CS Paper Radar

Architecture-aware Robustness Evaluation of Explainable Deep Learning for Breast Cancer Diagnosis

Balenthira Thanusanth, Selvarajah Thuseethan, Roshan G. Ragel, Bimali S. Weerakoon, Ayesh Jayasinghe, Ananthamoorthy Krishnamoorthy

cs.CV ·submitted 2026-09-18 04:13 UTC · v1
code/data

Abstract

Explainable Artificial Intelligence (XAI) has become essential in medical image analysis to ensure transparency of deep learning (DL)-based diagnostic systems. However, selecting appropriate XAI techniques for breast cancer recognition remains largely ad hoc, with limited systematic evaluation across different DL architectures. This study presents a systematic architecture-aware evaluation protocol to assess the effectiveness of nine widely used XAI techniques across four categories of DL models: very deep, lightweight, transformer-based and hybrid neural networks. The evaluation is conducted on a breast ultrasound dataset comprising 780 images using clinically aligned spatial metrics, including Pointing Game, Intersection over Union and Mean Coverage, to quantify agreement between generated explanations and expert-annotated lesion regions. Results indicate that explanation quality is primarily influenced by the interaction between model architecture and XAI method, rather than any single technique consistently outperforming others. Hybrid architectures produce more spatially coherent explanations, while lightweight and transformer-based models exhibit greater variability across methods. The findings show that no single technique generalises across architectures and evaluation criteria, emphasising the need for joint selection of DL models and XAI techniques. Explainability depends on both model design and explanation strategy and should not be considered independently. This work provides a structured evaluation protocol and practical guidance for selecting XAI techniques in breast cancer diagnosis, supporting more transparent clinical decision-support systems. \textcolor{blue}{Code is publicly available at https://github.com/Nishan-Charlie/Explainable-AI}

Comment
12 pages, 7 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Interpretable Deep Learning Models for Breast Cancer Diagnosis Using Medical Imaging

cs.CV cs.AI ·2026-10-27 ·Sami Alnawali, Muhammad Atif Saeed, Abdul Hadi, Azka Atiq, Akhtar Jamil +1 more
benchmark similarity 0.80
Abstract · 37 page, 45 Figures

Deep learning shows promise for breast cancer diagnosis, but limited interpretability hinders clinical adoption. We benchmark ten ImageNet-pretrained models (ResNet50, VGG19, InceptionV3, DenseNet121, Xception, MobileNetV2, EfficientNet, ConvNeXt, ViT, and Swin Transformer) for benign-versus-malignant classification on the BreakHis histopathology dataset using a patient-level split, and explain their predictions with Grad-CAM, LIME, Integrated Gradients, and LRP. DenseNet121 performed best, with 99.4% test accuracy and an AUC-ROC of 0.999, and significantly outperformed all other models (p < 0.001). Transformer-based models trailed the CNNs. The explanations consistently highlighted nuclei-rich and glandular regions of diagnostic relevance. Combining transfer learning with explainable AI can thus yield accurate, interpretable tools for breast cancer diagnosis.

0.19

A Lightweight CNN Integrated Compact Convolutional Transformer for Multi-Scale Feature Learning and reducing computational complexity for breast cancer mammography image detection and classification

cs.LG cs.AIcs.CV ·2026-09-16 ·Md Taimur Ahad, Ainuddin Ahmed
similarity 0.73
Abstract

Over the years, Convolutional Neural Networks (CNNs) have demonstrated strong capability in cancer detection and classification using medical images. However, CNN-based models often struggle to capture long-range contextual dependencies. In such scenarios, integrating Compact Convolutional Transformer (CCT) architectures after the CCT layer allows CNN-extracted features to reshape into compact patch tokens using a CCT tokenizer, followed by the addition of positional embeddings to preserve spatial structure. Using 5-fold cross-validation, the model was tested on 3 sets of breast cancer mammography. With only 250,435 parameters, the model achieved 99%-100% accuracy across 3 datasets, indicating robust generalization. Explainable AI (XAI) was integrated into the model to explain the breast cancer classification process to enhance clinical trust. The results indicate that the proposed framework is suitable for computer-aided diagnosis systems, particularly in resource-constrained clinical environments. The novelty of the proposed CNN-integrated CCT overcomes the limitation of CNN's gradient degradation in the last layers by integrating convolutional tokenization with transformer-based learning. Lighter than ViT, which is effective in capturing long-range dependencies, the model has also proven efficient in breast cancer classification by capturing long-range dependencies among breast tissue regions.

