CS Paper Radar

Diffusion-Based Synthetic Data Pretraining for Enhancing Activity Recognition

E. Riveros, D. Vega-Oliveros, A. Soriano-Vargas, A. Rocha

cs.LG cs.AI ·submitted 2026-10-01 16:43 UTC · v1

Abstract

Human activity recognition (HAR) is increasingly important for healthcare, well-being, and daily monitoring ap- plications, for which detecting alimentary activities such as eating and drinking can provide actionable insight into dietary habits and chronic disease management. HAR systems, however, often underperform on subtle and underrepresented classes, limiting their utility in real-world dietary monitoring. This work builds upon CABiGRU, a convolutional architecture with Bidirectional GRU layers, multi-head attention, and residual connections, designed to capture discriminative temporal patterns from smart- watch accelerometer, gyroscope, and magnetometer data. To improve CaBiGRU's generalization and reduce underfitting in the minority class, we leverage synthetic sensor data windows using a diffusion model and adopt a two-stage training strategy: pre-training CABiGRU on synthetic data, followed by fine-tuning on the real-world data. On the DEO (drinking/eating/other) dataset, the proposed pipeline achieves a balanced accuracy of 90.6%, improving over a strong supervised baseline and showing the benefits of diffusion-based synthetic pre-training for recognizing alimentary activities and representing a step forward dealing with unbalanced classes. These results suggest that combining diffusion-generated data with targeted fine-tuning enhances robust recognition of dietary behaviors, supporting more reliable deployment in healthcare and nutrition-monitoring settings.

Comment
6 pages, 3 figures, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

An Effective, Reliable, and Robust Framework for Human Activity Recognition Using Wearable Sensors

cs.LG ·2026-09-29 ·Nafees Ahmad, Ho-fung Leung, Muhammad Adil Abid, Sadia Shakil
similarity 0.71
Abstract

Human Activity Recognition (HAR) through wearable sensors greatly improves the quality of human life through its multiple applications. For HAR, multi-sensor channel information is vital for optimal performance. Current work states that applying an attention neural network to prioritize discriminatory sensor channels helps the model classify activity more precisely. However, obtaining discriminatory information from multisensory channels is not always trivial, such as when collecting data from older hospitalized patients. In this context, existing HAR methods struggle to classify activities, particularly activities with similar natures. Moreover, HAR models predominantly suffer from overfitting due to the small size of available datasets, which leads to poor performance. Data augmentation (DA) is a viable solution to this problem. However, available DA methods have various drawbacks, including the possibility of being domain-dependent, resulting in distorted models for test sequences. To address these HAR problems, we propose a novel framework, ALAE-TAE-CutMix+, which focuses on two aspects. First, it enhances the latent information across each sensor channel and learns to exploit the relation among multiple latent features and the ongoing activity. Consequently, the discriminatory feature representations of each activity is enriched. Second, a new augmentation strategy is introduced to address the shortcomings of existing multi-sensor channel data augmentation. We then extend the framework to create a further enhanced version, namely ALAE-CIE-TAE-CutMix+, which learns to capture the interactions between the features of each pair of sensor channels. We find that although the first framework performs slightly better than the latter, the latter is nonetheless more reliable and robust. Both frameworks significantly outperform SOTA approaches on the four HAR datasets from diverse domains.

0.35

LITEWAY: LIghtweight HAR via Temporal Efficient highWAY

cs.LG cs.AIcs.HC ·2026-08-10 ·Dominique Nshimyimana, Vitor Fortes Rey, Mengxi Liu, Bo Zhou, Paul Lukowicz
publishedcode/data similarity 0.70
Abstract · accepted at UbiComp / ISWC 2026

Wearable human activity recognition (HAR) remains challenging due to the computational and energy constraints of deep learning models on resource-limited devices. Existing lightweight approaches often rely on recurrent architectures (e.g., GRU and LSTM), limiting parallelism and increasing inference latency. We propose LITEWAY, a modality-agnostic, fully convolutional framework for multichannel sensor time series that replaces recurrent temporal modeling with structured convolutional decomposition. LITEWAY combines lightweight convolutional blocks, strided temporal processing, and convolution-attention pooling to efficiently capture temporal dependencies while reducing computational complexity. We evaluate LITEWAY on 16 HAR datasets against TinyHAR, TinierHAR, and MLP-HAR. LITEWAY achieves competitive macro F1 while reducing model size by 4.06x-9.52x (Light) and 3.87x-9.07x (Full) compared with TinyHAR and TinierHAR. Deployment experiments further show energy reductions of 2.29x-3.14x (Light) and 1.46x-2.01x (Full) compared with TinierHAR and MLP-HAR, highlighting efficient fully convolutional temporal modeling for wearable HAR. The source code is publicly available at https://github.com/dominique-nshimyimana/liteway.

