Safe Receding Horizon Mixed-Integer Differentiable Predictive Control for Degradation-Aware Battery Dispatch

Eshagh Safarzadeh Ravajiri, Jan Drgona, Benjamin F. Hobbs

eess.SY ·submitted 2026-09-23 18:36 UTC · v1
publishedbenchmark

Abstract

We present a safe receding-horizon mixed-integer differentiable predictive control methodology for residential battery energy storage dispatch that combines neural-network speed with recursive feasibility guarantees. Unlike open-loop learning-to-optimize methods, it incorporates real-time state-of-charge feedback and sinusoidal time-of-day conditioning, enabling closed-loop re-planning at every timestep without re-solving a mixed-integer program. A differentiable rainflow cycle-counting layer enables self-supervised training of the mixed-integer policy on exact degradation physics. The controller is a hybrid closed-loop system pairing a neural mode-selection and continuous-action policy with a quadratic-programming safety filter that guarantees recursive feasibility independent of network weights or mode optimality. We establish mode-conditioned Lipschitz continuity and a conditional regret decomposition into training-quality, mode-mismatch, and forecast-error terms. On a 7-day net-metering evaluation, the method attains a 6.9% cost gap versus the closed-loop mixed-integer MPC benchmark with a 25x speedup (0.11 s vs 2.7 s per step), while average regret rises by under 4% across 0-30% forecast noise. The learned and benchmark modes agree at every step, so the bound reduces to its training-quality and forecast-error terms, both empirically validated.

Comment
6 pages, accepted to the 65th IEEE Conference on Decision and Control (CDC 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

End-to-End Battery Dispatch with Exact Rainflow Degradation via Mixed-Integer Differentiable Predictive Control

eess.SY ·2026-09-11 ·Eshagh Safarzadeh Ravajiri, Jan Drgona, Mahdi Mehrtash, Benjamin F. Hobbs
top venue similarity 0.85
Abstract · 12 pages. Submitted to IEEE Transactions on Smart Grid

Optimal dispatch of battery energy storage systems requires balancing energy arbitrage against cycle-induced degradation, which is accurately quantified through rainflow cycle counting. However, rainflow's combinatorial, nondifferentiable algorithm is incompatible with both convex optimization and gradient-based neural network training. We present a self-supervised mixed-integer differentiable predictive control framework that trains neural policies directly on exact rainflow degradation through a novel differentiable rainflow layer combining exact gradients at state-of-charge extrema with dense proxy gradients on incremental changes, enabling stable end-to-end training while preserving true degradation physics. A mixed-integer differentiable architecture enforces power balance, dynamics, and mode exclusivity, with a safety filter guaranteeing constraint satisfaction. We evaluate the framework on 3,650 real battery-day scenarios (a 10-battery fleet over 365 days) spanning three utility regions (SDG&E California, Xcel Energy Colorado, APS Arizona) with diverse time-of-use pricing structures. A single-battery trained policy achieves a 0.35% performance gap on its training distribution with over 200x speedup, while fleet-wide training generalizes across all households and utility regions, achieving a 3.33% performance gap with 564x computational speedup (62 seconds vs. 9.7 hours) and 100% feasibility. The millisecond-scale inference reduces computation by over two orders of magnitude compared to mixed-integer solvers, enabling practical deployment at scale.

0.71

Hierarchical Control via MPC-RL for Multi-Timescale Battery Systems

eess.SY ·2026-10-02 ·Rasa Pourjam, Ehecatl Antonio del Río Chanona, Paulina Quintanilla
similarity 0.74
Abstract

Multi-timescale systems present a fundamental challenge, where fast operational decisions must coexist with long-horizon sustainability targets. In this work, we propose a new hierarchical control framework via Model Predictive Control (MPC) and Reinforcement Learning (RL) to separate decision-making on two distinct timescales. The high-level MPC optimizes long-horizon setpoints at the slow dynamic and on a fast timescale, a low-level pretrained RL agent tracks these setpoints in real time to maximize short-term objectives. RL is introduced to learn nonlinear control policies, without relying on model linearizations or requiring the heavy online computation from solving repeated optimal control problems. The framework is applied to a Battery Energy Storage System (BESS) operating in frequency regulation markets to balance fast profit opportunities (seconds) and slow battery degradation (weeks to months). The design employs a degradation-aware RL agent trained offline to generate safe long-horizon setpoints, and a degradation-unaware agent fine-tuned from it for fast runtime setpoint tracking. Compared to MPC baselines, the proposed approach successfully extends battery lifetime by 84% and increases operational profit by 34%.

