CS Paper Radar

NV-Reason-CT: 3D Visual Language Model for CT Analysis

Andriy Myronenko, Dong Yang, Yucheng Tang, Baris Turkbey, Benjamin Simon, Stephanie Harmon, Rikhil Makwana, Mariam Aboian, Sena Azamat, Ibrahim Ethem Hamamci, Sezgin Er, Bjoern Menze, Zongwei Zhou, Wenxuan Li, Marc Edgar, Yufan He, Pengfei Guo, Daguang Xu

cs.CV cs.AI ·submitted 2026-09-23 08:09 UTC · v2
highly cited

Abstract

We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.

Closest papers

Nearest neighbours by meaning across the whole index.

Instance-Guided Report Anchoring for Text-Free 3D Abnormality Segmentation in Chest CT

cs.CV ·2026-08-31 ·Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan +5 more
similarity 0.76
Abstract

Accurate 3D abnormality segmentation in chest CT requires dense spatial supervision, but obtaining expert voxel-level labels is costly. Radiology reports, however, are routinely generated during clinical interpretation and contain instance-specific descriptions that can provide additional guidance without new dense annotation. Existing vision-language grounding methods typically require report-derived findings at inference, making localization dependent on paired text and limiting each forward pass to a queried finding. We propose Instance-Guided Report Anchoring (IGRA), a model-agnostic module that preserves the correspondence between each annotated abnormality instance and the report finding that describes it. IGRA pools each instance representation and anchors it to the corresponding finding embedding during training; all text-related components are discarded at inference. We further reformulate free-text grounding on ReXGroundingCT as multi-label volumetric segmentation by merging same-category instances, allowing all abnormality categories to be predicted in one image-only forward pass. IGRA improves Dice by 22.5% over the strongest image-only baseline (30.93 vs. 25.25) and is comparable to VoxTell on the single-finding subset (30.29 vs. 30.43). Applied unchanged to four standard 3D segmentation backbones, IGRA improves Dice and hit rate across all architectures. Zero-shot evaluation on LIDC-IDRI, PleThora, and a private in-house dataset further shows consistent gains over image-only baselines.

0.17

Scaling 3D Visual Grounding in Abdominal CT

cs.CV cs.LG ·2026-10-02 ·Sam Church, Danyal Maqbool, Joshua D. Warner, Andrew Voter, Junjie Hu +2 more
similarity 0.74
Abstract

Visual grounding models can enhance radiology workflows by linking report findings to image regions. This is particularly valuable for 3D CT, where findings often occupy a tiny fraction of the volume. Training 3D grounding models requires large sets of paired phrases and regions, and building such datasets is expensive, requiring radiologists to annotate images by hand. We posit that this supervision is already created implicitly during routine reporting, as radiologists frequently place 2D annotations (e.g., distance measurement, arrows) on key images to make measurements and to support report interpretation. We introduce an automated pipeline that converts these routine clinical annotations into large-scale phrase-region supervision for 3D visual grounding. The pipeline links each annotation to the corresponding finding in the report through metadata matching, then uses a promptable 3D segmentation model to convert the 2D annotation into a volumetric mask. This produces phrase-mask-volume datasets without requiring additional radiologist annotation. Applied to a single institution's clinical picture archiving and communication system (PACS), our approach generated 105K phrase-mask-volume triplets from 59K abdominal CT exams. We also introduce two abdominal CT grounding benchmarks, LocusBench-Onc and LocusBench-ED, which comprise 240 oncology and 260 emergency-department radiologist-reviewed phrase-mask-volume triplets, respectively, with the latter spanning 13 distinct categories such as appendicitis, hematoma, and hernia. We further introduce LocusCT, a 3D visual grounding model trained on this dataset, which achieves hit rates of 0.725 on LocusBench-Onc and 0.773 on LocusBench-ED, substantially outperforming comparator models. These results show that routine PACS annotations are a scalable, previously unused source of supervision for 3D visual grounding.

