CS Paper Radar

SGAM: Shared Gaussian Geometry with Implicit Amplitude Modeling for Scan-Specific 3D Multi-Contrast MRI Reconstruction

Jingran Xu, Dong Liang, Hairong Zheng, Yuanyuan Liu, Yanjie Zhu

cs.CV ·submitted 2026-09-21 12:10 UTC · v2

Abstract

Three-dimensional (3D) multi-contrast magnetic resonance imaging (MCMRI) provides rich anatomical and quantitative information but requires long acquisition times, motivating k-space undersampling. However, reconstruction of large volumetric datasets imposes substantial computational and memory demands. To address this challenge, we propose SGAM, a memory-efficient, scan-specific framework for joint full-volume 3D MCMRI reconstruction. SGAM is based on a shared-geometry Gaussian representation in which amplitudes are modeled by a multi-output implicit neural representation (INR) and contrast-specific phases by explicit variables. This design exploits common anatomical structure across contrasts while preserving contrast-specific signal variations. The representation is jointly optimized using only the acquired multi-coil k-space without external training data. Experiments showed that SGAM consistently outperformed the comparison methods across imaging tasks and acceleration factors, with greater improvements under stronger undersampling. SGAM also achieved a favorable balance between reconstruction quality and computational cost, demonstrating its effectiveness for 3D multi-contrast MRI reconstruction.

Closest papers

Nearest neighbours by meaning across the whole index.

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

cs.CV ·2026-10-17 ·Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus +6 more
similarity 0.73
Abstract · 26 pages, 6 figures, 15 tables (including appendix)

Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorten acquisitions by sacrificing spatial resolution, particularly along the slice axis. Super-resolution can recover higher-resolution images, but existing methods are typically specialised to one scale or acquisition geometry, limiting their use across heterogeneous clinical protocols. We present GSMR3D, a continuous volumetric model that reconstructs arbitrary isotropic and anisotropic resolutions with a single checkpoint per MRI contrast. It combines a learned dictionary of anisotropic 3D Gaussian prototypes with scale-conditioned frequency encoding and an exact measurement-consistency projection, keeping reconstructions consistent with the acquired low-resolution data. We train separate models on 3,731 contrast-enhanced T1-weighted and 30,254 T1-weighted brain MRI volumes from clinical and population-based cohorts. We evaluate GSMR3D against geometry-specific specialists for isotropic, in-plane, and through-plane super-resolution using reconstruction quality and downstream tasks: brain tumour segmentation, brain-metastasis detection, and brain parcellation. GSMR3D outperforms specialists at isotropic $2\times$ and achieves better LPIPS, DISTS, and FID across all geometries, although specialists retain higher PSNR in anisotropic settings. It more faithfully preserves glioma segmentations across all geometries, achieves the highest lesion sensitivity on an independent brain-metastasis cohort, and the highest brain-parcellation agreement for isotropic and in-plane reconstruction. Reconstruction takes about 6s per volume, adding little overhead relative to acquisition-time savings. GSMR3D offers a flexible approach to MRI scan-time reduction with one model per contrast across geometries while preserving information relevant to downstream tasks.

0.17

Diffusion-Encoding Gaussian Field for Joint k-q dMRI Reconstruction

cs.CV ·2026-09-02 ·Zhibo Chen, Yajuan Huang, Yu Guan, Qiuyun Fan, Dong Liang +1 more
similarity 0.71
Abstract · 11 pages, 8 figures. Preprint submitted to IEEE Journal of Biomedical and Health Informatics

Diffusion MRI requires repeated k-space acquisitions over multiple diffusion-encoding directions, making acquisition time dependent on both spatial and angular sampling. Existing joint k-q methods either associate directional parameters with fixed voxels or separate spatial reconstruction from angular completion. However, diffusion-weighted images acquired under different directions share the same anatomical organization, while their local signal intensities vary with diffusion encoding. Existing formulations do not fully exploit the complementarity between shared anatomy and direction-dependent signal variation. Consequently, residual spatial errors may be misinterpreted as genuine angular variation and propagated to unobserved directions. We propose a subject-specific spatial-angular Gaussian field for self-supervised joint k-q dMRI reconstruction. Shared 3D Gaussian primitives provide local spatial support, with each primitive carrying a continuous q-conditioned tensor-residual response. The signal at each location is synthesized from multiple overlapping primitive responses, coupling neighboring spatial regions and diffusion directions. The field is progressively optimized from undersampled k-space measurements of observed directions, without fully sampled targets or held-out-direction supervision. Experiments on three HCP diffusion shells under multiple acceleration settings demonstrated consistent improvements in missing-direction DWI reconstruction, tensor-derived metrics, and principal diffusion orientation estimation.