0.20

How a Model's Architecture and Performance Influences Explainability: A Study of Grad-CAM and CRAFT in CNN-Based Image Classification

cs.CV cs.AI ·2026-11-09 ·Kilian Göller, Haadia Amjad, Steffen Seitz, Carsten Knoll, Ronald Tetzlaff
top venuehot direction similarity 0.72
Abstract · Accepted at the 4th World Conference on eXplainable Artificial Intelligence (xAI 2026), Fortaleza, Brazil, July 1-3, 2026. To appear in Spri…

Deep learning models, particularly convolutional neural networks (CNNs), are widely adopted in computer vision, yet their opaque decision-making raises concerns in high-risk applications like healthcare and autonomous systems, where trust and accountability are critical. Therefore, robust explainable AI (XAI) methods are desirable to provide transparent insights into model decisions. To ensure these methods are reliable and effective across diverse scenarios, it is important to understand how model performance and architectural complexity influence explanation quality. Our study takes an initial step toward systematically investigating the impact of these two factors on key XAI evaluation metrics. We constructed a pipeline using 10 subsets of ImageNet-1K, each containing 80 unique classes, on each of which we trained three CNN architectures of increasing structural complexity: VGG16, ResNet50, and ConvNeXt-Tiny. For each individual model, we analyzed 10 training checkpoints representing increasing levels of model accuracy using two XAI methods: Grad-CAM (feature-attribution-based) and CRAFT (concept-based). We assessed these methods across four evaluation categories: Faithfulness, Correctness, Sensitivity, and Simplicity. Our findings reveal that as training progresses, the complex architectures (ResNet50 and ConvNeXt-Tiny) exhibit improved Faithfulness and lower Sensitivity, indicating more robust explanations. In contrast, VGG16's simpler architecture yields simpler but less faithful and correct explanations.

0.39

ProtoCAM: Interpretable Few-Shot Mask-Guided Prototypical Learning for Breast Lesion Classification in Ultrasound Imaging

cs.CV cs.AI ·2026-09-11 ·Ashkan Ebadi
similarity 0.72
Abstract · 11 pages, 3 figures

Breast ultrasound imaging plays an important role in the early detection and diagnosis of breast cancer, particularly for patients with dense breast tissue. However, developing reliable deep learning models for ultrasound analysis is challenging due to limited annotated medical data and the need for interpretable predictions. To address these challenges, this paper proposes ProtoCAM, an explainable few-shot learning framework for breast lesion classification that integrates mask-guided feature encoding, prototypical metric learning, and gradient-based visual explanations. The proposed approach leverages lesion masks to guide feature extraction and constructs class prototypes within an embedding space to enable robust classification under limited training samples. The framework was evaluated on the BUSI dataset using a stratified group k-fold cross-validation protocol to prevent patient-level data leakage. Experimental results demonstrate ProtoCAM's high performance in low-data scenarios. In a 3-way 5-shot setting, the proposed method achieves a macro F1-score of 0.910, representing a substantial improvement over standard supervised CNN models. Among the evaluated backbone networks, ResNet18 achieved the best performance, reaching a macro F1-score of 91.65% under a 15-shot configuration, providing interpretable insights into the classification decisions. These results highlight the potential of explainable few-shot learning frameworks for reliable computer-aided breast cancer diagnosis in data-scarce medical imaging environments.

0.10

Boot-and-Feedback Framework for Generalist-Expert Model Collaboration in Breast Ultrasound Diagnosis

cs.CV cs.MM ·2026-08-25 ·Ming Cheng, Hongyu Sun, Zhaolin Chen, Jun Liu, Hossein Rahmani +1 more
published similarity 0.71
Abstract · 5 pages, 2 figures. Published in ICASSP 2026

Breast ultrasound (BUS) is widely used for breast cancer diagnosis yet remains operator-dependent. While deep learning shows promise, ensuring diagnostic reliability and interpretability is challenging. Recent Multimodal Large Language Models (MLLMs) often generate spurious descriptions due to limited domain knowledge, which mislead downstream expert models and compromise clinical validity. To address these challenges, we propose the Boot-and-Feedback (BooF) model collaboration framework for synergistic MLLM-expert interaction. Specifically, in the Boot Stage, the MLLM is guided by the BI-RADS lexicon and preliminary benign-malignant vision-expert predictions, enabling it to transfer general reasoning to BUS analysis while avoiding hallucinations. Subsequently, the Feedback Stage integrates these descriptions with visual features via a lightweight Attention-Gated Cross-Modality Fusion Module. This allows the expert to leverage textual feedback while adaptively filtering noise. Extensive experiments on multiple BUS datasets demonstrate that BooF substantially outperforms state-of-the-art methods in terms of diagnostic accuracy and interpretability.