0.08

A Modular Agent for Reliable and Auditable Spatial Relation Verification in CT Scans

cs.CV cs.AI ·2026-08-21 ·Simon Vincent Abel, Heiko Hillenhagen, Michael Götz, Timo Ropinski, Ayhan Can Erdur +1 more
publishedbenchmark similarity 0.73
Abstract

Reliable spatial understanding is an important prerequisite for future medical vision-language systems that aim to support radiological report generation and structured image understanding. While modern vision-language models (VLMs) show promising performance on many medical imaging tasks, recent evidence suggests they remain weak in controlled spatial reasoning and often fail to reliably ground spatial relations in image evidence. Given that radiological reasoning hinges on understanding the relative positions of anatomical structures and findings, this spatial weakness poses risks to diagnostic accuracy. We present a modular medical imaging agent for binary spatial relation verification in axial CT slices. Instead of directly predicting spatial answers end-to-end, the system decomposes the task into explicit stages: language parsing, anatomical localization, and deterministic geometric verification. Natural-language queries are converted into structured relation tuples, queried organs are localized with a YOLO-based detector, and the final spatial decision is computed from object centers using deterministic geometric rules. We evaluate the approach on the held-out MIRP spatial QA benchmark and compare it against representative end-to-end VLM baselines. The best-performing hybrid configuration reaches 94.1% accuracy and 94.2% F1, outperforming direct Qwen2-VL prompting by 42.5 percentage points in accuracy, while preserving interpretable intermediate representations and auditable reasoning stages. The results suggest that explicit modular spatial verification can serve as a promising building block for future report-oriented medical imaging agents.

0.31

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

cs.CV cs.AI ·2026-11-07 ·Szymon Płotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou +7 more
publishedcode/data similarity 0.72
Abstract · NeurIPS 2026

Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning. The code is available at https://github.com/gmum/A2MoE.

0.41

RepConTUR: A Report-Conditioned Volumetric Multimodal Model for Abdominal Tumor Segmentation

cs.CV ·2026-10-29 ·Seunghwan Lee, Sangjoon Park, Jongmin Lee, Yoon Jo Kim, Wonyoung Cho +2 more
code/data similarity 0.72
Abstract · Submitted to CVPR 2027

Tumor delineation is required for radiotherapy planning, yet automatic segmentation is limited by errors, predominantly false positives, that distort dose and increase editing time. The radiology report accompanies the scan and localizes disease at the suborgan level, but existing text-promptable models condition on short referring phrases, and most operate in 2D. We present RepConTUR, a single native-3D early-fusion multimodal model that conditions volumetric abdominal tumor segmentation on the narrative report. We extend AbdomenAtlas 3.0 to a suborgan-level promptable segmentation dataset and generate report-based VQA pairs, yielding four report-derived tasks on the same annotations: referring segmentation (RES), report-grounded segmentation (GSEG), report generation (RRG), and visual question answering (VQA). We train RepConTUR, comprising a 3D CT encoder, an early-fusion language model, and a native-3D segmentation module, jointly on the four tasks. Across liver, kidney and pancreas, RepConTUR attains the highest Dice similarity coefficient (DSC), instance-wise precision, and detection F1 among the text-promptable baselines, and adding the report raises mean precision while leaving recall comparable. Against two vision-only specialists, nnU-Net and the report-supervised R-Super, RepConTUR attains the highest value on every in-domain metric for liver and pancreas and the highest mean DSC, recall, precision, and detection F1 over the four out-of-distribution public cohorts. Ablations indicate that conditioning on the narrative report raises detection F1 from 0.499 to 0.528 within the same model, that joint GSEG training raises RES F1 from 0.450 to 0.482, and that the native-3D segmentation module raises GSEG F1 from 0.139 to 0.528 over its 2D counterpart. Code is available at https://github.com/Oncosoft-Research/RepConTUR.

0.20

HeiCo-FOCUS: A Clinically Grounded Dataset for Long-Context Video Understanding

cs.CV ·2026-10-07 ·Leon Mayer, Lucas Luttner, Patrick Godau, Kai Fritzsche, Annika Reinke +40 more
benchmarkdatasetcode/data similarity 0.72
Abstract · 28 pages, 9 figures, 5 tables. Code: https://github.com/IMSY-DKFZ/orena-focus

