CS Paper Radar

LWCal: Loss-Weighted Calibration for Tabular Classifiers with Noisy Calibration Labels

Zeming Liu, Hang Lyu, Jingtao Zhang, Yuan Xie

cs.LG cs.AI ·submitted 2026-09-22 00:41 UTC · v1
published

Abstract

Post-hoc probability calibration is usually evaluated under an optimistic assumption: the held-out calibration labels are clean. In many AI deployment settings, however, labels come from weak annotators, historical decisions, heuristics, or distant supervision, so the same label noise that corrupts training also corrupts calibration. We study this overlooked failure mode for tabular classifiers and propose LWCal, a CPU-only post-hoc calibrator that down-weights calibration examples whose noisy labels are contradicted by the base model's held-out probability. LWCal requires no clean validation labels, no noise-rate estimate, and no retraining of the base classifier. A second variant, Gated-LWCal, adds a conservative disagreement gate that backs off toward the raw score when the calibration split appears extremely inconsistent. On nine local binary tabular tasks, six random seeds, symmetric and asymmetric label corruption, and three tree-based base learners, LWCal obtains the lowest average calibration error while Gated-LWCal obtains the best average proper-score tradeoff. In the main random-forest study over 432 noisy cells, Gated-LWCal reduces expected calibration error from 0.188 to 0.122 and negative log likelihood from 0.438 to 0.396 relative to the raw classifier. Paired bootstrap intervals for Gated-LWCal versus raw, Platt, isotonic, and beta calibration exclude zero on ECE, Brier score, and NLL. The artifact contains all scripts, result tables, figures, and the compiled paper.

Comment
8 pages, 7 figures. Accepted at the 38th IEEE International Conference on Tools with Artificial Intelligence (ICTAI 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Hard or Mislabeled? Failure Screens Enrich Vision Benchmarks for Label Errors

cs.CV cs.AIcs.LG ·2026-11-14 ·Haolin Guo
benchmark similarity 0.63
Abstract · 28 pages, 5 figures, 16 tables

Hard vision benchmarks often keep images that strong classifiers get wrong. Since a classifier is also marked wrong when the label is wrong, such failure screens may collect label errors. We measure this on ImageNet's twice-relabeled validation set with 103 classifiers. Among the 1,892 images that all 66 supervised classifiers get wrong, 61% have a wrong label, versus 11.1% overall. The fewer images a screen lets through, the more of them are mislabeled, along approximately one curve. Fit on one model family, this curve predicts the screens of two held-out model families with a mean error of 2.4 percentage points, and replays of ImageNet-D's and ImageNet-Hard's screens within 0.1 and 6.3 points. On new pools, ImageNet-V2 and CIFAR-10, enrichment at the strictest screens is stronger than the curve predicts: on ImageNet-V2, by human relabeling, 67% of the images that all 66 classifiers get wrong are mislabeled, against 46% predicted. Screens that let models choose among only some of the classes, as ImageNet-A's does (200 of 1,000), fall below the curve. By ReImageNet, 32% of ImageNet-Hard's ImageNet images have no correct label. ScreenAudit, which comprises an audit tool, a script that rebuilds corrected answer sets for the 5,464 decided ImageNet-Hard images (of 5,646) from ReImageNet's gated release, and per-image audits of 1,198 benchmark images, will be released later.

0.35

Adaptive Ensemble Selection for Noisy Labels on Tabular Data

cs.LG ·2026-09-26 ·Faizaan Ali, Inwon Kang, Oshani Seneviratne
benchmark similarity 0.62
Abstract

Incorrect or corrupted labels in tabular datasets can significantly degrade supervised learning performance, particularly when mislabeling is subtle and not easily detectable from feature space alone. In the context of automated or AI-augmented data science workflows, robust detection of such label noise is critical for building reliable models. We propose a data-centric reasoning module for AI data science systems that automatically diagnoses dataset quality and selects appropriate cleaning strategies. Given a dataset, a meta-model predicts weights over a diverse set of detectors, including confidence-based, neighborhood-based, and distributional methods. Across benchmark datasets with controlled noise, our approach achieves performance comparable to a Confident Learning baseline on average, with dataset-dependent gains and losses, particularly in heterogeneous regimes. We further show that detector effectiveness is systematically linked to dataset properties. These results demonstrate the value of descriptor-driven, data-centric ensembling as a component of AI-assisted data-science pipelines for robust dataset assessment and model reliability.