0.52

MedCORE: Criteria-Grounded Clinical Reasoning for Interpretable Medical Image Diagnosis

cs.CV cs.AI ·2026-10-06 ·Asim Khan, Samee Ullah Khan, Dwarikanath Mahapatra
similarity 0.71
Abstract · 16 pages, 4 figures, conference

Clinical diagnosis is inherently a structured reasoning process, yet existing deep learning models often bypass this structure by mapping image features directly to disease labels without explicitly interrogating the morphological and textural criteria that clinicians systematically evaluate. This limits diagnostic transparency and may compromise safe clinical deployment. We present MedCORE (Medical Criteria-Oriented Reasoning and Evidence), a structured diagnostic framework that operationalizes clinical reasoning within a vision-language architecture. For each input image, MedCORE decomposes the diagnostic process into clinically defined criteria, spatially localizes each criterion to diagnostically relevant image regions, encodes evidence through multi-scale representations that capture macro-structural and micro-textural pathological characteristics, and refines criterion representations using a Graph Attention Network that explicitly models inter-criteria dependencies. Criterion representations are further aligned with clinical text descriptors, reinforced through class-wise visual prototypes, and aggregated using uncertainty-calibrated weighting that proportionally discounts low-confidence diagnostic evidence. MedCORE is validated across three clinically heterogeneous imaging modalities, including dermoscopic lesion classification on ISIC 2018, breast ultrasound lesion characterization on BUSI, and diabetic retinopathy grading on IDRiD. Quantitatively, MedCORE achieves 89.2% accuracy, 85.7% macro-F1, and 96.4% AUC on ISIC 2018; 96.1% accuracy, 95.2% macro-F1, and 98.4% AUC on BUSI; and 84.3% accuracy, 80.2% macro-F1, and 92.8% AUC on IDRiD. These results demonstrate consistent improvements over strong CNN, transformer, biomedical vision-language, concept-based, and prototype-based baselines.

0.20

BreastXAgent: A lightweight agentic explainability framework for breast density classification

cs.CV ·2026-10-13 ·Muhammad Turab, Raja Vavekanand, Knooz Fatima
published similarity 0.70
Abstract · 8 pages, 2 figures. Published in Proceedings of SPIE, Vol. 14346, Third International Conference on Frontiers of Applied Optics and Computer…

Deep learning models for breast density classification typically return only a label and confidence score. This paper presents BreastXAgent, a lightweight agentic framework that combines a pretrained classifier, Grad-CAM visual explanation, LangGraph-based routing, LLM report generation, and rule-based guardrails to produce controlled, faithful, non-diagnostic reports. On 160 mammography images, uncontrolled LLM reporting produced 75% Grad-CAM overclaims and 62.5% clinical overclaims. Strict prompting and LangGraph routing improved safety but did not eliminate violations. The full BreastXAgent achieved 100% safety pass rate, zero overclaims, and highest utility score. Results demonstrate that agentic guardrails enable safe, structured explanation generation without modifying the underlying classifier.

0.25

Robust Lightweight Deep Learning Models for Oral Cancer Screening

cs.AI ·2026-08-21 ·Siddhant Bharadwaj, Aakash Shedsale, Tejashree Subramanya, Mohd. Azfar, Praveen Birur +4 more
published similarity 0.70
Abstract · 10 pages, 3 figures, Paper accepted for the 6th International Conference on AI-ML Systems, 2026

Oral cancer is a leading cause of mortality in low-to-middle-income countries, where a shortage of specialists delays diagnosis. While point-of-care screening via smartphones offers a scalable solution, developing robust AI for resource-constrained settings poses significant challenges, including class imbalance in training data, variable data quality, and computational constraints on edge devices. In this paper, we present the optimisation of lightweight deep learning models for smartphone-based oral cancer screening. Using a diverse, multi-centre retrospective dataset of approximately 30,000 images acquired over a decade, we systematically evaluate state-of-the-art convolutional, transformer, and hybrid architectures. Through rigorous pipeline ablation, we demonstrate that directly optimising hybrid architectures for the edge strictly outperforms computationally heavy paradigms, such as large models or knowledge distillation. Furthermore, interpretability analysis and simulated noise-stress tests revealed that the system anchors on clinical features and remains robust to unstructured sensor noise, despite vulnerabilities to impulse bit errors. In the held-out test set, our optimised MobileViTv2 models achieved an average sensitivity of 83.2 $\pm$ 1.5% and an average specificity of 86.0 $\pm$ 0.8%, with the best model exhibiting 87.4% sensitivity, 86.5% specificity, and a critical negative predictive value of 97.2% with reference to specialist labels. These results confirm that with targeted architectural selection and streamlined optimisation, interpretable and robust lightweight AI models exhibit high potential for edge deployment to enable automated triage in primary care settings.

0.30