CS Paper Radar

Towards the Threshold: A Fall-Risk Anchored Pareto Framework for Virtual Reality Gait Feedback Selection for Individuals with Multiple Sclerosis

Nafisa Anjum, John Quarles, M. Rasel Mahmud

cs.HC ·submitted 2026-09-29 16:27 UTC · v1

Abstract

Reduced walking speed in people with multiple sclerosis (MS) is associated with an increased risk of falls. However, virtual reality (VR)-based rehabilitation studies often emphasize performance improvements without considering the cognitive and physical effort required to achieve them. This study introduces a threshold-anchored efficiency framework that jointly evaluates gait performance and overall effort. A normative walking-velocity target of \(T=1.29\) m/s was derived from the mean walking speed of non-fallers in an independent MS gait dataset and used as a clinically motivated reference point. Thirty-four adults with MS were evaluated across eight VR feedback conditions spanning unimodal, bimodal, and multimodal feedback. For each condition, we quantified the proportion of the velocity gap to the target that was closed and the associated cognitive and physical burden. Pareto efficiency analysis identified five non-dominated conditions: Static Visual, Spatial Auditory, Auditory+Visual, Auditory+Vibrotactile, and Multimodal, whereas Spatial Vibrotactile and Vibrotactile+Visual were dominated. Spatial Auditory showed a favorable performance-effort trade-off, closing 72.7% of the velocity gap while maintaining below-average burden. Multimodal feedback achieved the greatest gap closure (95.6%) but also imposed the highest burden. These findings demonstrate that greater gait improvement does not necessarily correspond to greater rehabilitation efficiency and provide a quantitative framework for comparing VR feedback strategies according to both performance gains and participant burden.

Closest papers

Nearest neighbours by meaning across the whole index.

Designing wearable haptic cueing for neurological gait rehabilitation: user requirements across residential care and community settings

cs.HC ·2026-10-30 ·Riasat Islam, Annemarie Zijlema, Theodoros Georgiou, Simon Holland, Blaine Price +3 more
similarity 0.61
Abstract · 38 pages, 2 figures, 4 tables. Preprint; manuscript currently under review in following journal - Disability and Rehabilitation: Assistive T…

Wearable haptic cueing offers rhythmic prompts for neurological gait rehabilitation while leaving hearing available for communication and environmental awareness. We investigated the user, design, and implementation requirements needed to make these systems usable in practice. We analysed six linked studies involving 17 people with neurological conditions affecting gait and three physiotherapists across formative sessions, residential care, and community self-management. Wearable devices served as technology probes. Observations, interviews, diaries, physiotherapist records, gait analysis, and activity logs informed thematic analysis and cross-study comparison. Seven recurring requirement areas concerned haptic perceptibility and placement, wearability and fastening, interaction burden, rhythm personalisation, real-world walking contexts, supported use, and perceived value beyond gait outcomes. Requirements interacted: perceptible cue locations could be difficult to access for fastening or control, while fixed rhythms did not always accommodate terrain, fatigue, interruptions, or changing pace. Carers and clinicians supported configuration, operation, safety, and interpretation. Participants described confidence, routine formation, and willingness to walk; these accounts were interpreted as perceived value rather than evidence of therapeutic efficacy. Low sensation, cognitive burden, and mobility limitations could make wearable cueing impractical. Future systems should offer adjustable haptic output, flexible placement, accessible fastening, simple controls, personalised rhythms, and robustness during everyday walking. Design should accommodate support from carers and clinicians and consider trade-offs between requirements. These findings inform wearable rehabilitation design rather than establish clinical efficacy.

0.28

Preliminary Evaluation of Transition-Aware Controller Locomotion Adaptations for Supporting Postural Stability in VR

cs.HC ·2026-09-30 ·Ramisa Fariha Joyee, M. Rasel Mahmud
published similarity 0.59
Abstract · 4 pages, 3 figures, accepted in ISMAR 2026 poster track

We present three locomotion adaptation approaches: Motion Acceleration, Turn Acceleration, and Motion Deceleration to improve postural stability during body-state transitions in virtual reality (VR). The system detects standing-to-walking, turning, and walking-to-stopping transitions and applies adaptive locomotion smoothing. Motion Acceleration gradually increases locomotion speed when users begin walking, Turn Acceleration smooths rotation while turning, and Motion Deceleration gradually reduces movement speed before stopping. We evaluated these techniques in a virtual navigation task using objective and subjective balance measures. Preliminary results show reduced center of pressure (COP) velocity and improved balance confidence. These findings suggest that locomotion adaptations can improve balance and navigation experience.

