CS Paper Radar

WebMRIQC: A Web-Based Implementation of MRIQC for Accessible MRI Image Quality Assessment in Resource-Constrained Settings

Philip Nkwam, Ifeoluwa Oladeji, Sekinat Zurakat-Aderibigbe, Jasmine Cakmak, Harrison Aduluwa, Confidence Raymond, Cliff Mokua, Abdulrazaq Zubair, Daniel Champanda, Tolulope Olusuyi, Maruf Adewole, Udunna Anazodo

cs.CV ·submitted 2026-09-21 02:28 UTC · v1
publishedcode/dataunusual

Abstract

Reliable quality control (QC) of magnetic resonance imaging (MRI) is essential for reliable diagnostic neuroimaging, yet standard manual assessment is subjective and time-consuming. MRIQC has established standardized automated extraction of image-quality metrics (IQMs), but its reliance on local computational imaging skills and capacity including high-performance computing, limits its adoption in resource-constrained settings (RCS). We present WebMRIQC (webmriqc.mailab.io), an open-source browser-based platform that wraps the validated MRIQC engine behind a zero-installation web interface. WebMRIQC automates the DICOM-to-BIDS conversion of de-identified MRI scans, executes the unmodified containerized MRIQC pipeline on a shared compute node governed by a fair-share job queue, and returns an interactive in-browser dashboard. The dashboard grounds every IQM in published quality thresholds, benchmarks each scan against the normative distribution of high-resource open datasets, and supports cross-site multicentre implementation of optimized scan protocols in RCS.We describe the system architecture and a validation framework establishing measurement equivalence between WebMRIQC and native MRIQC across thirteen IQMs on the BraTS-Africa and BraTS 2021 datasets. Preliminary results indicate strong agreement for contrast-, signal and noise-based metrics, demonstrating that web-based implementation lowers the barrier to standardized MRI QC and provides a foundation for harmonized, regionally adapted quality benchmarks across RCS imaging sites. The code is publicly available here https://github.com/CAMERA-MRI/WebMRIqc.

Comment
MICCAI CONFERENCE- MIRASOL 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Unifying Image Quality Assessment Datasets: MOSAIQ-500K and MOSAIQ-Bench

eess.IV ·2026-09-17 ·Wenbo Yang, Zhongling Wang, Jialu Xu, Jinghan Zhou, Zhou Wang
benchmark similarity 0.54
Abstract · 6 pages, 5 figures. This work has been submitted to the IEEE for possible publication

Image quality assessment (IQA) datasets use different subjective protocols and rating scales, so their scores are not directly comparable. The lack of a common perceptual scale hinders multi-dataset training and precludes direct inter-dataset evaluation. We address this by conducting a new subjective experiment and using its ratings as perceptual anchors to fit monotonic mappings that place the existing scores of 23 IQA datasets on a common quality scale while preserving within-dataset rankings. The resulting dataset, MOSAIQ-500K, contains over 500,000 images and is, to our knowledge, the largest IQA dataset with perceptually aligned subjective scores. We also propose MOSAIQ-Bench, an inter-dataset benchmark, and use it to evaluate 31 IQA methods, revealing substantial gaps between intra- and inter-dataset performance, particularly on authentic distortions. The aligned scores offer a key advantage: replacing specialized multi-dataset training mechanisms with standard regression losses yields comparable intra-dataset accuracy and better inter-dataset performance. MOSAIQ thus provides a practical foundation for combining heterogeneous IQA datasets to train more generalizable IQA models. Code and dataset will be made public at ivc.uwaterloo.ca/projects/unifying_iqa_datasets/ upon acceptance.

0.26

ImageRSI: Verification-Driven Recursive Self-Improvement for Agentic Image Generation

cs.CV cs.AI ·2026-10-23 ·Shuo Han, Zhilin Wang, Peng Ling, Wenjia Gong, Yang Liu +3 more
benchmark similarity 0.54
Abstract

Complex text-to-image requests remain difficult to satisfy reliably. Verifying and repairing an image can fix an individual output, but a successful repair does not necessarily carry over to other requests. We present ImageRSI, a framework that keeps the image generator frozen and combines three components: five-dimensional verification and repair within each task, an experience library shared across tasks, and offline updating of the judge. Candidate experiences enter the library only after paired A/B validation, and the judge is updated with supervised fine-tuning and GRPO on accumulated image-judgment records and evaluated before reuse. We also introduce ImageReq-Bench, a benchmark of 961 requests built around hard cases in real-world image-generation requests, each paired with an evaluation checklist. ImageRSI achieves a Checklist Strict Accuracy (CSA) of 52.6% on MindBench (with Nano Banana Pro as the generator) and 65.66% on ImageReq-Bench, and we compare system outcomes across judge-training configurations.