0.26

Learning Subject-Specific Anatomical Representations via Manifold Expansion: Application to Accelerated Multi-Contrast MRI

cs.CV cs.IR ·2026-10-02 ·Ruimin Feng, Wanyu Bian, Albert Jang, Zachary Stewart, Fang Liu
similarity 0.70
Abstract

Clinical MRI routinely acquires multiple contrast-weighted images of the same anatomy for complementary tissue characterization. However, current accelerated MRI methods typically reconstruct each contrast independently, without fully exploiting shared anatomical information. This work aims to learn anatomical representations invariant to contrast-dependent appearance for reconstruction of accelerated multi-contrast MRI. We propose MAX (MAnifold eXpansion), a subject-specific framework that learns anatomical representations from a single fully sampled reference contrast. To address the under-constrained separation of shared anatomy and contrast-dependent components from a single image, MAX expands the multi-contrast manifold using anatomy-preserving intensity augmentations. A disentangled implicit neural representation models augmented samples using shared spatial coordinates for anatomy and spatially invariant coordinates for contrast appearance. The learned anatomical representation is then fixed, with the contrast representation adapted to the undersampled target data, followed by unrolled refinement. Theoretical analyses further provide insight into the disentangled representation learning and explain how the learned anatomical representation improves the target contrast reconstruction. At R = 8 for brain MRI and R = 6 for knee MRI, MAX achieves the highest mean PSNR and SSIM across all tasks, improving PSNR by more than 1 dB over the strongest baseline for both brain contrasts. MAX more faithfully recovers subtle anatomical and pathological structures and remains robust to inter-contrast motion, structural heterogeneity between reference and target contrasts, and measurement noise. Therefore, MAX provides a general strategy for leveraging high-quality reference scans in accelerated MRI and has the potential to be extended to other reference-assisted MRI inverse problems.

0.12

MedGSSR: Generalizable Medical Image Super-Resolution 3D Reconstruction via Hierarchical Feed-forward Gaussian Splatting

eess.IV cs.CEcs.CVq-bio.QM ·2026-09-06 ·Chengkai Wang, Luoyu Hong, Yiting Zhao, Jiamin Wang, Xiang Feng +5 more
top venue similarity 0.69
Abstract · ECCV 2026

High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr

0.47

Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators

eess.IV cs.CV ·2026-11-11 ·Jiayun Wang, Ram Daftari, Weijie Gan, Valentin Duruisseaux, Ruibo Wang +3 more
published similarity 0.68
Abstract · NeurIPS 2026

Deep-learning-based 3D MRI reconstruction is limited in practice by the GPU memory and compute cost of full-volume training; 3D acquisitions are thus most often reconstructed by 2D models applied slice-by-slice and then stacked, which ignores through-plane (stacking-axis) structure. We reconstruct in full 3D and ask whether a model can be trained at low resolution (fast and memory-feasible) yet deployed at higher resolution. This coarse-to-fine strategy needs reliable cross-resolution performance, but standard networks are resolution-specific and degrade substantially when evaluated outside the training setting. We therefore use resolution-agnostic neural operators (NOs) and propose KIR-NO (k-space-to-Image Reconstruction Neural Operator), a discretization-agnostic framework for accelerated 3D MRI reconstruction. KIR-NO is trained with full backpropagation on low-resolution volumes and applied zero-shot to higher-resolution volumes at inference. Its core building block is a 3D neural operator based on discrete-continuous convolutions: convolutional filters are parameterized in a continuous basis and sampled at arbitrary voxel resolutions while preserving the local inductive bias of convolution. KIR-NO integrates these learned operators with physics-based consistency: a k-space neural-operator head first refines the undersampled Fourier measurements, and image-space neural-operator cascades then refine the reconstruction through interleaved data-consistency updates. Across 3D knee and brain MRI benchmarks, KIR-NO improves over classical and CNN baselines: it improves over a state-of-the-art 3D CNN by 2.2 dB PSNR at half resolution under 4x acceleration on SKM-TEA, with gains persisting at 8x and 16x. These results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction - cheap low-resolution training with high-resolution deployment - practical across anatomies.

