CS Paper Radar

SkinAgent AI: A Safety-Grounded Multimodal Agentic Framework for Non-Diagnostic Skincare Support

Muhammad Muhtasim Shahriar, Abdullah Mohammad Sayem, Tze Hui Liew, M. F. Mridha, Md. Mahiuddin

cs.AI ·submitted 2026-09-24 10:15 UTC · v1
benchmark

Abstract

Consumer-facing skincare AI must coordinate visual evidence, product information, tool use, and user-facing actions within explicit evidence and safety boundaries. This study evaluates SkinAgent AI, a non-diagnostic multimodal framework that combines visual concern routing with grounded and auditable LLM-based orchestration. The architecture includes routing for Acne, Pores, and Wrinkles; photograph-based skin-type estimation; count-informed ordinal acne-severity support; typed tools; database-grounded recommendation and action functions; deterministic safety, privacy, and evidence checks; approval before state-changing actions; and structured trace and replay mechanisms. Visual-model performance and system-level agent behavior were evaluated separately. Across three seeds, the skin-condition routing model achieved 99.84% +/- 0.07% accuracy. Skin-type estimation achieved 88.85% accuracy, while count-informed acne-severity support achieved 84.59% accuracy with a quadratic weighted kappa of 0.9076. On a locked but non-independent 240-case system benchmark, intent accuracy was 80.00%, exact tool-set match was 62.92%, and strict task completion was 47.08%. No violations or successful cross-user leakage events were observed in the finite safety and privacy test suites. Tool-selection errors, incomplete grounding of product attributes, and unreliable failure fallback nevertheless remained. These findings support the feasibility of bounded, database-grounded, and traceable agent orchestration for non-diagnostic skincare assistance. They do not establish clinical readiness, external generalization, formal privacy guarantees, or universal safety. Independent validation, expert assessment, robustness and fairness testing, and prospective evaluation in real-world settings remain necessary.

Comment
Submitted to JMIR AI and currently under peer review

Closest papers

Nearest neighbours by meaning across the whole index.

Benchmarking Off-the-Shelf Multimodal AI Models Against Dermatologists on Patient-Captured Skin Images

cs.CV ·2026-09-21 ·Rian Dolphin, Laura Knowles
similarity 0.63
Abstract · 14 pages, 6 figures

Artificial intelligence (AI) has advanced at a rapid pace in recent years. Initially, breakthroughs in large language models caught widespread attention. However, recent generations of frontier AI models have adopted multimodal capabilities as a first class citizen, with vision capabilities being central to that. In this paper, we evaluate three recently released models on the task of diagnosing dermatological conditions from patient-submitted images. The models chosen are at the low to mid tier in terms of pricing and thus represent a floor on current AI capabilities, not a ceiling. We evaluate AI performance relative to a panel of three certified dermatologists, who grade each image, and we present four interesting findings. Firstly, depending on the metric, the tested AI models are either on par or slightly trail humans in terms of inter-clinician agreement. Secondly, we find that asking AI models for a confidence rating produces poorly calibrated answers, meaning use of confidence thresholds should not be relied upon in a clinical setting. Thirdly, the effect of providing additional patient metadata is strongly model-specific, with one of the three models degrading on every metric considered. Finally, model cost is not predictive of performance. The best-performing model we tested costs on average $0.0045 per case.

0.21

Multi-Dataset Diagnostic Utility of Clinical Visual Concepts in AI Systems for Dermatology

cs.CV ·2026-10-06 ·Linda Wermelinger, Simone Lionetti, Fabian Gröger, Nipun Ranasekara, Philippe Gottfrois +4 more
publisheddatasetcode/data similarity 0.58
Abstract · Accepted at the MICCAI ISIC Workshop 2026. 11 pages, 3 figures, 3 tables. Code and dataset: https://github.com/Digital-Dermatology/SkinLex

The clinical integration of AI systems in digital dermatology relies heavily on human trust. Clinically interpretable visual concepts can act as intermediate representations enhancing trust and reliability. However, research in this domain is currently limited by scattered, heterogeneous dataset annotations. In this work, we introduce SkinLex, a harmonized dataset of 48 clinical morphological attributes across four public datasets (SkinCon, DermaCon-IN, MM-Skin, and PASSION) for a total of 20,411 records. Supervised nine-partition classification of skin conditions shows that limiting features to specific visual groups, like shapes or colors alone, reduces diagnostic accuracy. Bootstrapped backward elimination reveals that the set of 48 visual concepts has some degree of redundancy for algorithmic nine-partition diagnosis on the examined dataset. This demonstrates that coarse diagnosis on the selected dataset requires a relatively small but varied combination of clinical concepts, and motivates further research to improve concept taxonomy. Results can be translated into clinical benefits by reducing inputs for concept-based models, improving efficiency for annotation and modeling, and further enhancing interpretability. Code and prompt templates are available at https://github.com/Digital-Dermatology/SkinLex.