0.35

MRFoundry: Knowledge-guided agent loops for end-to-end MRI research

eess.IV cs.AI ·2026-11-09 ·Ke Wang, Atakan Topcu, Hossein Momeni, Molin Zhang
code/data similarity 0.53
Abstract · 18 pages, including 6 pages of Supporting Information. Code: https://github.com/KeWang0622/MRFoundry

AI agents can write code, use scientific software, and revise computational workflows, opening new possibilities for MRI research. Effective assistance requires connecting acquisition physics, data conventions, specialized tools, and scientific validation. We present MRFoundry, an open-source, extensible package that connects MRI knowledge to agent actions and output checks. Project-local memory preserves decisions and evidence, while reviewed contributions allow researchers to improve shared guidance. Researcher-supervised examples demonstrate skill-guided sequence auditing and acquired-data reconstruction, connecting tool use, output checks, and documented decisions. Alongside MRFoundry, we introduce MRI Agent Bench to compare agents with and without the package across models and MRI task domains. Across 240 paired Core evaluations spanning 24 task types and ten models, all-checks-passed completion increased from 67.5% without MRFoundry to 78.3% with it. Across 134 Hard pairs, completion increased from 36.6% to 44.8%. MRFoundry makes MRI workflow expertise available as reusable guidance that researchers can inspect, adapt, and extend within existing agent and scientific software environments. MRFoundry is openly available at https://github.com/KeWang0622/MRFoundry.

0.41

QICOM: Open-Source Software for Reproducible Image Quality Evaluation, Blinded Assessment, and Radiomic Comparison

eess.IV cs.AI ·2026-10-22 ·Fabio Mattiussi, Switinder Ghotra
code/data similarity 0.53
Abstract

QICOM (Quality Image COMparator) is open-source software for quantitative image comparison, paired radiomics, and blinded assessment. It saves processing settings, image identities, measurements, and response mappings so a comparison can be reopened and recalculated. We evaluate reference agreement, responses to controlled perturbations, and recovery of saved analyses. Synthetic experiments cover 37 quantitative descriptors using independentnumerical references and separate upstream integration comparisons. The QICOM/MIRP backend meets the reference tolerances for all 482 numeric IBSI 1 digital-phantom entries and all 1,622 entries across configurations A-E of the public CT reference case; these comprise 1,804 feature/aggregation comparisons and 300 preprocessing diagnostics. Restricting masked SSIM and HFEN to complete kernel support removes the observed dependence on excluded pixels. In a synthetic filtering example, stronger smoothing increases SSIM while worsening MSE and HFEN relative to milder smoothing and changing GLCM contrast more strongly. Reopened radiomics projects reproduce all 43 feature pairs per comparison, and two blinded deliveries return four correctly mapped scripted responses. These experiments document the calculations and data transfers linking the three workflows.

0.30

MedPAO-Assist: Edge-Deployable, Modality-Aware Agentic AI for Radiology Report Structuring

cs.AI ·2026-10-17 ·Shrish Shrinath Vaidya, Minmini Selvam, Ganapathy Krishnamurthi
published similarity 0.53
Abstract · The paper has been accepted at MICCAI Workshop Agentic AI for Medicine, 2026

The adoption of Large Language Models for radiology report structuring has been largely dominated by either proprietary cloud-based models or large open models requiring high-end GPUs for deployment, which is a critical bottleneck for clinical adoption in radiology workflows that demand data privacy and offline operation. To address this, we present MedPAO-Assist, an edge-deployable agentic framework that generates structured radiology reports directly from radiologist dictation and voice commands, requiring only $\approx3.3$ GB peak RAM and achieving an average end-to-end latency of $\approx31$ seconds on a standard laptop CPU through an asynchronous, multi-threaded execution pipeline. The system currently supports four major imaging modalities -- Chest X-ray, Chest CT, Abdomen CT, and Brain MRI. To our knowledge, it is among the earliest agentic systems to run its entire pipeline with a Small Language Model (SLM) in the 0.6B-parameter range. This multi-agent architecture, built around an Extract-Ground-Generate paradigm, performs concept extraction, SNOMED-CT grounding, and structured report generation, followed by a speech-driven human-in-the-loop correction phase, together forming a fully "no-touch" reporting workflow that requires no keyboard input, external API calls, or internet connectivity. We evaluate each pipeline stage individually -- concept extraction, ontology grounding, and concept categorization and report hardware profiling results demonstrating the system's feasibility for real-time, CPU-only clinical deployment.

