CS Paper Radar

Deep learning of longitudinal visual fields predicts glaucoma progression rate and identifies fast progressors

Taiabur Rahman, Siddiqur Rahman, Muhammad Moniruzzaman, Ummay Kawsar, Sayedatunnessa Ratna, Shadman Siddique, Rafsan Siddique, Tausif Ahmad, Tahsin Ahmad, Golam Rabbani

cs.CV cs.AI ·submitted 2026-09-24 08:58 UTC · v1
hot direction

Abstract

Glaucoma is the leading cause of irreversible blindness, and timely identification of fast progressors is essential to prevent disability. Current practice estimates progression by ordinary least-squares regression of mean deviation (MD) on time, requiring 6--10 visual field (VF) tests over several years to obtain a reliable slope. We present GLAM (Glaucoma Longitudinal Analysis Model), a deep learning framework that ingests longitudinal Humphrey 24-2 total deviation sequences with five clinical features and predicts MD and visual field index progression rates using attention-based fusion and aleatoric uncertainty. On the open-access University of Washington Humphrey Visual Field dataset (4,276 patient-eyes), GLAM achieved an MD-rate mean absolute error of 0.139 dB yr$^{-1}$ ($R^2 = 0.927$; 73.5% reduction over a ridge baseline) and an AUC of 0.990 for fast-progressor detection. VF-only deep learning can match multimodal pipelines for progression prognostication using routinely collected perimetry alone.

Closest papers

Nearest neighbours by meaning across the whole index.

Attention-Enhanced Deep Features with Heterogeneous Ensemble Learning for Glaucoma Detection

cs.CV cs.AIcs.LG ·2026-09-06 ·Abdullah Al Shafi, Nishat Sadaf Lira, Abrar Hasan, Kazi Saeed Alam, Swapnil Kundu Argha
published similarity 0.66
Abstract · Accepted and presented at 2026 IEEE International Conference on Biomedical Engineering, Computer and Information Technology for Health (BECI…

Glaucoma is a progressive optic neuropathy characterized by irreversible damage to the optic nerve, making timely diagnosis critical to prevent permanent vision loss. Although deep learning has demonstrated promising performance in automated glaucoma detection, existing approaches often overlook feature refinement, suffer from class imbalance, and rely on individual classifiers that limit prediction robustness. To address these challenges, this paper proposes a hybrid glaucoma detection framework that integrates attention-enhanced deep feature extraction with heterogeneous ensemble learning. Specifically, deep representations are extracted using InceptionV3 and subsequently refined by incorporating the Convolutional Block Attention Module (CBAM) to enhance discriminative retinal features. To improve classification robustness, the extracted features are classified using multiple machine learning models together with Single-Level Ensemble (SLE) and Double-Level Ensemble (DLE) strategies, while SMOTE combined with Tomek Links (SMOTE+TL) is employed to alleviate class imbalance. Furthermore, a systematic comparison of handcrafted, deep, and attention-enhanced deep feature representations is conducted. Experimental evaluation on two public retinal fundus datasets demonstrates that deep feature-based methods consistently outperform handcrafted feature-based methods, while the proposed attention-enhanced framework achieves the best overall performance. Furthermore, Grad-CAM visualizations confirm that the proposed model focuses on clinically relevant retinal regions, providing interpretable evidence on the model's prediction process.

0.23

FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs

cs.CV cs.AI ·2026-09-27 ·David Restrepo, Chenwei Wu, Luis Filipe Nakayama, Miguel L. Martins, Stergios Christodoulidis +2 more
top venuebenchmarkdatasetcode/data similarity 0.65
Abstract · Accepted at NeurIPS 2026, Evaluations & Datasets Track. Interactive benchmark dashboard: https://huggingface.co/spaces/dsrestrepo/FOCUS-Reti…

Progress in AI-based retinal image analysis has accelerated with the adoption of foundation models, yet evaluating their real-world reliability remains challenging. Performance reported on a single dataset does not capture how models behave under dataset shift, across clinical definitions, or for different patient subgroups. This limitation is particularly critical in medical imaging, where robustness, calibration, and fairness are essential for safe deployment. We introduce FOCUS (Foundation Ophthalmic Cross-Dataset Understanding under Shift), a cross-dataset benchmark evaluating retinal fundus models across vision-only encoder models (VM), vision-language dual-encoder models (VLM), and multimodal large language models (MLLM). FOCUS harmonizes binary diabetic retinopathy, referable diabetic retinopathy, and glaucomatous optic neuropathy tasks across ten public datasets spanning diverse geographies, acquisition conditions, and label protocols. The benchmark evaluates models through a unified analysis layer that measures ranking performance, calibration, subgroup disparities, and image-quality robustness. We present a large-scale evaluation covering 532 base configurations and 228 MLLM configurations adapted via LoRA fine-tuning. Results show no model family consistently dominates across tasks and datasets: general VM encoders achieve the strongest average ranking performance, medical MLLMs are competitive but variable, and dual-encoder VLMs benefit substantially from lightweight adaptation. Fine-tuning improves in-domain performance but exhibits heterogeneous transfer to external datasets, particularly in calibration. FOCUS provides a practical framework and public benchmark to assess generalization, reliability, and robustness beyond single-dataset leaderboards.

