks fit deployment memory budgets, but common fixed-width formats offer only coarse storage choices. Entropy coding supports finer rates, yet the achieved size depends on the quantized weight distribution and coding overhead. Exploiting this flexibility requires accurate rate selection and efficient weight reconstruction for inference. We present EntroPack, an entropy-coded weight compressor that supports arbitrary target bitrates without activation calibration or fine-tuning. It combines row-normalized $E_8$ lattice quantization with a conditional probability model of lattice coordinates. Sampled storage estimates select the quantization resolution without repeated full-stream encoding. The final coordinates are entropy-coded in independently decodable tiles, enabling fast, fused symbol decoding and numerical weight reconstruction on the GPU. EntroPack supports floating-point and integer weight containers, such as BF16, FP16, FP8, and INT8, with storage bitrate controlled independently of numerical precision. Online decoding adds latency that grows with weight count, making the method well suited to compute-intensive workloads such as diffusion denoising and Transformer prefill. Experiments demonstrate fast encoding and modest inference overhead in these settings. When compressing the linear-layer weights of the image generator Z-Image-Turbo, EntroPack achieves substantially lower weight and denoiser output errors than fixed-width formats at comparable storage rates, with modest denoising-step overhead. Targeting 4 bits per parameter, it achieves lower weight and denoiser output errors than NF4, including about 24% lower relative $L_2$ weight error, with less storage. Source code is available at https://github.com/modelscope/entropack.

0.35

BigCell: Generating Gigapixel Whole-Slide Images

cs.CV cs.LG ·2026-10-09 ·Srikar Yellapragada, Alexandros Graikos, Zilinghan Li, Kostas Triaridis, Tarak Nath Nandi +8 more
top venuecode/data similarity 0.50
Abstract · Accepted at NeurIPS 2026. Project page: https://histodiffusion.github.io/docs/projects/bigcell/

Whole-slide images (WSIs) are gigapixel-scale digital scans of histopathology tissue and serve as the primary basis for cancer diagnosis. Existing histopathology generative models operate at the patch scale, producing fixed-size tiles of at most 1024$\times$1024 pixels which encompass only a small fraction of the WSI. In contrast, text reports for clinical diagnoses and slide-level diagnostic labels -- the supervision that exists at scale -- operate at the whole-slide level. We present BigCell, the first approach to generate coherent whole-slide histopathology images at native gigapixel resolution. BigCell trains a flow-matching transformer at 2048$\times$2048 pixels on over 120,000 publicly available WSIs spanning multiple organ types. Conditioning on embeddings from pathology foundation models and using an inference-time sliding-window pipeline, BigCell generates coherent images of up to 32,768$\times$32,768 pixels, outperforming prior tile generators on both tile-level and slide-level fidelity metrics. To make gigapixel synthesis practical, we introduce an adaptive scheduling strategy that prioritizes important slide regions, speeding up image generation by over 3\ttimes with minimal quality degradation. Furthermore, we propose the first text-to-image synthesis at 8k resolution by training a separate model that produces dense conditioning grids directly from pathology text reports. We demonstrate that augmenting with synthetic samples improves slide-level few-shot classification performance by up to $18 \%$ over baselines trained on real data.

0.45