Abstract

Vision-language models (VLMs) achieve strong zero-shot (ZS) classification on histology images but do not perform as well on cytology, whose stains and cell morphology differ markedly compared to histology. Conditional random fields (CRFs) can refine noisy VLM predictions by propagating information across patches, but existing CRF frameworks were designed for histopathology and do not transfer to cytology datasets, released as independent patch pools spanning multiple staining protocols. We introduce CytoCRF, which adapts the pairwise terms to cytology by targeting chromatin and cytology-specific staining, and further enrich the neighborhood of each potential term by combining multiple backbones. Across ten cytology datasets, CytoCRF outperforms existing CRF frameworks at every annotation budget, reaching +13.6 percentage points over the best baseline and +33.7 over ZS with only 50 annotations. Combining information from multiple backbones brings further gains, showing that the neighborhood topology matters more than the pairwise potential computed over it.

Comment
5 pages, 2 figures

Closest papers

Nearest neighbours by meaning across the whole index.

CytoSPM: Open-Vocabulary Cytopathology Detection with Structured Prompt Bank

cs.CV ·2026-09-25 ·Wenjie Li, Zishan Xu, Jinyang Huang, Zhengxin Nie, Shichao Kan +1 more
benchmark similarity 0.69
Abstract

Cytopathology detection requires open-vocabulary recognition because cellular categories are fine-grained, long-tailed, and continuously evolving across different organ systems. However, existing cytology detectors are mostly single-domain and closed-set, and there is still no unified benchmark for evaluating open-vocabulary cytopathology detection. We present PentaCyto, a multi-domain benchmark covering cervical, urinary, respiratory, serous fluid, and thyroid cytology, with 24 base categories and 9 held-out novel categories. Each category is associated with structured cytomorphology prompts that describe diagnostic morphological attributes and provide clinically grounded textual knowledge. We further propose CytoSPM, an efficient detector based on a decoupled two-stage design. It first extracts reusable class-agnostic visual representations, and then performs class-aware structural prompt matching with class names and cytomorphology prompts. On PentaCyto, CytoSPM outperforms existing methods in novel-category detection and open-vocabulary detection while maintaining efficient inference.

0.24

Towards Scalable Context-Aware Single-Cell Spatial Transcriptomics Prediction from Histology Images

cs.CV ·2026-09-29 ·Zijun Gao, Chunbin Gu, Jinxi Xiang, Xiangde Luo, Pheng-Ann Heng
top venuehighly cited similarity 0.68
Abstract · Accepted to NeurIPS 2026

Predicting gene expression from H&E-stained histology images offers a scalable alternative to costly spatial transcriptomics, yet most existing methods operate at the spot level, where signals from multiple cells are aggregated and critical cellular heterogeneity is obscured. Extending this paradigm to single-cell resolution is non-trivial. Naively applying pathology foundation models faces a scale mismatch: their patch-level representations mix multiple cells, whereas per-cell cropping or resizing distorts morphology and removes local context. Conversely, segmentation-based models without strong pretrained visual encoders often lack the morphological representation capacity needed for accurate molecular prediction and inherit errors from imperfect cell boundary masks. Here, we present CELLO, an efficient end-to-end framework that performs a single pathology foundation model forward pass per image and uses grid sampling to extract location-specific features for all cells simultaneously. We further introduce a distance-decay cross-attention module that refines each cell representation using spatially biased local morphological context. Using 52 public Xenium-H&E pairs from HEST-1k that span 12 organs and approximately 10 million cells, CELLO improves the average predictive accuracy over the evaluated baselines while reducing the mean whole-slide inference time compared to DeepSpot2Cell, a 14.0x speed-up on average that excludes upstream cell segmentation. Our work establishes a scalable foundation for single-cell gene expression prediction from H&E images.

0.47

C-LiTE: A Lightweight Foundation Model for Cellular feature learning in Histopathology

cs.CV cs.AI ·2026-11-19 ·Esha Sadia Nasir, Jiaqi Lv, Gozde N. Gunesli, Shan E Ahmed Raza
similarity 0.67
Abstract

