CS Paper Radar

Integrating Local Detail and Global Context: A Dual-Input Multi-Task Learning Framework for Bone Tumor Diagnosis

S. M. Nasif Uddin, Rusab Sarmun, Muhammad E. H. Chowdhury, Adam Mushtak, Israa Al-Hashimi, Sohaib Bassam Zoghoul

eess.IV cs.CV ·submitted 2026-09-23 19:19 UTC · v1

Abstract

Primary bone tumors are rare but clinically aggressive neoplasms whose diagnosis from radiographs is challenged by heterogeneous morphology, subtle lesion margins, and overlapping bone structures. To address the limitations of existing single-view models, we present a dual-input, multi-task learning framework that, to our knowledge, is the first to apply bidirectional cross-modal attention between a lesion crop and the full radiograph for joint segmentation and subtype classification. Using the multi-institutional Bone Tumor X-ray Radiograph Dataset (BTXRD, n=3,746), we employ a YOLO-based detector to generate regions of interest, which are paired with full images as inputs to a dual-stream DenseNet121 architecture. Features are integrated via a novel cross-modal attention fusion strategy, refined by Hierarchical Multi-scale Feature Fusion, effectively balancing fine-grained lesion detail with global anatomical context. Evaluated on a held-out patient-level test split, the model demonstrates superior performance over single-input baselines, achieving an overall Dice Similarity Coefficient of 0.896 and a macro-averaged classification F1-score of 0.928. Notably, the system exhibits exceptional sensitivity for malignant osteosarcoma (AUC 0.999), validating the potential of dual-stream context modeling to support radiologists in accurate, early decision-making.

Closest papers

Nearest neighbours by meaning across the whole index.

CXR-CMFA: A Cross-Modal Feature Aggregation Network for Chest X-Ray Pathology Classification

cs.CV cs.AI ·2026-11-06 ·Talukder Hasnat Zadid, Jahin Sultana, Felipe Bochini Brisola, Kishore Roy, Mysha Rahman +2 more
benchmark similarity 0.75
Abstract

Chest X-ray (CXR) interpretation remains challenging because subtle pathology can be obscured by overlapping anatomy, image-quality variation, and limited visual evidence in isolated radiographs. Although image-only deep learning models provide useful baselines, they discard the complementary diagnostic context available in radiology reports, while large vision-language models can be computationally expensive for practical deployment. This paper presents CXR-CMFA, a lightweight cross-modal feature aggregation network for binary CXR pathology classification. The proposed framework combines a dual-stream visual encoder, using EfficientNet-B0 for global anatomical representation and DenseNet-121 for local pathological detail, with a TF-IDF-MLP report encoder. Two fusion modules integrate these modalities: the Dual-Modal Spatial Attention Module (DMSAM) uses the report embedding to gate global and local visual features, and the Cross-Modal Gated Feature Fusion (CGFF) module learns per-instance weights for visual and textual contributions. Experiments on the MIMIC-CXR benchmark, using the provided train, validation, and test splits, show that CXR-CMFA achieves 93.45% accuracy, 99.88% precision, 91.8% recall, 95.7% F1-score, and 99.19% AUC on the held-out test set. The model produces only four false positives among 984 normal test cases, supporting its suitability for high-specificity screening workflows. An ablation study further demonstrates a 22.47 percentage-point AUC improvement over the global-image-only variant, confirming the value of adaptive cross-modal fusion. These results indicate that compact report-conditioned fusion can provide strong discriminative performance without relying on large pretrained language models.

