CS Paper Radar

How Early Can You Tell? Early Eye Gaze Dynamics and Cybersickness Progression in Virtual Reality

Nevzat Umut Demirseren, Isayas Berhe Adhanom

cs.HC ·submitted 2026-09-21 21:19 UTC · v1

Abstract

Cybersickness remains one of the primary barriers to prolonged and comfortable virtual reality (VR) use, yet the temporal development of cybersickness remains poorly understood because its onset and progression vary substantially across individuals. Eye tracking provides a continuous and unobtrusive measure of user behavior, making it well suited for investigating how users respond throughout VR exposure. However, existing work has mainly focused on aggregate gaze measures or post-exposure assessments, leaving the relationship between early eye-movement dynamics and discomfort progression underexplored. In this paper, we investigate whether early eye-movement dynamics characterize the subsequent progression of cybersickness. Using trajectories of fixation duration, fixation dispersion, saccade amplitude, saccade velocity, and gaze eccentricity computed over the first one to five minutes of VR exposure, we evaluate their association with subsequent discomfort progression and compare early gaze dynamics between participants with low and high post-exposure cybersickness severity. Our results show that early fixation dispersion is consistently associated with subsequent discomfort progression, whereas no significant differences are observed between cybersickness severity groups. These findings suggest that early fixation dispersion can characterize the progression of discomfort rather than the final cybersickness severity. Overall, this work provides new insight into the temporal relationship between early eye-movement behavior and cybersickness progression, contributing to the understanding of gaze dynamics during immersive experiences.

Comment
6 pages, 3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Gaze Under Strain: How Oculomotor Behavior Tracks Cybersickness Progression in VR

cs.HC ·2026-10-23 ·Nevzat Umut Demirseren, Mehedi Hasan Raju, Oleg Komogortsev, Isayas Berhe Adhanom
published similarity 0.85
Abstract · Accepted for publication at ACM VRST 2026. 10 pages, 4 figures

Cybersickness remains a major barrier to comfortable, accessible virtual reality (VR). Arising from mismatches between visual and vestibular signals, it places sustained demands on gaze stabilization and visual processing. Because gaze is the mechanism through which users actively sample the virtual environment, cybersickness-induced disruptions may alter both what users perceive and how discomfort itself emerges. Yet, how eye-movement behavior evolves alongside discomfort during prolonged VR exposure remains poorly understood. We present a behavioral analysis of eye-tracking data from 19 participants navigating a realistic virtual environment over a 20-minute session, with discomfort rated repeatedly throughout the experiment. Linear mixed-effects models examined gaze constructs spanning fixation stability, visual exploration, and gaze allocation as functions of discomfort, exposure duration, and their interaction. Our results show that fixation stability degraded progressively with increasing discomfort, with the effect strengthening over time. Visual exploration showed no marginal discomfort effect but exhibited significant discomfort-by-time interactions, indicating that saccadic behavior adapts dynamically rather than responding uniformly to discomfort. Gaze allocation was not associated with discomfort but shifted systematically with time. These findings show that cybersickness does not uniformly disrupt gaze. Instead, different aspects of eye-movement behavior respond differently and change in ways that only become visible when discomfort is tracked repeatedly over time. Understanding how gaze evolves during cybersickness progression provides the behavioral grounding needed to better interpret how discomfort shapes the user's visual experience of immersive environments and to design more sensitive detection approaches.

0.32

Slide to Report: Continuous Reporting Symptom-Specific Cybersickness in VR

cs.HC ·2026-11-05 ·Purnata Saha, Rifatul Islam, Qiliang He, John Quarles
similarity 0.66
Abstract

Cybersickness is often assessed during VR exposure through discrete overall sickness, which cannot capture specific symptoms or their changes over time. Post-exposure questionnaires such as the Simulator Sickness Questionnaire provide symptom-specific measures but cannot be collected during immersion. We investigate whether separating cybersickness into three symptom-specific dimensions -- nausea, oculomotor discomfort, and disorientation -- during immersion provides more informative continuous measurements. We conducted a between-subjects study with 52 participants in a VR-rollercoaster, comparing a three-slider interface with a single-slider interface. Concurrently, participants also completed an auditory Simon task to measure attention. We additionally collected multimodal set of physiological signals, including GSR, ECG, PPG, eye and head tracking. Results show that each slider correlated most strongly with its corresponding SSQ subscale, whereas the single slider correlated with all SSQ subscales. Using three sliders did not significantly affect usability, workload, or attention. We publicly release the multimodal dataset to support future cybersickness research.

