CS Paper Radar

When 10,000 Windows Are Not 10,000 Tests: Auditing Statistical Confidence in Sliding-Window Time-Series Classification

Xinze Shi, Litian Zhang, Binrui Shi

cs.LG ·submitted 2026-09-25 02:49 UTC · v1
published

Abstract

Sliding-window classifiers are often evaluated on thousands of overlapping test windows, even though neighboring predictions share observations and remain nested within recordings and subjects. Subject-disjoint evaluation prevents one form of leakage but does not make those test windows independent. We present a practical audit that maps three claims - performance on observed recordings, future recordings from observed subjects, and unseen subjects - to explicit aggregation rules and established dependence-robust inference. At 75% overlap, controlled simulations give 16.9% Type-I error for IID observed-record inference and 7.2% for session-centered Bartlett-HAC: a substantial improvement with residual miscalibration. Audits of frozen WISDM and HARTH predictions show that nearly fourfold growth in test rows yields only 1.75-1.94-fold variance-equivalent information growth. At that overlap, fixed-record paired Accuracy-difference intervals are 1.22-1.66 times the IID widths; this inflation is not universal at zero overlap. On HARTH, paired Accuracy-difference intervals include zero across three overlap settings, whereas Macro-F1 favors MiniROCKET. Independent recomputation, common-session checks, class-level results, and separately seeded calibration make the audit's scope and limitations inspectable. The resulting workflow distinguishes additional predictions from additional independent evidence.

Comment
8 pages, 6 figures, 6 tables. Accepted at the 38th IEEE International Conference on Tools with Artificial Intelligence (ICTAI 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Finite Audits of Model Updating: Coverage and Resolution of Paired Disparity Comparisons

cs.LG ·2026-09-09 ·Aaron Ceross
unusual similarity 0.63
Abstract · 113 pages, 9 figures, 68 tables; supporting material included. Retitled and substantially revised to focus on finite-audit inference for pai…

Finite audits can become more precise and decisive without reliably covering the change in subgroup disparity. We study the updating-minus-frozen difference in absolute subgroup gaps, averaged over a fixed history, for true-positive and false-positive rates separately. Controlled paired-count experiments and independent audits of retained model histories distinguish interval coverage, erroneous conclusions and decision resolution. With a zero frozen gap and a five-percentage-point updating gap, bootstrap coverage is 12.0%; a numerical-delta alternative improves coverage to 52.9%, still far below the nominal 95%, with 500 smaller-group and 2,000 other-group observations of the specified outcome per window over ten windows. Unequal absolute-gap biases explain point-estimate displacement, and gap direction changes pairing's variance contribution. Prior strength materially affects sparse, off-centre comparisons. In the retained panel, relatively high mean coverage coexists with substantial undercoverage for individual histories, while larger audits can considerably improve resolution. Conservative projection provides conditional coverage under the sampling assumptions but often leaves comparisons unresolved. These findings show why interval width and conclusive margin decisions cannot, by themselves, establish the reliability of an estimated disparity change.

0.33

When Temporal Perturbations Act Like Sensor Biases: Label-Free Auditing of Wearable Activity Recognizers

cs.LG cs.AIcs.CR ·2026-09-24 ·Qingyu Wu, Yuan Wei, Renju Liu, Hua Cheng
similarity 0.57
Abstract

Wearable human-activity recognition (HAR) models operate across sensors, subjects, and backbones, yet a smooth waveform may appear temporal while exploiting a persistent sensor offset primarily. We introduce SpectrumAudit, a label-sealed audit that fits a phase-randomized full-window stimulus on calibration windows from subjects held out from training and testing. After selection, it replays its exact DC projection and budget-constrained zero-mean residual on the same frozen victim without refitting. Across 27 victims from three datasets and three backbones, the selected waveforms cause 2.87-40.83-point three-phase robust accuracy losses. Under this replay budget, DC is more damaging than AC on 24/27 victims and recovers at least 90% of the full drop on 22/27; all 5 failures occur on WISDM. In a held-out UTD-MHAD check, the selected waveform causes 13.49-pp accuracy and 11.68-pp macro-F1 losses, versus -0.66 pp for matched random changes. The audit diagnoses offset versus zero-mean variation under a common peak-budget cap. The code will be released upon acceptance.