0.44

C-LISTEN: Cognitive Load Impacts of Sensory-Triggered Environmental Navigation in Virtual Reality

cs.HC ·2026-09-29 ·Md. Monowar Hossain, M. Rasel Mahmud
top venue similarity 0.57
Abstract · 6 pages. Published in AIVR 2026, The Third International Conference on Artificial Intelligence and Immersive Virtual Reality, Lisbon, Portug…

Nowadays, Virtual Reality (VR) systems are more helpful for making decisions, training, and rehabilitation. Multimodal settings in these systems impose a significant balance and cognitive difficulties. Additionally, decreased performance, higher cognitive load, user overwhelm, and limited accessibility of VR technology can be caused by excessive auditory, visual, and sensory stimulation. In our pilot study, we examine the strategic design of directional auditory cues to improve cognitive load and enhance user experience in virtual environments. This research also enhances fundamental knowledge that auditory feedback reduces cognitive load in VR, with statistical analysis confirming this improvement (p = .0011). This study investigates how postural balance and pupil diameter correlate with cognitive load while the users navigate. Moreover, this study provides realistic overview design guidelines for accessibility, which will make VR experiences safer and more useful for everyone, including people with cognitive impairments.

0.49

Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury

cs.CV ·2026-10-04 ·Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland +1 more
datasetcode/data similarity 0.56
Abstract

Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements (r = 0.68-0.90, p < 0.001, and RMSE = 4.18-6.49 degrees), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates (r = 0.85-0.87, p < 0.001, and RMSE = 2.13-2.19 Newton per kg). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury. Github: https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset

0.30

GaitVista: Reliability-Aware AI Measurement toward Accessible Longitudinal Gait Assessment

cs.AI ·2026-09-18 ·Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
similarity 0.53
Abstract

Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains confined to specialized motion-capture laboratories. Small camera sets and body-worn inertial sensors broaden access, but reliability varies across joints and time, allowing sensing failures to masquerade as patient change. We present \textsc{GaitVista}, a reliability-aware measurement layer whose lightweight gate assigns joint- and frame-specific visual contributions using camera coverage, local visual quality, cross-modal disagreement, and root-motion continuity, and exposes them for inspection. Across seven clean and degraded sensing conditions on TotalCapture, \textsc{GaitVista} reduces average full-body and lower-body error by \textbf{27.7\%} and \textbf{27.8\%}, attains the lowest worst-condition error among fusion methods, and reduces the gap to a joint-frame oracle from $2.76$--$5.33$~cm for condition-blind baselines to $1.11$~cm. On MoVi with image-derived keypoints, it is the only deployable fusion method to improve over both unimodal streams, reducing marker-supported error by \textbf{6.4\%} relative to the strongest learned fusion baseline. On TotalCapture, it improves bilateral knee-flexion waveform accuracy by \textbf{18.9\%}. Raw inertial measurements from five TotalCapture participants show location- and time-varying magnetic disturbance, supporting the design's reliability premise. Both benchmarks contain neurologically healthy participants in controlled settings and retain participant-specific IMU calibration; we therefore report progress toward accessible gait assessment, not validated clinical deployment.