0.20

Unpacking the process of watching a 360-degree video: How physiological responses and head rotation relate to affective and cognitive outcomes

cs.HC ·2026-10-30 ·Portia Wang, Yujie Tao, Monique Santoso, Jeremy Bailenson
similarity 0.65
Abstract

A defining feature of 360-degree video is that the perceptual experience is actively constructed. As viewers turn their heads, shift their gaze, and encounter changing visuals, their perceptual experience is not predetermined, but rather emerges through ongoing exploration. Yet, it is unclear how the process of watching immersive videos unfolds, and how it is related to psychological and physiological outcomes. We present a large-scale study (N=200) in which participants experienced one of 10 pieces of 360-degree videos in virtual reality. Results showed that greater head rotation was associated with greater valence, higher attention focus, longer length of subjective review, and lower simulator sickness; greater pupil dilation was associated with lower valence, lower review ratings, and greater use of negative tone in written reviews. A mediation analysis revealed that participants who rotated their heads more experienced greater frame-to-frame pixel-level perceptual changes in their field of view, which in turn resulted in greater valence and lower simulator sickness. Moreover, participants tended to rotate their heads toward field of view regions with greater perceptual movement, while directing their eye gaze toward less perceptually dynamic areas within that view. We outline theoretical and practical contributions for designing 360-degree content and predicting experiential outcomes.

0.14

Beyond the Lab: Large-Scale Remote Cybersickness Research in Virtual Reality Using the VERA Platform

cs.HC ·2026-09-04 ·Matt Gottsacker, Gerd Bruder, Daniel Zielasko, Alexander Giovannelli, Ali Haskins +11 more
similarity 0.65
Abstract · This is a preprint of a publication currently under review at IEEE Transactions on Visualization and Computer Graphics (TVCG)

Cybersickness remains a major barrier for the adoption of virtual reality (VR), yet most existing knowledge is derived from laboratory-based studies with relatively small and homogeneous participant samples. In this paper, we investigate whether remote VR studies can produce cybersickness findings comparable to traditional in-lab experiments while enabling larger and more diverse participant populations. Using the Virtual Experience Research Accelerator (VERA), we deployed a remote adaptation of the standardized Cybersicker testbed for cybersickness research and collected data from N=263 participants using their own consumer VR headsets. We compared these results against a previously published in-lab dataset and a demographically matched subset of the remote sample. Across cohorts, cybersickness outcomes were consistent in direction and temporal pattern, including symptom onset trajectories, Fast Motion Sickness Scale (FMS) ratings, and Simulator Sickness Questionnaire (SSQ) responses, supporting the validity of remote cybersickness human-subjects research. Leveraging the larger remote dataset, we additionally examined demographic and individual-difference factors associated with cybersickness. These analyses confirm at scale the effects of sex, sickness susceptibility, and sickness expectation reported in smaller laboratory samples, and they add well-powered evidence on the contested relationship between age and cybersickness. These findings demonstrate that the VERA platform provides a viable means of remotely replicating laboratory-based studies and highlight its ability to support large, demographically diverse participant samples. This work establishes a validated methodological foundation for future large-scale remote studies of cybersickness and other VR research topics.

0.20

Breaking the Modality Barrier: Multimodal Fusion With Missing Modalities for Cybersickness Prediction

cs.HC ·2026-11-05 ·Purnata Saha, Rifatul Islam, John Quarles
similarity 0.62
Abstract

Cybersickness is a major barrier to comfortable VR use, and reliable prediction often requires multiple physiological and behavioral sensors. However, existing models typically assume a fixed set of modalities, making them vulnerable when sensors are unavailable and difficult to generalize across datasets with different sensor configurations. We adapt a transformer-based model that handles arbitrary sensor combinations without imputing missing data. Anchor-based contrastive learning maps heterogeneous sensor embeddings into a shared latent space using eye tracking as the anchor modality, while masked self-attention excludes unavailable sensors during fusion. We evaluate our approach on three publicly available cybersickness datasets: VR.net, SIM21, and Blur-Rollercoaster, collected using different VR systems and sensor configurations. Across single-sensor dropout conditions, prediction error changes by less than 0.09 MAE. Joint training across all datasets achieves 0.51 MAE and 0.63 Pearson correlation, substantially outperforming single-dataset models. These results demonstrate robust and generalizable cybersickness prediction across diverse VR systems.