0.41

CAMEO: A Class-Activation-Mapped Equitable Overlay Framework for Fair and Robust Deep Learning-based Skin Condition Diagnosis

eess.IV cs.CVcs.LG ·2026-09-28 ·Youssef Attia, Debasmita Mukherjee
similarity 0.57
Abstract · 21 pages, 9 figures

Deep learning classifiers for dermoscopic skin lesions often reach high in-distribution accuracy while quietly relying on spurious background cues such as skin tone, device vignetting, and embedded rulers, rather than on lesion morphology. This undermines robustness and fairness across skin tones. This work asks whether Explainable AI (XAI), typically used only to audit a finished model, can instead be repurposed as an active training signal that corrects this shortcut without sacrificing diagnostic accuracy. We introduce CAMEO (Class Activation Mapped Equitable Overlay), a framework that improves skin-lesion classification by selecting stable model explanations and using them to separate lesions from their backgrounds. It then replaces the background with realistic synthetic skin while keeping the lesion unchanged. On HAM10000 and dark-skin ISIC images, CAMEO maintained accuracy while reducing background-driven errors by nearly four times. It also made the model's attention more consistent when backgrounds changed. Results across multiple tests show that reducing reliance on background information improves robustness, with Fitzpatrick-based backgrounds providing a realistic and interpretable approach. Results show that XAI-guided augmentation can make dermoscopic classifiers measurably more robust and fair at no cost to accuracy. They also clarify that it is the mechanism and not the specific tone palette that matters, and that the lasting contribution of XAI here lies in stability-screened, annotation-free lesion localisation rather than in the robustness number itself.

0.12

SkinMind: Equipping Agentic RAG with Human-Inspired Graph Probing for Reliable Dermatology AI

cs.IR ·2026-11-06 ·Jing Hao, Weinan Zhou, Zhihong Lu, Yaling Shen, Yiming Xu +9 more
similarity 0.55
Abstract · 35 pages, 7 figures

Reliable dermatology AI requires access to verifiable evidence distributed across heterogeneous textual and visual sources. However, conventional retrieval-augmented generation (RAG) typically relies on one-shot retrieval from flat corpora, limiting its ability to adapt retrieval granularity, explore multi-hop relations, and integrate multimodal clinical evidence. We introduce SkinMind, a multimodal agentic RAG framework that equips policy models with human-inspired graph probing for autonomous evidence seeking. SkinMind organizes retrieval as an iterative interaction between an orchestrator and a graph environment. Through eight hierarchical graph-probing tools, the orchestrator progressively identifies relevant entities, inspects node-level information, traverses relations and paths, and retrieves source-text and visual evidence. This progressive-disclosure design allows the model to adaptively determine the retrieval modality, exploration direction, and evidence granularity while constructing a query-specific evidence subgraph. To support autonomous graph probing, we construct SkinMind-KG from a 62M-token corpus of dermatology guidelines and textbooks and 423K images, guided by a dermatologist-informed schema and a conflict-resolution mechanism. The resulting graph contains over 1.0M nodes and 2.0M edges, unifying textual, relational, and visual evidence for retrieval. Across six dermatology VQA benchmarks and two policy-model settings, SkinMind improves the average score over direct answering by 8.70 and 8.89 points with GPT-5.4-mini and Gemini-2.5-Flash, respectively, while consistently outperforming competing RAG methods. Together, SkinMind and SkinMind-KG provide an effective foundation for evidence-grounded multimodal reasoning in dermatology.

0.42

CG-HAF: An Interpretable Global-Local Lesion-Burden Fusion Framework for Ordinal Acne Severity Grading in Agentic Skincare Support

cs.CV cs.AI ·2026-09-25 ·Muhammad Muhtasim Shahriar, Md. Naimur Asif Borno, Saad Aloteibi, Mohammad Ali Moni
benchmark similarity 0.55
Abstract · Manuscript under review at Expert Systems with Applications

Ordinal acne severity grading requires distinguishing visually similar neighboring grades while jointly weighing holistic facial appearance and localized lesion burden - evidence that most existing approaches collapse into a single opaque representation. We introduce CG-HAF, a global-local fusion framework that instead keeps this evidence explicit: averaged holistic severity probabilities from independently trained classifiers are combined with structured lesion-burden descriptors from an object detector (lesion count, detection confidence, lesion area) into a compact representation, from which a lightweight, interpretable classifier produces the final grade. On a widely used benchmark, this fusion yields a clear, statistically supported improvement over global-evidence-only baselines, with the largest gains on the most severe cases. Testing on an independent dataset with a different grading standard shows that strong within-dataset performance does not transfer automatically, and a follow-up diagnostic attributes much of this gap to mismatched grading criteria rather than detection failure alone. These findings support interpretable global-local fusion as an effective strategy for ordinal acne grading while highlighting criterion alignment as key to cross-dataset portability, with a further illustration of how the resulting severity signal can support transparent, non-diagnostic decision-making in skincare applications.