0.14

Weakly-supervised Kidney Tumor Classification from CT Scans with Multi-Instance Learning and Anatomical Filtering

cs.CV ·2026-09-07 ·Joonas Ariva, Dmytro Fishman
similarity 0.71
Abstract · 16 pages, 3 figures

Deep learning models for CT scan analysis are often limited by the scarcity of precise pixel-level annotations, which require significant radiologist effort to produce. Training on scan-level labels alone reduces annotation requirements but introduces challenges: low supervision ratios and large input volumes make models prone to overfitting and shortcut learning. In this work, we investigate two complementary methods to address these challenges: multi-instance learning (MIL) and anatomical filtering. MIL divides CT volumes into 2D slice instances, enabling efficient 2D architectures with ImageNet pretraining rather than computationally demanding 3D models. Anatomical filtering uses Compass, our self-supervised body part regression model, to crop scans to pathology-relevant subregions without requiring segmentation masks. We evaluate two MIL frameworks - Attention-based MIL (ABMIL) and FocusMIL - on kidney tumor classification across one internal dataset (TUH) and two external datasets (KiTS23 and TCGA-KiRC). Our best models achieve F1 = 0.83 on the internal test set using only scan-level labels. We further show that anatomical filtering with the Compass model is critical for the out-of-distribution generalization of embedding-based ABMIL, while instance-based FocusMIL demonstrates greater inherent robustness to distribution shift. While evaluated on kidney tumors, we consider this a proof-of-concept for a broader weakly supervised CT classification pipeline applicable to other organs and pathologies.

0.16

CheXFuse: Guided Differential Joint Attention Fusion for Robust Multimodal Chest X-Ray Classification in Data-Scarce Medical Settings

cs.CV cs.LG ·2026-10-19 ·Muntaqim Ahmed Raju, Priyanka Siddappa, Md Shifat Haider Al Amin, Ruizhe Ma, Md Ripon Ahammed
publishedhighly cited similarity 0.70
Abstract · IEEE ICDM DMBIH 2026

A central challenge in multimodal learning is how to fuse modalities that differ substantially in predictive strength. When one modality provides a much stronger representation than another, indiscriminate cross-modal interaction can introduce weak, redundant, or unstable signals, limiting or even degrading performance relative to the strongest unimodal representation. To address this problem, we propose CheXFuse, a multimodal fusion framework based on Guided Differential Joint Attention (GuDJA). CheXFuse combines image and text token representations within a joint multimodal sequence, where learned token guidance emphasizes informative representations and differential attention reduces less useful attention responses. We evaluate CheXFuse on the Indiana University (IU) Chest X-ray dataset, using binary (normal vs. abnormal) classification as the downstream task. Experiments are conducted under both original-report and masked-report settings, with the latter serving as a controlled stress test under reduced textual informativeness. CheXFuse with GuDJA achieves the strongest mean overall performance across the evaluated baselines and ablations, reaching 95.73% accuracy, 95.79% F1-score, 96.54% recall, and 95.28% sensitivity at 95% specificity (Sens@95Spec) with original reports, and 95.58%, 95.60%, 95.60%, and 94.34%, respectively, under masked reports. These results suggest that GuDJA provides a promising fusion strategy under asymmetric or partially reduced modality informativeness.

0.49

Federated Multi-Task Learning for Bladder Tumor Segmentation and MIBC Classification Using a Hybrid CNN-Transformer Architecture

cs.CV ·2026-08-31 ·Malhar Udmale, Divyanshu Dwivedi, Aarohi Dhand, Sachin Dudda Nagaraju, Mayank Rai +1 more
similarity 0.69
Abstract

Accurate bladder tumor segmentation and assessment of mus- cle invasion from T2-weighted MRI are important for treatment plan- ning, but developing robust models across institutions is challenging be- cause patient data cannot be centrally pooled and imaging characteristics vary across scanners and acquisition protocols. We propose a federated multi-task learning framework for joint bladder tumor segmentation and MIBC/NMIBC classification across four clinical centers. The proposed Swin Hybrid model combines a ResNet-34 branch for local texture and boundary information with a Swin-Tiny Transformer for global anatomi- cal context. A segmentation-guided classification mechanism further uses tumor localization information to support MIBC prediction. We also investigate several augmentation strategies under both centralized and federated training to improve robustness to multi-center variability. Ex- periments on the FedBCa dataset show that the Swin Hybrid provides the best overall balance between segmentation and classification among the evaluated architectures. Under federated training, Geo+Elastic aug- mentation achieved a DSC of 0.8100 and a patient-level AUC of 0.8931, yielding the highest combined score of 0.8474. These results demonstrate that joint segmentation and classification can be effectively performed across multiple institutions using federated training without centralizing patient data.