Characterising individual cells is fundamental to computational pathology, as cellular morphology informs tasks such as tumour grading, mitotic assessment and immune profiling. However, most pathology foundation models are trained on tissue patches and capture cellular features only implicitly, while existing cell-level models are either restricted to specific cell populations or rely on computationally expensive architectures with hundreds of millions of parameters. Applying ViTs directly to small cellular crops also presents an architectural challenge: upsampling increases computational cost without adding morphological information and may introduce interpolation artefacts. To address these limitations, we introduce C-LiTE, a lightweight foundation model for cellular representation learning in H&E-stained histopathology, with only 22 million parameters. C-LiTE employs a native-resolution tokenisation strategy tailored to cellular inputs, processing 64 x 64 px cell-centred crops using a 4 x 4 patch embedding to produce a 16 x 16 token grid without image upsampling. To transfer visual knowledge from large-scale pre-training, we adapt the patch embedding weights of a pre-trained ViT-5-S using a pseudoinverse-based transformation, enabling weight initialisation at the finer patch resolution. We further assemble a pre-training dataset of 60 million cell-centred crops from TCGA, balanced across 19 cancer types and 16 tissue types. To our knowledge, this represents the largest public dataset for self-supervised pre-training on H&E images at the cellular level. We evaluate C-LiTE on seven public datasets spanning mitotic figure recognition, nucleus and cell-type classification, and immune cell phenotyping. Under frozen-feature evaluation, C-LiTE achieves a mean macro-F1 of 0.670, approaching CytoFormer (0.682) with approximately 30x fewer parameters.

0.06

Exploiting Spatial Structure for Transductive Few-Shot Classification of Whole-Slide Images

cs.CV ·2026-09-25 ·Tiffanie Godelaine, Manon Dausort, Karim El Khoury, Benoît Gérin, Benoît Macq +1 more
similarity 0.66
Abstract · 5 pages, 2 figures

Automating the analysis of whole-slide images (WSIs), a key step in cancer diagnosis, has high clinical value, as it can reduce pathologist's workload while improving diagnosis accuracy. Recently, vision-language models have shown promising performance for patch-level classification without requiring any annotation, yet these zero-shot (ZS) predictions remain noisy on fine-grained tasks and must be further refined. A promising direction is to refine all predictions jointly, i.e., a transductive approach. However, most existing methods are not tailored to WSIs. We thus propose SlideTIM, an adaptation to WSIs of the recent transductive approach LC-TIM, which introduces a combined spatial--latent regularizer together with a prior on the patch class distribution. The former enforces spatially and semantically close patches to receive the same predictions, while the prior calibrates the predicted class proportions. Together, they address the complex spatial organization and the strong class imbalance of WSIs. Evaluated on four histology datasets, SlideTIM consistently outperforms all TIM variants, improving the macro-F1 by +8.1pp over the best competing baseline at 1 shot. Compared to the ZS, it raises the macro-F1 by +19.4pp at 1 shot. The code will be made available after submission.

0.19

HERO: Histology Encoder for Robust Representation in Oncology

cs.CV ·2026-09-28 ·Zhi Li, Eghbal Amidi, Yating Cheng, Tyson Dawson, Gorkem Can Ates +9 more
benchmarkcode/data similarity 0.66
Abstract · 22 pages, 4 figures, 13 tables; author information updated; scientific content unchanged

Foundation models trained on large pathology image corpora now provide strong, transferable representations for computational pathology. Over the past few years a series of such models has been released, each trained on more slides than the last; on standard classification and segmentation benchmarks, the leading models are now separated by small margins. In clinical use, however, the foundation model is applied to images from hospitals, scanners, and staining protocols outside its training data. Encoders generally embed these acquisition factors alongside biological information, which may introduce downstream errors and hinder safe clinical adoption. A pathology foundation model should therefore be robust to acquisition shift without giving up representation quality, yet robustness is seldom the axis along which models are compared. In this report, we introduce HERO (Histology Encoder for Robust Representation in Oncology), a ViT-G/14 pathology foundation model trained with the DINO and iBOT objectives and refined with high-resolution Gram anchoring on a morphology-balanced corpus of 500 million tiles from approximately 575,000 clinical whole-slide images. Across the evaluated public benchmarks, HERO shows the strongest robustness to center, scanner, and stain variation among the compared state-of-the-art foundation models, performs comparably on tile-level classification, segmentation, and gene-expression prediction, ranks first on average across 39 evaluated slide-level clinical tasks, and, under an equal-weighted framework-level analysis, has the best average rank across the six benchmark frameworks.