0.24

OpenBrain: An Auditable Generated-Label Release for Whole-Brain MRI Parcellation

cs.CV ·2026-11-03 ·Qizhen Lan, Yu-Chun Hsu, Yuxiang Wei, Lijing Zhu, Zenan Sun +3 more
top venuecode/data similarity 0.52
Abstract · Accepted at NeurIPS 2026, Evaluations and Datasets Track. Dataset: https://huggingface.co/datasets/lanqz7766/OpenBrain; code: https://github…

Automatic tools can now generate whole-brain MRI parcellations at cohort scale, but generated-label releases often provide little evidence about which cases are reliable enough to reuse. We introduce OpenBrain, a confidence-aware release of 35,838 provenance-verified OpenNeuro T1w cases from 607 source datasets. OpenBrain is organized as an auditable case-record release rather than a directory of standalone segmentation files: each record links a primary parcellation, two committee parcellations, source/license provenance, raw QC-7 measurements, percentile risks, a combined risk score R, and a confidence tier. QC-7 is a reference-free reliability panel over label geometry, image-label consistency, and committee disagreement, so users can filter, weight, audit, or re-threshold generated labels without rerunning inference. We evaluate this released evidence under a frozen protocol. Across external cohorts, lower QC-7 risk corresponds to higher generated-label quality; in fixed-budget training, lower-risk selections improve paired macro Dice over random selection by +3.2 to +3.7 percentage points. OpenBrain also exposes raw axes, committee outputs, provenance, and datasheet documentation, so confidence claims remain inspectable after download. It does not turn generated labels into manual annotations or clinical-grade segmentations. Its contribution is a large open generated-parcellation substrate, a reusable case-level risk-evidence layer, and an external validation protocol for release-time QC. Dataset: https://huggingface.co/datasets/lanqz7766/OpenBrain. Code: https://github.com/lanqz7766/openbrain.

0.44

GaborFlow: Hardware-Software Co-Optimization of Gabor Filter Accelerator Design

cs.AR ·2026-10-10 ·Priyanka Agarwal, Pruthvi Parate, Raghav Khurana, Madhav Rao
similarity 0.51
Abstract · 8 pages, 3 figures, 6 tables

Brain tumor classification from MRI scans represents a critical challenge in medical imaging, where accuracy directly impacts patient outcomes. This paper introduces GaborFlow, a novel hardware-software co-optimization framework that revolutionizes the design of the Gabor Filter accelerator for generating feature maps to enhance brain tumor detection. Unlike conventional approaches that rely on fixed filter parameters, our method employs trainable Gabor coefficients within a carefully optimized range, integrated with an EfficientNet-B0 backbone CNN architecture. The innovation lies in the synergistic combination of software optimization through Bayesian hyperparameter tuning and hardware efficiency through precision-optimized multipliers. Our GF baseline accelerator achieves remarkable results, with 98.6% classification accuracy, 28.08% power benefits, and 48.83% footprint savings compared to state-of-the-art implementations, demonstrating that medical AI can be both highly accurate and energy-efficient. The hardware design files are made freely available for easy adoption and further usage by the researchers and designers.

0.32

SmartBloch-Agent: An Agentic Framework for Automated MRI Sequence Design and Optimization

cs.AI physics.med-pheess.IV ·2026-11-06 ·Jiakai Yang, Haoye Zheng, Yixiao Yue, Qinqin Yang, Zhong Chen +2 more
similarity 0.51
Abstract

Magnetic resonance imaging (MRI) pulse sequences organize radiofrequency excitation, gradient encoding, and signal acquisition, determining magnetization evolution and image formation. Sequence research requires translating imaging objectives into executable protocols meeting physical and acquisition constraints, refined via physical simulation, signal reconstruction, and scientific evaluation. Sequence construction, physical verification, parameter search, and assessment involve many tools and manual decisions, limiting automation from objective to verifiable sequence. We develop SmartBloch-Agent, an integrated framework for automated MRI sequence design and optimization. Given objectives and scientific constraints in natural language, an AI agent interprets goals, plans tasks, orchestrates tools, and makes feedback-informed decisions, drawing on a construction module and optimizers for structural design and parameter search. Our GPU-accelerated SmartBloch engine supplies physical computation for both stages, so the framework configures, per sequence and objective, event validation, Full-Bloch magnetization evolution, signal acquisition, image reconstruction, and scientific evaluation, and closes the loop without external MRI simulators. Results return to the agent to guide sequence revision, parameter optimization, and candidate selection, and the design files carry simulation, reconstruction, and evaluation evidence, forming an output package for a real-scanner workflow. Experiments show the framework automatically designs and optimizes MRI sequences for varied objectives and constraints, refines candidates with physical feedback, and improves several parameter-estimation metrics and downstream quantitative reconstruction. SmartBloch-Agent unifies objectives, design, physical execution, and evaluation into a continuous workflow for end-to-end automation of MRI sequence research.

0.22