0.29

Measurement-Guided Conversion of Laboratory Eye-Tracking Data for VR Authentication

cs.HC ·2026-10-21 ·Md Arif Shahriar, Mehedi Hasan Raju, Oleg V. Komogortsev
similarity 0.60
Abstract · 19 pages, 5 figures, 6 tables

Eye-movement authentication in virtual reality (VR) needs longitudinal training data, yet most such datasets come from lab trackers. We convert lab recordings to a VR headset's signal quality while keeping their eye movement, using only unpaired VR recordings of other people. Measurements show that the headset's added noise dominates above 7.8 Hz and that its quality is consistent within a person. A parametric device model re-creates the headset's sampling, a person-consistent calibration error and spectrally shaped noise, and a frequency-locked diffusion renderer re-textures that high-frequency noise. Converted GazeBase recordings match GazeBaseVR in noise level and accuracy, keep their source's saccade dynamics, and are harder to tell from real VR data than two prior conversions. An authenticator trained only on converted data verifies unseen VR users at a 5.9% equal error rate with 45 s of gaze, close to real VR training (5.8%); with 5 s, a gap remains.

0.31

Usability, User Experience, and Acceptability of the Trail Making Test in Virtual Reality in Younger and Older Adults

cs.HC cs.CY ·2026-10-16 ·Panagiotis Kourtesis, Dante O'Connor, Sarah E. MacPherson
similarity 0.59
Abstract · 20 pages, 3 figures, 4 tables, supplementary material are included

Immersive virtual reality (VR) adaptations of neuropsychological tests change how a test operates. Before their scores are interpreted, the individuals they are intended to assess should find them usable, acceptable and tolerable, and for older adults this evidence is usually missing. This study evaluated the experience of the Trail Making Test in Virtual Reality (TMT-VR), a head-gaze adaptation of the Trail Making Test that requires no hand-held controller, in 47 younger (20-38 years) and 44 older adults (64-81 years). After the task, participants rated usability, pragmatic and hedonic user experience, acceptability, and cybersickness. The study had three aims: to compare the two age groups on these ratings; to examine whether the ratings were associated with age group, gaming and technology experience, and whether cybersickness was associated with motion sickness susceptibility; and to examine whether the ratings were related to TMT-VR completion and error-adjusted times. Both groups rated the TMT-VR as highly usable, acceptable and pleasant to use. Older adults gave slightly lower usability and pragmatic ratings, but neither the age-group differences nor the associations with age group or previous experience were statistically significant after correction. Cybersickness was low, with 38 of the 91 participants reporting no symptoms; it did not differ between the age groups and was not associated with motion sickness susceptibility. No correlation between the ratings and TMT-VR performance survived correction. The TMT-VR with head-gaze selection is therefore usable, acceptable and well tolerated by older as well as younger adults. Because the ratings were favourable across the whole range of TMT-VR scores, slower or less accurate performance is unlikely to reflect difficulty with the interface.

0.37

GazeAgent: VLM-Guided Implicit Gaze Calibration from Egocentric Multimodal Behavior for AI Glasses

cs.HC cs.CV ·2026-10-17 ·Yuhong Zhang, Khanh An Nguyen, Xinyu Tian, KungYi Chang, Abraham Padua +4 more
similarity 0.59
Abstract · 27 pages, 14 figures, 3 tables

AI glasses typically require explicit, user-specific eye-tracker calibration, and accuracy can drift when the device shifts during use. We present GazeAgent, a VLM-guided framework that continuously and adaptively improves gaze-calibration accuracy from naturally occurring behavior without asking users to interrupt their activities. GazeAgent identifies precise visual attention (PVA) events from multimodal streams of inertial measurement unit (IMU), gaze, and wearer-hand signals, validates their task relevance, and localizes functional targets as pseudo-calibration targets. In a 10-participant scripted study, the system detected all 820 predefined PVA opportunities and, under device disturbance, reduced median gaze error by 44.1% compared with explicit calibration. In a five-participant case study, autonomous calibration produced the lowest workload and interruption ratings, and all participants preferred it for routine use. By deriving task-critical targets from natural multimodal behavior, GazeAgent demonstrates the potential for continuous, adaptive, and low-burden gaze interaction on egocentric AI glasses.

0.08