0.17

Learning Control Policies from Heterogeneous Multi-Horizon Time Series in Battery Energy Management Systems

eess.SY ·2026-09-18 ·Sheng Yin, Vivek Teja Tanjavooru, Holger Hesse, Christoph Goebel
published similarity 0.72
Abstract

This paper introduces Representation-to-Decision (R2D), an end-to-end imitation learning framework that maps heterogeneous multi-horizon time-series inputs directly to battery control decisions through modular Temporal Feature Extractors (TFEs) and a shared latent representation, without an explicit load and PV forecasting step. While accurate forecasting improves prediction quality, optimal control performance remains unguaranteed in prediction-then-optimization pipelines; standard Reinforcement Learning (RL) lacks the long-horizon temporal awareness due to short-window observations, even when forecast signals are available as additional inputs. R2D offers a different perspective: rather than forecasting first and deciding second, it learns to decide directly from raw temporal inputs, with control optimality anchored by an aging-aware Mixed-Integer Linear Programming (MILP) expert through Behavior Cloning (BC). Benchmarked against six controllers on a high-fidelity electro-thermal battery simulation across five industrial sites, R2D achieves 62--77\% of the global clairvoyant optimum, outperforms the tested Model Predictive Control (MPC) and RL benchmarks, and yields battery degradation nearly identical to its MILP teacher across all five sites. Comprehensive ablation studies over temporal backbone, model size, expert formulation, aging-cost weighting, and horizon configuration confirm that an LSTM encoder with a 15-minute single-step control horizon provides the most robust and deployment-ready configuration, and cross-site and single-factor out-of-distribution tests show that generalization to unseen profiles is profile-dependent, with policies trained on high-activity sites transferring most reliably.

0.26

Comparative Evaluation of MILP, MPC, and Reinforcement Learning for Commercial Battery Dispatch Under Time-of-Use Tariffs

eess.SY ·2026-09-13 ·Hafiz Majid Hussain, Wajiha Samar, Lurian Klein, Pedro Nardelli
benchmark similarity 0.71
Abstract

Battery energy storage systems (BESS) paired with rooftop photovoltaics (PVs) can deliver measurable cost savings under time-of-use (TOU) electricity tariffs; however, the relative performance of model-based and model-free dispatch strategies remains insufficiently benchmarked on full-year, real-world commercial datasets. This paper presents a full-year (2023) comparative evaluation of three BESS dispatch approaches using data from a commercial PV installation operating under a TOU tariff. The examined strategies include: (i) a mixed-integer linear programming (MILP) formulation with perfect foresight, providing an oracle performance benchmark under the assumed model; (ii) a model predictive control (MPC) scheme based on a day-ahead persistence forecast, representing a low-complexity deployable approach; and (iii) a soft actor-critic (SAC) deep reinforcement learning agent trained under causal information constraints. The MILP benchmark achieves an annual cost reduction of 24.6\% relative to a no-storage baseline. The persistence-based MPC approach recovers 99.2\% of this benchmark using only prior-day data. In contrast, the evaluated SAC agent yields an annual cost higher than the no-storage baseline. This outcome is analyzed in the context of known challenges in reinforcement learning for energy systems, including limited observability and reward design. Overall, the results indicate that, for the studied dataset and tariff structure, persistence-based MPC captures nearly all achievable economic benefits under practical deployment constraints, whereas the considered RL configuration does not yield competitive performance under the same information limitations.

0.21

Frequency-Calibrated Decision-Focused Learning for BESS Dispatch Under Renewable Uncertainty

eess.SY ·2026-10-30 ·Zihan Meng, Chenxi Hu, Xin Cui, Francis Yunhe Hou
hot direction similarity 0.70
Abstract

Battery energy storage system (BESS) flexibility depends on state of charge and intertemporal operating constraints. Renewable forecast errors of similar magnitudes can lead to different BESS dispatch results. An error may alter early charging or discharging decisions and reduce the flexibility available for subsequent regulation, while another may have little effect on the resulting schedule. To account for these unequal consequences, this paper proposes Frequency-Calibrated Decision-Focused Learning (FC-DFL), which trains renewable predictors using the realized operating costs of their induced BESS schedules. Gaussian smoothing and solver-based zeroth-order estimation provide training feedback without requiring differentiating through the non-differentiable mixed-integer BESS dispatch problem. The same decision feedback is further combined with prediction sensitivity to develop a decision-oriented XAI method that identifies the input features and forecast periods most consequential to BESS operation. Case studies using German wind and solar data show that FC-DFL reduces the integrated absolute frequency-deviation metric by 6.05% and decision regret by 23.92% relative to accuracy-based predict-then-optimize method. The XAI analysis further demonstrates that the identified high-impact forecast periods produce 2.84 times larger average absolute changes in realized operating cost than low-impact periods. These findings highlight the importance of incorporating downstream decision-making outcomes into renewable forecasting and demonstrate the value of FC-DFL in improving BESS regulation and providing operationally meaningful forecast explanations.