0.42

Characterizing the Performance Gap in Human Activity Recognition for Older Adults

cs.HC cs.LG ·2026-10-02 ·Hossein Khayami, Sungjin Hwang, Eshed Ohn-Bar, David E. Conroy, Amanda Lazar +2 more
publishedbenchmark similarity 0.65
Abstract · 8 pages, 6 figures, to be published in Proceedings of the 2026 ACM International Symposium on Wearable Computers (ISWC '26)

Human activity recognition (HAR) from wrist-worn accelerometers is increasingly used for health and behavioral tracking. Yet, most wearable HAR models are developed and evaluated on datasets dominated by younger adults, leaving it unclear whether benchmark progress generalizes across age groups. In this work, we leverage MyMove, our carefully annotated, free-living older-adult HAR dataset (mean age 71), to evaluate deep-learning architectures and training regimes under both leave-one-subject-out and cross-dataset transfer. We find that improvements on younger-adult benchmarks fail to transfer equally to data collected from older adults, resulting in a persistent and often widening performance gap. However, richer representations, particularly frozen self-supervised features pretrained on the age-diverse UK Biobank dataset, substantially improve performance on data from older adults and consistently narrow the performance gap, at modest cost to younger-adult performance, though disparities remain. These findings suggest that benchmark gains and architectural scaling alone provide an incomplete picture of progress in wearable HAR, and broader advances may require representations that better capture population diversity, alongside personalized adaptation to individual movement patterns and routines.

0.21

HeteroWear: Sensor-Aware Self-Supervised Learning for Heterogeneous Wearable Activity Recognition

cs.LG cs.AIeess.SPstat.ML ·2026-11-13 ·Yasaman Mohammadpour, Pouya Shaeri
publishedcode/data similarity 0.64
Abstract · Extended version of a paper accepted at IEEE BigData 2026. Code: https://github.com/yasamanmohammdpour/HeteroWear

Self-supervised learning for wearable sensing is usually confined to a single dataset or device family, leaving open whether representations transfer across heterogeneous sensor configurations and whether gains come from pretraining rather than architecture or richer sensor input. We present HeteroWear, a sensor-aware self-supervised framework pretrained on an eight-dataset wearable corpus (173 subjects, 358,261 windows) spanning inertial and physiological signals across body locations, devices, and sampling rates. HeteroWear separates within-sensor temporal modeling from cross-sensor relational modeling using sensor-context embeddings, temporal and cross-sensor Transformers, and latent cross-attention fusion. Training combines structured sensor dropout, cross-configuration consistency, and per-axis masked sensor modeling; missing sensors are omitted rather than reconstructed. Under leave-one-dataset-out pretraining and subject-disjoint evaluation on PAMAP2, WISDM, HHAR, HARTH, and UCI-HAR, HeteroWear improves mean macro-F1 from 0.688 to 0.724 over the identical architecture trained from scratch, with the largest gain on HHAR (0.823 versus 0.741), and achieves the highest macro-F1 on four of five benchmarks relative to single-accelerometer supervised baselines. Held-out-device evaluation yields a mean +0.066 macro-F1 improvement. Under 50% test-time channel removal, HeteroWear retains 73.8% of full-channel performance versus 64.1% for the same architecture trained from scratch without sensor dropout. Ablations show that structured sensor dropout primarily drives robustness, while cross-configuration consistency and sensor-context encoding contribute to transfer.

0.30

A Group-Aware Comparative Study of Classical Machine Learning and Deep Learning Methods for Sensor-Based Human Activity Recognition

cs.LG cs.AIeess.SP ·2026-10-08 ·Wahyu Pebrianto
similarity 0.63
Abstract

Human Activity Recognition (HAR) using wearable or smartphone inertial sensors is commonly evaluated with both classical machine learning and deep learning methods. However, reported performance can be strongly affected by sensor modality, dataset characteristics, and data-splitting strategy. This study presents a controlled comparative evaluation of four classical machine learning models and four deep learning models on two public HAR datasets, UCI-HAR and KU-HAR. Three sensor modalities were considered: accelerometer (ACC), gyroscope (GYRO), and their combination (ACC+GYRO). Classical machine learning models used handcrafted statistical features, while deep learning models operated directly on raw sensor sequences. The primary evaluation employed five-fold StratifiedGroupKFold cross-validation, with subject- or participant-level grouping to prevent group overlap between training and test folds. Macro-F1 was used as the primary performance metric. The results show that deep learning did not consistently outperform classical machine learning. On UCI-HAR, the evaluated deep learning models achieved slightly higher macro-F1 values, whereas on KU-HAR, LightGBM achieved 0.857 compared with 0.828 for the highest-performing evaluated deep learning model. Regarding sensor modality, the combined ACC+GYRO configuration generally outperformed ACC or GYRO alone on both datasets. The evaluation protocol also had a substantial effect: for CNNBiLSTMAttn with ACC+GYRO, random splitting increased macro-F1 by 0.033 on UCI-HAR and 0.093 on KU-HAR compared with grouped evaluation. These findings highlight the importance of model family, sensor modality, dataset characteristics, and group-aware evaluation when assessing sensor-based HAR systems.