0.34

Excess Separability: Nuisance-Controlled Residual-Stream Probing for Benchmark Contamination Detection

cs.CL cs.LG ·2026-08-12 ·Florian Braun
benchmarkcode/data similarity 0.57
Abstract · 23 pages, 11 figures, 8 tables. v2: measures the placebo baseline's own sampling variance, finds it exceeds the permutation null's in every …

Benchmark contamination is diagnosed with n-gram overlap, likelihood-based membership inference, or canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or foresight at release. A recent alternative reads it off a linear probe on internal activations. We show the natural way to do this does not work, specify one that survives measurement, then find that the correction making it work carries more variance than the null it is tested against. The protocol reports a zero-sum contrast on the depth profile of probe accuracy, recentred on a level-matched placebo baseline, tested against a label-permutation null, with the reference set twice the size of the suspect set. Each choice replaces a simpler alternative we rejected on measurement. Reporting the level of excess separability rather than its shape makes the false positive rate track the size of the analyst's own control set, 0.03 to 0.99 under a true null. Contrasting against a flat depth profile rejects a true null 0.72 of the time when surface decodability rises with depth, and loses all power when it falls. On real transformers the protocol fails a test the simulations did not pose. The recentring subtracts an estimate, and the permutation null holds it fixed. Re-estimated across split seeds on four audits of contaminated checkpoints, its standard deviation is 1.30 to 1.56 times the null's own in every arm: what is subtracted to remove a bias is more variable than what it corrects. The one nominally significant result, p = 0.0075, becomes 0.0745 once that variance is propagated, and no verdict is issued. The simulations missed this because their surface key is the covariate driving item variation; on real text it is a proxy, and degrading key quality in simulation reproduces it. We add a companion measurement and a widened null. No arm shows contamination.

0.60

Will the Judge Flip? Predicting Position-Sensitive LLM Judgments from Residual Stream Activations

cs.LG cs.AI ·2026-10-05 ·Hashmath Shaik, Gnaneswar Villuri, Alex Doboli
similarity 0.57
Abstract · It was submitted to neurips workshop (JUDGE workshop) and received a review score 6.5 combined with one strong accept and one above threshol…

The order in which candidate responses are presented can change an LLM judge's verdict. Detecting such a position flip ordinarily requires judging each pair in both orders, which doubles the number of judgments. We investigate whether residual stream activations recorded immediately before the initial verdict can predict a flip. We use nested grouped cross-validation to evaluate regularized linear probes on 534 JudgeBench pairs for three Qwen3 judges and Llama-3.1-8B. The linear probes achieve AUROCs of .621-.850 and outperform a combined baseline that uses verbalized confidence, verdict-label logits, response lengths, and the judge's initial choice by .062-.113 AUROC. Linear probes trained on JudgeBench and then frozen achieve AUROCs of .685-.853 on 1,802 MT-Bench comparisons without MT-Bench fitting or recalibration. These results show that pre-verdict activations support prediction of susceptibility to candidate order and outperform the non-activation predictors evaluated here.

0.08

Readout and Operating-Point Sensitivity in Event-Stream Candidate Selection

cs.CV ·2026-10-27 ·Yifan Shuai
similarity 0.57
Abstract · 12 pages, 4 figures, including supplementary material

Event-triggered recording needs a useful combination of target capture and false triggers, yet representation comparisons can change with readout and threshold calibration. We evaluate real event accumulations from 520 DailyDVS-200 clips and 47 participants using participant-disjoint training, validation, and testing. The original study varies frozen encoder scale, accumulation duration, and temporal view count; a post-review extension adds two supervised-pretrained convolutional encoders, a 61,586-parameter trained CNN with three seeds, ten repeated participant partitions, and calibration sensitivity. At 50 ms/eight views under the primary handshake-or-fall policy, DINO-S CLS captures 101/132 targets with 40/388 false triggers, versus 78/132 and 35/388 for patch mean. DINO-B CLS has lower selected-threshold capture but higher fold-wise low-FPR partial AUC (0.746 versus 0.732). MobileNetV3-Small captures 97/132 with 53/388 false triggers, demonstrating why lightweight baselines and actual operating points matter. Across ten dependent repartitions, mean normalized partial AUC is 0.738 for DINO-B CLS and 0.674 for MobileNet. The original LeJEPA S-to-B capture difference is 8.3 points, but its multiplicity-adjusted interval includes zero. Duration and view-count effects remain policy dependent. We find no established JEPA-specific advantage. The evidence concerns offline action-defined candidate selection on previously used development data; it does not establish personal recording value, continuous false alarms per hour, or eyewear energy.