0.24

MSR-ABC: Complementary Feature Fusion for Clear Cell Renal Cell Carcinoma Classification

cs.CV ·2026-11-06 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
similarity 0.68
Abstract · Submitted to IEEE ISBI 2027

Clear cell renal cell carcinoma (ccRCC) classification from computed tomography (CT) may benefit from representations that capture different aspects of tumour phenotype. However, simply concatenating reconstruction-derived features, image--text embeddings, and radiomic descriptors may not fully exploit their complementary information. We propose MSR-ABC, a global--local framework integrating MedVAE, MedSigLIP, and radiomics. Spatially matched local image descriptors interact through cross-representation attention, while radiomic auxiliary supervision encourages the pooled local representation to retain quantitative tumour attributes. A gated residual mechanism integrates local information with global summaries. Area-aware pooling and visual and soft-text prompting complete the framework. We evaluate discrimination using a patient-level split of 396 KiTS23 cases and an external cohort of 111 TCGA/TCIA cases, reporting mean AUROC over three training seeds with 95% patient-bootstrap confidence intervals. MSR-ABC achieves mean AUROCs of 0.806 internally and 0.879 externally. Internally, it exceeds global MedVAE--radiomics and three-source concatenation by 3.35 and 3.61 AUROC percentage points, respectively. Removing any source lowers mean AUROC in both cohorts, with the largest decreases following radiomics removal. Individual removal of cross-representation attention, auxiliary supervision, or gated fusion also lowers internal mean AUROC. These findings are consistent with complementary contributions within the integrated architecture and support further investigation of structured representation fusion for non-invasive renal tumour characterisation.

0.13

Heterogeneity-Aware Deep Learning for Tumour Classification from Multiparametric MRI

cs.CV ·2026-08-18 ·Yue Xia, Euijoon Ahn, Tian Xia, Yuan Yuan, Michael Fulham +1 more
similarity 0.67
Abstract

Intra-tumoural heterogeneity (ITH) reflects spatial variation in tumour biology and is an important determinant of tumour behaviour, prognosis, and treatment response. Radiomics and deep learning have shown promise for tumour classification from multiparametric MRI (mp-MRI), but radiomics relies on handcrafted features, while most deep learning methods use whole-tumour representations or manually defined sub-regions, limiting scalable modelling of tumour heterogeneity. We propose a Heterogeneity-Aware Deep Learning Classification (HA-DLC) framework that explicitly models imaging-derived tumour sub-regions for lesion-type diagnosis and molecular-status prediction. HA-DLC consists of: (1) a Heterogeneous Sub-region Generation (HSG) module that produces initial pseudo-labelled sub-regions via unsupervised clustering, followed by Cross-Patient Sub-region Alignment (CPSA), which maps cluster-derived regions to a shared label space using soft assignments; and (2) a Dual-Stream Feature Extraction (DSFE) module that integrates local heterogeneity-aware features with global tumour representations. Given the initial clustering masks, CPSA, segmentation, feature extraction, and classification are jointly optimized end-to-end using soft-target segmentation and classification objectives. We evaluate HA-DLC on the LLD-MMRI2023 liver lesion dataset and the RSNA-ASNR-MICCAI 2021 Radiogenomic Brain Tumour dataset. HA-DLC consistently outperforms state-of-the-art radiomics and deep learning baselines, demonstrating the value of cross-patient sub-region alignment and dual-stream heterogeneity modelling for tumour classification from mp-MRI.