0.14

Domain Generalization for Smartphone-Based Human Activity Recognition: A Systematic Analysis of Components and Interactions

cs.AI ·2026-09-14 ·Otávio Oliveira Napoli, Edson Borin
benchmark similarity 0.62
Abstract · 27 pages, 14 figures, and 10 tables

Smartphone-based Human Activity Recognition (HAR) models often degrade under distribution shifts caused by changes in users, devices, sensor placements, environments, and acquisition protocols. Domain Generalization (DG) addresses this problem by learning from source domains without access to target data. Existing DG methods span training objectives, representation initialization, and architectural modifications, but these components are typically evaluated in isolation despite operating at different stages of the learning pipeline. We present a large-scale controlled benchmark of DG for smartphone-based HAR, comprising more than 410,000 experiments across four model architectures, thirteen training objectives including Empirical Risk Minimization (ERM), five initialization strategies, four architectural configurations, and two shift scenarios: cross-dataset and cross-position. Results show that individual DG components provide limited and highly conditional gains. Alternative objectives rarely outperform ERM consistently, self-supervised initialization helps in specific settings, and architectural modifications, particularly Dynamic Domain Generalization, provide the clearest standalone improvements. Joint configurations, however, frequently outperform their individual components and exhibit complementary and sometimes super-additive interactions, although gains remain model- and shift-dependent. Class-level analysis shows that the strongest configurations mainly improve difficult, shift-sensitive decision boundaries. Finally, oracle checkpoint analysis reveals substantial unrealized performance: source-validation selection recovers only 53% and 26% of the available oracle gain in cross-dataset and cross-position settings, respectively. Overall, effective HAR domain generalization requires jointly designing DG components and robust model-selection strategies.

0.15

Data-Efficient Classifier Pretraining Through Diffusion Models

cs.LG ·2026-10-16 ·Qinyu Li, Yee Whye Teh, Chris Holmes, Joel Jaskari
similarity 0.62
Abstract

Machine learning with limited data is susceptible to overfitting, especially with modern deep neural networks. Prior to the introduction of AlexNet, reconstruction-based pretraining with auto-encoder and denoising auto-encoder were found to be beneficial, partially due to the limited size of the training sets at the time. Motivated by these traditional approaches, we propose DiffPT, a simple diffusion modeling approach to pretrain a given classifier backbone for limited domain-specific training data. We experiment on time-series data, standard natural-image benchmarks, and medical imaging datasets, and contrast the diffusion approach to a multitude of modern and traditional un/self-supervised methods. While contrastive pretraining performs better on CIFAR-10 and Tiny ImageNet in low-data regimes, DiffPT is particularly effective on medical imaging and time-series tasks, where it outperforms self-supervised baselines across a range of low-data regimes. Our results suggest that DiffPT is a simple and effective approach for data-efficient classifier pretraining on different modalities.

0.12

Foundation models for movement data: Are they ready for prime-time?

eess.SP cs.LG ·2026-08-13 ·Alexander Bräuer, Benjamin Cauchi, Nils Strodthoff
code/data similarity 0.62
Abstract · 14 pages, 6 figures, 8 tables, code is available at https://github.com/AI4HealthUOL/movement-fm-benchmarking

Foundation models (FMs) trained on large-scale accelerometer data have been proposed as general-purpose feature extractors for health monitoring, but systematic evidence of their advantages is lacking. We present the first comprehensive evaluation of four open-source accelerometer FMs against supervised baselines covering 19 tasks across the domains of activity recognition including activities of daily living, clinical monitoring, and physiological inference. We find task-dependent performance results: supervised models remain competitive with FMs on human action recognition (HAR), with no consistent advantage for either, while selected FMs lead on fall and stress detection and are the most robust to sensor-placement variation. As frozen feature extractors, FMs are strongest for demographic inference, whereas sleep staging performance remains near chance level for all models. The internal FM representations show strong similarity across layers, highlighting potential for future FM improvements. Linear and frozen probing reveals that UniMTS provides the strongest representations and is the only FM that surpasses the supervised baselines without finetuning. Concept discovery analysis shows all models capture high-intensity activities clearly but struggle with sedentary, complex or ambiguous activities. We provide scenario-based deployment recommendations. Furthermore, we identify FM-derived activity profile inference-moving beyond fixed category classification-as a promising research direction.

0.30