0.22

Predicting Single-Cell Spatial Gene Expression from H&E using Pathology Foundation Models

cs.CV ·2026-11-10 ·Ashley P. Tsang, Evan Liu, Conrad Foo, Bob Chen, Hassaan Maan +8 more
publishedcode/data similarity 0.64
Abstract · NeurIPS 2026 Workshop on AI at Scale for Clinical Impact. Project page: https://he2sc-st.github.io/

Predicting gene expression directly from hematoxylin and eosin (H&E) images offers a scalable and cost-effective approach to deriving spatial molecular insights from routine histology. Pathology foundation models, typically pretrained using tile-level objectives, may not adequately capture the fine-grained cellular features required for single-cell molecular prediction. In this work, we systematically evaluate and establish domain-informed and task-specific strategies for adapting pathology foundation models to single-cell spatial gene expression prediction. Using paired H&E and Xenium 5K data, our approach improves mean gene-wise Pearson correlation by 2.67x over the standard zero-shot baseline and achieves state-of-the-art performance on this task. We demonstrate strong gene-detection performance across the full gene panel (AUROC = 0.800) and importantly identify that predictive performance varies substantially across biological contexts, with our model achieving its highest Pearson correlation for spatially variable genes (r = 0.643). Our findings demonstrate that, despite the challenges of sparse single-cell measurements, H&E-derived representations can recover biologically meaningful spatial expression patterns, highlighting both the opportunities and limitations of morphology-based molecular inference at cellular resolution.

0.21

CellPlex: Benchmarking Single-Cell Spatial Proteomics Prediction from H&E

cs.CV ·2026-11-02 ·Zijun Gao, Yijiang Chen, Xiangde Luo, Pheng-Ann Heng
benchmark similarity 0.64
Abstract

Spatial proteomics measures tens of proteins in every cell of a tissue section, but its cost confines it to small research cohorts, whereas hematoxylin and eosin (H\&E) slides exist for nearly every patient. Inferring single-cell spatial proteomics from H\&E would bring its analyses to routine pathology, and a growing number of virtual staining models pursue this goal. Each is evaluated on its own cohort, panel and pixel-level metric, and released models transfer poorly to new cohorts, leaving open which approach to build on and which proteins H\&E can reveal. We introduce CellPlex, a benchmark that poses the task at the level of the cell: seven cohorts with same-section H\&E and multiplexed immunofluorescence, from colorectal and breast cancer to lymph-node metastases, bone marrow and glioma, with 717 samples, 44.8 million cells and 149 proteins, processed by one pipeline into per-cell targets. Pathology foundation models (PFMs) are adapted with one cell-level protocol, specialist models are fine-tuned under a matched budget, and all are scored on the same cells. Adapted PFMs are the most accurate models on every cohort, ahead of the specialists even after fine-tuning, but keep less than half of their accuracy on cohorts they were not trained on. Which proteins can be predicted depends on the tissue, not on how many cells were measured for them. By fixing the cells, targets and splits on which predictions are judged, CellPlex sets a common standard for inferring costly molecular measurements from routine H\&E and shows how far H\&E can stand in for spatial proteomics. We will release the data, splits, evaluation code and baselines as a testbed for developing and comparing future pathology foundation models and virtual staining methods.

0.21

Retrieval-Augmented Vision Foundation Models for Robust Leukemia Cell Classification across Multiple Microscopy Datasets

eess.IV cs.CVcs.LG ·2026-08-11 ·Carlos Zamora, Hiram Zuniga, Ulises Orozco-Rosas, Kenia Picos
published similarity 0.64
Abstract · Accepted at SPIE Optics + Photonics 2026 for oral presentation. 23 pages, 12 figures, 9 tables

Leukemia cell image classification is challenged by real-world domain shifts from acquisition, staining, illumination, and site protocols, causing single-dataset models to generalize poorly in real clinical scenarios. This work presents a robust framework for leukemia classification across multiple heterogeneous datasets using a two-stage pipeline with a pretrained vision foundation model. Stage 1 performs binary classification (leukemia vs. non-leukemia) and is trained using 122,167 single-cell images. Stage 2 is conditionally applied to Stage 1 positives to perform subtype classification into Acute Lymphoblastic Leukemia (ALL) and Acute Myeloid Leukemia (AML), trained using 69,400 single-cell images. Labels are harmonized across five heterogeneous datasets to enable cross-dataset training, and performance is evaluated on a held-out dataset protocol to assess domain-shift generalization. Within this pipeline, three encoders are benchmarked (DinoBloom, pretrained on single-cell images; BiomedCLIP, pretrained on biomedical data; and CLIP as a general-purpose model) under linear probing, Low-Rank Adaptation (LoRA), and a Retrieval-Augmented Classification (RAC) module that retrieves the top-k most similar cell images to provide cytomorphological grounding. The objective is to quantify how much domain-specific pretraining contributes to performance under domain shift, and whether cost-effective adaptation and retrieval can be a viable alternative to expensive domain-specialized pretraining. The held-out protocol additionally serves as a diagnostic tool, revealing when classification performance is attributable to dataset-specific artifacts rather than to cytomorphological features.

0.28