0.23

Calibration-Constrained Diagnostics for Evaluating LLM Self-Evaluation

cs.AI ·2026-11-01 ·Jae Oh Woo, Mengdie Flora Wang, Rahul Ghosh, Baishali Chaudhury, Mun Young Kim
publishedcode/data similarity 0.59
Abstract · 38 pages, 7 figures, 17 tables. Extended and substantially revised version of the non-archival NeurIPS 2025 LAW Workshop paper "Can LLMs Rel…

We introduce a reusable evaluation artifact for diagnosing whether LLM self-reported confidence can support confidence-gated act-or-defer decisions. The artifact is designed for evaluation rather than safety certification: it provides a black-box protocol, prompts, judge-reference labels, model outputs, reproduction scripts, and calibration-constrained diagnostic metrics for auditing LLM self-evaluation across math, factual, and commonsense reasoning tasks. Our central finding is that aggregate uncertainty summaries can produce deployment-misleading rankings: a model that appears strongest under standard aggregate calibration metrics can fail under category-level calibration constraints, while a model with worse aggregate calibration can exhibit stronger calibration-constrained behavior in the positive-margin region where high self-selection accuracy and tight calibration coexist. To expose this failure mode, we define PVC and C-PVC as category-level diagnostics over an accuracy-by-calibration surface: PVC counts categories whose self-evaluation accuracy exceeds a threshold, while C-PVC additionally requires category-level calibration error below a tolerance. We aggregate these diagnostics using Volume Under Surface (VUS) and a positive-margin restriction; they are VC/fat-shattering motivated but are empirical evaluation proxies, not literal VC-dimension estimates. Across 13 models and four benchmarks, the artifact shows weak confidence-correctness separation, stable diagnostic rankings under alternative categorizations and judge-label perturbations, and persistent positive-margin failures not captured by ECE or Brier score. Confidence-gated self-evaluation therefore requires calibration-constrained, category-level diagnostics, and we provide a reusable artifact for applying them under black-box access.

0.62

Regime-Conditional Verification: Correctness Estimation for Adapting and Monitoring Safety Classifiers

cs.AI cs.CLcs.CRcs.LG ·2026-08-14 ·Thiago Sandoval, Ufuk Topcu
benchmarkcode/data similarity 0.59
Abstract · 18 pages including technical appendix, 6 figures. Project page and code: https://rcv.tsandoval.com

Safety classifiers deployed with large language models often fail for two reasons: their decisions reflect the policy learned during training rather than the deployer's desired policy, and their performance degrades as deployment traffic evolves. We present Regime-Conditional Verification (RCV), a lightweight wrapper that adapts an off-the-shelf safety classifier without retraining it. RCV estimates, from the classifier's internal representations, the probability that each prediction disagrees with the deployer's policy, and selectively corrects predictions likely to be wrong. The same correctness estimates also provide a label-free signal for detecting distribution shift, enabling a maintenance loop that updates the correctness estimation layer and resorts to classifier fine-tuning only when repair fails within a label budget. Across three off-the-shelf safety classifiers and two benchmark datasets, RCV improves adherence to the deployer's policy in every classifier-dataset combination, catching up to 0.81 of previously missed unsafe content without modifying the underlying classifier. In a deployment study with ten attack campaigns, each a harm category held out of RCV's training, RCV detects every campaign in a dedicated injection panel; in the maintenance census most drift episodes are repaired without updating the classifier, and the fine-tune is reserved for the residual episodes.

0.26

AutoRefine: Auto-Calibrating Code Judges from Workflow Outcomes

cs.AI cs.SE ·2026-11-06 ·Shervin Shahidi, James Poon, Hang Xie, Kenneth O. Xu, Robin Håkanson +3 more
similarity 0.59
Abstract · 5 pages, 3 figures, prepared for submission to CAIN 2027 industrial track

LLM judges increasingly serve as quality gates for code changes that have no test oracle, but a judge prompt must be calibrated for its task and recalibrated as the system it judges evolves, while hand labels for the calibration are resource intensive and go stale. Development workflows emit outcome labels for free (tests pass or fail, changes land or are abandoned), but these labels are noisy. We present AutoRefine, a loop that rewrites a deployable judge's prompt to reproduce outcome labels, with an informed teacher that sees the judge's input plus the outcome, explains each label it keeps, and abstains when the outcome cannot be explained from what the judge sees. On a held-out dataset with an execution oracle, calibration raised chance-corrected agreement (Scott's $π$) from 0.36 to 0.60. On a deployed agent's outcome labels, with 25\% flipped at random to introduce noise, the teacher set aside flipped \textsc{fail} labels at more than twice the rate of genuine ones, cutting overall label noise from 25\% to 20\%. Recalibrating that agent's judge using AutoRefine raised its agreement with merge/abandon outcomes on 17 independently held-out diffs from the current workflow ($π$ 0.16 to 0.51); on 16 diffs from older workflows, the previous judge stayed ahead, illustrating the need for recalibration as the agent evolves. By abstaining, the teacher not only removes noisy labels but also flags changes whose outcome the judge's input cannot explain, telling a team when a judge needs better inputs rather than a better prompt.