0.57

Repeated-Measure Leakage, Distribution Shift, and Reliability under Partial Observation in Patient World Models

cs.LG ·2026-10-03 ·Arjun Subramanian
publishedcode/data similarity 0.56
Abstract · 13 pages, 7 figures. Selected for oral presentation at the NeurIPS 2026 Workshop on World Models for High-Stakes Health (WMHS) Replication P…

Patient world models are increasingly proposed for longitudinal prediction, intervention-aware reasoning, and clinical-trial simulation. Causal or clinical intervention validity is distinct from predictive generalization and reliability; before making stronger claims, the underlying predictive state should generalize across patients, survive realistic shifts and missing observations, and expose failure through meaningful reliability signals. We evaluate these prerequisites in a deliberately narrow setting: short-horizon digital-biomarker forecasting from PhysioNet GaitPDB, comprising 165 participants, 306 recordings, and 51,129 context-future pairs. Using persistence, ridge, MLP, GRU, Transformer, and a compact JEPA-style predictor, we build an evaluation ladder that progressively removes raw temporal overlap, same-recording familiarity, and same-patient familiarity before testing unseen-patient generalization. For GRU, NMSE rises from 0.1227 under random-window splitting to 0.1393 after eliminating raw train-test overlap and to 0.1961 under patient holdout. Among 54 participants with repeated recordings, exposure to a different recording from the same patient improves GRU NMSE from 0.2177 to 0.1556, while a recording-excluded identity hypothesis is not supported at the participant level. Under participant-held-out evaluation, MLP and Transformer are statistically indistinguishable. Study shift, a four-times-longer prediction gap, and partial observation further degrade performance; under 50% temporal masking, Transformer NMSE rises to 0.611 while MC-dropout predictive variance falls. We do not claim a longitudinal or intervention-aware simulator. Instead, the results support a prerequisite evaluation stack of patient separation, repeated-measure controls, shift, missingness, and uncertainty validation before stronger patient-world-model claims are trusted.

0.39

How to Run Statistics over LLM Judges and Trust the Results: Calibrated Inference for Small-Sample AI Evaluation with evalstats

cs.CL cs.AIcs.HCstat.ME ·2026-09-20 ·Ian Arawjo
code/data similarity 0.56
Abstract · 39 pages, 20 figures

Researchers across academia increasingly base significance claims on LLM judge scores and small-sample AI evaluations. Yet without well-calibrated confidence intervals (CIs), hypothesis tests, and judge-bias corrections, such claims are unreliable. We address these issues in several contributions. First, we find that running statistics over raw LLM judge scores leads to inflated false positives: counterintuitively, for many inter-rater agreement metrics, false positive risk peaks at "almost perfect" human-LLM agreement. To help researchers understand how to run statistics over LLM judges responsibly, we present guidance and tooling for the statistical analysis of mixed human-AI judge designs, and implement nine hypothesis tests via prediction-powered inference (PPI), including the first known PPI corrections for four rank-based tests (Wilcoxon signed-rank, Mann-Whitney U, and omnibus variants). To keep PPI++ stable with small human-labeled calibration sets, we introduce bootstrap-adaptive power tuning, which shrinks the estimated weight toward a target estimated from the labeled data, and accounts for that weight's own sampling variance. Second, through Monte Carlo simulations, we derive recommendations for what CI, p-value, and FWER correction methods to use for small-sample AI evaluations (N<100), and warn researchers against bootstrap CIs. We package these recommendations into evalstats, an open-source Python package that selects calibrated methods automatically, and demonstrate it in three scenarios, including one where a real LLM judge validated at "substantial agreement" would have led a researcher to publish a spurious finding. evalstats is publicly available at https://github.com/ianarawjo/evalstats.

0.43

When Repeated Measurements Hurt Tabular Foundation Models

cs.LG stat.ML ·2026-10-12 ·Yixiang Liu, Ruizhe Deng, Bibhas Chakraborty, Qiong Zhang, Yan Shuo Tan
code/data similarity 0.55
Abstract · 44 pages, 12 figures

Tabular foundation models (TFMs) achieve state-of-the-art performance on IID benchmarks, but how do they respond to repeated measurements at the same inputs? Across six TFMs, synthetic and semi-synthetic experiments show that additional measurements can improve predictions at measured inputs while degrading them elsewhere. Harm is most frequent at low noise, and irrelevant features amplify it in several models; real repeated-measurement datasets show similar patterns. Statistically, the IID rule targeted by PFN pretraining treats each repeated input as fresh evidence about the input distribution. When the prior links this distribution to the response function, the resulting protocol mismatch can outweigh the benefit of additional measurements, even under exact inference. Computationally, interventions identify row-count dependence in TabPFN-v3's attention scaling as a contributor to harm. Resetting the count largely reverses distortion in a noiseless linear diagnostic and attenuates amplification by irrelevant features. Finally, we evaluate ways to retain the benefits of repeated measurements while limiting their harm. Averaging measurements usually outperforms supplying them separately at larger repetition counts, whereas count reset can suppress both harm and useful gains. Code, saved results and reproduction instructions are available at https://github.com/drizmiz/PFN-Repeated-Measurement-Supp

0.30