0.52

Exploring the Latent Structure of AMD Severity Using Retinal Foundation Models

eess.IV cs.CV ·2026-10-09 ·Niccolò Fineschi, Jovana Panic, Atsushi Watanabe, Hideaki Hayashi, Kazuya Nishimura +5 more
published similarity 0.64
Abstract · 7 pages, 5 figures. Accepted for publication at IEEE EMBS BHI 2026

Retinal foundation models have demonstrated strong performance across a wide range of ophthalmic tasks, yet relatively little is known about how disease-related information is represented within their learned embeddings and whether this distribution influences downstream prediction performance. In this work, we use Age-related Macular Degeneration (AMD) as a case study to investigate how disease severity is represented within the embedding space of RET-CLIP, a retinal vision-language foundation model, using bilateral fundus images from the AREDS dataset, benchmarked against non-retinal encoders. We first characterize the distribution of AMD severity within the learned representation space and then evaluate how this structure influences classification performance across three clinically relevant task formulations of increasing granularity. Finally, we analyze the most influential latent dimensions combining feature attribution, statistical phenotype association, and qualitative image analyses. Our results show that RET-CLIP represents AMD severity as a continuous spectrum rather than a set of discrete categories, with healthy and advanced disease stages exhibiting clearer separation than intermediate ones. This organization was reflected in downstream performance, which decreased from a balanced accuracy of 0.844 and 0.814 for binary AMD and Late-AMD detection respectively to 0.446 for six-class grading. Furthermore, the most influential latent dimensions were statistically associated to distinct retinal phenotypes, including drusen accumulation, pigmentary alterations, and advanced retinal lesions. These findings suggest that the structure of retinal foundation-model representations influences the difficulty of clinically relevant prediction tasks and demonstrate the potential of representation-level analysis for understanding disease organization and improving interpretability.

0.18

Detecting Glaucoma Across Multi-ethnic Myopic and Non-Myopic Populations Using an Uncertainty-Aware Vision Transformer: A Multicentre Model Development and Validation Study

cs.CV cs.AI ·2026-09-24 ·Raghavan Lavanya, Yangqin Feng, Ten Cheer Quek, Quan V. Hoang, Linda Yi-Chieh Poon +34 more
similarity 0.64
Abstract

Background: Artificial intelligence (AI)-based glaucoma detection from colour fundus photographs (CFP) offers scalable screening, but performance may decline on external datasets because of differences in ground-truth definitions, populations, and coexisting conditions such as high myopia (HM). We developed and validated a Vision Transformer-based deep learning (DL) model for glaucoma detection across multi-ethnic cohorts with and without HM. Methods: A ViT-B/16 model with predictive uncertainty estimation was developed using 56,483 CFPs (57.1% with myopia; 14.4% with HM). Glaucoma labels were standardised using clinical, imaging, and perimetry data. The model was validated on 16 independent datasets across three continents, including four datasets with explicit HM labels. Findings: Internal AUROC was 98.7% (95% CI 98.2-99.1%), with sensitivity 94.5% and specificity 97.3%. Across 16 external datasets from eight countries, AUROCs ranged from 86.4% to 99.6%. In HM eyes, internal AUROC was 97.8% (95% CI 96.1-99.2%), with sensitivity 94.8% and specificity 93.7%. External HM AUROCs were 86.5% in the Beijing Eye Study and 93.3%, 91.8%, and 85.5% in hospital-based datasets from Taiwan, Thailand, and South Korea. In an exploratory HM clinical evaluation, the model had higher CFP-only diagnostic accuracy than ophthalmologists and trained graders (92.0% vs 70.0%; p=0.008) and performed comparably to glaucoma specialists using full clinical information. Interpretation: The model showed robust glaucoma detection across myopic and non-myopic multi-ethnic populations and may support AI-assisted screening in settings with high HM prevalence.

0.28

Deep Learning for Longitudinal Medical Imaging: A Scoping Review

eess.IV cs.AIcs.CV ·2026-09-29 ·Francesca Mussa, Divyanshu Tak, Atlas H. Avval, Sarah Brueningk, Ray H. Mak +3 more
similarity 0.63
Abstract

Longitudinal medical imaging analysis is a cornerstone of modern medical practice and patient care. Deep learning applied to longitudinal imaging offers wide potential to enhance diagnosis and track disease progression by capturing spatial changes over time. With major advances in single-timepoint deep learning for imaging, there has been growing interest in longitudinal image analysis, given its increased clinical relevance, though technical challenges remain. Several recent innovations may lead to a new era of multi-timepoint image evaluation, yet the scientific landscape, recent progress, and areas of need remain under-characterized. To address this gap, we conducted a scoping review of deep learning methodologies applied to longitudinal medical imaging, yielding 102 studies published between 2018 and 2025. Neurological disorders (48%) and ophthalmic conditions (12%) were the most common clinical applications, with MRI serving as the predominant imaging modality (67%). Sequential feature modeling approaches combining convolutional neural networks (CNNs) with temporal models (LSTM/RNN) were the most frequent methodology (40%), followed by direct feature aggregation across timepoints (23%). Most studies targeted classification tasks (56%), while external validation was performed in only 24% of studies. Our findings highlight that deep learning-based longitudinal imaging analysis remains a promising field, though newer temporal architectures and larger datasets may improve success and clinical adoption of these tools.