0.24

Mixed-Integer Nonlinear Differentiable Predictive Control for Underground Pumped Hydro Energy Storage Systems

eess.SY cs.LG ·2026-09-16 ·Honghui Zheng, Ján Boldocký, Yury Dvorkin, Ján Drgoňa
published similarity 0.67
Abstract · 6 pages, 5 figures. Accepted for publication in the 2026 65th IEEE Conference on Decision and Control (CDC)

This paper extends Mixed-Integer Differentiable Predictive Control (MI-DPC) to multi-modal discrete decisions and nonconvex polynomial dynamics arising in Underground Pumped Hydro Energy Storage Systems (UPHES). A neural policy mapping problem parameters to continuous setpoints and integer mode selections via a Gumbel-Softmax layer is trained in a self-supervised manner by differentiating the expectation of the finite horizon control objective through the nonlinear dynamics model. Three methodological contributions enable this extension: a parallel differentiable simulator that preserves gradient magnitude, a Transformer encoder that captures long-range temporal dependencies, and a Gumbel-Softmax temperature annealing schedule that regularizes the combinatorial search. We demonstrate the framework on day-ahead scheduling of a UPHES, a large-scale mixed-integer optimal control problem with nonlinear unit performance curves and volume-head coupling. MI-DPC achieves only 1.6% suboptimality relative to a piecewise mixed-integer quadratic programming baseline, while providing five orders of magnitude speedup in online scheduling time.

0.48

Decision-Focused Learning via Neural Optimization Layers for Battery-Assisted Grid-Import Smoothing in AI Data Centers

eess.SY cs.LGmath.OC ·2026-11-10 ·Xinda Zheng, Canchen Jiang, Frits de Nijs, Edward Lam, Markus Wagner
similarity 0.67
Abstract

Rapid AI data-center power fluctuations challenge grid integration. Sustained grid-import smoothing requires allocating limited battery power and energy under uncertain demand. We formulate risk-aware BESS scheduling that coordinates advance reserve commitments and demand-responsive dispatch, accounting for operating costs, grid-ramp penalties, and their conditional value-at-risk. We develop battery scheduling decision-focused learning (BS-DFL) with a constraint-aware neural optimization layer trained directly from this objective without optimal-solution labels. The trained layer is then frozen to guide demand-predictor learning through scheduling costs and ramping risk, enabling solver-free rolling-horizon scheduling. In a 10,000-minute simulation using loads derived from measured AI workloads, BS-DFL reduces mean absolute minute-to-minute grid-import changes by 71.70% and total scheduling cost by 18.01% relative to an MSE-trained predictor coupled with a mixed-integer linear programming solver, with an average decision time of 18.77 ms.

0.20

Differentiable Hybrid-Action Neural Feedback Control for District Heating Networks

eess.SY ·2026-10-01 ·Nicolas Kirsch, Corrado Sgadari, Alessio La Bella, Giancarlo Ferrari-Trecate
similarity 0.66
Abstract

Many cyber-physical systems require control policies that combine continuous setpoints with discrete operational de- cisions, such as equipment switching, mode selection, or resource scheduling. Discrete actions are not differentiable, which ob- structs gradient-based policy training, while conventional mixed- integer formulations remain costly to solve online. This paper proposes a hybrid-action neural controller (HANC) in which a continuous branch, a categorical branch and a differentiable assembly layer jointly generate commands that satisfy complex actuator constraints by construction. Categorical decisions are handled using a straight-through Gumbel estimator, enabling the policy to be trained by backpropagation through time over full closed-loop rollouts. The proposed framework is deployed on a district heating network (DHN) featuring multiple heat generation units and stratified thermal energy storage. Its performance is evaluated on a simulation of a real DHN located at RSE SpA in Italy. The resulting policy jointly learns switching decisions and continu- ous operating setpoints. Under dynamic electricity pricing, the learned controller reduces operating cost by 30% compared to a rule-based industrial baseline. We also show that, compared with a deterministic straight-through relaxation, injecting noise during training achieves similar cost while reducing hard switching by an order of magnitude, and attribute this difference to the wider decision margins of the resulting policy.