0.26

Pathology foundation models for training-free case retrieval in salivary gland tumors

cs.CV ·2026-10-15 ·Maximilian J. Roesel, Niklas Kiermeyer, Philipp Keyl, Frederick Klauschen
similarity 0.67
Abstract

In pathology, pattern recognition relies on a frame of reference built through extensive training and experience, which may still fall short when encountering rare cancer subtypes. Archives of previously diagnosed tumors often contain relevant precedents, yet identifying the most relevant cases remains challenging. Here we explore whether content-based retrieval with current pathology foundation models facilitates rare cancer diagnostics without any task-specific training. Pathologists can query a digitized archive using a region of interest (ROI) from a whole slide image (WSI) and retrieve morphologically similar cases, along with their ICD-O codes and corresponding WSIs. The ROI can be selected manually or automatically using a gated attention-based multiple instance learning model. We evaluate our approach by leave-one-case-out on an imbalanced dataset of 137 salivary gland tumor cases spanning 12 ICD-O morphology categories, comparing four pathology foundation models (Atlas2, Atlas2-B, Atlas2-S, and UNI2h). Top-1/3/5 retrieval was 62.5%/76.7%/81.3% for Atlas2, 50.2/66.6/72.9% for UNI2h, 52.3%/71.5%/77.6% for Atlas2-B and 54.4/65.2/73.7% for Atlas2-S. Macro-averaged F1 ranged from 69.0% for the smallest model Atlas2-S to 76.6% for the largest model Atlas2 across the five classes with at least ten cases. Our modified Chamfer similarity separated correct from incorrect matches among the Top-5 more reliably for Atlas2 (AUC 0.754) than for Atlas2-B (0.679, p = 0.020) and Atlas2-S (0.653, p = 0.003), but not UNI2h (0.697, p = 0.196). Requiring no additional training or manual annotation, this approach makes departmental archives searchable with pathology foundation models, providing a low-barrier route to case-based differential diagnosis and extending the individual frame of reference to the collective experience of the department.

0.17

VGG16-MCA UNet: Whole-Tumor Segmentation in 2D FLAIR MRI with Decoder-Side Channel Attention

eess.IV cs.CV ·2026-09-20 ·Shubham Gajjar, Deep Joshi, Avi Poptani, Vishal Barot
benchmarktheorycode/data similarity 0.67
Abstract · 22 pages, 7 figures, 4 tables. Code and data splits: https://github.com/ShubhamGajjar/vgg16-mca-unet

Automated brain tumor segmentation supports diagnosis, treatment planning, and monitoring of disease progression, but building models that generalize across heterogeneous tumors and limited annotated data remains difficult. We present VGG16-MCA UNet, a hybrid architecture pairing an ImageNet-pretrained VGG16 encoder with a decoder in which a Multi-Channel Attention (MCA) module recalibrates features after each skip-connection fusion, trained with the Focal Tversky loss to counter severe foreground-background imbalance. We evaluate the model as a 2D, FLAIR-only, whole-tumor segmenter on tumor-positive slices from two public datasets: the BraTS 2020 benchmark and the LGG MRI Segmentation dataset. Using 5-fold cross-validation and a single network formed by averaging the weights of the five fold models, the method attains an aggregate pixel-level Dice (F1) of 95.10% on our held-out BraTS 2020 split and 88.32% on LGG. These scores are computed over all test pixels pooled into a single confusion matrix rather than averaged per case, and are therefore not directly comparable to the per-case mean Dice used in the BraTS challenge protocol. All partitions were drawn over individual slices rather than over patients, so every patient contributes slices to both training and test; the figures above therefore measure interpolation within known patients and should be read as an upper bound rather than as generalization to new ones. The model segments a 256x256 slice in 66.32 ms on a single 6 GB NVIDIA RTX 2060, approximately 8 ms more than an equivalent VGG16-UNet without MCA. We release the split records and report the protocol in full, with the aim of providing a precisely specified and reproducible 2D FLAIR baseline.

0.23