Recent advances in Vision-Language Models (VLMs) have led to rapid progress in video understanding across a wide range of benchmark tasks. However, existing evaluations largely focus on short-term reasoning, failing to assess a critical capability: maintaining cumulative temporal consistency over extended time horizons. To close this evaluation gap, we introduce HeiCo-FOCUS, a clinically grounded dataset for evaluating long-context video understanding through the task of Foreign Object Contextual Understanding in Surgery. Built on a dataset of Heidelberg Colorectal surgeries, this task requires models to continuously track multiple objects as they are inserted, manipulated, occluded, and removed over procedures lasting up to hours. HeiCo-FOCUS comprises 30,000 visual question answering (VQA) pairs covering five core capabilities: object recognition, temporal grounding, aggregation, event and procedural understanding, and complex reasoning. The dataset was constructed through a rigorous multi-stage annotation pipeline involving large-scale crowd annotation and 39 surgical domain experts to ensure high quality and clinical relevance. To systematically probe model behavior, we introduce a multi-track evaluation framework that progressively increases temporal and contextual demands from single frames to full procedures. Experiments with ten frontier VLMs show that HeiCo-FOCUS tasks are far from solved: only around half of the models clearly outperform a text-only baseline. Across the video tracks, models perform best on event and procedural understanding (mean Accuracy: 56.5% across all models), while temporal grounding remains particularly challenging for all evaluated models (mean Accuracy: 19.7%). We therefore expect HeiCo-FOCUS to serve as a catalyst for the development of models capable of reliable, temporally consistent reasoning over hours-long videos.

0.27

ORGANIC3D: Grounding 3D CT Vision Language Models in Organ Level Image Text Coupling

cs.CV ·2026-11-17 ·Zelong Liu, Hamza Ahmed, Wynn Wingyi Lee, Mickael Torjman, Alexander Dimitrakakis +5 more
benchmark similarity 0.72
Abstract

Vision language models (VLMs) have achieved strong performance in 3D computed tomography (CT) classification, but high accuracy does not reflect whether their predictions rely on the correct anatomical evidence. We introduce ORGANIC3D, a framework for evaluating and improving organ level image text alignment through controlled anatomical interventions. Our benchmark assesses 12 vision encoder checkpoints and 7 generative VLMs using matched patient comparisons, organ erasure, lesion replacement, and laterality perturbations, revealing substantial alignment failures even among top performing models. To learn organ level image text correspondence, ORGANIC3D aligns each finding sentence with the anatomy aware image features and trains on edited scans to anchor this alignment in the organ's image evidence. We further extend this framework to generative VLMs, promoting evidence dependent question answering and report generation. Trained exclusively on public data, ORGANIC3D achieves SOTA classification AUROC on CTRATE, Merlin, and the heldout RADChestCT dataset and reaches 77% laterality accuracy, compared with at most 66% for prior models. Its generative VLM matches or exceeds all evaluated publicly released VLMs on visual question answering, achieves the highest report accuracy, and retracts 96 to 99% of target organ findings after organ removal, versus a maximum of 69% for other models. Together, these results establish ORGANIC3D as a framework for testing whether 3D CT vision language models ground their predictions in anatomical evidence and for improving organ level alignment alongside predictive accuracy.

0.23

From Generalist to Specialist: A Context-Fusion Framework for Endoscopic Polyp Reporting with a Frozen VLM

cs.AI cs.CV ·2026-08-16 ·Ruijie Yang, Yan Zhu, Peiyao Fu, Siyuan Li, Te Luo +5 more
similarity 0.72
Abstract

Reliable endoscopic polyp reporting requires integrating quantitative lesion sizing, standardized Paris classification, and clinically meaningful morphological description within a single record. General-purpose vision-language models (VLMs) offer a unified interface for image understanding and report generation. Existing specialization strategies, however, typically rely on task-specific models or model-weight adaptation, leaving unresolved how to introduce reliable specialist knowledge while preserving both this unified interface and the VLM's pretrained capabilities. We introduce a context-fusion framework that specializes a frozen general-purpose VLM through both implicit instruction context and explicit transduction context without modifying its pretrained weights. Specifically, a self-supervised polyp encoder retrieves related image-report pairs as explicit, query-specific evidence, while learned continuous specialist tokens provide implicit instruction context shared across cases. Experiments were conducted on 2,056 expert-annotated public endoscopic images. We compared the framework with general-purpose VLMs, task-specific predictors, and weight-adaptation methods to assess specialist performance, unified reporting, and adaptation efficiency. Across numerical, categorical, and report-generation metrics, the proposed framework substantially improved direct frozen-VLM inference and achieved the strongest overall performance among the evaluated methods. It added trainable parameters equal to only 0.006% of the frozen VLM's parameter count. When the top-1 retrieved case carried the correct target category, our framework corrected 70.5% of the errors made by a weight-adaptation baseline. These findings support the context-fusion framework as a lightweight and effective strategy for specialist adaptation of a frozen VLM.

0.04