0.23

Beyond Cross-Modal Reconstruction: Participant-Level Evaluation of sEMG-Kinematic Coupling in Post-Stroke Gait

cs.LG ·2026-11-18 ·Rafsan Jany, Md Rafid Islam, Mohammad Fahim Islam, Hafiz Abdur Rahman
similarity 0.53
Abstract

Accurate cross-modal reconstruction is often treated as evidence of physiological coupling, although it may simply reflect temporal patterns shared across participants. We tested whether frozen bidirectional models captured subject-specific neuromuscular coupling between electromyographic activity and gait kinematics in 82 held-out able-bodied and 43 post-stroke participants. Complete source-modality removal and cross-participant source substitution, along with a cycle-position-age-sex template baseline, were applied. Learned bilateral asymmetry was also compared with transparent waveform and derivative asymmetry for predicting Performance-Oriented Mobility Assessment (POMA) scores in the case of repeated nested cross-validation. Complete source removal increased reconstruction RMSE by 6.90% for electromyography-to-kinematics and 11.38% in the reverse direction. In contrast, cross-participant substitution increased RMSE by only 1.68% and 1.67%, respectively, while the template reduced RMSE by 2.89% and 0.55%. For POMA prediction, walking speed, age, and sex achieved an MAE of 3.693, compared with 4.229 and 4.427 after adding absolute and signed learned asymmetry, respectively. In all of the 20 repeated evaluations, all asymmetry representations performed worse than the covariate baseline. No localized learned feature remained significant after covariate adjustment and false-discovery-rate correction. The model mainly relied on shared gait-phase patterns, with no clear subject-specific coupling or added clinical value. Participant-level controls are therefore needed before reconstruction accuracy is treated as evidence of individualized physiology.

0.21

Slide to Report: Continuous Reporting Symptom-Specific Cybersickness in VR

cs.HC ·2026-11-05 ·Purnata Saha, Rifatul Islam, Qiliang He, John Quarles
similarity 0.52
Abstract

Cybersickness is often assessed during VR exposure through discrete overall sickness, which cannot capture specific symptoms or their changes over time. Post-exposure questionnaires such as the Simulator Sickness Questionnaire provide symptom-specific measures but cannot be collected during immersion. We investigate whether separating cybersickness into three symptom-specific dimensions -- nausea, oculomotor discomfort, and disorientation -- during immersion provides more informative continuous measurements. We conducted a between-subjects study with 52 participants in a VR-rollercoaster, comparing a three-slider interface with a single-slider interface. Concurrently, participants also completed an auditory Simon task to measure attention. We additionally collected multimodal set of physiological signals, including GSR, ECG, PPG, eye and head tracking. Results show that each slider correlated most strongly with its corresponding SSQ subscale, whereas the single slider correlated with all SSQ subscales. Using three sliders did not significantly affect usability, workload, or attention. We publicly release the multimodal dataset to support future cybersickness research.

0.20

Usability, User Experience, and Acceptability of the Trail Making Test in Virtual Reality in Younger and Older Adults

cs.HC cs.CY ·2026-10-16 ·Panagiotis Kourtesis, Dante O'Connor, Sarah E. MacPherson
similarity 0.52
Abstract · 20 pages, 3 figures, 4 tables, supplementary material are included

Immersive virtual reality (VR) adaptations of neuropsychological tests change how a test operates. Before their scores are interpreted, the individuals they are intended to assess should find them usable, acceptable and tolerable, and for older adults this evidence is usually missing. This study evaluated the experience of the Trail Making Test in Virtual Reality (TMT-VR), a head-gaze adaptation of the Trail Making Test that requires no hand-held controller, in 47 younger (20-38 years) and 44 older adults (64-81 years). After the task, participants rated usability, pragmatic and hedonic user experience, acceptability, and cybersickness. The study had three aims: to compare the two age groups on these ratings; to examine whether the ratings were associated with age group, gaming and technology experience, and whether cybersickness was associated with motion sickness susceptibility; and to examine whether the ratings were related to TMT-VR completion and error-adjusted times. Both groups rated the TMT-VR as highly usable, acceptable and pleasant to use. Older adults gave slightly lower usability and pragmatic ratings, but neither the age-group differences nor the associations with age group or previous experience were statistically significant after correction. Cybersickness was low, with 38 of the 91 participants reporting no symptoms; it did not differ between the age groups and was not associated with motion sickness susceptibility. No correlation between the ratings and TMT-VR performance survived correction. The TMT-VR with head-gaze selection is therefore usable, acceptable and well tolerated by older as well as younger adults. Because the ratings were favourable across the whole range of TMT-VR scores, slower or less accurate performance is unlikely to reflect difficulty with the interface.

0.37