0.36

OptiModNet: A UNet-Transformer Hybrid with Grouped-Query and Channel Attention for Optic Disc and Cup Segmentation

cs.CV cs.AI ·2026-08-19 ·Soumili Ghosh, Debapriya Roy, Aryan Das, Bikash Santra
code/data similarity 0.63
Abstract

Precise segmentation of the optic disc and cup is critical for the early detection and diagnosis of glaucoma. However, achieving consistently high performance across datasets while maintaining low computational requirements remains a significant challenge. In glaucoma detection, low-computation methods are crucial for enabling rapid, large-scale screening and facilitating deployment in resource-limited clinical environments. While deep learning models such as UNets, Vision Transformers (ViTs), and Diffusion models have demonstrated strong segmentation performance but these methods often come with substantial computational overhead. UNets are efficient at capturing local features but are limited in modeling global contextual information. Conversely, ViTs excel at long-range dependency modeling but are computationally intensive. Hybrid architectures, such as UNetR, which combine transformer-based encoders with UNet-style decoders, have shown improved performance but while incurring additional complexity. Considering these, in this work, we propose OptiModNet, a light weight novel hybrid architecture tailored for optic disc and cup segmentation. The model integrates diverse attention mechanisms at multiple stages of the network to enhance both local and global feature representation. We include an Aggregated Pyramid Loss that supervises predictions at multiple decoder depths, to promote better gradient flow and structural consistency. We evaluate OptiModNet on the REFUGE2 dataset for both optic disc and cup segmentation tasks. Our method achieves state-of-the-art performance, exceeding existing approaches by over 2.5\%, while maintaining high efficiency with only 3.73 GFLOPs and 1.93M parameters. The code is available at https://github.com/SG1947/OptiModNet.

0.24

Beyond Accuracy: Benchmarking Uncertainty Quantification in Retinal Disease Screening

eess.IV ·2026-11-17 ·Mahvash Jebeli, Mohammad Eslami, Nazlee Zebardast, Lucia Sobrin, Tobias Elze
benchmarkdataset similarity 0.62
Abstract

Reliable uncertainty quantification (UQ) is essential for evaluating retinal AI systems beyond classification accuracy, yet it remains unclear whether existing UQ strategies generalize across diseases, model architectures, and reliability criteria. We introduce a large-scale, multi-disease benchmark comprising over $242,000$ fundus photographs from $32$ datasets covering diabetic retinopathy, age-related macular degeneration, and glaucoma. We evaluate six representative UQ strategies across three Vision Transformer configurations, assessing discrimination, probabilistic calibration, selective prediction, and conformal prediction-set coverage. Our findings reveal no universally superior model or UQ strategy: methods that improve reliability in one disease or architecture may underperform in another, while improvements in discrimination, calibration, and selective prediction do not necessarily align. Notably, computationally intensive methods do not consistently outperform simple confidence scores, and domain-specific foundation models and calibration-oriented loss functions do not guarantee greater reliability. In contrast, conformal prediction provides a complementary framework for achieving near-nominal marginal prediction-set coverage across diverse settings, subject to its statistical assumptions. These findings challenge universal UQ recommendations and highlight the need for disease-specific, model-specific, and multidimensional reliability evaluation before clinical deployment. We release standardized dataset splits, trained checkpoints, evaluation code, and an interactive research demonstration to support reproducible benchmarking.

0.06

Augmentation Strategy for DINO in Glaucoma Classification

cs.CV ·2026-10-23 ·Ashish Kumar Meena, Chandra Sekhar Seelamantula
publishedbenchmarkcode/data similarity 0.62
Abstract · 11 pages, 3 figures. Accepted at the 17th International Workshop on Machine Learning in Medical Imaging (MLMI 2026), held in conjunction wit…

Self-supervised learning (SSL) offers a promising approach to medical image representation learning, yet augmentation strategies of SSL frameworks validated on natural images do not reliably transfer to specialized medical imaging domains. We analyze DINO, a knowledge-distillation based SSL framework, and empirically demonstrate that its default augmentation strategy produces unreliable representations for retinal fundus images, degrading downstream glaucoma classification performance. Guided by the principle that effective cropped views should share minimal redundant information while retaining clinically relevant signal, we redesign DINO's augmentation strategy. Our approach biases the learned representations toward diagnostically critical features rather than low-level image statistics. We evaluate our method for glaucoma classification by training a linear classifier on the frozen representations, achieving strong generalization across seven benchmark datasets. URL for code and weights: https://github.com/ashish-256/task_dino

0.43