0.27

SkinAdvisor: An AI-Driven Decision Framework for Skin Production Planning via Multi-Modal Transformer Sales Forecasting

cs.LG cs.AI ·2026-11-11 ·Ge Fan, Kai Wang, Chaoyun Zhang, Yingjie Li, Yuze Liu +1 more
top venue similarity 0.54
Abstract · Accepted to AAAI 2027 (IAAI-27). 10 pages, 4 figures

Skins, cosmetic in-game items, are a primary revenue stream for modern online games, yet production decisions (which skins to make, when to release, how to price) remain driven by intuition and retrospective analytics. We present SkinAdvisor, an AI-driven decision framework for skin production planning, powered by SkinCast, a deployed multi-modal Transformer forecasting 180-day per-day sales trajectories for unreleased skins. SkinCast couples four encoders: a pretrained Informer for player-preference time series, a pretrained Player-Hero-Skin graph embedder for relational priors, and two lightweight Transformers for skin attributes and release context, fused through a shared backbone with a local-plus-global day-x positional encoding and decoded by an N-layer Informer in a single non-autoregressive pass. SkinAdvisor plugs these forecasts into a serving pipeline (Select -> Fill -> Infer -> Sales -> ROI -> Ranking) that ranks candidate skins by forecast-based ROI and supports multi-candidate comparison. The system has been in production for a full release cycle. Offline experiments show SkinCast reduces RMSE by ~20% over the strongest baseline (Informer) and ~60% over classical methods; stress tests on a 16-core CPU server confirm p99 latency under 8ms and peak throughput above 1100 rps. We report two deployment lessons: order-of-magnitude accuracy suffices for production decisions, and pretrained embeddings can leak temporal information, requiring season-based splitting to prevent.

0.45

Disease Burden over Skin Tone: Decomposing the Dermatology-AI Generalization Gap

cs.CV cs.AIcs.LG ·2026-09-02 ·Nirajan Kunwor, Sanjaya Poudel, Quoc-Huy Trinh, Jahidul Arafat, Sunil Kumar Gaire
similarity 0.53
Abstract

Dermatology artificial intelligence (AI) models are predominantly trained on light-skinned, cancer-focused image collections, yet they are increasingly proposed for deployment in resource-constrained settings where patients differ from training populations along two confounded axes: skin tone and disease distribution. We investigate whether poor generalization is primarily caused by skin-tone underrepresentation or disease-distribution shift. We evaluate a cancer-trained baseline (ResNet-50 fine-tuned on HAM10000 and ISIC 2019), two dermatology foundation models (DermLIP and MONET), and a general-purpose vision model (DINOv3) as frozen feature extractors. Models are evaluated on a tone-stratified disease-matched dataset (Diverse Dermatology Images, DDI) and a disease-shifted tone-diverse dataset (Skin Condition Image Network, SCIN). Our results show that disease-distribution shift contributes more than skin tone in the evaluated settings. The cancer baseline decreases from 0.62 to 0.21 balanced accuracy when transferred to unfamiliar clinical conditions, while the within-disease skin-tone gap is smaller (0.10-0.18) and inconsistent. Label-free representation analysis shows that this failure reflects a representational limitation rather than only missing output labels: cancer-specialized features poorly cluster unfamiliar conditions (kNN purity lift +0.06 over chance), whereas dermatology-pretrained features retain stronger transferable structure (+0.23). Finally, we show that representation quality predicts recoverable performance under lightweight adaptation. Starting from dermatology foundation models, approximately ten labeled examples per clinical category recover most attainable performance. We release the evaluation protocol and code to support reproducible auditing of dermatology AI generalization.

0.18

ADeptS-Bench: Measuring the Trustworthiness of Computer Use Agents Across Devices

cs.CR cs.AIcs.SE ·2026-08-25 ·Joy Chen, Alejandro Castillejo Munoz, Pierluca D'Oro, Yuxuan Sun, Chloe Evans +1 more
benchmark similarity 0.53
Abstract

Computer Use Agents (CUAs) are increasingly deployed to navigate mobile and desktop applications on behalf of users, yet no benchmark comprehensively evaluates whether they can safely interact with visual interfaces while handling ambiguous instructions. We introduce ADeptS-Bench, a dual-stream trustworthiness benchmark, grounded in the ADEPTS capability framework and general population user studies. The Safety stream provides paired benign/malicious tasks with threats embedded in the visual interface. The Disambiguation stream evaluates whether agents seek clarification when intent is ambiguous. Evaluating seven models reveals that no model consistently exceeds 80% task success while staying below 30% attack success; every model clicks "Checkout" on a $25K order without hesitation, and none detects that a "factory reset" button is mislabeled as "Optimize." An ablation reveals three distinct safety architectures: tool-dependent (ASR +21-23pp without refusal tool), partially tool-dependent (+10-11pp), and no mechanism (unchanged). In disambiguation, all models overestimate consequence severity, mirroring the over-refusal bias observed in safety. We release all data, evaluation code, and analysis tools upon publication.

0.26