0.27

Mr3D-VL: A generalist vision language foundation model for Multiparametric 3D Magnetic Resonance Imaging

cs.CV cs.AI ·2026-08-13 ·Zhi Qiao, Xintong Wu, Yichu He, Feng Shi
similarity 0.67
Abstract

Multi-parametric magnetic resonance imaging (mpMRI) is a cornerstone for brain tumor diagnosis and treatment, yet current AI models face critical limitations: their lack of natural language interaction and interpretability impedes spatial information integration and cross-modal reasoning required clinically. Key challenges arise from significant physical meaning differences across modalities, spatial misalignment due to scan intervals, and the need for complex multi-feature interpretation in tasks like glioma grading. While visual-language models (VLMs) show promise in cross-modal understanding, existing methods focus mainly on 2D image modeling, neglecting direct perception of 3D volumetric space. Although 3D VLMs have been proposed for report generation and feature alignment in 3D CT imaging, mpMRI applications demand collaborative inference across multiple imaging modalities-a requirement unmet by current solutions. To address this, we introduce Mr3D-VL, a dedicated visual-language foundation model for multi-parametric 3D MRI. With 4 billion parameters, it employs an unsupervised pre-trained shared 3D encoder and 4D rotational positional embedding for dual modality-spatial integration. Its cross-modal projection layer uses a multi-resolution feature implantation strategy to enhance feature perception across resolutions. Experimental results show significant improvements over existing 4B/7B/30B domain-specific and general-purpose models in text generation tasks, achieving a BERTScore of 0.856 for report generation, with question-answering accuracy at 0.713 and multiple-choice accuracy at 0.912.

0.04

Unified Multi-plane Autoregressive Diffusion for 3D Multi-contrast MRI Synthesis

cs.CV ·2026-10-07 ·Yejee Shin, Geonhui Son, Jinglu Wang, Minwoo Jung, Yan Lu +1 more
top venue similarity 0.67
Abstract · Accepted to ECCV 2026

Acquiring a complete set of magnetic resonance imaging (MRI) contrasts is time-intensive and uncomfortable for patients, despite the diagnostic value of multi-contrast imaging. This motivates synthesizing missing contrasts from those already acquired, which is an inherently 3D problem requiring anatomical coherence across axial, sagittal, and coronal planes. However, fully 3D generative models are often impracti- cal under computational resources that scale cubically with volume size. We propose a unified Multi-Plane Autoregressive Diffusion (MPAD), a latent diffusion framework that achieves full-volume 3D synthesis using efficient plane-wise 2D operations while preserving volumetric coherence. A 3D autoencoder first compresses MRI scans into an isotropic 3D la- tent representation. A 2D diffusion model is then trained to reconstruct masked latent slices of the target contrast, conditioned on both source- contrast slices and unmasked target-contrast slices. During inference, we introduce plane-wise autoregressive synthesis with inter-plane priors. Slices are generated autoregressively in random order within one plane orientation to maintain intra-plane continuity, then propagated as con- ditioning priors to orthogonal plane orientations to enforce inter-plane consistency. Compared to 3D latent diffusion baselines, MPAD reduces training and inference FLOPs by 7x and 3x, respectively, while also lowering inference time and peak memory consumption. Experiments on multiple datasets demonstrate that MPAD achieves superior perfor- mance, generating high-fidelity 3D volumes and supporting one-to-many translation within a single unified model.

0.33

Reduce, Then Encode: Multiscale Volumetric Reduction for 2D Foundation Models in Brain MRI

cs.CV ·2026-09-28 ·Dexuan Ding, Yuankai Qi, Bogong Wang, Luping Zhou, Amin Beheshti
similarity 0.66
Abstract

Pretrained 2D foundation models offer a practical alternative to dedicated 3D pretraining for brain structural magnetic resonance imaging (sMRI), but their use on volumetric data requires bridging the mismatch between a 2D encoder and a 3D volume input. Existing methods typically encode slices independently and integrate their features afterwards. We introduce Multiscale Volumetric Reduction (MVR), a reduce-then-encode approach that compresses each anatomical view from (D) slices into (M << D) complementary 2D components before foundation-model encoding. MVR combines an uncentered-PCA base component derived from the original through-plane intensities with residual detail components constructed from multiscale spatial descriptors. The reduction is estimated from the training volumes without diagnostic labels or gradient-based optimization and remains fixed thereafter. The resulting components are independently processed by a shared frozen 2D foundation model and concatenated for linear probing. Under this frozen-encoder setting, MVR achieves strong overall performance across ADNI, OASIS, and ABIDE relative to the evaluated 2D-to-3D adaptation methods and simple input-reduction baselines, while also generalizing strongly from ADNI to AIBL.

0.13