0.15

Let Confidence Change, Not the Prediction: Prediction-Preserving Repair for Post-hoc Calibration

cs.LG cs.CV ·2026-09-01 ·Daehwan Kim, Haejun Chung, Ikbeom Jang
code/data similarity 0.59
Abstract

Post-hoc calibration corrects reported confidence, yet a multiclass calibrator can also change the associated top-1 prediction. Accuracy captures only the net effect of these changes on correctness, not how often predictions change; the Top-1 Prediction Change Rate (TPCR) instead measures this frequency. We propose Calibrator-Output Repair for Top-1 Decision Preservation (CORD), the first post-fit adapter to impose exact prediction preservation by repairing the full calibrated probability vector. From the original and calibrated outputs alone, CORD determines the mass assigned to the original top-1. The calibrated conditional distribution allocates the remaining mass over the other classes, yielding a repaired vector whose own argmax recovers the original prediction. On the calibration split, CORD coordinates the repaired masses to retain the calibrated outputs' mean mass on original predictions whenever attainable. The adapter alters neither the fitted calibrator nor its direct output, fits no additional supervised map, and requires no user- or validation-tuned hyperparameter. Across CIFAR-10/100 and ImageNet-1K, CORD attains zero TPCR by construction and lowers mean ECE, NLL, and Brier relative to the corresponding direct outputs in every dataset; paired gains persist under distribution shift and across calibration-set sizes. CORD thus removes the preservation constraint from calibrator fitting and assigns exact recovery of the original decision to subsequent output repair. Our code is available at https://github.com/labhai/CORD.

0.40

Beyond Confidence: Rethinking Uncertainty Calibration in Deep Code Models

cs.SE ·2026-10-15 ·Ravishka Rathnasuriya, Wei Yang
similarity 0.59
Abstract

Deep learning models have shown significant promise in code-related tasks. While confidence calibration techniques have been proposed to improve model reliability, their effectiveness in real-world tasks with strict accuracy requirements remains uncertain. In this paper, we investigate two key questions: first, whether existing measurement metrics, including confidence scores and uncertainty metrics, are effective for guiding selective prediction; and second, whether existing calibration techniques can improve these metrics to better identify cases where model predictions are likely to succeed or fail. We conduct a systematic study on defect prediction and vulnerability detection using seven code models, evaluating thirteen uncertainty signals and three widely used post-hoc calibration methods. Our analysis reveals three major findings: (1) even strong uncertainty signals can remain poorly calibrated and provide limited separation at the high-confidence end, constraining selective prediction in practice; (2) standard post-hoc calibrators often improve calibration scores but do not consistently translate into better selective prediction behavior; and (3) commonly used calibration metrics can disagree with selective prediction performance, underscoring the need to evaluate both jointly. Moreover, our findings motivate a decision-oriented view of reliability in deep code models, where calibrated scores must be evaluated together with selective-prediction quality and retained-region risk before they can support accept--defer deployment.

0.34

Calibration in One Go: Jointly Learning Accurate and Calibrated Neural Networks

cs.LG cs.AIstat.ML ·2026-10-09 ·Nektarios Kalampalikis, Pablo M. Olmos, Isabel Valera
similarity 0.58
Abstract · 27 pages, 7 figures

Neural networks (NNs), while highly flexible and versatile, are often poorly calibrated. Post-hoc calibration methods adjust the outputs of an already trained model using a separate calibration dataset and additional calibration parameters. This process adds overhead that requires separate optimization of the calibrator and subsequent model selection. In this paper, we show that standard (post-hoc) calibrators can be trained end-to-end with the backbone via a bilevel Stackelberg formulation. This formulation eliminates the need for a separate calibration set or a dedicated calibration loss by jointly optimizing accuracy and calibration using cross-entropy, introducing only one additional hyperparameter: the calibrator learning rate. Although our framework supports calibrators ranging from temperature and matrix scaling to NN layers, our results show that using the final classification layer itself as the calibrator yields accurate, well-calibrated models with no additional parameters. Our approach outperforms SOTA calibrators with minimal added complexity, while also avoiding the multiplicative overhead of separate calibration components in settings such as multi-task learning.

0.29